Search NASA⌕ Search

SEARCH · Search NASA

Results for “criticality testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Isolated Rotor Forward Flight Testing from One Atmosphere down to Martian Atmospheric Densities

With the recent interest in Martian exploration using Unmanned Aerial Vehicles (UAV), an experimental study was conducted to investigate rotor performance at Martian atmospheric conditions. Both simulation and testing of rotors is vital for the evaluation of performance and behavior of a rotor, especially when subjected to a Marian atmosphere. One critical test that has not been performed to date is simulated helicopter forward flight in a Martian atmosphere. To achieve this, the test must be conducted in a facility which can be evacuated to the atmospheric pressure and density of Mars. A unique 40-in diameter rotor, roughly approximating a proposed design for a Mars Helicopter (MH), was tested in forward flight at Mars atmospheric pressure at the NASA Ames Planetary Aeolian Laboratory (PAL). The goal of this experiment was to collect rotor thrust, RPM, power, torque, and acoustics measurements. Subsequently, these results are compared with simulated cases using a mid-fidelity Computational Fluid Dynamics (CFD) approach. As expected, rotor thrust and power results are drastically reduced when under low atmospheric conditions. In addition, Reynolds number effects seem to play a vital role that cannot be neglected.

Ament, Geoffrey A.↗

Evaluation of HEU-Beryllium Benchmark Experiments to Improve Computational Analysis of Space Reactors

An assessment was previously performed to evaluate modeling capabilities and quantify preliminary biases and uncertainties associated with the modeling methods and data utilized in designing a nuclear reactor such as a beryllium-reflected, highly-enriched-uranium (HEU)-O2 fission surface power (FSP) system for space nuclear power. The conclusion of the previous study was that current capabilities could preclude the necessity of a cold critical test of the FSP; however, additional testing would reduce uncertainties in the beryllium and uranium cross-section data and the overall uncertainty in the computational models. A series of critical experiments using HEU metal were performed in the 1960s and 1970s in support of criticality safety operations at the Y-12 Plant. Of the hundreds of experiments, three were identified as fast-fission configurations reflected by beryllium metal. These experiments have been evaluated as benchmarks for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Further evaluation of the benchmark experiments was performed using the sensitivity and uncertainty analysis capabilities of SCALE 6. The data adjustment methods of SCALE 6 have been employed in the validation of an example FSP design model to reduce the uncertainty due to the beryllium cross section data.

Bess, John↗

The simulation of time varying ascent loads on arrays of Shuttle tiles in a large transonic tunnel

A large variety of tests were made to determine the strength, fatigue and thermal characteristics of the thermal-protection system of the Shuttle orbiter. The present paper describes first-launch-critical tests which were conducted in the Langley 8-Foot Transonic Pressure Tunnel (8'TPT) which simulated the time histories of Shuttle ascent loads on tile arrays bonded to structures which accurately duplicated those of the Shuttle. The time varying free-stream conditions were provided by controlling the deflection angle history of diffuser spoiler flaps in an automated way. Time histories of the critical-load parameters imposed on the tile arrays in the tunnel are compared in the paper to those expected in flight. In addition, the effect of repeated load pulses on the smoothness of the surface and condition of the tiles is discussed briefly.

Bobbitt, P. J.↗

Analysis of stratospheric ozone, temperature, and minor constituent data

The objective of this research is to use available satellite measurements of temperature and constituent concentrations to test the conceptual picture of stratospheric chemistry and transport. This was originally broken down into two sub-goals: first, to use the constituent data to search for critical tests of our understanding of stratospheric chemistry and second, to examine constituent transport processes emphasizing interactions with chemistry on various time scales. A third important goal which has evolved is to use the available solar backscattered ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) data from Nimbus 7 to describe the morphology of recent changes in Antarctic and global ozone with emphasis on searching for constraints to theories. The major effort now being pursued relative to the two original goals is our effort as a theoretical team for the Arctic Airborne Stratospheric Expedition (AASE). Our effort for the AASE is based on the 3D transport and chemistry model at Goddard. Our goal is to use this model to place the results from the mission data in a regional and global context. Specifically, we set out to make model runs starting in late December and running through March of 1989, both with and without heterogeneous chemistry. The transport is to be carried out using dynamical fields from a 4D data assimilation model being developed under separate funding from this task. We have successfully carried out a series of single constituent transport experiments. One of the things demonstrated by these runs was the difficulty in obtaining observed low N2O abundances in the vortex without simultaneously obtaining very high ozone values. Because the runs start in late December, this difficulty arises in the attempt to define consistent initial conditions for the 3D model. To accomplish a consistent set of initial conditions, we are using the 2D photochemistry-transport model of Jackman and Douglass and mapping in potential temperature, potential vorticity space as developed by Schoeberl and coworkers.

Stolarski, Richard S.↗

IDGE - A test of dendritic growth theory using space flight

The isothermal Dendritic Growth Experiment (IDGE), to be performed on three of the United States Microgravity Payload (USMP) flights, starting with USMP-2, is designed to provide microgravity data on dendritic growth for a critical test of theory. Ground based test data using succinonitrile (SCN), from both a flight growth chamber and a laboratory growth chamber, are compared to theoretical calculations of dendritic tip velocities and radii. The comparison shows that the data from the flight chamber are consistent with the historical data and that dendritic growth in a microgravity environment should exhibit significant differences from the dendritic growth of SCN at g sub 0.

Glicksman, M. E.↗

Expanding Hardware-in-the-Loop Formation Navigation and Control with Radio Frequency Crosslink Ranging

The Formation Flying Testbed (FFTB) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility continues to evolve as a modular, hybrid, dynamic simulation facility for end-to-end guidance, navigation, and control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, are reviewed with a focus on recent improvements. With the most recent improvement, in support of Technology Readiness Level (TRL) 6 testing of the Inter-spacecraft Ranging and Alarm System (IRAS) for the Magnetospheric Multiscale (MMS) mission, the FFTB has significantly expanded its ability to perform realistic simulations that require Radio Frequency (RF) ranging sensors for relative navigation with the Path Emulator for RF Signals (PERFS). The PERFS, currently under development at NASA GSFC, modulates RF signals exchanged between spacecraft. The RF signals are modified to accurately reflect the dynamic environment through which they travel, including the effects of medium, moving platforms, and radiated power.

Mitchell, Jason W.↗

Beam dynamics simulations and measurements at the Project X Test Facility

Project X, under study at Fermilab, is a multitask high-power superconducting RF proton beam facility, aiming to provide high intensity protons for rare processes experiments and nuclear physics at low energy, and simultaneously for the production of neutrinos, as well as muon beams in the long term. A beam test facility - former known as High Intensity Neutrino Source (HINS) - is under commissioning for testing critical components of the project, e.g. dynamics and diagnostics at low beam energies, broadband beam chopping, RF power generation and distribution. In this paper we describe the layout of the test facility and present beam dynamics simulations and measurements.

43 PARTICLE ACCELERATORS↗

Brushless dc motors

Brushless dc motors were intensively developed and tested over several years before qualification as the prime movers for Apollo Spacecraft life support blowers, and for circulating oxygen in the lunar portable life support system. Knowledge gained through prototype development and critical testing has significantly influenced the technology employed, broadened markets and applications, and reduced the cost of present day motors.

Source record↗

Comment on 'The semiannual variation of great geomagnetic storms and the postshock Russell-McPherron effect preceding coronal mass ejecta' by N. U. Crooker, E. W. Cliver and B. T. Tsurutani

It is proposed by Crooker et al. (1992) that for a subgroup of great geomagnetic storms, for which the associated strong southward IMF (B(S)) fields reside in the postshock plasma, preceding the driver gas of coronal mass ejections, such strong B(S) fields result from a 'major increase in the Russell-McPherron polarity effect, through a systematic pattern of compression and draping' of the Archimedean field in the x-y plane. The critics test the scenario proposed by Crooker et al., namely, that the Russell-McPherron polarity effect is a major contribution to the semiannual variable of intense geomagnetic storms. It is found by the critics that in the cases studied there is little difference between the B(S) values as measured in geocentric solar ecliptic and geocentric solar magnetospheric coordinates, and it is concluded that the Russell-McPherron mechanism cannot explain by itself the seasonal dependence of intense storms, for which the variation is the largest. Crooker et al. present arguments to show that the combined preshock and postshock Russell-McPherron effect remains the sole cause of the semiannual variation of great storm occurrence.

Gonzalez, W. D.↗

Test of the inverse Compton model for Cygnus X-1

The unsaturated Compton model for Cygnus X-1 is attractive as it accounts for the power law spectrum with index (alpha) approximately equal to 1, and for the alleged high electron temperature (greater than 1 billion K). A critical test for the model is proposed, utilizing spectral data and especially the transition data when Cyg X-1 exhibited anticorrelated variations in soft and hard X-ray luminosities, with the pivoting point at about 10 keV; it is shown that the hard X-ray data available to date strongly support this model.

Liang, E. P. T.↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing Documentation of Critical Imaging Result Follow-up Recommendations in Emergency Department Discharge Instructions

To facilitate follow-up of critical test results across transitions in patient care settings, we implemented an electronic discharge module that enabled care providers to include follow-up recommendations in the discharge instructions. We assessed the impact of this module on documentation of follow-up recommendations for critical imaging findings in Emergency Department (ED) discharge instructions. We studied 240 patients with critical imaging findings discharged from the ED before (n = 80) and after (n = 160) implementation of the module. We manually reviewed hand-written forms and electronic discharge instructions to determine if follow-up recommendations were documented. Follow-up recommendations in ED discharge instructions increased from 60.0% (48/80) to 73.8% (118/160) post-module implementation (p = 0.03), a relative increase of 23%. There was no significant change in the rate of documented critical imaging findings in the discharge instructions (77.5% [62/80] before the intervention and 76.9% [123/160] after the intervention; p = 0.91). Implementation of a discharge module was associated with increased documentation of critical imaging finding follow-up recommendations in ED discharge instructions. However, one in four patients still did not receive adequate follow-up recommendations, suggesting further opportunities for performance improvement exist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aftbody Closure Effects on the Reference H Configuration at Subsonic and Transonic Speeds

Experience with afterbody closure effects and accompanying test techniques issues on a High Speed Civil Transport (HSCT)-class configuration is described. An experimental data base has been developed which includes force, moment, and surface pressure data for the High Speed Research (HSR) Reference H configuration with a closed afterbody at subsonic and transonic speeds, and with a cylindrical afterbody at transonic and supersonic speeds. A supporting computational study has been performed using the USM3D unstructured Euler solver for the purposes of computational fluid dynamics (CFD) method assessment and model support system interference assessment with a focus on lower blade mount effects on longitudinal data at transonic speeds. Test technique issues related to a lower blade sting mount strategy are described based on experience in the National Transonic Facility (NTF). The assessment and application of the USM3D code to the afterbody/sting interference problem is discussed. Finally, status and plans to address critical test technique issues and for continuation of the computational study are presented.

Wahls, Richard A.↗

Final Report

The specific aims of the research were two fold: 1) to test the working hypothesis that space flight can alter normal development of vestibular sense organs and 2) to characterize adaptation of vestibular receptors to weightlessness and readaptation upon the return to earth. The proposed research has two scientific objectives: 1) In hatchlings (and perhaps embryos): to critically test the hypothesis that space flight can modify the ontogeny of vestibular gravity receptors, and 2) In adult birds: to characterize adaptation of vestibular gravity receptors to weightlessness and further to characterize re-adaptation of vestibular gravity receptors upon their return to earth.

Jones, Timothy A.↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

TPSAS-NF1676L-32060-DND

All previous PSP testing done in the Unitary Plan Wind Tunnel (UPWT) have required a significant amount of manual operation of the system. This has resulted in decreased testing efficiency and precluded the ability to provide near real-time data analysis to the customer. The overall goal of this project is to integrate the PSP data acquisition system into the supersonic UPWT data acquisition system (DAS) and create an adaptive software platform from which PSP data acquisition can be triggered by the tunnel and critical testing conditions can be recorded in real time for rapid analysis of the PSP data. This analysis includes the mapping of up to eight camera views onto a surface grid for analysis and converting to pressure using parameters supplied by the DAS. To fully implement this solution, communication must first be established between the Unitary DAS and the PSP DAS. This will be done by employing multiple scripts written in Python and C++ and implemented on a Linux cluster. These will be demonstrated and refined on an upcoming test (December 2018), and the successful completion will result in the ability to have automatic collection of PSP images and near real-time analysis capabilities.

Juliette Eddins↗