Search NASASearch

SEARCH · Search NASA

Results for “heat flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

244 records · Page 5

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark

Cr plasma-material-interaction in PISCES-RF: D thermal release, retention, and erosion

Pure chromium (Cr) targets were exposed to high-flux deuterium (D) plasmas in the Pisces-RF linear plasma device, and measurements of D retention, release, and erosion were subsequently performed. Post-exposure D retention was quantified using temperature-programmed desorption on Cr targets irradiated by 50 eV ions over a broad range of exposure temperatures (423–873 K) and ion fluences (3 × 10 24 – 3 × 10 26 m −2 ). The retained D inventory was observed to decrease rapidly with increased exposure temperature, from approximately ∼7 × 10 20 m −2 at ∼ 420 K, to then saturate near ∼ 10 20 m −2 for exposure temperatures above ∼550 K. Separately, at fixed exposure temperature (∼450 K), D retention was found to have only a weak dependence on increasing ion fluence. Lastly, the erosion of Cr in D plasma was investigated for ion impact energies in the range 40 ≤ E i ≤ 250 eV. Erosion was inferred using optical emission spectroscopy (OES) from the ratio of emission lines (Cr I (425.4 nm)/D I (656.1 nm)) measured close to the target. Conversion of the OES yield data to net erosion yield was made with singular ion energy target mass-loss measurements. These net erosion yield data were then further corrected to obtain gross erosion yield by accounting for a re-deposition factor, computed using a simple model. The gross erosion yield is found to be 2–4 times lower than predicted by SDTrimSP, consistent with that typically observed for light-ion sputtering under high-flux plasma conditions.

Chromium

Ultrafast low-temperature metal–insulator interface phonon dynamics and heat transport in a Pt/Gd 3 Fe 5 O 12 heterostructure

Interfacial thermal and acoustic phenomena have an important role in quantum science and technology, including in spintronic and spincaloritronic materials and devices. Simultaneous measurements of the low-temperature thermal and acoustic properties of a metal/insulator heterostructure reveal distinct dynamics in the characteristic phonon frequency ranges of acoustic and thermal transport. The measurements probed a heterostructure consisting of a thin film of Pt on the ferrimagnetic insulator gadolinium iron garnet (Gd 3 Fe 5 O 12 , GdIG) grown epitaxially on a gadolinium gallium garnet substrate. Ultrafast structural dynamics within the Pt layer were tracked using time-resolved ultrafast x-ray diffraction and analyzed to probe interfacial acoustic and thermal properties. The rapid heating of the Pt layer by a 400 nm wavelength femtosecond-duration optical pulse produced transient structural changes that provided the stimulus for these measurements. Rapid heating produced a broadband acoustic pulse that was partially reflected by the Pt/GdIG interface. Temporal frequencies up to 740 GHz, corresponding to angular frequencies of several THz, were detected in a wavelet analysis of the acoustic oscillations of the strain in the Pt layer. The structural results were analyzed to determine (i) the acoustic damping coefficient and phonon mean free path in Pt at frequencies of hundreds of GHz and (ii) the Grüneisen anharmonicity parameter. The thermal conductance of the Pt/GdIG interface was tracked using the slower, tens-of-picosecond-scale, dynamics of the initial cooling of the heated Pt layer. Analysis using a model based on the Boltzmann transport equation shows that the phonon transmission is lower at the phonon frequencies relevant to thermal transport than for subterahertz regime acoustics.

Acoustic phenomena

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium

Laser-heated diamond anvil cell synthesis and recovery of metastable MnSb 2 and YbZn 2 for post-synthesis transport studies

The creation and exploration of new materials under extreme pressure–temperature conditions has become increasingly reliant on laser-heated diamond anvil cell (LHDAC) techniques, which provide direct access to previously unexplored regions of multinary phase diagrams. Whereas numerous high-pressure phases have been identified in situ, systematic recovery and post-synthesis physical property characterization of these materials remain significant challenges. In this work, we describe the setup and implementation of an LHDAC-based synthesis and recovery workflow and demonstrate its application to metastable MnSb 2 and YbZn 2 phases. Synchrotron x-ray diffraction and spatial mapping confirm dominant formation of the targeted phases, whereas laboratory-based refinement quantifies phase fractions despite intrinsic microstrain and minor secondary phases. High-pressure transport measurements on recovered samples reveal pressure-tunable electronic instabilities in both systems. In MnSb 2 , pressure suppresses two high-temperature magnetic ordering anomalies, observed in transport, by ∼5 GPa and, for higher pressures, induces a new low-temperature feature that increases with further pressure increase. In hexagonal high-pressure YbZn 2 , an electronic reconstruction emerges at ∼11 GPa, characterized by semiconducting-like behavior from ∼30 to 300 K and a broad low-temperature coherence crossover near 30 K. Our results establish LHDAC synthesis not only as a structural discovery tool but also as an experimental platform for investigating correlated quantum states stabilized far from equilibrium thermodynamic conditions.

Huyan, S. [Iowa State University, Ames, IA (United

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent

Time-Resolved Stochastic Dynamics of Quantum Thermal Machines

Steady-state quantum thermal machines are typically characterized by a continuous flow of heat between different reservoirs. However, at the level of discrete stochastic realizations, heat flow is unraveled as a series of abrupt quantum jumps, each representing an exchange of finite quanta with the environment. Here, in this work, we present a framework that resolves the dynamics of quantum thermal machines into cycles classified as enginelike, coolinglike, or idle. We analyze the statistics of individual cycle types and their durations, enabling us to determine both the fraction of cycles useful for thermodynamic tasks and the average waiting time between cycles of a given type. Central to our analysis is the notion of intermittency, which captures the operational consistency of the machine by assessing the frequency and distribution of idle cycles. Our framework offers a novel approach to characterizing thermal machines, with significant relevance to experiments involving mesoscopic transport through quantum dots.

full counting statistics

Nuclear Safety [Vol. 29, No. 3, July-September 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 259 Fifteenth Water Reactor Safety Information Meeting by E. G. Silver; CONTROL AND INSTRUMENTATION: 284 Reliability Technology to Improve and/or Maintain Emergency Diesel Generator Performance by S. Karimian and J. H. Taylor, 293 A Noise Diagnostics System for Operator Advice by G. Hessel, P. Liewers, P. Schumann, W. Schmitt, and F.-P. Weiss; PLANT SAFETY FEATURES: 307 A Passive Containment System for Advanced Light-Water Reactors by O. B. Falls, Jr., and F. W. Kleimola; ENVIRONMENTAL EFFECTS: 318 Data Base Construction for a Computerized Radiological Risk Investigation System by L. M. Hively, J. E. Nyquist, J. L. Bledsoe, and A. L. Sjoreen, 326 Erratum to "Radiation Hormesis and Nuclear Safety," Vol. 29, No. 1; OPERATING EXPERIENCES: 327 Operational Safety Experience and Passive Safety Testing at the Fast Flux Text Facility by Q. L. Baird, J. L. Rathbun, D. D. Stepnewski, R. L. Stover, and A. E. Waltar, 344 Backfilling of Independent Residual Heat Removal Systems in West Germany and Switzerland by G. Eckert and Y. Salomon, 353 Reactor Shutdown Experience Compiled by J. W. Cletcher, 356 Selected Safety-Related Events Compiled by G. A. Murphy, 363 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 384 General Administrative Activities Compiled by E. G. Silver, 390 Reports, Standards, and Safety Guides by D. S. Queener, 395 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 400 Proposed Rule Changes as of Mar. 31,1988; ANNOUNCEMENTS: 283 International ENS/ANS Conference on Thermal Reactor Safety "NUCSAFE 88", 317 Northwestern University Short Course on Radiation Safety, 407 Second International Seminar on Small- and Medium-Sized Nuclear Reactors, 407 International Workshop on New Developments in Occupational Dose Control and ALARA Implementation at Nuclear Power Plants and Similar Facilities, 408 Fourth International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), 404 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

The DESI Single Fiber Lens Search. I. Four Thousand Spectroscopically Selected Galaxy–Galaxy Gravitational Lens Candidates

We present 4110 strong gravitational lens candidates, 3887 of which are new discoveries, selected from a sample of 5,837,154 luminous red galaxies (LRGs) observed with the Dark Energy Spectroscopic Instrument (DESI). Candidates are identified via the presence of background ionized oxygen [O II ] nebular emission lines in the foreground LRG spectra, which may originate from the lensing of higher-redshift star-forming galaxies. Using the measured foreground redshift, background redshift, and integrated flux of the background [O II ] doublet, we integrate over impact parameters to compute the probability that each candidate is a lens. We expect 53% of candidates to be true lenses with Einstein radii ranging from 0$^{''}_.$1–4", which can be confirmed with high-resolution imaging. Confirmed strong lenses from this sample will form a valuable cosmological data set, as strong gravitational lensing is the only method to directly measure dark matter halo substructure at cosmological distances. We independently recover the host of the multiply imaged gravitationally lensed type Ia supernova iPTF16geu. Monitoring these lenses for future multiply lensed transients will enable (a) H 0 measurements via time-delay cosmography and (b) substructure measurements via flux ratios.

Karp, Juliana S. M. [Univ. of Washington, Seattle,

An Analysis of Energy Needs and Seawater Extraction Approaches for the Integration of Primary Magnesium Production with Nuclear Power

The cost of primary magnesium production is highly dominated by the energy required to produce the metal. This, along with the current geographical concentration of its production, makes the magnesium price vulnerable as energy-production paradigms begin to rapidly change. In this work, four nuclear-integration pathways for the efficient supply of heat and electricity to magnesium production from a nuclear power plant are considered. A production route using electrified metallothermic reduction is compared to a nuclear-heat-integrated electrolytic pathway. It is shown that the latter can achieve significantly lower primary energy consumption, 261 MJ/kg Mg compared with 416 MJ/kg Mg. The electrolytic pathway can also reduce emissions down to around 2.1 kgCO2/kg Mg, compared to around 34 kgCO2/kg Mg in the Pidgeon process. Beyond energy and emissions, the four pathways considered are also compared to their ability to reduce locational dependence of the production plant and reduce process complexity. This work also highlights future advances in magnesium production with a potential scheme for the efficient extraction of magnesium from seawater with coproduction of desalinated water and the potential of demand-side response from magnesium electrolysis. This is the first work to consider the full integration of primary magnesium production using nuclear cogeneration, and it is hoped the study paves the way for the analysis of economic nuclear integration within metal extraction and manufacturing.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Thermal Bekenstein-Hawking entropy from the worldsheet

We define and compute the leading sphere diagram contribution to the entropy of the BTZ black hole supported by Kalb-Ramond flux in bosonic string theory. In a winding condensate description, integrating exactly over the constant mode for the radial direction of AdS 3 reduces the problem to one of the correlation functions of winding operators in the free theory. The volume of the residual PSL(2,ℂ) gauge group of the sphere is canceled by the action of conformal transformations on the winding interaction insertions. We formulate a precise version of the replica trick in terms of (infinitesimally) non-integer winding condensates to produce the entropy of the BTZ black hole. The resulting entropy can be calculated from the one-point function of a non-local operator on the worldsheet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Software Validation Work With The ZPPR-15 Data

The analysis activities for fast reactors involve using many different pieces of software that are relied upon for their predictive capabilities. For this software to be considered reliable, documented proof that the predictions of the software are accurate is required. In this manuscript, the validation work that covers some of the Argonne software used in fast reactor design activities is discussed and displayed. This validation work includes neutron and gamma flux distributions, reaction rate distributions, and reactivity worth. In an ideal world, a reactor development program would have access to a comprehensive set of experimental facilities to help inform the design aspects of the reactor itself. While thermal-hydraulics experiments, and to a limited degree mechanical experiments, can be carried out today for validation needs, neutronics related experimental facilities are rather impractical because of the lack of experimental facilities. Given the desired time table for construction of new reactors, the reconstitution or creation of new neutronic experimental facilities is untenable and thus those reactor development programs must rely upon any available experimental measurements that are qualitatively similar to the design. While a methodology has been proposed to assess the similarity between the past experimental measurements and the reactor itself, that aspect is beyond the scope of this manuscript. In this manuscript, the focus is entirely placed on the analysis results for a series of experiments carried out at the ZPPR facility in Idaho in the mid-1980s. In this regard, this manuscript only shows the validation of the stated neutronics software for specific loadings of the ZPPR reactor. Because of the fuel form, its proposed enrichment, and the material content of the reactor core, the ZPPR-15 experiments were identified as potential validation data for the reactor. The ZPPR-15 experiments were intended as mockups of a 330 MWe Integral Fast Reactor program which was a follow on program to the Clinch River Breeder Reactor. In the ZPPR-15 series of experiments, measurements of the neutron spectrum, control rod worth, sodium void worth, foil reaction rate distributions, Doppler worth of heated samples, gamma dose, and axial expansion worth were all carried out and published. In many cases, these reactivity coefficients are good candidates to validate the reactivity coefficient calculation scheme used by the analysis software and included in the safety analysis activities of fast reactor development projects today. This manuscript discusses the modeling methodology and accuracy of the calculated experimental results using the LANL software MCNP and the ANL software package ARC (Argonne Reactor Codes). As will be shown, for many of the experimental measurements, the two software packages are found to be good predictive analysis tools for those experiments. In other cases, problems with the analysis methodology or underlying cross section data are exposed which indicates where predictive analysis is not as reliable. Finally, in some of the measurements the conclusion is reached that the experimental measurement cannot be reproduced with the analysis software as it is simply too difficult.

Aliberti, Gerardo

Evaluating alternative steam generation pathways in the food industry

Steam generation in the food sector requires substantial energy and cost expenditures, requiring nearly half of its energy intake. Here, we used life cycle assessment and life cycle cost assessment to investigate the cost and energy impacts of steam generating alternatives: NG, biomass and hydrogen boilers and grid-supplied and self-generated electric steam generation systems (electric boilers, renewable thermal energy storage and industrial heat pumps). The analysis starts with a set of average U.S. conditions, where biomass boilers are the most cost-competitive alternative to NG. In a series of scenarios beyond average conditions, the analysis shows energy procurement costs dominate the total life cycle cost for all technologies and, unfortunately, are highly variable geographically and temporally, significantly affecting the viability of the alternatives. Results show that site-energy consumption ranges from 0.3 MMBtu/klb for industrial heat pumps to 1.6 MMBtu/klb for biomass boilers, with heat pumps achieving up to 78% lower energy use compared to natural gas systems. For the steam costs, the results show a range between $\$$8 and $\$$50/klb for NG, with biomass following closely ($\$$11 – $\$$44/klb) and grey hydrogen and IHP next ($\$$13 – $\$$33/klb and $\$$6 - $\$$78/klb), with cost reductions if IHP's cooling is utilized. Factors like operating hours, the need for cooling, and the ability to negotiate utility rates complicate the decision, making site-specific analyses critical. Therefore, we present a decision-making matrix to help manufacturers identify which steam generating technology is the best business decision for their situation. Overall, these results highlight the importance of steam generation for the facility's organizational goals, as well as the criticality of conducting individual site analyses.

Biomass boilers

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)