Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared thermography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Transition measurements of upper and lower rotor blade surfaces in forward flight with thermography

Thermography allows for imaging the location of laminar-to-turbulent boundary layer transition on surfaces in air flows. The determination of BL transition of rotor blades was done in 2017 on the lower surface of a rotor blade in forward flight in the NASA Langley 14- by 22-Foot Subsonic Tunnel Subsonic Wind Tunnel. This article reports on the follow-on experiment in the same facility and the same blades where thermography was performed on both upper and lower surface synchronously, with the upper surface mapped throughout the full azimuthal range. Blade-tracking rotating mirrors were used for each thermal camera and were synchronized for simultaneous image acquisition. Furthermore, the Differential Infrared Thermography (DIT) technique depicts the unsteady nature of the BL transition in forward flight. Results are presented and discussed. These data are the first ever recorded of both surfaces of a rotor in forward flight.

Boundary layer transition↗

High-Temperature Sprayable Phosphor Coating Developed for Measuring Surface Temperatures

The use of phosphor thermography for noncontact temperature measurements in harsh environments has been proven over the last decade, but it has suffered from difficult application procedures such as vapor deposition or sputtering techniques. We have developed a high-temperature-sensitive paint that is easily applied with commercially available paint-spraying equipment and have successfully demonstrated it to temperatures up to 1500 C. Selected phosphors have also shown measurable signals to 1700 C, thus allowing a combination of phosphors to be used in high-temperature binders to make surface temperature measurements from ambient to over 1500 C. Phosphor thermography is an optical technique that measures the time response of fluorescence light, which is a function of the phosphor temperature. The phosphors are excited with short wavelength light (ultraviolet or blue), and they emit light at a longer wavelength. This technique has a benefit over other temperature measurements, such as thermocouples and infrared thermography, in difficult environments such as high blackbody backgrounds, vibration, flames, high electromagnetic noise, or where special windows may be needed. In addition, the sprayable phosphor paints easily cover large or complicated structures, providing full-surface information with a single measurement. Oak Ridge National Laboratories developed and tested the high-temperature binders and phosphors under the direction of the NASA Glenn Research Center. Refractory materials doped with rare earth metals were selected for their performance at high temperature. Survivability, adhesion, and material compatibility tests were conducted at high temperatures in a small furnace while the fluorescent response from the phosphors was being measured. A painted sample in a furnace with a clearly visible fluorescing dot excited by a pulsed laser is shown. Measuring the decay time of this fluorescence yields the surface temperature. One new paint was recently tested in a rocket test stand at Glenn. The floor of a square duct nozzle was painted, and full-field lifetime decay measurements were acquired for multiple firings of the rocket. Good agreement with predicted results was obtained, matching temperature gradients along the length of the nozzle and clearly showing shock structures. These good results were very satisfactory given that the measurements were made looking through the combustion plume. Infrared pyrometry was incapable of making the surface measurements because of the interference from the rocket exhaust, which contaminated the infrared signature.

Bencic, Timothy J.↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

Film Cooling Effectiveness Measurements on a CMC-Simulated Flat Plate

Ceramic matrix composites (CMC) are high temperature materials that can allow higher operating turbomachinery engine temperatures with less coolant required. One method of fabricating ceramic matrix composites is by weaving fibers into the shape of an airfoil. Generally, CMC fiber tows are assembled with various weave patterns, but this uneven surface could introduce aerodynamic losses, and it will be necessary to determine the best film cooling hole arrangement for minimal thermal engine efficiency loss. As part of an effort to assess the impact of geometric constraints of CMC implementation relative to metallic high pressure turbine blades, an experimental study was performed to investigate the effect of film cooling on a CMC-like surface roughened flat plate. Film cooling effectiveness measurements were acquired on a large-scale surface with a ceramic matrix composite weave pattern and on a smooth surface for comparison. A single row and a 2-row cooling hole arrangement were investigated with different hole sizes. Infrared thermography data was acquired at several Reynolds numbers and blowing ratios. Results showed that the effect on span averaged film cooling effectiveness was small between a weave surface pattern and a smooth surface, while hole spacing dependence had a much stronger effect.

infrared↗

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Cr-Doped GdAlO3 Phosphor Thermography

It has been recently shown that the high luminescence intensity from a Cr-doped GdAlO3 (Cr:GdAlO3) thermographic phosphor enables non-rastered full-field temperature mapping of thermal barrier coating (TBC) surfaces to temperatures above 1000C. In this presentation, temperature mapping by Cr:GdAlO3 based phosphor thermometry of air film-cooled TBC-coated surfaces is demonstrated for both scaled-up cooling hole geometries as well as for actual components in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and advantages of this method over infrared thermography as well as the limitations of this method for studying air film cooling are discussed.

thermographic phoshor↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 -- 15.8 x 10^6 m^{-1}. Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10 x 10^6 m^{-1} in quiet flow, while transition was already observed on the shoulders below 5 x 10^6 m^{-1} in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 x 10^6 m^{-1} quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Preliminary Measurements on the BOLT Geometry in the Supersonic Low Disturbance Tunnel

Experiments were performed in the Mach 3.5 Supersonic Low Disturbance Tunnel on the BOundary-Layer Transition (BOLT) geometry. The goal of this campaign was to assess changes to the transition front by varying the freestream noise and the model surface quality. The model was printed of polycarbonate and is 30% scale of the flight geometry. It was tested under noisy and quiet conditions at different streamwise positions in the tunnel and was also tested before and after improvements were made to the model surface through sanding and gap reduction. Pitch and yaw angles were nominally zero. The model surface temperature was measured using infrared thermography and thermocouples as the unit Reynolds number was swept from 4.75 – 15.8 × 10 6 m −1 . Boundary-layer transition was observed near the midspan of the model for unit Reynolds numbers above 10×10 6 m −1 in quiet flow, while transition was already observed on the shoulders below 5×10 6 m −1 in noisy flow. The model surface enhancements improved the symmetry of the transition front for quiet flow but made only slight differences for noisy flow. In quiet flow, the impact of streamwise positioning on transition was more significant on the model shoulders compared to the central region. The difference in the shoulder heating was likely due to variation in noise radiated from the nozzle sidewalls. The total temperature and initial wall temperatures were near 300 K and 293 K, respectively, which generally resulted in negative convective heat-flux values into the model. Hot-wire anemometry was also utilized to characterize the freestream and to conduct a planar survey near the base of the model for the 7.92 × 10 6 m −1 quiet condition. The survey captured the thickening of the boundary layer at the centerline and the vortical nature of the flow outboard of it. Spectral analysis of the mass-flux fluctuations near the midspan demonstrates that the boundary layer is laminar and suggests that the thick boundary layer caused the relatively warm centerline observed in the infrared images.

boundary layer transition↗

Porosity Measurement in Laminated Composites by Thermography and FEA

This paper presents the correlation between the through-thickness thermal diffusivity and the porosity of composites. Finite element analysis (FEA) was used to determine the transient thermal response of composites that were subjected to laser heating. A series of finite element models were built and thermal responses for isotropic and orthographic materials with various thermal diffusivities subjected to different heating conditions were investigated. Experiments were conducted to verify the models and to estimate the unknown parameters such as the amount of heat flux. The analysis and experimental results show good correlation between thermal diffusivity and porosity in the composite materials. They also show that both laser and flash heating can be used effectively to obtain thermal diffusivity. The current infrared thermography system is developed for use with flash heating. The laser heating models and the FEA results can provide useful tools to develop practical thermal diffusivity measurement scheme using laser heat.

Chu, Tsuchin Philip↗

Effect of Roughness on Transition on the BOLT-1a Geometry in Supersonic Flow

Infrared thermography measurements on an 8.8% scale BOLT-1a model were made in the NASA Langley Probe Calibration Tunnel for freestream unit Reynolds numbers from 7.7 × 10^ -6 /m to 30.7 × 10^ -6 /m, a freestream Mach number of 3.5, and nominal angle of attack of 0 degrees. The model was printed from polycarbonate and tested before and after fine-grit sanding to evaluate the effect of surface roughness on transition. Global surface roughness measurements were obtained using a 3D optical profilometer. The temperature distributions on the upper and lower experimental surfaces of the test article were simultaneously captured using two infrared cameras. Prior to testing, the facility’s freestream environment was characterized. At a freestream unit Reynolds number of approximately 17 × 10^ -6 /m, the nozzle-wall boundary layer began to transition non-uniformly, inducing transition on the model. The boundary-layer state was determined by analyzing Stanton number distributions computed from the surface temperature measurements. The present supersonic conditions that were examined on BOLT-1a were found to display both similarities and disparities in comparison to previous hypersonic experiments.

boundary layer transition↗

Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of High Temperature Composite Materials

The increased use of high-temperature composite materials in modern and next generation aircraft and spacecraft have led to the need for improved nondestructive evaluation and health monitoring techniques. Such technologies are desirable to improve quality control, damage detection, stress evaluation and temperature measurement capabilities. Novel eddy current sensors and sensor arrays, such as Meandering Winding Magnetometers (MWMs) have provided alternate or complimentary techniques to ultrasound and thermography for both nondestructive evaluation (NDE) and structural health monitoring (SHM). This includes imaging of composite material quality, damage detection and .the monitoring of fiber temperatures and multidirectional stresses. Historically, implementation of MWM technology for the inspection of the Space Shuttle Orbiter Reinforced Carbon-Carbon Composite (RCC) leading edge panels was developed by JENTEK Sensors and was subsequently transitioned by NASA as an operational pre and post flight in-situ inspection at the Kennedy Space Center. A manual scanner, which conformed'automatically to the curvature of the RCC panels was developed and used as a secondary technique if a defect was found during an infrared thermography screening, During a recent proof of concept study on composite overwrapped pressure vessels (COPV's), three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed excellent correlation with actual surface strain gage measurements. Recent advancements of this technology have been made applying MWM sensor technology for scanning COPVs for mechanical damage. This presentation will outline the recent advance~ in the MWM.technology and the development of MWM techniques for NDE and SHM of carbon wra~ped composite overwrapped pressure vessels (COPVs) including the measurement of internal stresses via a surface mounted sensor array. In addition, this paper will outline recent efforts to produce sensors capable of making real-time measurements at temperatures up to 850 C, and discuss previous results demonstrating capability to monitor carbon fiber temperature changes within a composite material.

Russell, Richard↗

Preliminary proof-of-concept of real-time divertor heat flux control from infrared cameras with nitrogen injection in the DIII-D tokamak

In future tokamak reactors like ITER and the Fusion Pilot Plant (FPP), real-time feedback control of heat flux to the plasma-facing components (PFC) will be critical for steady-state operation. This work presents the first experimental demonstration of real-time divertor heat flux estimation with infrared thermography and feedback control with impurity seeding on the DIII-D tokamak. The flexible infrastructure of the Plasma Control System (PCS) on DIII-D makes this new capability possible. The PCS software runs on a gateway computer system, and five real-time compute nodes. An array of low latency streaming digitizers from D-TACQ Solutions connects to these real-time computers to collect and process data, and send commands to actuators during plasma discharges. This system handles the signal IO from the tokamak and allows the PCS to utilize the diagnostic data necessary to perform control in real-time. Feedback control on heat flux was accomplished by feeding infrared camera data from the “Infrared TV” (IRTV) camera to a custom-developed User Datagram Protocol (UDP) server. This server transmits infrared data to a newly developed PCS algorithm that estimates the heat flux to PFC. Here, a proportional integral derivative (PID) controller minimizes the error between a heat flux reference and the real-time estimate by injecting nitrogen gas into the divertor.

Algorithm development↗

Infrared On-Orbit RCC Inspection With the EVA IR Camera: Development of Flight Hardware From a COTS System

In November 2004, NASA's Space Shuttle Program approved the development of the Extravehicular (EVA) Infrared (IR) Camera to test the application of infrared thermography to on-orbit reinforced carbon-carbon (RCC) damage detection. A multi-center team composed of members from NASA's Johnson Space Center (JSC), Langley Research Center (LaRC), and Goddard Space Flight Center (GSFC) was formed to develop the camera system and plan a flight test. The initial development schedule called for the delivery of the system in time to support STS-115 in late 2005. At the request of Shuttle Program managers and the flight crews, the team accelerated its schedule and delivered a certified EVA IR Camera system in time to support STS-114 in July 2005 as a contingency. The development of the camera system, led by LaRC, was based on the Commercial-Off-the-Shelf (COTS) FLIR S65 handheld infrared camera. An assessment of the S65 system in regards to space-flight operation was critical to the project. This paper discusses the space-flight assessment and describes the significant modifications required for EVA use by the astronaut crew. The on-orbit inspection technique will be demonstrated during the third EVA of STS-121 in September 2005 by imaging damaged RCC samples mounted in a box in the Shuttle's cargo bay.

Gazanik, Michael↗

Infrared On-Orbit Inspection of Shuttle Orbiter Reinforced Carbon-Carbon Using Solar Heating

Thermographic nondestructive inspection techniques have been shown to provide quantitative, large area damage detection capabilities for the ground inspection of the reinforced carbon-carbon (RCC) used for the wing leading edge of the Shuttle orbiter. The method is non-contacting and able to inspect large areas in a relatively short inspection time. Thermal nondestructive evaluation (NDE) inspections have been shown to be applicable for several applications to the Shuttle in preparation for return to flight, including for inspection of RCC panels during impact testing, and for between-flight orbiter inspections. The focus of this work is to expand the capabilities of the thermal NDE methodology to enable inspection by an astronaut during orbital conditions. The significant limitations of available resources, such as weight and power, and the impact of these limitations on the inspection technique are discussed, as well as the resultant impact on data analysis and processing algorithms. Of particular interest is the impact to the inspection technique resulting from the use of solar energy as a heat source, the effect on the measurements due to working in the vacuum of space, and the effect of changes in boundary conditions, such as radiation losses seen by the material, on the response of the RCC. The resultant effects on detectability limits are discussed. Keywords: Nondestructive Evaluation, Shuttle, on-orbit inspection, thermography, infrared

Howell, P. A.↗

Spatiotemporal Thermal Coupling in VO 2 Device Arrays

Correlated oxides such as VO 2 exhibit an electrically driven insulator–metal transition (IMT) that underlies their promise for neuromorphic and memory devices. Yet the IMT is not a uniform bulk process but a spatiotemporal phenomenon in which local heating nucleates filaments, contracts or dissolves them with the electric field, and couples to the environment. In this work, we directly image the VO 2 IMT dynamics by mid-wave infrared, thermography synchronized with electrical transport, resolving device temperature with micrometer spatial and microsecond temporal resolution. At the single-device level, we capture the full cycle of filament nucleation, contraction, and relaxation during current/voltage-driven resistive switching. At the array level, we show that heat propagates across etched gaps with an effective length scale of ∼131 µm, enabling cooperative behaviors among electrically isolated devices. Short-range distanced devices exhibit mutual filament attraction and sequential dissolution, while long-range distanced devices differentiate into distinct roles: drivers that initiate switching, cooperative responders that undergo assisted self-oscillations, and passive reporters that record the thermal field. Furthermore, these results reframe thermal crosstalk, long regarded as parasitic, as an intrinsic coupling channel and design principle for organizing collective switching behaviors, with direct implications for emergent circuit functionality in neuromorphic and unconventional computing architectures.

coupling↗

Large-scale additive manufacturing of self-heating molds

Large-scale material extrusion additive manufacturing technology is becoming the new mainstream technology for scaled-up composite mold and die applications. This paradigm shift in composite processing technology is primarily driven by out-of-autoclave tooling applications, in which fiber reinforced composite molds with scaled-up sizes and embedded heating elements are attractive. The present research describes the design, manufacturing, and testing of self-heating composite molds fabricated via a large-scale pellet extrusion 3D printing machine with an integrated wire co-extrusion tool. Polycarbonate (PC) composites reinforced with carbon fiber (PC/CF; 20 wt.%) and glass fiber (PC/GF; 20 wt.%) were used to fabricate mold parts. Joule heating thermal test results showed that uniform temperatures (~100 °C) were achieved for both PC/CF and PC/GF mold surfaces, using a custom-made feedback control power supply and infrared thermography. Mechanical characterizations, including tensile and flexural testing were performed on the wire-embedded and un-wired PC/CF and PC/GF base specimens to investigate the impact of the fiber reinforcement as well as the embedded wires. In the direction of extrusion, the ultimate tensile stress of PC/CF was 105 MPa, and that of PC/GF was 73 MPa, while the neat PC value was 64 MPa. Inner-bead voids and interfacial gaps were observed and characterized via optical and scanning electron microscopy. The embedded wires and inner bead impacted the mechanical properties of the composites. Furthermore, the stiffness of the wire-embedded mold was still satisfactory, proving that the technology can be used to fabricate additively manufactured out-of-oven/autoclave molds.

36 MATERIALS SCIENCE↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗