Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microwave SQUID Multiplexing for the Lynx X-Ray Microcalorimeter

The Lynx x-ray microcalorimeter (LXM) is an imaging spectrometer for the Lynx satellite mission, an x-ray telescope being considered by NASA to be a new flagship mission. Lynx will enable unique astrophysical observations into the x-ray universe due to its high angular resolution and large field of view. The LXM consists of an array of over 100,000 pixels and poses a significant technological challenge to achieve the high degree of multiplexing required to read out these sensors. We discuss the details of microwave superconducting quantum interference device (SQUID) multiplexing and describe why it is ideally suited to the needs of the LXM. This case is made by summarizing the current and predicted performance of microwave SQUID multiplexing and describing the steps needed to optimize designs for all the LXM arrays. Finally, we describe our plan to advance the technology readiness level (TRL) of microwave SQUID multiplexing of the LXM microcalorimeters to TRL-5 by 2024.

Bennett, Douglas A.↗

Application of Frequency Division Multiplexing and Neural Networks in the Operation and Diagnosis of the Stator Current and Shaft Position Sensors Used in Electric/Hybrid Vehicles

Fast, precise and robust sensing of currents and motor shaft angle is essential for the excellent performance of electric and hybrid vehicles (EV/HEV). Multiplexing techniques are commonly applied in data acquisition systems (DAQs) to digitize the signals sensed in EV/HEV drives. Frequency-division multiplexing (FDM) applied to get the signals from current sensors and resolver angular position sensor has advantages over conventional multiplexing approaches. However, problems such as aging and mechanical imperfections distort the outputs of those sensors, producing measurement errors of the angular position and currents. Conventional techniques designed to compensate for those errors cannot be applied in signals multiplexed in frequency. This paper proposes online techniques to detect and compensate for the distortions in the resolver sensor and current sensors. The demultiplexing process was adjusted to allow distortion detection and compensation. An auto-associative neural network (ANN) compensates for the current measurement error, while an energy-based technique is applied to compensate for the distortions in the resolver outputs. The obtained results show that the distortions were compensated, allowing a more accurate estimation of stator currents and angular position when FDM is applied in EV/HEV DAQs.

Pereira Pinto, Joao↗

Optimization of multiplexed CRISPR/Cas9 system for highly efficient genome editing in Setaria viridis

Previously, Setaria viridis has been developed as a model plant to better understand the C4 photosynthetic pathway in major crops. With the increasing availability of genomic resources for S. viridis research, highly efficient genome editing technologies are needed to create genetic variation resources for functional genomics. In this paper, we developed a protoplast assay to rapidly optimize the multiplexed CRISPR/Cas9 system in S. viridis. Targeted mutagenesis efficiency was further improved by an average of 1.4-fold with the exonuclease, Trex2. Distinctive mutation profiles were found in the Cas9_Trex2 samples with 94% of deletions larger than 10bp, and less than 1% of mutations being insertions. Further analyses indicated that 52.2% of deletions induced by Cas9_Trex2, as opposed to 3.5% by Cas9 alone, were repaired through microhomology-mediated end joining (MMEJ) rather than the canonical NHEJ DNA repair pathway. Combined with the robust agrobacterium-mediated transformation method with more than 90% efficiency, the multiplex CRISPR/Cas9_Trex2 system was demonstrated to induce targeted mutations in two tightly linked genes, svDrm1a and svDrm1b, at the frequency ranging from 73% to 100% in T0 plants. These mutations were transmitted to at least 60% of the transgene-free T1 plants with 33% of them containing bi-allelic or homozygous mutations in both genes. This highly efficient multiplex CRISPR/Cas9_Trex2 system makes it possible to create a large mutant resource for S. viridis in a rapid and high throughput manner, and has the potential to be widely applicable in achieving more predictable MMEJ-mediated mutations in many plant species.

59 BASIC BIOLOGICAL SCIENCES↗

Chapter 2: Trackable Multiplex Recombineering (TRMR) and Next-Generation Genome Design Technologies: Modifying Gene Expression in E. coli by Inserting Synthetic DNA Cassettes and Molecular Barcodes

This chapter describes the trackable multiplex recombineering (TRMR) and tunable trackable multiplex recombineering (T2RMR) techniques, which not only make the multiplexing of recombineering possible in Escherichia coli but also provide the ability to track the engineered genetic changes accurately. TRMR and T2RMR have only been used for modifying the expression level of genes. Screening and selection of TRMR and T2RMR clones can be carried out using either liquid or solid media with any chemical compound that modifies growth or confers a phenotype that can be detected by a high-throughput assay. In order to engineer a genome using TRMR or T2RMR, a synthetic DNA (synDNA) cassette is created that encodes for a genetic feature and a molecular barcode that is used to track each feature. These synDNA cassettes are then introduced in parallel into cell populations via recombineering.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic Design and Experimental Demonstration of Transmission-Type Multiplexed Acoustic Metaholograms

Acoustic holograms have promising applications in sound-field reconstruction, particle manipulation, ultrasonic haptics, and therapy. This study reports on the theoretical, numerical, and experimental investigation of multiplexed acoustic holograms at both audio and ultrasonic frequencies via a rationally designed transmission-type acoustic metamaterial. The proposed metahologram is composed of two Fabry–Pérot resonant channels per unit cell, which enables the simultaneous modulation of the transmitted amplitude and phase at two desired frequencies. In contrast to conventional acoustic metamaterial-based holograms, the design strategy proposed here provides a new degree of freedom (frequency) that can actively tailor holograms that are otherwise completely passive and significantly enhances the information encoded in acoustic metamaterials. To demonstrate the multiplexed acoustic metamaterial, the projection of two different high-quality metaholograms is first shown at 14 and 17 kHz, with the patterns of the letters N and S. Then, two-channel ultrasound focusing and annular beams generation for the incident ultrasonic frequencies of 35 and 42.5 kHz are demonstrated. Furthermore, these multiplexed acoustic metaholograms offer a technical advance to tackle the rising challenges in the fields of acoustic metamaterials, architectural acoustics, and medical ultrasound.

36 MATERIALS SCIENCE↗

Microwave Multiplexing on the Keck Array

In this paper, we describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018–2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5–6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a low-parasitic frequency-domain multiplexing readout

Frequency-domain multiplexing is a readout technique for transition-edge sensor bolometer arrays used on modern cosmic microwave background experiments, including the SPT-3G receiver. Here, we present design details and performance measurements for a low-parasitic frequency-domain multiplexing readout. Reducing the parasitic impedance of the connections between cryogenic components provides a path to improve both the crosstalk and noise performance of the readout. Reduced crosstalk will in turn allow higher-multiplexing factors. We have demonstrated a factor of two improvement in parasitic resistance compared to SPT-3G hardware. Reduced parasitics also permits operation of lower-resistance bolometers optimized for improved readout noise performance. We demonstrate that a module in the prototype system has comparable readout noise performance to an SPT-3G module when operated with dark TES bolometers in the laboratory.

frequency-domain multiplexing↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Application of deconvolution to recover frequency-domain multiplexed detector pulses

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique “tags” by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. In conclusion, a figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic on-chip multiplexer for the study of quantum transport in 256 split-gate devices

We present a multiplexing scheme for the measurement of large numbers of mesoscopic devices in cryogenic systems. The multiplexer is used to contact an array of 256 split gates on a GaAs/AlGaAs heterostructure, in which each split gate can be measured individually. The low-temperature conductance of split-gate devices is governed by quantum mechanics, leading to the appearance of conductance plateaux at intervals of 2e{sup 2}/h. A fabrication-limited yield of 94% is achieved for the array, and a “quantum yield” is also defined, to account for disorder affecting the quantum behaviour of the devices. The quantum yield rose from 55% to 86% after illuminating the sample, explained by the corresponding increase in carrier density and mobility of the two-dimensional electron gas. The multiplexer is a scalable architecture, and can be extended to other forms of mesoscopic devices. It overcomes previous limits on the number of devices that can be fabricated on a single chip due to the number of electrical contacts available, without the need to alter existing experimental set ups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zero-added-loss entanglement multiplexing using time-bin spectral shearing

High-quality quantum communications that enable important capabilities, such as distributed quantum computing and sensing, will require quantum repeaters for providing high-quality entanglement. To realize high-rate heralded entanglement for quantum repeaters, Chen et al . [Phys. Rev. Appl. 19 , 054029 (2023)] proposed a scheme for heralded-multiplexed generation of quasideterministic entangled photon pairs, called zero-added-loss multiplexing (ZALM). Here, we propose a design of the ZALM source using time-bin entanglement and spectral shearing. Additionally, we provide an analysis of experimentally relevant spectral-shearing parameters to optimize the spectral multiplexing. Moreover, we experimentally verify the compatibility of time-bin pulses and spectral shearing, as supported by observation of no appreciable phase shift when the same shearing is applied to both time bins. These results expand the benefits of applying a ZALM source to time-bin entanglement use cases. Moreover, more fully demonstrating time-bin and spectral shearing compatibility clears a path toward a broader use of spectral shearing that provides a deterministic frequency shift of high utility.

entanglement production↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Multiplexing of frequency-modulation spectroscopy by spread-spectrum codes, demonstrated in continuous-wave LIDAR

Frequency-modulation spectroscopy (FMS) is generally suited to code-division multiplexing, and we demonstrate that capacity in a form of continuous-wave LIDAR, utilizing a sharp CO 2 absorption transition at 1.6 µm in simple ranging setups. The approach retains the advantages of FMS, including coherent detection and good rejection of broad absorption backgrounds. Extensions of this multiplexed approach to the continuous, simultaneous detection of several transitions would come by transmitting an encoded combination of frequency-modulated carriers, each tuned to detect a unique absorption transition. Signal analysis at the receiver involves a simple process of de-multiplexing that, in a general application, reveals targets at various distances and the absorption-related FMS signals in between.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multiplexed Fluorescent Calcium and NFAT Reporter Gene Assay to Identify GPCR Agonists

Intracellular calcium response and resulting calcium signaling to an agonist-GPCR interaction are important for the measurement of compound activity in the GPCR drug development. The increase in cytosol calcium concentration can be measured by the fluorescent calcium indicator dye such as Fluo-4 in a quick assay (in 3-5 minutes) using the fluorescence imaging plate reader. The calcium signaling through the transcription factors such as NFAT that induces gene expression can be measured by the reporter gene assay that links to the expression of reporter enzyme such as the betalactamase that requires 5-hour incubation. We have evaluated a multiplexed assay that sequentially measures the calcium response to a GPCR agonist in a rapid fluorescent calcium dye assay, followed by a NFAT beta-lactamase assay, and compared them in the single assay format. We found that the agonist activity determined in the multiplexed assay were comparable with these determined in the single assay format and the Z’ factors were all >0.5. Five active compounds were identified that were active in both calcium dye assay and beta-lactamase assay. Therefore, our results demonstrated the utility of this multiplexed calcium assay for screening of GPCR compounds that can cross validate the primary hits and help to eliminate the false positive compounds.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexed photoinjector optimization for high-repetition-rate free-electron lasers

The multiplexing capabilities of superconducting X-ray free-electron lasers (FELs) have gained much attention in recent years. The demanding requirements for photon properties from multiple undulator lines necessitate more flexible beam manipulation techniques to achieve the goal of “beam on demand”. In this paper, we investigate a multiplexed configuration for the photoinjector of high-repetition-rate FELs that aims to simultaneously provide low-emittance electron beams of different charges. A parallel, multi-objective genetic algorithm is implemented for the photoinjector parameter optimization. The proposed configuration could drastically enhance the flexibility of beam manipulation to improve multiplexing capabilities and realize the full potential of the facility.

47 OTHER INSTRUMENTATION↗

Multiplexed Readout for an Experiment with a Large Number of Channels Using Single-Electron Sensitivity Skipper-CCDs

This paper presents the implementation of a multiplexed analog readout electronics system that can achieve single-electron counting using Skipper-CCDs with non-destructive readout. The proposed system allows the best performance of the sensors to be maintained, with sub-electron noise-level operation, while maintaining low-bandwidth data transfer, a minimum number of analog-to-digital converters (ADC) and low disk storage requirement with zero added multiplexing time, even for the simultaneous operation of thousands of channels. These features are possible with a combination of analog charge pile-up, sample and hold circuits and analog multiplexing. The implementation also aims to use the minimum number of components in circuits to keep compatibility with high-channel-density experiments using Skipper-CCDs for low-threshold particle detection applications. Performance details and experimental results using a sensor with 16 output stages are presented along with a review of the circuit design considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗