Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Model studies of laser absorption computed tomography for remote air pollution measurement

Model studies of the potential of laser absorption-computed tomography are presented which demonstrate the possibility of sensitive remote atmospheric pollutant measurements, over kilometer-sized areas, with two-dimensional resolution, at modest laser source powers. An analysis of this tomographic reconstruction process as a function of measurement SNR, laser power, range, and system geometry, shows that the system is able to yield two-dimensional maps of pollutant concentrations at ranges and resolutions superior to those attainable with existing, direct-detection laser radars.

Wolfe, D. C., Jr.↗

ATLAS: Airborne Tunable Laser Absorption Spectrometer for stratospheric trace gas measurements

The ATLAS instrument is an advanced technology diode laser based absorption spectrometer designed specifically for stratospheric tracer studies. This technique was used in the acquisition of N2O tracer data sets on the Airborne Antarctic Ozone Experiment and the Airborne Arctic Stratospheric Expedition. These data sets have proved valuable for comparison with atmospheric models, as well as in assisting in the interpretation of the entire ensemble of chemical and meteorological data acquired on these two field studies. The N2O dynamical tracer data set analysis revealed several ramifications concerning the polar atmosphere: the N2O/NO(y) correlation, which is used as a tool to study denitrification in the polar vertex; the N2O Southern Hemisphere morphology, showing subsidence in the winter polar vortex; and the value of the N2O measurements in the interpretation of ClO, O3, and NO(y) measurements and of the derived dynamical tracer, potential vorticity. Field studies also led to improved characterization of the instrument and to improved accuracy.

Loewenstein, Max↗

Amplified laser absorption - Detection of nitric oxide.

Experimental results are reported for the power loss of a carbon monoxide gas laser due to the absorption of small amounts of nitric oxide placed in an intra-laser-cavity absorption cell. It was found, for the particular experimental conditions employed, that the absorption coefficient of nitric oxide at 1900.04/cm is enhanced more than two orders of magnitude when it is in the intracavity cell. Finally, the experimental results are compared with theoretical calculations.

Chackerian, C., Jr.↗

Differential laser absorption monitoring of the atmosphere

In the airborne detection system of atmospheric constituents and pollutants described, double-ended differential absorption measurement is accomplished by rapidly current tuning the wavelength of a PbSSe diode laser across a single line of the species under consideration. As the laser wavelength sweeps periodically across the absorption line, the laser beam is amplitude modulated and is then synchronously detected. With this technique, a minimum detectable differential transmission of 0.02 percent is obtained for a 1-sec integration time.

Rubin, B.↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Brewster-plate spoiler - A novel method for reducing the amplitude of interference fringes that limit tunable-laser absorption sensitivities

A simple method is described for substantially reducing the amplitude of interference fringes that limit the sensitivities of tunable-laser high-resolution absorption spectrometers. A lead-salt diode laser operating in the 7-micron region is used with a single Brewster-plate spoiler to reduce the fringe amplitude by a factor of 30 and also to allow the detection of absorptances 0.001 percent in a single laser scan without subtraction techniques, without complex frequency modulation, and without distortion of the molecular line-shape signals. Application to multipass-cell spectrometers is described.

Webster, C. R.↗

Probing the SEB Sensitive Depth of a Power MOSFET Using a Two-Photon Absorption Laser Method

This paper presents two-photon absorption test results on an engineering single-event burnout- (SEB-) sensitive power MOSFET to verify that the energy deposition/charge ionization in the highly-doped substrate does not contribute to SEB. It is shown that for a vertical power MOSFET, the SEB sensitive volume is the lightly doped epitaxial layer; the most sensitive region is under the polysllicon gate.

Lauenstein, Jean-Marie↗

Enhanced collisionless laser absorption in strongly magnetized plasmas

We report that strongly magnetizing a plasma adds a range of waves that do not exist in unmagnetized plasmas and enlarges the laser-plasma interaction (LPI) landscape. In this paper, we use particle-in-cell simulations to investigate strongly magnetized LPI in one dimension under conditions relevant for magneto-inertial fusion experiments, focusing on a regime where the electron-cyclotron frequency is greater than the plasma frequency and the magnetic field is at an oblique angle with respect to the wave vectors. We show that when electron-cyclotron-like hybrid wave frequency is about half the laser frequency, the laser light resonantly decays to magnetized plasma waves via primary and secondary instabilities with large growth rates. These distinct magnetic-field-controlled instabilities, which we collectively call two-magnon decays, are analogous to two-plasmon decays in unmagnetized plasmas. Since additional phase mixing mechanisms are introduced by the oblique magnetic field, collisionless damping of large-amplitude magnetized waves substantially broadens the electron distribution function, especially along the direction of the magnetic field. During this process, energy is transferred efficiently from the laser to plasma waves and then to electrons, leading to a large overall absorptivity when strong resonances are present. The enhanced laser energy absorption may explain hotter-than-expected temperatures observed in magnetized laser implosion experiments and may also be exploited to develop more efficient laser-driven x-ray sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Balloon-borne diode-laser absorption spectrometer for measurements of stratospheric trace species

An instrument has been designed for the measurement of stratospheric trace species which utilizes tunable infrared diode lasers as sources for sensitive in situ absorption spectroscopy in selected wavelength regions. This instrument, the Balloon-Borne Laser In Situ Sensor (BLISS), is a high-resolution absorption spectrometer designed to provide measurements of the concentrations of stratospheric species and their diurnal variations. The instrument employs second-harmonic detection of the absorption of tunable diode laser (TDL) radiation (3-30 microns) in a 1 km path length defined by a retroreflector lowered 0.5 km below the BLISS gondola. Retroreflector tracking under microprocessor control is obtained using a He-Ne laser and coaligned TV camera with CID imaging. Simultaneous measurements of molecular species in the 20-40 km altitude range will be performed using four TDLs, with the predicted minimum-detectable mixing ratio at 30 km being typically less than or equal to 0.1 ppbv.

Menzies, R. T.↗

Continuum laser absorption spectroscopy of C 2 (a 3 Π u ) in a sublimating cloud of carbon black

A direct optical absorption diagnostic has been developed for rotationally resolved measurements of diatomic carbon (a 3 Π u →d 3 Π g (0,0) and (1,1)) at a repetition rate of 525 kHz and resolution of 7.3 pm over the range of 511.1–514.1 nm. The diagnostic utilizes a high-power pulsed continuum laser light source dispersed in a spectrograph and imaged by a high-speed camera. Measurements have been performed that capture the temporal evolution of C 2 number density and temperature of a cloud of carbon black sublimating in shock heated gas at high temperature and pressure (T = 5500 K, P = 3.7 atm). A simultaneous light absorption measurement of the condensed phase enables comparisons of the gaseous C 2 number density to the condensed phase mass. The continuum laser absorption diagnostic is applied to C 2 in this work but shows promise in being a simple “drop-in” system for absorption spectroscopy in the visible range at rapid repetition rates and high dispersion, filling an important gap for laser diagnostic systems.

Willhardt, Colton Dean [Univ. of Illinois at Urban↗

Single-tone and two-tone AM-FM spectral calculations for tunable diode laser absorption spectroscopy

A generalized theory for optical heterodyne spectroscopy with phase modulated laser radiation is used which allows the calculation of signal line shapes for frequency modulation spectroscopy of Lorentzian gas absorption lines. In particular, synthetic spectral line shapes for both single-tone and two-tone modulation of lead-salt diode lasers are presented in which the contributions from both amplitude and frequency modulations are included.

Chou, Nee-Yin↗

Laser absorption spectroscopy - Method for monitoring complex trace gas mixtures

A frequency stabilized CO2 laser was used for accurate determinations of the absorption coefficients of various gases in the wavelength region from 9 to 11 microns. The gases investigated were representative of the types of contaminants expected to build up in recycled atmospheres. These absorption coefficients were then used in determining the presence and amount of the gases in prepared mixtures. The effect of interferences on the minimum detectable concentration of the gases was measured. The accuracies of various methods of solution were also evaluated.

Green, B. D.↗

Tunable diode laser absorption sensor for temperature and velocity measurements of O2 in air flows

A fast and nonintrusive velocity and temperature diagnostic based on oxygen absorption is presented. The system uses a GaAlAs tunable diode laser, ramped and modulated in wavelength at high frequency. Detection is performed at twice the modulating frequency, leading to second harmonic absorption lineshapes. Velocity is inferred from the wavelength shift of the absorption line center due to the Doppler effect. Temperature is determined by comparing experimental and calculated lineshapes. Capabilities of the technique for studies of transient high-speed flows are demonstrated in shock tube experiments. Good agreement is obtained with predicted temperatures and velocities when pressure-induced shifts are accounted for.

Philippe, L. C.↗

High-resolution laser absorption spectroscopy of ozone near 1129.4 cm (-1)

A Beer's Law experiment was performed with a tunable diode laser to determine self broadened line shape parameters of one infrared absorption ozone line in the nu1 band for ten pressures from 0.26 to 6.29 torr at 285 K. The SO2 line positions were used for wavelength calibration. Line shapes were iteratively fitted to the Voigt function at a Doppler width of 29.54 MHz (HWHM) resulting in values for the integrated line strength, (S), of (0.144 +/- 0.007) x 10 to the minus 20th/cm molecule/cu cm, line center frequency, nu sub o, of 1129.426/cm and the Lorentzian contributions to halfwidth. A linear least squares fit of (alpha sub L)5 as a function of pressure yielded a zero intercept of 15.27 +/- 0.29 MHz (rho = 0.99) and a broadening parameter, (alpha sub L)5, of 5.71 +/- 0.29 MHz/Torr. This results in a line width (FWHM) of 0.144 +/- .007/cm at 760 torr and 285 K.

Majorana, L. N.↗

Stratospheric species measurements with tunable diode laser absorption spectroscopy

A balloon-borne instrument for stratospheric research has been developed with the capability to simultaneously measure several chemically related species in situ, for a full diurnal cycle. The instrument utilizes tunable infrared diode lasers (TDLs) to provide the radiation in selected wavelength regions for sensitive absorption spectroscopy over a one-km round-trip path. The TDL radiation is directed to a remote retroreflector which is lowered 500 m below the instrument gondola. A HeNe laser and co-aligned TV camera with CID imaging are used for retroreflector tracking. Currently the instrument operates with two TDLs, and the capability exists to measure four stratospheric species: NO, NO2, O3, and H2O. The number of operating TDLs can be expanded to four, resulting in the possibility of measuring several additional trace species.

Menzies, R. T.↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields: Abstract

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗