At least 91 records · Page 5

Noise Erasure in Quantum-Limited Current Amplifiers

Superconducting quantum interference devices (SQUIDs) are extraordinarily sensitive to magnetic flux and thus make excellent current amplifiers for cryogenic applications. One such application of high interest to Sandia is the set-up and state read-out of quantum dot based qubits, where a qubit state is read out from a short current pulse (microseconds to milliseconds long) of approximately 100 pA, a signal that is easily corrupted by noise in the environment. A Parametric SQUID Amplifier can be high bandwidth (in the GHz range), low power dissipation (less than 1pW), and can be easily incorporated into multi-qubit systems. In this SAIL LDRD, we will characterize the noise performance of the parametric amplifier front end -- the SQUID -- in an architecture specific to current readout for spin qubits. Noise is a key metric in amplification, and identifying noise sources will allow us to optimize the system to reduce its effects, resulting in higher fidelity readout. This effort represents a critical step in creating the building blocks of a high speed, low power, parametric SQUID current amplifier that will be needed in the near term as quantum systems with many qubits begin to come on line in the next few years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two terminal current limiter

Two terminal device protects dc electronic circuits and experimental solid state devices, and replaces fuses and circuit breakers directly. The device consists of two transistors and two resistors and draws its necessary supply voltage from power source being protected. The limiter acts as a voltage regulator.

Doubt, L. S.↗

Limiting current in electron-beam welders

Damage to workpiece by excessive current in electron-beam welder is prevented by mechanism that accurately adjusts anode-to-cathode spacing. Mechanism is installed on standard Sciaky (or equivalent) electron-beam gun with only minimal modification. By turning knurled knob and observing digital readout of anode/cathode separation, machine operator adjusts welder for safe maximum current before welding begins.

Spiegel, K. W.↗

Current Limitations on VLBI Accuracy

The contribution of VLBI to geophysics and geodesy arises from its ability to measure distances between stations in a network and to determine the orientation of stations in the network as well as the orientation of the network with respect to the external reference frame of extragalactic radio objects. Integrating nearly two decades of observations provides useful information about station positions and velocities and the orientation of the Earth, but the complications of the real world and the limitations of observing, modeling and analysis prevent recovery of all effects. Of the factors that limit the accuracy of seemingly straightforward geodetic parameters, the neutral propagation medium has been subject to the greatest scrutiny, but the treatment of the mapping function, the wet component and spatial/temporal inhomogeneities is still improving. These affect both the terrestrial scale and consistency over time. The modeling of non-secular site motions (tides and loading) has increased in sophistication, but there are some differences between the models and the observations. VLBI antennas are massive objects, so their behavior is quite unlike GPS monuments, but antenna deformations add some (generally) unmodeled signal. Radio sources used in geodetic VLBI observations are selected for strength and (relative) absence of structure, but apparent changes in position can leak into geodetic parameters. A linear rate of change of baseline or site parameters is the simplest model and its error improves with time span. However, in most cases the VLBI data distribution is insufficient to look for real non-linear behavior that might affect the average rate. A few sites have multiple VLBI antennas, and some show small differences in rate. VLBI intrinsically measures relative positions and velocities, but individual site positions and velocities are generally more useful. The creation of the VLBI terrestrial reference frame, which transforms relative information into individual results, is an empirical process that has intrinsic errors. While UT1 is uniquely measured by VLBI, the geographical distribution and availability of VLBI stations, especially in the southern hemisphere, and the consistency of the VLBI terrestrial reference frame may limit the accuracy of Earth orientation measurements. The effects of particular error sources on geodetic and geophysical parameters derived from VLBI data will be illustrated.

Ma, Chopo↗

Linear and Nonlinear Analysis of Magnetic Bearing Bandwidth Due to Eddy Current Limitations

Finite element analysis was used to study the bandwidth of alloy hyperco50a and silicon iron laminated rotors and stators in magnetic bearings. A three dimensional model was made of a heteropolar bearing in which all the flux circulated in the plane of the rotor and stator laminate. A three dimensional model of a plate similar to the region of a pole near the gap was also studied with a very fine mesh. Nonlinear time transient solutions for the net flux carried by the plate were compared to steady state time harmonic solutions. Both linear and quasi-nonlinear steady state time harmonic solutions were calculated and compared. The finite element solutions for power loss and flux bandwidth were compared to those determined from classical analytical solutions to Maxwell's equations.

Kenny, Andrew↗

Blackstart of Power Grids with Inverter-Based Resources

This paper presents the findings of our investigation into inverter-based resource-(IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Using a Commercial Ethernet PHY Device in a Radiation Environment

This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.

Parks, Jeremy↗

Blackstart of Power Grids with Inverter-Based Resources: Preprint

This paper presents the findings of our investigation into inverter-based resource- (IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.

14 SOLAR ENERGY↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebraic expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

Current to a moving cylindrical electrostatic probe

The current collection characteristics of a moving cylindrical Langmuir probe are evaluated for a range of probe speeds and potentials which are applicable to earth and planetary measurements. The current expressions derived include the cases of the general accelerated current, sheath area limited current, orbital motion limited current, and retarded current. For the orbital motion limited current, a simple algebric expression is obtained which includes and generalizes the Mott-Smith and Langmuir expressions for both a stationary probe and a rapidly moving probe. For a rapidly moving probe, a single formula adequately represents both the accelerated and the retarded current.

Hoegy, W. R.↗

U.S. Manufacturing Water Use Data and Estimates: Current State, Limitations, and Future Needs for Supporting Manufacturing Research and Development

Water is essential to manufacturing operations; without it, many facilities could not operate or meet production demands. Physical, reputational, and regulatory risks to water supplies compounded by climate change-induced impacts on hydrological conditions threaten the adequacy of water supplies for manufacturing. Manufacturing water use has not been a major focus of either water or manufacturing-related research. Research and development (R&D) aimed at helping manufacturers use water more sustainably and adapt to changing water conditions is needed to ensure a thriving sector and economy. However, the ability to identify R&D needs is severely limited due to a lack of current, statistically representative data on manufacturing water use and its environmental implications. In this Perspective, we outline four key questions to inform R&D on manufacturing use and highlight how the current state of water data in the United States does not support the adequate investigation of these questions. We make recommendations for the water data characteristics needed to explore the research questions and knowledgeably inform R&D on manufacturing water use.

McCall, James↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

Characteristic parameters of superconductor-coolant interaction including high Tc current density limits

In the area of basic mechanisms of helium heat transfer and related influence on super-conducting magnet stability, thermal boundary conditions are important constraints. Characteristic lengths are considered along with other parameters of the superconducting composite-coolant system. Based on helium temperature range developments, limiting critical current densities are assessed at low fields for high transition temperature superconductors.

Frederking, T. H. K.↗

Hybrid circuit breakers

In one aspect, a hybrid circuit protection device for current-limiting a fault current between a source and a load during a fault is provided. The hybrid circuit protection device includes an input configured to couple to the source, an output configured to couple to the load, a return configured to couple the source to the load, a main switch configured to selectively couple the input to the output, a switching network coupled in parallel with the main switch, and a controller. The controller is configured to determine that the main switch has opened in response to the fault current, where the fault current has an initial value, and activate the switching network to current-limit the fault current to less than the initial value during the fault.