Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Oak Ridge National Laboratory 2025 Site Sustainability Plan With FY 2024 Performance Data

At the close of each fiscal year, the US Department of Energy (DOE) Sustainability Performance Office (SPO) issues instruction documents and technical resource aids/tools necessary for DOE sites and national laboratories to complete sustainability reporting requirements. SPO is part of the DOE Office of Asset Management. As required by DOE Order 436.1A, Departmental Sustainability, each site develops and commits to an annual site sustainability plan (SSP) that identifies its respective contribution toward meeting DOE’s sustainability goals. SPO collects and compiles information reported by each site to develop an agency-wide sustainability report and implementation plan, which are used to report DOE sustainability progress to the federal government as required by all major federal agencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

DAISY Benchmark Performance Data

This repository contains the underlying data from benchmark experiments for Drifting Acoustic Instrumentation SYstems (DAISYs) in waves and currents described in "Performance of a Drifting Acoustic Instrumentation SYstem (DAISY) for Characterizing Radiated Noise from Marine Energy Converters" (https://link.springer.com/article/10.1007/s40722-024-00358-6). DAISYs consist of a surface expression connected to a hydrophone recording package by a tether. Both elements are instrumented to provide metadata (e.g., position, orientation, and depth). Information about how to build DAISYs is available at https://www.pmec.us/research-projects/daisy. The repository's primary content is three compressed archives (.zip format), each containing multiple MATLAB binary data files (.mat format). A table relating individual data files to figures in the paper, as well as the structure of each file, is included in the repository as a Word document (Data Description MHK-DR.docx). Most of the files contain time series information for a single DAISY deployment (file naming convention: [site]_DAISY_[Drift #].mat) consisting of processed hydrophone data and associated metadata. For a limited number of DAISY deployments, the hydrophone package was replaced with an acoustic Doppler velocimeter (file naming convention: [site]_DAISY_[Drift #]_ADV.mat). Data were collected over several years at three locations: (1) Sequim Bay at Pacific Northwest National Laboratory's Marine & Coastal Research Laboratory (MCRL) in Sequim, WA, the energetic tidal channel in Admiralty Inlet, WA (Admiralty Inlet), and the U.S. Navy's Wave Energy Test Site (WETS) in Kaneohe, HI. Brief descriptions of data files at each location follow. - MCRL - (1) Drift #4 and #16 contrast the performance of a DAISY and a reference hydrophone (icListen HF Reson), respectively, in the quiescent interior of Sequim Bay (September 2020). (2) Drift #152 and #153 are velocity measurements for a drifting acoustic Doppler velocimeter in in the tidally-energetic entrance channel inside a flow shield and exposed to the flow, respectively (January 2018). (3) Two non-standard files are also included: DAISY_data.mat corresponds to a subset of a DAISY drift over an Adaptable Monitoring Package (AMP) and AMP_data.mat corresponds to approximately co-temporal data for a stationary hydrophone on the AMP (February 2019). - Admiralty Inlet - (1) Drift #1-12 correspond to tests with flow shielded DAISYs, unshielded DAISYs, a reference hydrophone, and drifting acoustic Doppler velocimeter with 5, 10, and 15 m tether lengths between surface expression and hydrophone recording package (July 2022). (2) Drift #13-20 correspond to tests of flow shielded DAISYs with three different tether materials (rubber cord, nylon line, and faired nylon line) in lengths of 5, 10, and 15 m (July 2022). - WETS - (1) Drift #30-32 correspond to tests with a heave plate incorporated into the tether (standard configuration for wave sites), rubber cord only, and rubber cord, but with a flow shielded hydrophone (November 2022). (2) Drift #49-58 and Drift #65-68 correspond to measurements around mooring infrastructure at the 60 m berth where time-delay-of-arrival localization was demonstrated for different DAISY arrangements and hydrophone depths (November 2022).

16 TIDAL AND WAVE POWER↗

Statistical Framework for Planning a Shelf Life Program with Binary Performance Data

This document outlines a statistical framework for establishing a shelf-life program for components whose performance is measured by a binary response, usually ‘pass’ or ‘fail.’ The approach applies to both single measurement devices and repeated measurement devices. The high-level objective of these plans is to quickly detect any sizeable increase in fraction defective as the product ages. The statistical approach is to choose a sample size and monitoring technique that alarms when the fraction defective increases to an unacceptably high level, but does not alarm when the process is at nominal. The nominal (acceptable) fraction defective is used, and an increased fraction defective (unacceptable) is assumed as part of the control chart design. The control chart recommended for this problem is the Bernoulli Cumulative Sum (CUSUM) control chart.

97 MATHEMATICS AND COMPUTING↗

Nuclear Data Performance Testing Using Sensitive, but Less Frequently Used ICSBEP Benchmarks

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has published the International Handbook of Evaluated Criticality Safety Benchmark Experiments annually since 1995. The Handbook now spans over 51,000 pages with benchmark specifications for 4,283 critical, near critical, or subcritical configurations; 24 criticality alarm placement/shielding configurations with multiple dose points for each; and 200 configurations that have been categorized as fundamental physics measurements relevant to criticality safety applications. Benchmark data in the ICSBEP Handbook were originally intended for validation of criticality safety methods and data; however, the benchmark specifications are now used extensively for nuclear data testing. There are several, less frequently used benchmarks within the Handbook that are very sensitive to thorium and certain key structural and moderating materials. Calculated results for many of those benchmarks using modern nuclear data libraries suggest there is still room for improvement. These and other highly sensitive, but rarely quoted benchmarks are highlighted and data testing results provided using the Monte Carlo N-Particle Version 5 (MCNP5) code and continuous energy ENDF/B-V, VI.8, and VII.0, JEFF-3.1, and JENDL-3.3 nuclear data libraries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Refining seasonal performance metrics for room air-conditioning in emerging markets: Integrating building simulations with real-world equipment performance data

Buildings significantly impact worldwide energy consumption, emphasizing the need to reduce the cooling energy demand, especially in warm climates. Minimum energy performance standards (MEPS) and seasonal performance metrics such as the Cooling Seasonal Performance Factor (CSPF) are crucial for improving room air conditioning (RAC) efficiency. However, challenges remain, particularly in emerging markets like Brazil, where seasonal performance metrics have recently been introduced. This study assesses the factors influencing country-level seasonal efficiency metrics and proposes a framework to refine these calculations by considering local climates and expected RAC usage in real-world households via building simulations. Key considerations include outdoor air temperature binning for different climates, RAC usage patterns (i.e., daytime and nighttime usages), envelope thermal performance of households, and urban heat island (UHI) effects. The results reveal that CSPF values can vary significantly based on climate conditions, with observed CSPF ranging from 4.10 to 11.59 Wh/Wh across 577 Brazilian climates. The inclusion of UHI effects led to a reduction in CSPF values by up to 29% during nighttime operations in hot urban areas. Additionally, building envelope efficiency showed contrasting impacts on RAC performance, with CSPFs reaching up to 15.35 Wh/Wh under specific optimized conditions. These findings highlight the need for transparent policymaking in RAC performance databases, facilitating the application of approaches like those proposed in this study and supporting diverse stakeholders in decision-making.

Bavaresco, Mateus↗

How Useful are Conventional I–Vs for Performance Calibration of Single- and Two-Junction Perovskite Solar Cells? A Statistical Analysis of Performance Data on ≈200 Cells from 30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well-documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. Here, the implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.

14 SOLAR ENERGY↗

Cryptonite: A Secure and Performant Data Repository on Public Clouds

Cloud storage has become immensely popular for maintaining synchronized copies of files and for sharing documents with collaborators. However, there is heightened concern about the security and privacy of Cloud-hosted data due to the shared infrastructure model and an implicit trust in the service providers. Emerging needs of secure data storage and sharing for domains like Smart Power Grids, which deal with sensitive consumer data, require the persistence and availability of Cloud storage but with client-controlled security and encryption, low key management overhead, and minimal performance costs. Cryptonite is a secure Cloud storage repository that addresses these requirements using a StrongBox model for shared key management.We describe the Cryptonite service and desktop client, discuss performance optimizations, and provide an empirical analysis of the improvements. Our experiments shows that Cryptonite clients achieve a 40% improvement in file upload bandwidth over plaintext storage using the Azure Storage Client API despite the added security benefits, while our file download performance is 5 times faster than the baseline for files greater than 100MB.

Cloud data storage↗

Summary Report of Cable Aging and Performance Data for Fiscal Year 2014

As part of the Light Water Reactor Sustainability Program, science - based engineering approaches were employed to address cable degradation behavior under a range of exposure environments. Experiments were conducted with the goal to provide best guidance for aged material states, remaining life and expected performance under specific conditions for a range of cable materials. Generic engineering tests, which focus on rapid accelerated aging and tensile elongation, were combined with complementary methods from polymer degradation science. Sandia's approach, building on previous years' efforts, enabled the generation of some of the necessary data supporting the development of improved lifetime predictions models, which incorporate known material behaviors and feedback from field - returned 'aged' cable materials. Oxidation rate measurements have provided access to material behavior under low dose rate thermal conditions, where slow degradation is not apparent in mechanical property changes. Such data have shown aging kinetics consistent with established radiation - thermal degradation models.

Celina, Mathias C.↗

Site Sustainability Plan (SSP) with FY2012 Performance Data

Oak Ridge National Laboratory (ORNL) is both the largest science and energy laboratory of the Department of Energy (DOE) and one of the oldest national laboratories still operating at its original site. These characteristics provide a unique opportunity to integrate sustainability into our facilities and activities. As a leading performer of clean energy research and development (R&D), ORNL delivers advances in energy efficiency, renewable energy, and environmentally sound and cutting-edge technology and practices. ORNL is committed to accelerating the deployment of these advances in support of DOE’s goal of catalyzing the timely, material, and efficient transformation of the nation’s energy system and securing US leadership in clean energy technologies. A comprehensive modernization effort, undertaken to provide ORNL with a 21 st century research environment, provided the starting point for the Sustainable Campus Initiative, a 10-year effort to achieve benchmark levels of sustainability across ORNL. This aggressive campaign will continue the transformation of ORNL’s physical environment and enable us to meet DOE goals for energy management and environmental performance. As outlined in this report, the Sustainable Campus Initiative is leveraging the outcomes of our DOE-sponsored R&D programs to maximize the efficient use of energy and natural resources across ORNL. Wherever possible, ORNL is integrating technical innovations into new and existing facilities, systems, and processes. We continue to pursue and deploy innovative solutions and initiatives to advance regional, national, and worldwide sustainability. We are also taking actions to transform ORNL’s culture and engage employees in supporting sustainability at work, at home, and in the community. In its current structure, ORNL’s Sustainable Campus Initiative consists of 26 unique projects or roadmaps, ranging from foundational methods to transformational technologies as represented in Figure 1.

Nichols, Teresa A.↗

Statistical Techniques For Real-time Anomaly Detection Using Spark Over Multi-source VMware Performance Data

Anomaly detection refers to the identi cation of an irregular or unusual pat- tern which deviates from what is standard, normal, or expected. Such deviated patterns typically correspond to samples of interest and are assigned different labels in different domains, such as outliers, anomalies, exceptions, or malware. Detecting anomalies in fast, voluminous streams of data is a formidable chal- lenge. This paper presents a novel, generic, real-time distributed anomaly detection framework for heterogeneous streaming data where anomalies appear as a group. We have developed a distributed statistical approach to build a model and later use it to detect anomaly. As a case study, we investigate group anomaly de- tection for a VMware-based cloud data center, which maintains a large number of virtual machines (VMs). We have built our framework using Apache Spark to get higher throughput and lower data processing time on streaming data. We have developed a window-based statistical anomaly detection technique to detect anomalies that appear sporadically. We then relaxed this constraint with higher accuracy by implementing a cluster-based technique to detect sporadic and continuous anomalies. We conclude that our cluster-based technique out- performs other statistical techniques with higher accuracy and lower processing time.

Apache Spark↗

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings

California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASSESSMENT OF DYNAMIC PRA TECHNIQUES WITH INDUSTRY AVERAGE COMPONENT PERFORMANCE DATA

In the nuclear industry, risk monitors are intended to provide a point-in-time estimate of the system risk given the current plant configuration. Current risk monitors are limited in that they do not properly take into account the deteriorating states of plant equipment, which are unit-specific. Current approaches to computing risk monitors use probabilistic risk assessment (PRA) techniques, but the assessment is typically a snapshot in time. Living PRA models attempt to address limitations of traditional PRA models in a limited sense by including temporary changes in plant and system configurations. However, information on plant component health are not considered. This often leaves risk monitors using living PRA models incapable of conducting evaluations with dynamic degradation scenarios evolving over time. There is a need to develop enabling approaches to solidify risk monitors to provide time and condition-dependent risk by integrating traditional PRA models with condition monitoring and prognostic techniques. This paper presents estimation of system risk evolution over time by integrating plant risk monitoring data with dynamic PRA methods incorporating aging and degradation. Several online, non-destructive approaches have been developed for diagnosing plant component conditions in nuclear industry, i.e., condition indication index, using vibration analysis, current signatures, and operational history [1]. In this work the component performance measures at U.S. commercial nuclear power plants (NPP) [2] are incorporated within the various dynamic PRA methodologies [3] to provide better estimates of probability of failures. Aging and degradation is modeled within the Level-1 PRA framework and is applied to several failure modes of pumps and can be extended to a range of components, viz. valves, generators, batteries, and pipes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of dynamic PRA techniques with industry average component performance data - 208

In the nuclear industry, risk monitors are intended to provide a point-in-time estimate of the system risk given the current plant configuration. Current risk monitors are limited in that they do not properly take into account the deteriorating states of plant equipment, which are unit-specific. Current approaches to computing risk monitors use probabilistic risk assessment (PRA) techniques, but the assessment is typically a snapshot in time. Living PRA models attempt to address limitations of traditional PRA models in a limited sense by including temporary changes in plant and system configurations. However, information on plant component condition is not considered. This often leaves risk monitors using living PRA models incapable of conducting evaluations with dynamic degradation scenarios evolving over time. There is a need to develop enabling approaches to solidify risk monitors to provide time- and condition-dependent risk by integrating traditional PRA models with condition monitoring and prognostic techniques. This paper presents an estimation of system risk evolution over time by integrating plant risk monitoring data with dynamic PRA methods that incorporate aging and degradation. Several online, nondestructive approaches have been developed for diagnosing plant component conditions in the nuclear industry, i.e., using a condition indication index, vibration analysis, current signatures, and operational history . In this work, the component performance measures at U.S. commercial nuclear power plants are incorporated within the dynamic PRA methodologies to provide better estimates of the probability of failures. Aging and degradation are modeled within the Level 1 PRA framework, are applied to several failure modes of pumps, and can be extended to a range of components, namely, valves, generators, batteries, and pipes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methods for Analysis of Outdoor Performance Data (Presentation)

The ability to accurately predict power delivery over the course of time is of vital importance to the growth of the photovoltaic (PV) industry. Two key cost drivers are the efficiency with which sunlight is converted to power and secondly how this relationship develops over time. The accurate knowledge of power decline over time, also known as degradation rates, is essential and important to allstakeholders--utility companies, integrators, investors, and scientists alike. Different methods to determine degradation rates and discrete versus continuous data are presented, and some general best practice methods are outlined. In addition, historical degradation rates and some preliminary analysis with respect to climate are given.

14 SOLAR ENERGY↗

Deciphering Degradation: Machine Learning on Real-World Performance Data

The solar investment community is in need of up-to-date and data-derived system degradation rates to use in financial models that calculate the risk and expectation of energy revenue. To date, financial models choose degradation rates from past studies that are limited and may not be representative of solar projects in development today. As the solar industry expands in all sectors (residential, commercial, and utility), there is a growing amount of energy generation data available to analyze. With the help of the open source degradation analysis code (RdTools) it is now possible to derive degradation on an ongoing basis and continuously provide up-to-date durability statistics to the investment community. Ongoing and accurate statistics of fielded photovoltaic systems allows financial stakeholders to constrain energy revenue projections, lower financial risk, and increase the bankability of solar. This presentation will provide a mid-term progress update on a 2 year SETO-funded degradation project that involves applying RdTools analysis on kWh Analytics’ industry database. With results from the RdTools analysis in hand, machine learning methods are employed to quantify how much variance of system performance degradation can be explained by predictor variables such as environmental factors, equipment bill of materials characteristics, and system design information. The goal of this presentation is to promote the usage of RdTools on an ongoing to data owners and to solicit feedback from researchers and stakeholders on how to maximize impact of the SETO-funded kWh Analytics degradation project.

14 SOLAR ENERGY↗