Search NASA⌕ Search

SEARCH · Search NASA

Results for “flight tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

New particle pusher with hadronic interactions for modeling multimessenger emission from compact objects

We propose novel numerical schemes based on the Boris method in curved spacetime, incorporating both hadronic and radiative interactions for the first time. Once the proton has lost significant energy due to radiative and hadronic losses, and its gyroradius has decreased below typical scales on which the electromagnetic field varies, we apply a guiding center approximation (GCA). We fundamentally simulate collision processes either with a Monte-Carlo method or, where applicable, as a continuous energy loss, contingent on the local optical depth. To test our algorithm for the first time combining the effects of electromagnetic, gravitational, and radiation fields including hadronic interactions, we simulate highly relativistic protons traveling through various electromagnetic fields and proton backgrounds. We provide unit tests in various spatially dependent electromagnetic and gravitational fields and background photon and proton distributions, comparing the trajectory against analytic results. We propose that our method can be used to analyze hadronic interactions in black hole accretion disks, jets, and coronae to study the neutrino abundance from active galactic nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Nuclear Safety [Vol. 36, No. 2, July-December 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.

05 NUCLEAR FUELS↗

Nuclear Safety [Vol. 36, No. 2, July-December 1995]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Airport Delay Prediction with Temporal Fusion Transformers

Since flight delay hurts passengers, airlines, and airports, its prediction becomes crucial for the decision-making of all stakeholders in the aviation industry and thus has been attempted by various previous research. However, previous delay predictions are often categorical and at a highly aggregated level. To improve that, this study proposes to apply the novel Temporal Fusion Transformer model and predict numerical airport arrival delays at quarter hour level for U.S. top 30 airports. Inputs to our model include airport demand and capacity forecasts, historic airport operation efficiency information, airport wind and visibility conditions, as well as en-route weather and traffic conditions. The results show that our model achieves satisfactory performance measured by small prediction errors on the test set. In addition, the interpretability analysis of the model outputs identifies the important input factors for delay prediction.

Liu, Ke [University of California Berkeley]↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid isotopic analysis of uranium microparticles via SP-ICP-TOF-MS

Inductively coupled plasma – time-of-flight – mass spectrometry (ICP-TOF-MS) was employed for the isotopic analysis of uranium particles of varying 235 U enrichment levels. Here, a single particle (SP)-based introduction scheme was employed such that individual particles, in a suspension, were analyzed. The uranium oxide microparticles were comprised of depleted uranium (DU, 235 U/ 238 U of 0.0017316(14)), natural uranium (NU, 235 U/ 238 U of 0.0072614(39)), and low enriched uranium (LEU, 235 U/ 238 U of 0.051025(15)). The percent relative difference of the SP-ICP-TOF-MS measured isotopic ratios compared to the expected values for the DU, NU, and LEU particle populations were 8.75, 0.12, and 1.23 %, respectively. After characterization, the DU and NU particles were doped within a complex sample matrix (Arizona Test Dust) containing Fe, Ti, Al, and Si particles, among others. Then, the suspension was analyzed via SP-ICP-TOF-MS and the detected particles were classified as DU or NU based on their measured 235 U/ 238 U ratio. In the same analysis, the matrix particles (i.e., Al, Fe, and Ti) were detected, demonstrating the simultaneous nuclide detection provided by the measurement platform. The presented SP-ICP-TOF-MS methodology for uranium particle characterization proved to be a high throughput method for detecting and isotopically discerning uranium particles with varying enrichment levels, in a complex matrix.

Stanberry, Jordan S. [Oak Ridge National Laborator↗

Analysis of Polarized Dust Emission Using Data from the First Flight of SPIDER

Using data from the first flight of Spider and from the Planck High Frequency Instrument, we probe the properties of polarized emission from interstellar dust in the Spider observing region. Component-separation algorithms operating in both the spatial and harmonic domains are applied to probe their consistency and to quantify modeling errors associated with their assumptions. Analyses of diffuse Galactic dust emission spanning the full Spider region demonstrate (i) a spectral energy distribution that is broadly consistent with a modified-blackbody (MBB) model with a spectral index of β d = 1.45 ± 0.05 (1.47 ± 0.06) for E (B)-mode polarization, slightly lower than that reported by Planck for the full sky; (ii) an angular power spectrum broadly consistent with a power law; and (iii) no significant detection of line-of-sight polarization decorrelation. Tests of several modeling uncertainties find only a modest impact (~10% in σ r ) on Spider's sensitivity to the cosmological tensor-to-scalar ratio. The size of the Spider region further allows for a statistically meaningful analysis of the variation in foreground properties within it. Assuming a fixed dust temperature T d = 19.6 K, an analysis of two independent subregions of that field results in inferred values of β d = 1.52 ± 0.06 and β d = 1.09 ± 0.09, which are inconsistent at the 3.9σ level. Furthermore, a joint analysis of Spider and Planck 217 and 353 GHz data within one subregion is inconsistent with a simple MBB at more than 3σ, assuming a common morphology of polarized dust emission over the full range of frequencies. This evidence of variation may inform the component-separation approaches of future cosmic microwave background polarization experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Integrating Flow Imaging Analysis and Single-Particle ICP-TOFMS for Comprehensive Micro- and Nanoplastic Characterization

Flow imaging analysis (FIA), provides composition-agnostic morphological characterization. These measurements of particle size and shape are valuable to mass-based analysis, such as single particle inductively coupled plasma time-of-flight mass spectrometry (sp-ICP-TOFMS), which provides quantitative data on elements within particles. Using these two methods together enables informed use of geometric assumptions required by sp-ICP-TOFMS, as particle mass is typically converted to a particle diameter using assumed-spherical geometry. To validate this concept, parallel measurements to determine particle diameters were performed by FIA and sp-ICP-TOFMS on four particle suspensions: 300 nm polystyrene Eu-doped nanoparticles, 1 μm Fe-rich beads, 3 μm four element calibration polystyrene beads and 5 μm polystyrene beads. The Fe-particles obtained the highest percent difference from the manufacturer’s nominal diameter, as the mean diameter obtained by FIA was overestimated by 21% and sp-ICP-TOFMS underestimated the mean diameter by 20.7%. Two types of particles were selected to test the effect of varying the particle number concentrations (PNC) on sizing accuracy, and both methods accurately sized each particle population at the PNC expected. Single particle analysis of carbon has continued to be a popular research topic, with direct applications to environmental pollutants in terms of nano- and micro- plastics. Real-world plastic particles were studied, and FIA’s measured circularity values demonstrated that the particles deviated from spherical geometries, therefore sp-ICP-TOFMS data should be interpreted as mass-based rather than size-based. Combining these techniques enables improved interpretation of particle populations and evaluation of particle sizes.

Szakas, Sarah [ORNL] (ORCID:0000000241332197)↗

Stereo-vision thermal imaging system for tracking flying animals in wind farm areas (CRADA #763) Abstract

CRADA 763: abstract ThermalTracker-3D (TT3D) is a stereo vision thermal imaging system that provides 3D flight information on detected birds, bats, and other flying targets. The system was initially developed for use in the siting and monitoring of offshore wind projects to establish pre-construction and operation collision risk data but can be applied to terrestrial wind energy projects as well as national security monitoring. This technology will reduce monitoring cost, decrease processing time, and provide more accurate data for wind energy developers/operators and regulatory agencies. While the current technology is at a high level of readiness, Technology Readiness Level (TRL) 7, there remain several barriers to commercialization, particularly around ease-of-use, that result in a low Adoption Readiness Level (ARL). The proposed work will advance commercialization readiness by streamlining calibration methods for built systems. This work will:1. 1. develop a software package for factory and dynamic calibration processes 2. test that package with existing prototype TT3D systems, and 3. conduct outreach with industry end-users.

ThermalTracker↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗