Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronic loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Enhanced performance of Bi 2 S 3 /TiO 2 heterostructure composite films for solar cell applications

Day to day energy production is shifting towards renewable energy sources as these sources become more economically viable while being less polluting to operate; solar energy has become one of the major sources of renewable energy. However, it currently relies on ultra-pure silicon ingots to produce commercial silicon photovoltaics, which prevents the cost of electricity being produced to compete with non-renewable energy production. A viable low-cost alternative for silicon based cells would be dye-sensitized solar cells (DSSCs), which are easier and cheaper to manufacture as they do not require expensive and delicate raw materials to make. Moreover, they could be made semi-flexible which allows for a greater variety of applications. A DSSC consists of three components, a photo-electrode, an electrolyte and a counter-electrode. When exposed to incident light, the complex photosensitizers in the photoelectrode release electrons which are transported to the external load, leaving the photoelectrode in an oxidized state. The electrons are collected by the counter electrode and used to reduce the electrolyte. This charged electrolyte then reduces the positively charged photoelectrode, allowing the process to begin again. To improve the efficiency of this process, we explore the use of bismuth sulfide (Bi 2 S 3 ) and titanium oxide (TiO 2 ) composite as photoelectrode material and investigate their impact on the efficiency of DSSC.

14 SOLAR ENERGY↗

Thermal loading on self-seeding monochromators in x-ray free electron lasers

One approach to achieve longitudinally coherent hard X-ray free electron laser (XFEL) radiation is to introduce a single-crystal monochromator in the beam path to generate a co-propagating, time-synchronized self-seeding radiation pulse. For modern high-repetition rate XFELs, however, thermal loading on the crystal can degrade the quality of the seed pulse. To assess limitations on the maximum XFEL pulse repetition rate imposed by the seeding crystal, a comprehensive study of thermomechanical, and X-ray diffraction effects within the crystal is presented in this paper for two consecutive self-amplified spontaneous emission pulses incident on both reflective and transmissive crystal monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nucleation rate controlled grain boundary and lattice creep

Nucleation versus diffusion rate-limited bicrystal and single crystal creep exhibit different scaling dependencies that enable the mechanisms to be isolated when measured as a function of sample size. It has recently been suggested that nucleation rate-limited kinetic models generally describe the non-Newtonian portion of the creep response well, but more direct evidence is required. This work analyzes the grain boundary creep response of UO 2 , a pyrochlore high entropy oxide, silver, and palladium, along with the lattice creep of silver using small-scale in situ loading in the transmission electron microscope. At small sizes, each system exhibits scale dependence associated with nucleation rate-limited kinetics. Fits of the data produce activation volumes on the order of a few Burgers vectors cubed with positive temperature coefficients as expected for nucleation kinetics. The activation enthalpies fall in the range of about 0.4 eV to 1.7 eV, being lower for the metals and higher for the oxides.

36 MATERIALS SCIENCE↗

A review of active probing-based system identification techniques with applications in power systems

System identification is becoming a relevant research area for numerous applications in power grids due to the increasing complexity of the system. A paradigm shift in power system infrastructure driven by renewable energy resources, controllable loads, and new power electronics technologies have given rise to new challenges in power systems operation and control. This increased complexity of power systems and unavailability of physics-based models of most inverter-based resources requires that traditional modeling of power systems approaches be complemented by system identification-based black or grey box modeling techniques. In light of the importance of system identification and little attention paid to the applications of these techniques in transforming power systems, this paper provides a comprehensive review of active probing-based system identification methods in the context of power system applications. It reviews applications of both linear and nonlinear system identification with discussion on their potential and key takeaways. To motivate a further practical use in power systems, the paper provides an example of system identification, to develop a state space model of an unknown plant with step-by-step details. The paper highlights the advantages of using modern power electronics-based sources in the identification process and discusses the emerging research directions for future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deciphering the Conflict Between Ion and Electron Percolating Networks in Solid-State Battery Cathodes

High-energy- and power-density solid state batteries require an optimal cathode composition and microstructural arrangement of cathode active material, solid-state electrolyte, conductive carbon, and binder to simultaneously support lithium-ion transport, electron conduction, and storage capacity. The ion and electron conducting phases in solid-state cathodes counteract each other's percolating networks as their mass ratios increase or decrease relative to each other. Here, we investigate targeted mass ratio variations of argyrodite solid electrolyte and two different types of conductive carbon (particles and fibers) in composite LiNi0.8Mn0.1Co0.1O2 (NMC811) solid-state cathodes to ascertain the ionic-electronic tradeoffs in cathode performance. Through ionic and electronic conductivity measurements on composite cathodes, as well as rate-testing and cycling performance in full cells, it is shown that the conductive carbon fibers form a percolative electronic network within the composite at a lower mass ratio (3-5 wt%) than particulate carbon (>5 wt%). The threshold to achieve electronic percolation coincides with higher accessible capacity in the cathode as the active material particles become electronically connected. However, carbon loadings beyond this percolation threshold lead to increased ion transport resistance, arising from disruptions to ionic conduction pathways and degraded contact at the interface between the electrolyte and active materials. Imaging, spectroscopy, and physics-based models quantitatively describe the relationship between carbon and electrolyte compositions and the cell's capacity and rate performance through percolation theory. This work demonstrates the importance of quantitatively understanding percolating networks in solid-state cells and that strategic engineering of conductive carbon morphologies can further increase the energy- and power-density of solid-state cells.

25 ENERGY STORAGE↗

Functional Assessment of Shell Recharge Solutions' SKY™ Platform OpenADR Capability

The project’s overall objective is to research, develop, and conduct a wide-scale demonstration of a utility smart charge management (SCM) system to develop optimal managed charging structures for grid value, evaluate the impact of EV charging on local distribution utility operations, and evaluate the utilities’ ability to control electronic vehicle (EV) charging load based on grid conditions. This report covers Argonne’s validation testing in the first period of the project, the objective of which was to determine the current managed charging functionality of the EVSE hardware, the network and the vehicle telematics software solution and understand gaps that need to be addressed prior to a large-scale demonstration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Development of a High Fidelity Cyber-Physical Testbed

In order to ensure that future critical infrastructure systems are resilient to various types of such advanced and persistent threats, it is important to develop and integrate tailored solutions that holistically address cyber-attack detection and mitigation in a timely manner such that adverse system impacts that impact a large population are avoided. Further, it is essential to create environments that allow control, protection and communication to exist within a realistic environment to analyze the effects of adverse conditions and system operating modes. This project aims to establish a high-fidelity testbed environment for modeling and simulating a single microgrid all the way up to a network of microgrids along with baseline controls, protection, and associated cyber communication. This is an important activity because accurately modeling and simulating the various power-electronics-based DERs and loads in a microgrid is critical to adequately capturing their behaviors over a wide range of off-normal conditions, as well as to evaluate the resilience of the system using the developed controls. The work presented in this report focuses on the process of building this high-fidelity testbed and the associated experimentation it enables. The model enables the creation of high-fidelity use cases and associated datasets that have been used extensively within the initiative to study resilience and support novel control development and prototyping. The work heavily leverages existing capability that is part of the high-fidelity cyber-physical system experimentation lab to create a power hardware-in-the-loop setup. The report also details the creation of an automated model building platform that can enable high-fidelity real-time models to be built without much effort allowing existing low-fidelity models to be analyzed in higher fidelity. Lastly, the report also discusses efforts center around scaling to large complex power system models to make the experimentation more effective.

97 MATHEMATICS AND COMPUTING↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Better Use of On-Site PV Generation: Direct Distribution of DC Power in Buildings

With the increasing availability of Direct Current (DC) power from on-site solar systems, building designers now have the option of direct distribution of DC power to energy storage systems and end-use loads such as lighting, electronics, and motors. Research shows that direct-DC can reduce building distribution losses by 5-15%, while improving power reliability. A readily available way to implement direct-DC distribution is Power over Ethernet (PoE), which typically has provided low-voltage DC to power office equipment such as WiFi access points. With recent updates to the PoE standard, equipment such as network-controlled LED lighting, thin client and computer workstations, HVAC controllers, fans, motors, and actuators can now be powered by PoE and are commercially available. This paper presents results from a DOE-funded project that is demonstrating PoE technologies and describes a DC modeling and design tool that is intended to help building designers properly evaluate and design DC distribution systems in buildings. The tool provides designers of DC power systems with estimates of both power system losses and indirect effects on building heating and cooling. The results of this research demonstrate that the design methods and products are available to implement DC power in buildings today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tests of Cs-Free Operation of the SNS RF H⁻ Ion Sources

Tests were performed at SNS in collaboration with visiting colleagues from ISIS, UK to evaluate the uncesiated beam performance of the SNS RF H⁻ ion sources. Two spare experimental sources, one with internal antenna and one with external antenna were used for the tests. The beam currents achieved with Cs-free operations accounted for about 1/3 to 1/2 of the beam currents produced with cesiated operations. ~17 mA uncesiated H⁻ current was demonstrated within the tested RF power range up to 65 kW with the internal antenna source and ~15 mA with up to 40 kW RF with the external antenna source. In Cs-free operations, the power supply for the electron dumping electrode was loaded down below its set voltage but was not too drastic to tamper the operation.

Han, Baoxi↗

Positron Beam Loading and Acceleration in the Blowout Regime of a Plasma Wakefield Accelerator

Plasma wakefield acceleration in the nonlinear blowout regime has achieved marked milestones in electron beam acceleration, demonstrating high acceleration gradients and energy efficiency while preserving excellent beam quality. However, this regime is deemed unsuitable for achieving positron acceleration of comparable results, which is vital for future compact electron–positron colliders. In this article, we find that an intense positron beam loaded at the back of beam-driven blowout cavity can self-consistently induce the focusing field and flatten the longitudinal wakefield, leading to stable, high-efficiency, and high-quality positron acceleration. This is achieved through the formation of an on-axis electron filament induced by positron beam load, which shapes the plasma wakefield in a distinct way compared to electron beam load in the blowout regime. Via a nonlinear analytic model and numerical simulations, we explain the novel beam loading effects of the interaction between the on-axis filament and the blowout cavity. High-fidelity simulations show that a high-charge positron beam can be accelerated with >20% energy transfer efficiency, ~1% energy spread, and ~1 mm·mrad normalized emittance, while considerably depleting the energy of the drive beam. The concept can also be extended to simultaneous acceleration of electron and positron beams and high transformer ratio positron acceleration as well. This development offers a new route for the application of plasma wakefield acceleration into particle physics.

Science & Technology - Other Topics↗

Built-in Thermionic Electron Source for an SRF Linacs

The design of a thermionic electron source connected directly to a superconducting cavity, the key part of an SRF gun, is described. The results of beam dynamics optimization are presented which allow lack of beam current intercepting in the superconducting cavity. The electron source concept is presented including the cathode-grid assembly, thermal insulation of the cathode from the cavity, and the gun resonator design. The cavity thermal load caused by the gun is analyzed including the static heat load, black body radiation, backward electron heating, etc.

43 PARTICLE ACCELERATORS↗

Preprocessing for Unintended Conducted Emissions Classification with ResNet

Characterization of Unintended Conducted Emissions (UCE) from electronic devices is important when diagnosing electromagnetic interference, performing nonintrusive load monitoring (NILM) of power systems, and monitoring electronic device health, among other applications. Prior work has demonstrated that UCE analysis can serve as a diagnostic tool for energy efficiency investigations and detailed load analysis. While explaining the feature selection of deep networks with certainty is often not fully comprehensive, or in other applications, quite lacking, additional tools/methods for further corroboration and confirmation can help further the understanding of the researcher. This is true especially in the subject application of the study in this paper. Often the focus of such efforts is the selected features themselves, and there is not as much understanding gained about the noise in the collected data. If selected feature and noise characteristics are known, it can be used to further shape the design of the deep network or associated preprocessing. This is additionally difficult when the available data are limited, as in the case which the authors investigated in this study. Here, the authors present a novel work (which is a proposed complementary portion of the overall solution to the deep network classification explainability problem for this application) by applying a systematic progression of preprocessing and a deep neural network (ResNet architecture) to classify UCE data obtained via current transformers. By using a methodical application of preprocessing techniques prior to a deep classifier, hypotheses can be produced concerning what features the deep network deems important relative to what it perceives as noise. For instance, it is hypothesized in this particular study as a result of execution of the proposed method and periodic inspection of the classifier output that the UCE spectral features are relatively close to each other or to the interferers, as systematically reducing the beta parameter of the Kaiser window produced progressively better classification performance, but only to a point, as going below the Beta of eight produced decreased classifier performance, as well as the hypothesis that further spectral feature resolution was not as important to the classifier as rejection of the leakage from a spectrally distant interference. This can be very important in unpredictable low-FNR applications, where knowing the difference between features and noise is difficult. As a side-benefit, much was learned regarding the best preprocessing to use with the selected deep network for the UCE collected from these low power consumer devices obtained via current transformers. Baseline rectangular windowed FFT preprocessing provided a 62% classification increase versus using raw samples. After performing a more optimal preprocessing, more than 90% classification accuracy was achieved across 18 low-power consumer devices for scenarios in which the in-band features-to-noise ratio (FNR) was very poor.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic response of additively manufactured Ti–5Al–5V–5Mo–3Cr as a function of heat treatment

Both shock and shockless compression experiments were performed on laser powder bed fusion (LPBF) Ti–5Al–5V–5Mo–3Cr (Ti-5553) to peak compressive stresses near 15 GPa. Experiments were performed on the as-built material, containing a purely β (body centered cubic) microstructure, and two differing heat treatments resulting in a dual phase α (hexagonal close packed) and β microstructure. The Hugoniot, Hugoniot elastic limit (HEL), and spallation strength were measured and compared to wrought Ti-6Al-4V (Ti-64). The results indicate the LPBF Ti-5553 Hugoniot response is similar between heat treatments and to Ti-64. The HEL stress observed in the LPBF Ti-5553 was considerably higher than Ti-64, with the as-built, fully β alloy exhibiting the largest values. The spallation strength of the LPBF Ti-5553 was also similar to Ti-64. Clear evidence of initial porosity serving as initiation sites for spallation damage was observed when comparing computed tomography measurements before and after loading. Post-mortem scanning electron microscopy images of the recovered spallation samples showed no evidence of retained phase changes near the spall plane. The spall plane was found to have kinks aligned with the loading direction near areas with large concentrations of twin-like, crystallographic defects in the as-built condition. For the heat-treated samples, the concentrations of twin-like, crystallographic defects were absent, and no preference for failure at the interface between the α and β phases was observed.

36 MATERIALS SCIENCE↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Reevaluation of XPS Pt 4f peak fitting: Ti 3s plasmon peak interference and Pt metallic peak asymmetry in Pt@TiO2 system

The structural, electronic, and electrochemical properties of noble metals supported on transition metal oxides, such as Pt nanoparticles (NPs) supported on TiO2 (Pt@TiO2), have been extensively studied for their relevance to energy technologies, including photocatalysis, electrocatalysis, and electrochemical energy conversion. As the need to lower the amount of Pt and other noble metals used in energy conversion systems becomes urgent, it is essential to accurately quantify the loading of these metals and electronic density redistribution between them and their supports. X-ray photoelectron spectroscopy (XPS) is widely used for the identification and quantification of chemical species. In particular, fitting of the Pt 4f spectra for Pt@TiO2 is frequently performed to determine the chemical environment and oxidation state of Pt, which strongly affect the physical behavior and catalytic performance of this system. Here, we show that neglecting contributions due to the Pt surroundings and the asymmetry of the Pt metal peak in the line shape fitting can lead to severe mischaracterization of the oxidation state of Pt. We quantify the effects of background contributions that stem from the TiO2 support and discuss how factoring in the strong asymmetry of Pt 4f doublets, which stems from the shake-up type processes, affects the interpretation of Pt 4f XPS line shape.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗