Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upscaling X-ray nanoimaging to macroscopic specimens

Upscaling X-ray nanoimaging to macroscopic specimens has the potential for providing insights across multiple length scales, but its feasibility has long been an open question. By combining the imaging requirements and existing proof-of-principle examples in large-specimen preparation, data acquisition and reconstruction algorithms, the authors provide imaging time estimates for howX-ray nanoimaging can be scaled to macroscopic specimens. To arrive at this estimate, a phase contrast imaging model that includes plural scattering effects is used to calculate the required exposure and corresponding radiation dose. The coherent X-ray flux anticipated from upcoming diffraction-limited light sources is then considered. This imaging time estimation is in particular applied to the case of the connectomes of whole mouse brains. To image the connectome of the whole mouse brain, electron microscopy connectomics might require years, whereas optimized X-ray microscopy connectomics could reduce this to one week. Furthermore, this analysis points to challenges that need to be overcome (such as increased X-ray detector frame rate) and opportunities that advances in artificial-intelligence-based `smart' scanning might provide. While the technical advances required are daunting, it is shown that X-ray microscopy is indeed potentially applicable to nanoimaging of millimetre- or even centimetre-size specimens.

97 MATHEMATICS AND COMPUTING↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

Object-space optimization of tomographic reconstructions for additive manufacturing

Volumetric 3D printing motivated by computed axial lithography enables rapid printing of homogeneous parts but requires a high dimensionality gradient-descent optimization to calculate image sets. Here we introduce a new, simpler approach to image-computation that algebraically optimizes a model of the printed object, significantly improving print accuracy of complex parts under imperfect material and optical precision by improving optical dose contrast between the target and surrounding regions. Quality metrics for volumetric printing are defined and shown to be significantly improved by the new algorithm. The approach is extended beyond binary printing to grayscale control of conversion to enable functionally graded materials. The flexibility of the technique is digitally demonstrated with realistic projector point spread functions, printing around occluding structures, printing with restricted angular range, and incorporation of materials chemistry such as inhibition. Finally, simulations show that the method facilitates new printing modalities such as printing into flat, rather than cylindrical packages to extend the applications of volumetric printing.

36 MATERIALS SCIENCE↗

Relaxing Direct Ptychography Sampling Requirements via Parallax Imaging Insights

Direct ptychography enables the retrieval of information encoded in the phase of an electron wave passing through a thin sample by deconvolving the interference effects of a converged probe with known aberrations. Under the weak phase object approximation, this permits the optimal transfer of information using noniterative techniques. However, the achievable resolution of the technique is traditionally limited by the probe step size—setting stringent Nyquist sampling requirements. At the same time, parallax imaging has emerged as a dose-efficient phase technique which relaxes sampling requirements and enables scan-upsampling. Here, we formulate parallax imaging as a quadratic approximation to part of the direct ptychography kernel and use this insight to enable upsampling in direct ptychography. We validate our analytical results numerically using simulated and experimental reconstructions.

direct ptychography, parallax imaging, scan Nyquis↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

An algorithm for neurite outgrowth reconstruction

We present a numerical method which provides the ability to analyze digitized microscope images of retinal explants and quantify neurite outgrowth. Few parameters are required as input and limited user interaction is necessary to process an entire experiment of images. This eliminates fatigue related errors and user-related bias common to manual analysis. The method does not rely on stained images and handles images of variable quality. The algorithm is used to determine time and dose dependent, in vitro, neurotoxic effects of 1 GeV per nucleon iron particles in retinal explants. No neurotoxic effects are detected until 72 h after exposure; at 72 h, significant reductions of neurite outgrowth occurred at doses higher than 10 cGy.

NASA Program Biomedical Research and Countermeasur↗

The Role of Surface Hydroxyls in Dehydration and Dehydrogenation of Formic Acid on Fe 3 O 4 (001)

Understanding the role of surface structure and hydroxylation in catalytic reactions on metal oxide surfaces is important for developing a mechanistic insight into the complex interface processes. Here, we investigate the reactivity of formic acid on reconstructed Fe 3 O 4 (001) using a combination of X-ray photoelectron spectroscopy, infrared reflection absorption spectroscopy, temperature-programmed reaction spectroscopy, low energy electron diffraction, and electronic structure calculations. We find that formic acid initially dissociates at low temperatures (< 80 K) into bidentate formate and a hydroxyl up to an initial dosed coverage of two HCOOH per Fe 3 O 4 (001) unit cell. At higher temperatures (> 450 K), formate largely decomposes along the dehydration pathway, producing CO and H 2 O, with dehydrogenation to CO 2 being a minority side reaction. As a first step, water formation leads to surface oxygen extraction via the Mars-van Krevelen mechanism. Computational studies reveal formate embedded in oxygen vacancies as a key intermediate in the CO formation mechanism. CO formation proceeds via two reaction pathways with desorption that peaks at 530 K on the hydroxyl-rich surface and 560 K on the hydroxyl-deficient surface. Atomic hydrogen coadsorption experiments and ab initio calculations reveal that the presence of surface hydroxyls reduces the CO formation barrier. Furthermore, these results highlight the complex interactions between substrate and intermediate species occurring during reactions on metal oxide surfaces.

Adsorption↗

Parallel evaluation of alternative skin barrier models and excised human skin for dermal absorption studies in vitro

Skin permeation is a primary consideration in the safety assessment of cosmetic ingredients, topical drugs, and human users handling veterinary medicinal products. While excised human skin (EHS) remains the ‘gold standard’ for in vitro permeation testing (IVPT) studies, unreliable supply and high cost motivate the search for alternative skin barrier models. In this study, a standardized dermal absorption testing protocol was developed to evaluate the suitability of alternative skin barrier models to predict skin absorption in humans. Under this protocol, side-by-side assessments of a commercially available reconstructed human epidermis (RhE) model (EpiDerm-200-X, MatTek), a synthetic barrier membrane (Strat-M, Sigma-Aldrich), and EHS were performed. The skin barrier models were mounted on Franz diffusion cells and the permeation of caffeine, salicylic acid, and testosterone was quantified. Transepidermal water loss (TEWL) and histology of the biological models were also compared. EpiDerm-200-X exhibited native human epidermis-like morphology, including a characteristic stratum corneum, but had an elevated TEWL as compared to EHS. The mean 6 h cumulative permeation of a finite dose (6 nmol/cm2) of caffeine and testosterone was highest in EpiDerm-200-X, followed by EHS and Strat-M. Salicylic acid permeated most in EHS, followed by EpiDerm-200-X and Strat-M. Altogether, evaluating novel alternative skin barrier models in the manner outlined herein has the potential to reduce the time from basic science discovery to regulatory impact.

60 APPLIED LIFE SCIENCES↗

Automatic parameter selection for electron ptychography via Bayesian optimization

Abstract Electron ptychography provides new opportunities to resolve atomic structures with deep sub-angstrom spatial resolution and to study electron-beam sensitive materials with high dose efficiency. In practice, obtaining accurate ptychography images requires simultaneously optimizing multiple parameters that are often selected based on trial-and-error, resulting in low-throughput experiments and preventing wider adoption. Here, we develop an automatic parameter selection framework to circumvent this problem using Bayesian optimization with Gaussian processes. With minimal prior knowledge, the workflow efficiently produces ptychographic reconstructions that are superior to those processed by experienced experts. The method also facilitates better experimental designs by exploring optimized experimental parameters from simulated data.

42 ENGINEERING↗

Growth and characterization of α-Sn thin films on In- and Sb-rich reconstructions of InSb(001)

α-Sn thin films can exhibit a variety of topologically nontrivial phases. Both studying the transitions between these phases and making use of these phases in eventual applications requires good control over the electronic and structural quality of α-Sn thin films. α-Sn growth on InSb often results in out-diffusion of indium, a p-type dopant. By growing α-Sn via molecular beam epitaxy on the Sb-rich c(4×4) surface reconstruction of InSb(001) rather than the In-rich c(8×2), we demonstrate a route to substantially decrease and minimize this indium incorporation. The reduction in indium concentration allows for the study of the surface and bulk Dirac nodes in α-Sn via angle-resolved photoelectron spectroscopy without the common approaches of bulk doping or surface dosing, simplifying topological phase identification. In this study, the lack of indium incorporation is verified in angle-resolved and angle-integrated ultraviolet photoelectron spectroscopy as well as in clear changes in the Hall response.

36 MATERIALS SCIENCE↗

Pulse Radiolysis Investigation of Radicals Derived from Water-Soluble Cyanine Dyes: Implications for Super-resolution Microscopy

Light-induced blinking, an inherent feature of many forms of super-resolution microscopy, has been linked to transient reduction of the fluorescent cyanine dye used as an imaging agent. There is, however, only scant literature information related to one-electron reduced cyanine dyes, especially in an aqueous environment. Here, we examine a small series of cyanine dyes, possessing disparate π-conjugation lengths, under selective reducing or oxidizing conditions. The experiment allows recording of both differential absorption spectra and decay kinetics of the resultant one-electron reduced or oxidized transient species in water. Relative to the ground state, absorption transitions for the various radicals are weak and somewhat broadened but do allow correlation with the π-conjugation length. In all cases, absorption maxima lie to the blue of the main ground-state transition. Under anaerobic conditions, the transient species decay on the microsecond to millisecond time scale, with the mean lifetime depending on molecular structure, radiation dose, and dye concentration. The experimental absorption spectra recorded for the one-electron reduced radicals and the presumed dimer cation radical compare well to spectra obtained from time-dependent density functional theory calculations. Furthermore, the results allow conclusions to be drawn regarding the plausibility of the reduced species being responsible for light-induced blinking in direct stochastic optical reconstruction microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-supervised physics-informed generative networks for phase retrieval from a single X-ray hologram

X-ray phase contrast imaging significantly improves the visualization of structures with weak or uniform absorption, broadening its applications across a wide range of scientific disciplines. Propagation-based phase contrast is particularly suitable for time- or dose-critical in vivo/in situ/operando (tomography) experiments because it requires only a single intensity measurement. However, the phase information of the wave field is lost during the measurement and must be recovered. Conventional algebraic and iterative methods often rely on specific approximations or boundary conditions that may not be met by many samples or experimental setups. In addition, they require manual tuning of reconstruction parameters by experts, making them less adaptable for complex or variable conditions. Here we present a self-learning approach for solving the inverse problem of phase retrieval in the near-field regime of Fresnel theory using a single intensity measurement (hologram). A physics-informed generative adversarial network is employed to reconstruct both the phase and absorbance of the unpropagated wave field in the sample plane from a single hologram. Unlike most state-of-the-art deep learning approaches for phase retrieval, our approach does not require paired, unpaired, or simulated training data. This significantly broadens the applicability of our approach, as acquiring or generating suitable training data remains a major challenge due to the wide variability in sample types and experimental configurations. The algorithm demonstrates robust and consistent performance across diverse imaging conditions and sample types, delivering quantitative, high-quality reconstructions for both simulated data and experimental datasets acquired at beamline P05 at PETRA III (DESY, Hamburg), operated by Helmholtz-Zentrum Hereon. Furthermore, it enables the simultaneous retrieval of both phase and absorption information.

36 MATERIALS SCIENCE↗

Nonmonotonic Band Flattening near the Magic Angle of Twisted Bilayer MoTe 2

Twisted bilayer MoTe 2 (tMoTe 2 ) is an emergent platform for exploring exotic quantum phases driven by the interplay between nontrivial band topology and strong electron correlations. Direct experimental access to its momentum-resolved electronic structure is essential for uncovering the microscopic origins of the correlated topological phases therein. Here, we report angle-resolved photoemission spectroscopy measurements of tMoTe 2 , revealing pronounced twist-angle-dependent band reconstruction shaped by orbital character, interlayer coupling, and moiré potential modulation. Density functional theory captures the qualitative evolution, yet underestimates key energy scales across twist angles, highlighting the importance of electronic correlations. Notably, the hole effective mass at the 𝐾 point exhibits a nonmonotonic dependence on twist angle, peaking near 2°, consistent with band flattening at the magic angle predicted by continuum models. Via electrostatic gating and surface dosing, we further visualize the evolution of electronic structure versus doping, enabling direct observation of the conduction band minimum and confirm tMoTe 2 as a direct band gap semiconductor. These results establish a spectroscopic foundation for modeling and engineering emergent quantum phases in this moiré platform.

2D materials↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

CO adsorption on MnO(100): Experimental benchmarks compared to DFT

In this study, CO adsorption on the MnO(100) surface was studied using temperature programmed desorption (TPD) and density functional theory (DFT). TPD results show that CO is weakly-bound on MnO(100), with an experimental adsorption energy of -35.6 ± 2.1 kJ/mol at terrace sites in the low coverage limit. PBE simulations suggest that CO adsorption causes an implausible (2 × 2) surface reconstruction. PBE+U simulations show no signs of surface reconstruction, and provide an accurate estimate of the adsorption energy (-36.4 kJ/mol) when combined with the DFT-D3 method with Becke-Jonson damping to correct for van der Waals interactions. This simulation also shows that CO adsorbs C-down onto the Mn 2+ terrace site in a tilted geometry, which is also observed experimentally and computationally on the similarly-structured NiO(100) transition metal oxide surface. TPD results for large doses show a plateauing of the coverage at about 0.4 monolayers of CO at 85 K, with a defect coverage equivalent to 0.08 monolayers. Adsorption associated with defect sites is indicated by a high-temperature desorption tail which is not satisfactorily explained by DFT simulations of simple step or oxygen vacancy defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗