Search NASA⌕ Search

SEARCH · Search NASA

Results for “coupon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhanced plasma current collection from weakly conducting solar array blankets

Among the solar cell technologies to be tested in space as part of the Solar Array Module Plasma Interactions Experiment (SAMPIE) will be the Advanced Photovoltaic Solar Array (APSA). Several prototype twelve cell coupons were built for NASA using different blanket materials and mounting techniques. The first conforms to the baseline design for APSA which calls for the cells to be mounted on a carbon loaded Kapton blanket to control charging in GEO. When deployed, this design has a flexible blanket supported around the edges. A second coupon was built with the cells mounted on Kapton-H, which was in turn cemented to a solid aluminum substrate. A final coupon was identical to the latter but used germanium coated Kapton to control atomic oxygen attack in LEO. Ground testing of these coupons in a plasma chamber showed considerable differences in plasma current collection. The Kapton-H coupon demonstrated current collection consistent with exposed interconnects and some degree of cell snapover. The other two coupons experienced anomalously large collection currents. This behavior is believed to be a consequence of enhanced plasma sheaths supported by the weakly conducting carbon and germanium used in these coupons. The results reported here are the first experimental evidence that the use of such materials can result in power losses to high voltage space power systems.

Hillard, G. Barry↗

Permeability Measurements in Carbon-Epoxy Composites

To determine the permeability of the composite feedline, that is proposed to be used in the X-33 Reusable Launch Vehicle (RLV), three 8 x 8-in. coupons were constructed. Two of the coupons were layed-up with 4 plies of plain weave prepreg [0/90, plus or minus 45, plus or minus 45, 0/90] and the other one layed-up with 4 plies of unidirectional prepreg [0, 90, 90, 0]. The coupons were vacuumed bagged and cured to manufactures specifications. The coupons were then placed in an apparatus to test for permeability. Nitrogen gas was used to permeate through the coupons at a pressure of 5 psig. A manometer was placed on the opposite side of the coupons and was used to measure the height of the fluid with respect to time. From this data the mass flow rate of the gas could be calculated since the area of the manometer and the density of the gas is known. The results of the test are given. The permeability constant was calculated using Darcy's law, which related the pressure drop, flow rate of the permeating gas and resistance to flow through the coupon created. To put the results into prospective the permeability of sand stone and granite is 1E-15 and 1E-20 respectively.

Zdenek, Michael J.↗

Space Shuttle filament wound case compressive strength study. II - Analysis

In order to explain the results of the testing conducted in Part I and relate the subscale test specimen performance to case performance during prelaunch loading, a comprehensive analysis program was conducted. Finite element models of both full-scale case and subscale test coupons were made. Validated axisymmetric models were used for the case analyses. Modeling of coupons was accomplished using a generalized plane strain finite element model in most cases, although some three-dimensional finite element modeling was used to investigate the importance of three-dimensional effects on the coupon performance. The large number of plies and complexity of the test coupons used limited the finite element grids to a through-the-thickness discretization of one element per ply. Delaminations observed in the helical ply dropoff region were modeled using frictionless sliders. Comparisons of predicted strains and displacements were made with the test data from both cases and coupons to validate the finite element models. Based on observations of the test results and finite element predictions, a failure criterion for both coupons and cases was postulated and then validated by comparing performance predictions to test results. Finally, the validated failure criterion was used to predict the performance of the first two flight cases under prelaunch loads.

Messick, M. J.↗

Impact response of graphite/epoxy fabric structures

The impact damage resistance and damage tolerance of graphite/epoxy fabric plate (coupon) and cylinder structures were investigated and compared in an analytical and experimental study. Hercules A370-5H/3501-6 five-harness satin weave cloth in a quasi-isotropic (0,45)(sub s) laminate configuration was utilized. Specimens were impacted with 12.7 mm diameter steel spheres at velocities ranging from 10 m/s to 100 m/s. Damage resistance of the specimens was determined through the use of dye penetrant enhanced x-radiography, sectioning, epoxy burnoff, and visual methods. Damage tolerance of the flat plate structures was assessed in a residual tensile test while damage tolerance of the cylinder structures was assessed via pressurization tests. Impacted fabric laminates exhibited matrix crushing, fiber breakage, delamination, and fiber bundle disbonds; the latter being a unique damage mode for fabric laminates. Plate delamination and bundle disbonding was found to be more extensive around the central core area of fiber damage in the coupon specimens than in the cylinder specimens which showed a cleaner damage area due to impact. Damage resistance and damage tolerance were predicted by utilizing a five-step analysis approach previously utilized for coupon configurations. Two of the five steps were adapted to account for the effects of the structural configuration of the pressurized cylinder. The damage resistance analysis provided good correlation to the fiber damage region of both the coupon and cylinder specimens. There was little difference in the size of this region in the two specimen types. However, the analysis was not able to predict the distribution of damage through-the-thickness. This was important in assessing the damage tolerance of the cylinders. The damage tolerance analysis was able to predict the residual tensile strength of the coupons. A general methodology to predict the impact damage resistance and damage tolerance of composite structures utilizing coupon data is presented.

Lagace, Paul A.↗

Finite element analysis of instability-related delamination growth

A parametric study of postbuckled through-width delaminations in laminated coupons was performed. A finite element analysis was developed to analyze the coupons as a combination of linear and geometrically nonlinear components. Because most of the coupon configuration studied behaves linearly, the mixed linear and nonlinear analysis greatly reduced computational costs. The analysis was verified by comparing numerical with exact solutions for simple hypothetical problems. In addition, measured lateral deflections of postbuckled through-width delaminations in laminated coupons were compared with predicted deflections. In the parametric study, stress distributions and strain-energy release rates were calculated for various delamination lengths, delamination depths, applied loads, and lateral deflections. Also, a small number of coupons with through-width delaminations were fatigue tested to obtain delamination growth data. Calculated strain-energy release rates were compared with the observed growth rates to determine the relative importance of the Mode 1 and Mode 2 components of energy release. Growth process was dominated by G sub I.

Whitcomb, J. D.↗

Test program to demonstrate the stability of hydrazine in propellant tanks

The suitability of stainless steels and Inconel for long-term hydrazine propellant-storage tanks is investigated. Rectangular coupon samples cut from propellent tanks were sealed with a measured amount of hydrazine in glass capsules, stored at 43 or 60 C, and removed after 6 to 24 months, when corrosion of the coupon and decomposition of the hydrazine was determined, and SEM and electron spectroscopy were performed on some coupons. Corrosion was found to be unmeasurably low for all the coupons, and hydrazine decomposition produced less than 1.0 cu cm of gas per sq cm of wetted surface per year, except in those few cases when catalysis or contamination were detected. Especially good stability was observed for type 304L stainless steel. The decomposition rates determined in the coupon tests are confirmed by preliminary results of actual tank storage trials.

Moran, C. M.↗

Measured and predicted structural behavior of the HiMAT tailored composite wing

A series of load tests was conducted on the HiMAT tailored composite wing. Coupon tests were also run on a series of unbalanced laminates, including the ply configuration of the wing, the purpose of which was to compare the measured and predicted behavior of unbalanced laminates, including - in the case of the wing - a comparison between the behavior of the full scale structure and coupon tests. Both linear and nonlinear finite element (NASTRAN) analyses were carried out on the wing. Both linear and nonlinear point-stress analyses were performed on the coupons. All test articles were instrumented with strain gages, and wing deflections measured. The leading and trailing edges were found to have no effect on the response of the wing to applied loads. A decrease in the stiffness of the wing box was evident over the 27-test program. The measured load-strain behavior of the wing was found to be linear, in contrast to coupon tests of the same laminate, which were nonlinear. A linear NASTRAN analysis of the wing generally correlated more favorably with measurements than did a nonlinear analysis. An examination of the predicted deflections in the wing root region revealed an anomalous behavior of the structural model that cannot be explained. Both hysteresis and creep appear to be less significant in the wing tests than in the corresponding laminate coupon tests.

Nelson, Lawrence H.↗

The development and evaluation of an alternative powder prepregging technique for use with LaRC-TPI/graphite composites

An alternative powder prepregging method for use with LaRC-TPI (a thermoplastic polyimide)/graphite composites is investigated. The alternative method incorporates the idea of moistening the fiber prior to powder coating. Details of the processing parameters are given and discussed. The material was subsequently laminated into small coupons which were evaluated for processing defects using electron microscopy. After the initial evaluation of the material, no major processing defects were encountered but there appeared to be an interfacial adhesion problem. As a result, prepregging efforts were extended to include an additional fiber system, XAS, and a semicrystalline form of the matrix. The semicrystalline form of the matrix was the result of a complex heat treating cycle. Using scanning electron microscopy (SEM), the fiber/matrix adhesion was evaluated in these systems relative to the amorphous/XAS coupons. Based on these results, amorphous and semicrystalline/AS-4 and XAS materials were prepregged and laminated for transverse tensile testing. The results of these tests are presented, and in an effort to obtain more information on the effect of the matrix, remaining semicrystalline transverse tensile coupons were transformed back to the amorphous state and tested. The mechanical properties of the transformed coupons returned to the values observed for the original amorphous coupons, and the interfacial adhesion, as observed by SEM, was better than in any previous sample.

Ogden, Andrea L.↗

The effects of specimen scale on the compression strength of composite materials

This paper presents a number of observations on the effect of specimen scale on the compression response of composite materials. Work on this topic was motivated by observations that thick-walled, unstiffened carbon reinforced cylinders subjected to hydrostatic pressure were not reaching inplane laminate stress levels at failure expected from coupon level properties, while similar cylinders reinforced with fiberglass were. Results from a study on coupon strength of (0/0/90) laminates, reinforced with AS4 carbon fiber and S2 glass fiber, are presented and show that compression strength is not a function of material or specimen thickness for materials that have the same laminate quality (autoclave cured quality). Actual laminate compression strength was observed to decrease with increasing thickness, but this is attributed to fixture restraint effects on coupon response. The hypothesis drawn from the coupon level results is further supported by results from a compression test on a thick carbon reinforced coupon in a fixture with reduced influence on specimen response and from a hydrostatic test on an unstiffened carbon reinforced cylinder subjected to hydrostatic pressure with end closures designed to minimize their effect on cylinder response.

Camponeschi, Eugene Thomas, Jr.↗

Isothermal Fatigue, Damage Accumulation, and Life Prediction of a Woven PMC

This dissertation focuses on the characterization of the fully reversed fatigue behavior exhibited by a carbon fiber/polyimide resin, woven laminate at room and elevated temperatures. Nondestructive video edge view microscopy and destructive sectioning techniques were used to study the microscopic damage mechanisms that evolved. The residual elastic stiffness was monitored and recorded throughout the fatigue life of the coupon. In addition, residual compressive strength tests were conducted on fatigue coupons with various degrees of damage as quantified by stiffness reduction. Experimental results indicated that the monotonic tensile properties were only minimally influenced by temperature, while the monotonic compressive and fully reversed fatigue properties displayed noticeable reductions due to the elevated temperature. The stiffness degradation, as a function of cycles, consisted of three stages; a short-lived high degradation period, a constant degradation rate segment composing the majority of the life, and a final stage demonstrating an increasing rate of degradation up to failure. Concerning the residual compressive strength tests at room and elevated temperatures, the elevated temperature coupons appeared much more sensitive to damage. At elevated temperatures, coupons experienced a much larger loss in compressive strength when compared to room temperature coupons with equivalent damage. The fatigue damage accumulation law proposed for the model incorporates a scalar representation for damage, but admits a multiaxial, anisotropic evolutionary law. The model predicts the current damage (as quantified by residual stiffness) and remnant life of a composite that has undergone a known load at temperature. The damage/life model is dependent on the applied multiaxial stress state as well as temperature. Comparisons between the model and data showed good predictive capabilities concerning stiffness degradation and cycles to failure.

Gyekenyesi, Andrew L.↗

Precision Cleaning of Oxygen Systems and Components

Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

McLaughlin, Russell↗

Approaches for Tensile Testing of Braided Composites

For angleply composites, lamina tension and compression strengths are commonly determined by applying classical lamination theory to test data obtained from testing of angleply composite specimens. For textile composites such as 2D triaxial braids, analysis is more complex and standard test methods do not always yield reliable strength measurements. This paper describes recent research focused on development of more reliable tensile test methods for braided composites and presents preliminary data for various approaches. The materials investigated in this work have 0deg+/-60 2D triaxial braid architecture with nearly equal fiber volume fraction in each of the three fiber directions. Flat composite panels are fabricated by resin transfer molding (RTM) using six layers of the braided preform aligned along the 0deg fiber direction. Various epoxy resins are used as matrix materials. Single layer panels are also fabricated in order to examine local variations in deformation related to the braid architecture. Specimens are cut from these panels in the shape of standard straight-sided coupons, an alternative bowtie geometry, and an alternative notched geometry. Axial tensile properties are measured using specimens loaded along the 0deg fiber direction. Transverse tensile properties are measured using specimens loaded perpendicular to the 0deg fibers. Composite tubes are also fabricated by RTM. These tubes are tested by internal pressurization using a soft rubbery material sealed between the inside diameter of the tube and the load fixtures. The ends of the tube are unconstrained, so the primary load is in the hoop direction. Tubes are fabricated with the 0deg fibers aligned along the tube axis by overbraiding the preform on a mandrel. Since the loading is in the hoop direction, testing of the overbraided tube provides a measure of transverse tensile strength. Previous work has indicated that straight-sided coupons yield a transverse tensile strength that is much lower than the expected material strength because of premature edge-initiated failure. Full-field strain measured during transverse tensile tests clearly showed accumulation of edge damage prior to failure. In the current work, high speed video and testing of single layer specimens are used to investigate potential failure mechanisms in more detail. High speed video clearly shows the edge initiation in six layer transverse tensile test coupons. Specimens with the bowtie geometry and the notched geometry minimize this edge effect and yield significantly higher transverse tensile strength values compared to the straight-sided coupons. However, bowtie and notched specimens geometries are not ideal because of the non-uniform stress and strain fields in the region of failure. Testing of tubes using internal pressurization eliminates edge-initiated failure and provides a more uniform state of stress and strain. Preliminary results indicate that bowtie, notched, and tube specimens yield comparable values for transverse tensile strength and that these values are much higher than the strength measured using a straight-sided coupon.

Roberts, Gary D.↗

Experimental Tests of UltraFlex Array Designs in Low Earth Orbital and Geosynchronous Charging Environments

The present ground based investigations give the first definitive look describing the expected on-orbit charging behavior of Orion UltraFlex array coupons in the Low Earth Orbital and Geosynchronous Environments. Furthermore, it is important to note that the LEO charging environment also applies to the International Space Station as well as to the lunar mission charging environments. The GEO charging environment includes the bounding case for all lunar orbital and lunar surface mission environments. The UltraFlex thin film photovoltaic array technology has been targeted to become the sole power system for life support and on-orbit power for the manned Aires Crew Exploration Vehicle. It is therefore, crucial to gain an understanding of the complex charging behavior to answer some of the basic performance and survivability issues in an attempt to ascertain that a single UltraFlex array design will be able to cope with the projected worst case LEO and GEO charging environments. Testing was limited to four array coupons, two coupons each from two different array manufactures, Emcore and Spectrolab. The layout of each array design is identical and varies only in the actual cell technology used. The individual array cells from each manufacturer have an antireflection layered coating and come in two different varieties either uncoated (only AR coating) or coated with a thin conducting ITO layer. The LEO Plasma tests revealed that all four coupons passed the arc threshold -120 V bias tests. GEO electron gun charging tests revealed that only front side area of ITO coated coupons passed tests. Only the Emcore AR array passed backside Stage 2 GEO Tests.

Galofaro, Joel T.↗

Survival of B. Horneckiae Spores Under Ground-simulated Space Conditions

To prevent forward contamination and maintain the scientific integrity of future life detection missions, it is important to characterize and attempt to eliminate terrestrial microorganisms associated with exploratory spacecraft and landing vehicles. Among the organisms isolated from spacecraft-associated habitats, spore-forming microbes are highly resistant to various physical and chemical conditions, which include ionizing and UV radiation, desiccation and oxidative stress, and the harsh environment of outer space or planetary surfaces. Recently a radiation resistant, spore forming bacterial isolate, Bacillus horneckiae, was isolated from a clean room of the Kennedy Space Center where the Phoenix spacecraft was assembled. The exceptionally high tolerance of extreme conditions demonstrated by sporeforming bacteria highlighted the need to assess the viability of these microbes in situ (in real) space. The proposed BOSS (Biofilm Organisms Surfing Space) project aims to understand the mechanisms by which biofilm forming organisms, such as B. horneckiae, will potentially be able to withstand harsh space conditions. As previously stated, the spore producing ability of these species gives them increased survivability to harsh conditions. Some of the spores will have the protective exosporium layer artificially removed before the test to determine if the existence of this layer significantly changes the survivability during the mission. In preparation for that experiment, we analyzed spores which were exposed during a ground simulation, the EXPOSE R2 Biofilm Organisms Surfing Space (BOSS). Previous to exposure, spores were deposited onto spacecraft grade aluminum coupons in a spore suspension calculated to contain between 10(exp 7) and 10(exp 8) spores. This precursor series will be used to establish a baseline survivability function for comparison with the future flight tests during EXPOSE-R. For each coupon, a 10% polyvinyl alcohol (PVA) film was applied and peeled from the coupon to recover the spores. One hundred μl of sterile 10% PVA was applied to the surface of the coupon and allowed to dry for 1 hour at 37 C. The films were then removed using sterile scalpel and forceps and placed into a glass test tube containing 2 milliliters of sterile deionized water. The PVA film process was then repeated on each coupon one additional time to ensure recovery of the majority of spores. The second PVA film was added in the same glass tube as in the previous round. If the spores remained 100% viable, the test tubes should now contain between 5 X 10(exp 6) and 5 X 10(exp 7) spores per millimeter; however, it is expected that some loss of viability has occurred. In order to assess this loss, the number of colony forming, viable spores was counted. To count the colony forming units (CFUs), the spore containing solution was diluted in a process of 10-fold serial dilution by mixing successive solutions in a 100 microliter spore suspension to 900 microliter deionized H2O ratio. A sample dilution series revealed that 10(exp -3) and 10(exp -4) concentrations would be necessary for an accurate CFU count to be taken. For those two concentrations, a spread on a TSA plate was prepared and incubated at 32 C. For the samples exposed to UV radiation, the cell survivability was too low to establish a count from 100 microliter spread plating. Instead, no dilutions were performed and the entire 2 milliliter spore suspension was plated and incubated at 32 C. The plate's CFU counts were taken at 24 hours and 48 hours from the time of plating. At the end of the CFU counting the total surviving spores in each sample were calculated based on the number of CFUs that were observed per 100 microliters, or per 2 milliliters for the UV irradiated samples. The results of these calculations are shown in Figures 1 and 2.

cleanroom↗

Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles of 0deg, 30deg, 45deg, 60deg and 90deg relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

Micromechanics↗

Experimental and Numerical Analysis of Triaxially Braided Composites Utilizing a Modified Subcell Modeling Approach

A combined experimental and analytical approach was performed for characterizing and modeling triaxially braided composites with a modified subcell modeling strategy. Tensile coupon tests were conducted on a [0deg/60deg/-60deg] braided composite at angles [0deg, 30deg, 45deg, 60deg and 90deg] relative to the axial tow of the braid. It was found that measured coupon strength varied significantly with the angle of the applied load and each coupon direction exhibited unique final failures. The subcell modeling approach implemented into the finite element software LS-DYNA was used to simulate the various tensile coupon test angles. The modeling approach was successful in predicting both the coupon strength and reported failure mode for the 0deg, 30deg and 60deg loading directions. The model over-predicted the strength in the 90deg direction; however, the experimental results show a strong influence of free edge effects on damage initiation and failure. In the absence of these local free edge effects, the subcell modeling approach showed promise as a viable and computationally efficient analysis tool for triaxially braided composite structures. Future work will focus on validation of the approach for predicting the impact response of the braided composite against flat panel impact tests.

Polymer Matrix Composites↗

Genesis Solar Wind Sample Curation Documentation

Introduction: A scientist with experience as a sample science analyst, provider of flight hardware for multiple missions, and senior engineer in an ISO 2000-rated manufacturing plant has described the timeline of key participants in any PI-led sample return mission, the breadth of the organizations involved [1,2], and, of interest to this meeting, choosing the types of data to preserve and issues of future data accessibility. This work broadens that perspective by giving similar lessons from Genesis sample curation point-of-view. Curation participation regarding data gathering was part of the mission review process from the beginning. Genesis’ story illustrates outcome of several choices about types of data to record and preserve. Precision analysis of solar wind atoms captured in pure, ultraclean substrates is the driving science goal; therefore, detailed documentation was captured from all mission and curation phases and from investigator laboratories because these processes affect the final analytical results [3]. Pre-flight: Design and fabrication of the spacecraft. Like many modern small sample return missions, Genesis was a tightly managed team integrated across science, engineering and curation. Communication across the team was excellent, and, for the most part, the hands-on engineering technicians understood the impacts of “small choices” they routinely make, and the eyes-on oversight of manufacturing processes by scientists was mindful of details. The payload was designed by the Jet Propulsion Laboratory and the spacecraft by Lockheed Martin. Solar wind collectors and instruments were fabricated by multiple vendors and laboratories. The main portion of the payload was assembled at JSC. Fabrication procedures and contamination-control data (with witness coupons) were stored primarily at JSC. The original composition, dimensions and configuration of components, results of thermal testing, etc. are still needed for interpretation of analytical data. At times, these must be estimated from secondary information acquired pre-flight. Moreover, some files (e.g., original 3-D models and early Powerpoint) cannot be opened using software. Archived curation data includes 2-D drawings, material usage lists, QA documentation and analyses of consumables used during fabrication. Important chemical information still resides in archived hardware, paints and lubricants, material coupons, cleaning coupons, environmental witness plates and reference materials from manufacturing facilities. Purity and cleanliness of collector substrates. Semi-conductor vendors provided surface cleanliness data and some purity data. Purity for specific elements of interest was verified by science team members in their laboratories [4]. Curation archived procurement and shipping records, analysis reports, and non-proprietary fabrication data. A physical archive of flight collector reference materials is maintained for future use so additional data can be collected as analytical techniques improve. These are of increased value due to the hard landing upon re-entry. Cleaning and cleanliness assessments of flight hardware. Cleaning of the science canister payload was performed at JSC in a dedicated ISO 4 cleanroom using ultrapure water (UPW). The cleanliness of this UPW was monitored throughout processing. The archive for the clean lab also includes airborne particle counts, airborne molecular and inorganic contamination measurements as well as cleanroom construction material coupons and witness coupons. Hardware cleanliness was assessed by particle counts in rinse water batches. This information is recorded in batch cleaning forms and logbooks, and are, perhaps, of decreased value due to the hard landing. Post-flight: Curation-generated data. The curation handling history of each Genesis sample is documented in a typical astromaterials sample database which captures sample location, physical description and characterization data. Samples have a “shelf life”. Crucial to the preservation of samples is ongoing documentation of the sample environment, initially under curatorial control but is now a separate facility function with requires coordination. PI-generated data. Data on sample characterization and cleaning techniques continues to be generated by sample users [5]. These are often captured in LPSC abstracts, but these “engineering” results often are not publishable as stand-alone papers. We are actively looking for ways to make this information more accessible to users. Ion implants into samples have aided science return and can be shared among investigators. These (and similar) materials should be added to the curatorial collection with appropriate process and characterization data generated externally. Summary: Complete data archives for returned astromaterial samples must be broad in types and formats, and inclusive of environmental monitoring.

Genesis↗

Broad Compatibility Study of Polymeric Materials with Ionic Silver Biocide, Part I

NASA is considering ionic silver as a residual biocide for use in potable water systems being planned for future exploration spacecraft. Compatibility of the biocide with the system’s wetted-materials of construction remains a challenge. Due to the relatively inert nature of plastics, their use in varied water system applications may offer unique opportunities to address many biocide compatibility issues. A 2020 ICES paper described a “Stage 1” assessment of several polymeric materials, in which coupons having a 2 cm 1 surface to volume ratio were exposed to solutions of 400 parts per billion (ppb) aqueous silver fluoride (AgF) for one week. In this current paper, additional Stage 1 test results are presented for select epoxies and lubricants applied on silver-inert substrates. The coupon exposure studies were also expanded to a duration of 5 weeks for the “well-behaved” Stage 1 plastics previously reported: those exhibiting silver losses above 10% and less than 50%. For this type of Stage 2 testing, silver biocide solution samples are taken from three separate (and not previously-sampled) coupon containers after 3 days, and 2, 3, 4, and 5 weeks of exposure. "Very well-behaved" Stage 1 plastics will be tested in the same manner over one year, with longer sample intervals; early-period results are included here. In addition, for select materials, the coupons were “aged” by refilling test containers with fresh AgF and observing the respective silver uptake over similar Stage 2 test durations. For all test series, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and ion-selective electrode (ISE) analyses were used to determine total and ionic silver (Ag+) concentrations, respectively. Additional sample analyses for Stage 2 tests includes total organic carbon (TOC), pH, conductivity, and oxidation-reduction potential (ORP). Ultimately, these early compatibility studies will be used to guide future material selections for developing silver biocide-compatible spacecraft water systems.

Silver Biocide↗