Search NASA⌕ Search

SEARCH · Search NASA

Results for “laminate modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Process model for multilayer slide coating of polymer electrolyte membrane fuel cells

Slide coating is a precision method suitable for depositing multiple liquid-film layers simultaneously. Originally developed in the photographic film industry, it has been deployed for manufacturing of other products that benefit from multilayer coatings. One emerging application is the manufacture of polymer electrolyte membrane fuel cells (PEMFCs), which are used to produce electricity through electrochemical reactions of hydrogen and oxygen gas. The membrane-electrode assembly (MEA), in which key electrochemical reactions occur, consists of three layers that are typically deposited separately in serial fashion and then laminated together to form the three-layer MEA, i.e., three sequential steps of coat and dry. Adapting the process to simultaneous, multilayer slide coating of all three layers will save equipment cost and space while minimizing possible exposure to contaminants during transition between the steps. We are developing a three-layer slide coating model to aid the manufacturing process design of PEMFC. The model accounts for rheology of each layer, which typically exhibit shear thinning behavior. Model predictions are used to investigate simultaneous coatability of catalyst inks and to determine the best layer-by-layer ink selection.

25 ENERGY STORAGE↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Thermal Management Solution for an Integrated Outer-Rotor Motor Drive: Opportunities and Challenges

This work highlights an integrated thermal management solution for the outer-rotor motor (ORM) drive. The integrated ORM drive utilizes water-ethylene glycol coolant for power electronics and stator cooling. Air cooling is used for rotor laminations, magnets and outer-rotor structures, and the rotor shaft. To fully understand the performance of the integrated ORM drive and thermal management coupling effects, a full drive conjugate heat transfer model has been developed to investigate coupled cooling performance of various components of the ORM drive. Various motor rotational speeds, power output scenarios, and cooling options for the integrated ORM drive have been investigated. The model estimates the operating window for the ORM drive while keeping component operating temperatures below prescribed limits. The model also highlights the importance of windage losses at higher rotational speeds for this ORM design, which involves higher rotor surface area per unit width of the rotor. Different designs are also investigated, particularly focusing on rotor cooling with air either naturally induced by rotor spin or forced airflow with the help of a blower, to circumvent challenges imposed by higher windage losses. The work highlights motor rotational speed limitations and the need for potential liquid cooling options for desired rotor performance at higher rotational speeds. Liquid cooling for the rotor may even become more critical for nonuniform rotor-stator gaps, leading to even higher and uneven windage losses across the full circumference of the motor, consequentially, more heating for the rotor.

30 DIRECT ENERGY CONVERSION↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Nonparametric Approach for Probabilistic Load-Margin Assessment Considering Wind Power Penetration

A modern power system is characterized by an increasing penetration of wind power, which results in large uncertainties in its states. These uncertainties must be quantified properly; otherwise, the system security may be threatened. Facing this challenge, here we propose a cost-effective, data-driven approach to assessing a power system's load margin probabilistically. Using actual wind data, a kernel density estimator is applied to infer the nonparametric wind speed distributions, which are further merged into the framework of a vine copula. The latter enables us to simulate complex multivariate and highly dependent model inputs with a variety of bivariate copulae that precisely represent the tail dependence in the correlated samples. Furthermore, to reduce the prohibitive computational time of traditional Monte-Carlo simulations that process a large amount of samples, we propose to use a nonparametric, Gaussian-process-emulator-based reduced-order model to replace the original complicated continuation power-flow model through a Bayesian-learning framework. To accelerate the convergence rate of this Bayesian algorithm, a truncated polynomial chaos surrogate, which serves as a highly efficient, parametric Bayesian prior, is developed. This emulator allows us to execute the time-consuming continuation power-flow solver at the sampled values with a negligible computational cost. Results of simulations that are performed on several test systems reveal the impressive performance of the proposed method in the probabilistic load-margin assessment.

17 WIND ENERGY↗

Full-Field Strain Measurement Integrated with Two Dimension Regression Analysis to Evaluate the Bi-Modulus Elastic Properties of Isotropic and Transversely Isotropic Materials

Background: Measuring the physical properties of shale is critical for optimizing engineering activities such as geothermal energy generation and hydraulic fracturing. Shale is a transversely isotropic material. Furthermore, this material can also include micro and macro cracks at different locations and orientations that cause it to behave differently under tensile or compressive loading. Objective: In this work, a combined experimental–numerical approach is proposed to evaluate the bi-modulus elastic properties of isotropic and transversely isotropic materials. Methods: Full-field strain measurements for a circular disk under diametral compression are integrated with a regression analysis technique to evaluate the elastic properties of bi-modulus materials subjected to tensile and compressive loads using two loading configurations on the same specimen. Digital Image Correlation (DIC) is used to measure the full-field strains. Subsequently, in the case of an isotropic material, a linear least-squares approach is utilized to process the experimentally determined strains in conjunction with analytical expressions of the stress fields (in terms of far-field loading) to determine the elastic modulus E, the shear modulus G, and the Poisson’s ratio $v$. In the case of a transversely isotopic material, such as shale, a finite element model is implemented to determine the stress fields (again in terms of far-field loading), which is followed by repeating the previous regression analysis in an iterative process to estimate the elastic parameters. Results: The results show that the proposed technique successfully provides a complete set of elastic properties as a function of both the loading condition and the principal material directions. The technique is validated by measurements on a known isotropic material and then applied to determine the properties of shale. Conclusion: In this work, the proposed approach is successfully used to calculate the bi-modulus elastic response of poly(methyl meth- acrylate) (PMMA) and shale. As expected, PMMA exhibits an isotropic response with no bi-modulus effect, however, shale exhibits both transverse isotropy and a bi-modulus effect. Therefore, this approach holds promise for investigating the elastic properties of materials like rocks and fiber-reinforced composite laminates as functions of the principal material directions and the loading conditions.

42 ENGINEERING↗

An Adaptive-Importance-Sampling-Enhanced Bayesian Approach for Topology Estimation in an Unbalanced Power Distribution System

The reliable operation of a power distribution system relies on a good prior knowledge of its topology and its system state. Although crucial, due to the lack of direct monitoring devices on the switch statuses, the topology information is often unavailable or outdated for the distribution system operators for real-time applications. Apart from the limited observability of the power distribution system, other challenges are the nonlinearity of the model, the complicated, unbalanced structure of the distribution system, and the scale of the system. To overcome the above challenges, we, in this paper, propose a Bayesian-inference framework that allows us to simultaneously estimate the topology and the state of a three-phase, unbalanced power distribution system. Specifically, by using the very limited number of measurements available that are associated with the forecast load data, we efficiently recover the full Bayesian posterior distributions of the system topology under both normal and outage operation conditions. This is performed through an adaptive importance sampling procedure that greatly alleviates the computational burden of the traditional Monte-Carlo (MC)-sampling-based approach while maintaining a good estimation accuracy. The simulations conducted on the IEEE 123-bus test system and an unbalanced 1282-bus system reveal the excellent performances of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additive manufacturing of metal matrix composites

Although Metal matrix composites (MMCs) are superior to most sought-after metallic alloys, their challenging fabricability has limited their widespread use in bulk-form applications. Among the many advanced fabrication techniques, Additive Manufacturing (AM), owing to its unique capabilities to produce near-net shapes, has drawn significant traction in the past two decades, especially for materials that are difficult to process using traditional methods. However, unlike pure metal/alloy systems, MMCs are highly sensitive to the processing conditions prevailing in AM techniques due to factors such as the high melting point of reinforcement particles and the potential for in-situ reactions. Therefore, it may be a while before metal matrix composites are commercially produced via AM. This review will discuss the current state-of-the-art design, fabricability, and performance of various additively manufactured MMCs. A particular focus will be on microstructural evolution and microstructure-property relationships. The most employed AM techniques, such as directed energy deposition, powder bed fusion, binder jetting, sheet lamination, and solid-state friction stir processing, are fundamentally different in terms of thermo-kinetics, forming the perspective for this review. A detailed comparison of microstructural evolution and process parameter optimization, including feedstock preparation methods and the role of machine learning and modeling among the different AM processes, is also presented. Finally, a critical evaluation of emerging AM technologies for MMCs is also provided, highlighting their potential advantages and challenges.

36 - MATERIALS SCIENCE↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Instrumented Photovoltaic Modules for Environmental Characterization and Simulation Model Validation

Photovoltaic modules are subjected to various mechanical stressors in their deployment environments, ranging from installation handling to wind and snow loads. Damage incurred during these mechanical events has the potential to initiate subsequent degradation mechanisms, reducing useful module lifespan. Thus, characterizing the mechanical state of photovoltaic modules is pertinent to the development of reliable packaging designs. In this work, photovoltaic modules with strain gauges directly incorporated into the module laminate were fabricated and subjected to mechanical loading to characterize internal strains within the module when under load. These experimental measurements were then compared against results obtained by high-fidelity finite-element simulations. The simulation results showed reasonable agreement in the strain values over time; however, there were large discrepancies in the magnitudes of these strains. Both the instrumentation technique and the finite-element simulations have areas where they can improve. These areas of improvement have been documented. Despite the observed discrepancies between the experimental and simulated results, the module instrumentation proved to be a useful gauge in monitoring and characterizing the mechanical state. With some process improvements, this method could potentially be applied to other environments that a photovoltaic module will encounter in its lifetime that are known to cause damage and degrade performance.

14 SOLAR ENERGY↗

Design and Validation of A 250-kW All-Silicon Carbide High-Density Three-Level T-Type Inverter

Our article introduces a comprehensive design and validation of a compact all-silicon carbide (SiC) 250-kW T-type traction inverter with a power density of 25 kW/l and 98.5% peak efficiency. All the operation modes and switching transitions in a T-type phase leg are analyzed to model the semiconductor power losses over a fundamental cycle. Special attention has been paid to explore the behavior and losses due to the reverse conduction of the SiC MOSFETs. Then a loss model is built based upon this analysis to calculate the device loss distribution and system efficiency, which is further used to determine the optimal switching frequency. In addition, detailed inverter system design and prototyping procedure, including the selection of SiC modules and dc-link capacitors, and the optimization of a fourlayer laminated busbar, are presented. In this article, the T-type phase leg is formed by a normal half-bridge module and a common-source module. The switching performance and losses in this configuration are different from two-level topology that only uses one SiC module. Thus, the switching performance and the associated switching energy in each switch position are characterized using a custom clamped inductive load (CIL) test setup designed for a T-type phase leg. The performance of the full power traction inverter prototype has been verified experimentally using pulse testing and continuous power testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

Vertical z-axis discontinuous carbon fibers for improved lightning strike performance of continuous fiber-reinforced polymer composites

Effective lightning strike protection for critical aerospace and wind applications requires high electrical conductivity to dissipate current efficiently. However, polymer matrix composites face a challenge due to their inherently insulating nature. While conventional carbon fiber-reinforced composites (CFRP) exhibit electrical conductivity in the planar direction, achieving through-thickness conductivity remains an ongoing challenge. In this work, we have undertaken the fabrication of CFRP interleaved with vertically oriented carbon fibers (Z-fiber) to impart higher electrical conductivity along the thickness direction. Two Z-fiber composite variations are prepared: Z-1 with a single layer of Z-fiber and Z-5 with five interleaved layers and compared with no Z-fiber layer (Z-0) composite. The composite panels were subjected to lab-scale lightning strike tests with a current magnitude of 100 kA. To emulate real-world service conditions, an aerospace-grade paint coating was applied to the composite laminates. Comparative analysis shows Z-1 reduces damage diameter to ∼22 mm compared to Z-0 (∼26 mm), while Z-5 exhibits the least damage (∼16.7 mm), confirmed by optical microscopy. Z-5 demonstrates nine times higher through-thickness electrical conductivity than Z-0, reducing electrical anisotropy substantially. Thermal-electric finite element damage modeling predicts surface damage within 6% of experimental values for both Z-0 and Z-5 composites. Flexural tests post-lightning reveal Z-5 retains 66% flexural strength and 86% modulus, significantly better than Z-0, which retains less than 40% for both properties. This study highlights the efficacy of Z-fiber composites in lightning strike protection, offering improved through-thickness conductivity and mechanical property retention.

36 MATERIALS SCIENCE↗

A FFT-based mesoscale continuum dislocation mechanics with defect energy: Applications to composites and polycrystals

A crystal plasticity elastoviscoplastic FFT (fast Fourier transform) formulation with a mesoscale continuum field dislocation mechanics model is presented, which incorporates a defect energy density that depends on GND densities and an associated material length scale. This allows to thermodynamically derive internal length scale dependent intra-crystalline backstress and Peach–Koehler force acting on GND densities. The model considers GND density evolution through a filtered numerical spectral approach, which is coupled with stress equilibrium through the elastoviscoplastic FFT algorithm. The discrete Fourier transform (DFT) method together with finite difference (FD) schemes is applied to solve both the backstress tensor and the Fourier–Green operator. Numerical results are first reported for two-phase laminate composites with plastic single crystal channels and elastic precipitates for shear loadings. Channel size effects are simulated and analyzed on the overall and local hardening behaviors during monotonous loadings. In addition, the evolutions of GND densities and the role of their associated backstress on size effects are examined during reversible shear loading. In a second part, the role of the defect energy internal length scale on polycrystal’s hardening during tension–compression is discussed. The results are compared to those obtained using FFT-based continuum field dislocation mechanics without defect energy.

36 MATERIALS SCIENCE↗

Quantifying Optical Loss of High-Voltage Degradation Modes in PV Modules Using Spectral Analysis [Slides]

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative ("HV-") and positive ("HV+") polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including: corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (SixNy) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85 degrees C/85% relative humidity included: spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the SixNy coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared to a mini-module previously subjected to HV-/HV+ stress. The model suggests one-third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the SixNy coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Probabilistic Power Flow Based on a Gaussian Process Emulator

In this letter, a novel Gaussian process emulator is proposed, for the first time, to conduct the probabilistic power-flow calculation. Based on Bayesian inference, a Gaussian process emulator is trained and served as a nonparametric, reduced-order model of the nonlinear power-flow model. This emulator has allowed us to evaluate the time-consuming power-flow solver at the sampled values with a negligible computational cost. The simulations reveal the excellent performance of this method.

42 ENGINEERING↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗