At least 91 records · Page 5

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration↗

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M↗

Suppression of diffraction in deep-inelastic scattering on nuclei and dynamical mechanism of leading twist nuclear shadowing

Abstract Using the leading twist approach (LTA) to nuclear shadowing, we calculate the ratios of diffractive and usual parton distributions for a heavy nucleus (Pb) and the proton,$$ {R}_{A/p}=\left({f}_{i/A}^{D(3)}/{f}_{i/A}\right)/\left({f}_{i/p}^{D(3)}/{f}_{i/p}\right) $$ R A / p = f i / A D 3 / f i / A / f i / p D 3 / f i / p , for coherent and summed (coherent plus quasi-elastic) nuclear deep-inelastic scattering. We find thatR A/p ≈ 0.5 − 1 for quarks as well as for the ratio of the diffractive and total cross sections$$ {\left[\left({d\sigma}_{\textrm{diff}}/{d M}_X^2\right)/{\sigma}_{\textrm{tot}}\right]}_{eA}/{\left[\left({d\sigma}_{\textrm{diff}}/{d M}_X^2\right)/{\sigma}_{\textrm{tot}}\right]}_{ep} $$ dσ diff / dM X 2 / σ tot eA / dσ diff / dM X 2 / σ tot ep andR A/p ≈ 0.5 − 1.3 for gluons in a broad range ofx, including the kinematics of the Electron-Ion Collider, which reaffirms the difference from the nuclear enhancement ofR A/p predicted in the gluon saturation framework. We demonstrate that the magnitude ofR A/p is controlled by the cross section of the interaction of hadronic fluctuations of the virtual photon with target nucleons, which explains an enhancement ofR A/p in the color dipole model and its suppression in LTA. We argue that the black disk limit corresponds toR A/p = 1 and$$ {R}_{A/p}^{\textrm{coh}} $$ R A / p coh = 0.86 for the summed and coherent scattering, respectively. Relying on an intuitive definition of the saturation scale, we show that the ratio of the saturation scales of a heavy nucleus and proton$$ {Q}_{sA}^2(b)/{Q}_{sp}^2(b)\approx 1 $$ Q sA 2 b / Q sp 2 b ≈ 1 at small impact parametersbdue to the strong leading twist nuclear shadowing and diluteness of the nuclear density.

Physics↗

TMD factorisation for diffractive jets in photon-nucleus interactions

Abstract Using the colour dipole picture and the colour glass condensate effective theory, we study the diffractive production of two or three jets via coherent photon-nucleus interactions at high energy. We consider the hard regime where the photon virtuality and/or the transverse momenta of the produced jets are much larger than the saturation momentumQ s of the nuclear target. We show that, despite this hardness, the leading-twist contributions are controlled by relatively large parton configurations, with transverse sizesR~ 1/Q s , which undergo strong scattering and probe gluon saturation. We demonstrate that these leading-twist contributions admit transverse-momentum dependent (TMD) factorisation, in terms of quark and gluon diffractive TMD distribution functions, for which we obtain explicit expressions from first principles. We go beyond our previous work by evaluating the contributions involving the quark diffractive distributions and by establishing that their DGLAP evolution emerges via controlled calculations within the colour dipole picture. We find the same expression for the quark diffractive TMD in two different processes (semi-inclusive diffraction and the diffractive production of quark-gluon dijets), thus demonstrating its universality.

Physics↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Suppressing Charged Cation Antisites via Se Vapor Annealing Enables p-Type Dopability in AgBiSe 2 –SnSe Thermoelectrics

Cation disordering is commonly found in multinary cubic compounds, but its effect on electronic properties has been neglected because of difficulties in determining the ordered structure and defect energetics. An absence of rational understanding of the point defects present has led to poor reproducibility and uncontrolled conduction type. AgBiSe 2 is a representative compound that suffers from poor reproducibility of thermoelectric properties, while the origins of its intrinsic n-type conductivity remain speculative. Here, it is demonstrated that cation disordering is facilitated by Bi Ag charged antisite defects in cubic AgBiSe 2 which also act as a principal donor defect that greatly controls the electronic properties. Using density functional theory calculations and in situ Raman spectroscopy, how saturation annealing with selenium vapor can stabilize p-type conductivity in cubic AgBiSe 2 alloyed with SnSe at high temperatures is elucidated. With stable and controlled hole concentration, a peak is observed in the weighted mobility and the density-of-states effective mass in AgBiSnSe 3 , implying an increased valley degeneracy in this system. These findings corroborate the importance of considering the defect energetics for exploring the dopability of ternary thermoelectric chalcogenides and engineering electronic bands by controlling self-doping.

36 MATERIALS SCIENCE↗

Solid state grain alignment of permanent magnets in near-final shape

Magnet microstructure manipulation in the solid state by controlled application of a sufficient stress in a direction during high temperature annealing in a single-phase region of heat-treatable magnet alloys, e.g., alnico-type magnets is followed by magnetic annealing and draw annealing to improve coercivity and saturation magnetization properties. The solid-state process can be termed highly controlled abnormal grain growth (hereafter AGG) and will make aligned sintered anisotropic magnets that meet or exceed the magnetic properties of cast versions of the same alloy types.

Anderson, Iver E.↗

Solid state grain alignment of permanent magnets in near-final shape

Magnet microstructure manipulation in the solid state by controlled application of a sufficient stress in a direction during high temperature annealing in a single-phase region of heat-treatable magnet alloys, e.g., alnico-type magnets is followed by magnetic annealing and draw annealing to improve coercivity and saturation magnetization properties. The solid-state process can be termed highly controlled abnormal grain growth (hereafter AGG) and will make aligned sintered anisotropic magnets that meet or exceed the magnetic properties of cast versions of the same alloy types.

Anderson, Iver E.↗

Tip‐Enhanced Imaging and Control of Infrared Strong Light‐Matter Interaction

Optical antenna resonators enable control of light‐matter interactions on the nano‐scale via electron–photon hybrid states in strong coupling. Specifically, mid‐infrared (MIR) nano‐antennas coupled to saturable intersubband transitions in multi‐quantum‐well (MQW) semiconductor heterostructures allow for the coupling strength to be tuned through antenna resonance and field intensity. Here, in this study, tip‐enhanced nano‐scale variation of antenna‐MQW coupling across the antenna is demonstrated, with a spatially‐dependent coupling strength $g_{\textrm{aq}}$ varying from 73 (strong coupling) to 24 cm -1 (weak coupling). This behavior is modeled based on the spatially dependent local constructive and destructive interference between tip and antenna fields. Using a quantum‐mechanical density‐matrix model of the MQW system with its designed values of transition dipole moment, doping density, and population decay time, the picosecond IR pulse coupling to intersubband transitions and the associated tip induced strong‐field saturation effects are described. These results present a new regime of nonlinear IR light‐matter control based on the dynamic manipulation of quantum hybrid states on the nanoscale and in the infrared, with a perspective regarding extension to molecular vibrations.

Wang, Yueying↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Solubility controls on plutonium and americium release in subsurface environments exposed to acidic processing wastes

To identify the role of waste composition and sediment interactions in controlling Pu and Am mobility in contaminated sediments at Hanford, a legacy nuclear site, Pu and Am concentrations in solutions equilibrated with contaminated sediments from beneath the 216-Z-9 (Z-9) Trench were compared to the solubilities of PuO 2 materials, synthesized by methods representative of the disposed wastes, in the absence of sediments. Furthermore, this work shows that the solubilities of PuO 2 materials synthesized by different methods, and with varying particle sizes, agree with PuO 2 (am,hyd), although dissolution kinetics differed between materials. According to saturation index (SI) calculations, PuO 2 (am,hyd) is likely also controlling Pu release from sediments under conditions where phosphate concentrations are low. However, both Pu-phosphate and Am-phosphate phases, identified in SI calculations and by high resolution transmission electron microscopy, play roles in controlling release in low pH, high phosphate, shallow sediments just below the Z-9 Trench. The elevated phosphate is likely due to decomposition of tributyl phosphate from waste solutions over time. Sediments from deeper in the subsurface beneath the Z-9 Trench are less acidic and contain less phosphate, with Pu solubility likely controlled by PuO 2 (am,hyd) that precipitated following neutralization of the acidic waste stream. Controls on Am concentrations in deeper sediments are more complex and potentially involve sediment adsorption and/or release from Pu (1-x) Am x O 2 following Am in-growth. The concentrations of both Pu and Am were elevated in the colloidal fraction associated with shallow sediments, but not in PuO 2 experiments, suggesting the presence of Pu/Am pseudocolloids (e.g., Pu/Am associated with mineral colloids). However, Pu and Am association with the colloidal size fraction was not observed in deeper sediments, suggesting transport of Pu and Am to these depths beneath the Z-9 Trench was not due to colloidal transport.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Vanadate Retention by Iron and Manganese Oxides

Anthropogenic emissions of vanadium (V) into terrestrial and aquatic surface systems now match those of geogenic processes, and yet, the geochemistry of vanadium is poorly described in comparison to other comparable contaminants like arsenic. In oxic systems, V is present as an oxyanion with a +5 formal charge on the V center, typically described as H x VO 4 (3–x)– , but also here as V(V). Iron (Fe) and manganese (Mn) (oxy)hydroxides represent key mineral phases in the cycling of V(V) at the solid–solution interface, and yet, fundamental descriptions of these surface-processes are not available. Here, we utilize extended X-ray absorption fine structure (EXAFS) and thermodynamic calculations to compare the surface complexation of V(V) by the common Fe and Mn mineral phases ferrihydrite, hematite, goethite, birnessite, and pyrolusite at pH 7. Inner-sphere V(V) complexes were detected on all phases, with mononuclear V(V) species dominating the adsorbed species distribution. Our results demonstrate that V(V) adsorption is exergonic for a variety of surfaces with differing amounts of terminal –OH groups and metal–O bond saturations, implicating the conjunctive role of varied mineral surfaces in controlling the mobility and fate of V(V) in terrestrial and aquatic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure-property correlations and scaling in the magnetic and magnetocaloric properties of GdCrO 3 particles

The structure, magnetic, and magnetocaloric (MC) properties of orthorhombic nanocrystalline GdCrO 3 with six particle sizes: < d > = 87, 103, 145, 224, 318, and 352 nm are reported. The particle size was tailored by annealing under different temperatures and estimated by scanning electron microscopy. With increase in < d >, Goldschmidt tolerance factor t, orthorhombic strain s, and out-of-plane Cr–O 1 –Cr bond angle first decrease, reaching minimum values for < d > = 224 nm, and then increase for sample with < d > = 318 nm and 352 nm, thus showing a V-shaped variation. Temperature dependence of the magnetization (M) reveals an antiferromagnetic transition at ${T}_{\text{N}}^{\text{Cr}}\sim 168$ K for < d > ≥ 224 nm and ${T}_{\text{N}}^{\text{Cr}}\sim 167$ K for < d > < 224 nm and an essentially d-independent spin-reorientation at T SR = 9 K. M measured at 5 K and 7 T first increases with increase in < d >, reaching maximum value for sample with < d > = 224 nm, and then decreases for samples with < d > = 318 nm and 352 nm, showing an inverted-V variation with < d >. Similar < d >-dependence is observed for the magnetic entropy change (MEC) and relative cooling power (RCP) showing a close relationship between the structural and magnetic properties of GdCrO 3 nanoparticles investigated here. The 224 nm sample with the minimum values of t, s, and Cr–O 1 –Cr bond angle exhibits the maximum value of MEC (–ΔS) = 37.8 J kg –1 K –1 at 5 K under a field variation (ΔH) of 7 T and its large estimated RCP of 623.6 J Kg –1 is comparable with those of typical MC materials. Both (–ΔS) and RCP are shown to scale with the saturation magnetization MS, suggesting that MS is the crucial factor controlling their magnitudes. Assuming (–ΔS) ~ (ΔH) n , the temperature dependence of n for the six samples are determined, n varying between 1.3 at 5 K to n = 2.2 at 130 K in line with its expected magnitudes based on mean-field theory. Furthermore, these results on structure-property correlations and scaling in GdCrO 3 suggest that its MC properties are tunable for potential low-temperature magnetic refrigeration applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-Node Program Fuzzing on High Performance Computing Resources

Significant effort is placed on tuning the internal parameters of fuzzers to explore the state space, measured as coverage, of binaries. In this work, we investigate the effects of the external environment on the resulting coverage after fuzzing two binaries with AFL for 24 hours. Parameters such as scaling to multiple nodes, node saturation, and parallel file system type on HPC resources are controlled in order to maximize coverage. It will be shown that employing a parallel file system such as IBM's General Parallel File System offers an advantage for fuzzing operations, since it contains enhancements for performance optimization. When combined with scaling to two and four nodes, while simultaneously restricting the number of coordinated AFL tasks per node on the low end (10-50% of available physical cores), coverage may be enhanced within a shorter period of time. Thus, controlling the external environment is a useful effort.

97 MATHEMATICS AND COMPUTING↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗