At least 91 records · Page 5

Material Failure Mechanisms of Alkaline Zn Rechargeable Conversion Electrodes

Zinc (Zn) alkaline electrodes hold great importance and promise in the battery technology community, yet their behavior in real-world applications is still poorly understood. Here, we report a study of failure mechanisms and material evolution during cycling of 27 zinc–manganese dioxide (Zn–MnO 2 ) cells wherein the percent utilization of the Zn electroactive material is systematically varied between 1 and 16%. Cell fabrication is kept typical of the prevailing industrial cell design. The cycle life ranges from 2800 to 60, depending inversely on the Zn utilization. In all cases, the Zn material microstructure sheds the polytetrafluoroethylene (PTFE) binder and forms zinc oxide (ZnO) rods, with longer rods formed by lower current per Zn mass. Irreversible side reactions such as the hydrogen evolution reaction (HER), short circuits, or gas crossover cause the Zn anode’s charging efficiency to average 92% (as low as 86%), which in turn causes the baseload of metallic Zn to gradually disappear. Cell failure occurs after the baseload of metallic Zn is exhausted. The total lifetime discharge capacity remains constant near 12 ± 5 Ah/g Zn invariant of Zn utilization, which suggests that the aforementioned processes of Zn microstructural evolution and side-reaction destruction of baseload metallic zinc both progress linearly with cell capacity throughput. Manual reproduction of individual Zn failure mechanisms is performed in 22 fresh cells. Tight packing of the microstructure can lead to poor mass transfer, which causes supersaturation of soluble Zn and finally produces a high overvoltage during discharge. Here, the low charging current density yields poor coulombic efficiency due either to the competitive HER or soft short circuits.

25 ENERGY STORAGE↗

Insights into the Chemistry of the Cathodic Electrolyte Interphase for PTFE-Based Dry-Processed Cathodes

Dry processing is a promising method for high-performance and low-cost lithium-ion battery manufacturing which uses polytetrafluoroethylene (PTFE) as a binder. However, the electrochemical stability of the PTFE binder in the cathodes and the generated chemistry of the cathode electrolyte interphase (CEI) layers are rarely reported. In this work, the CEI properties and PTFE electrochemical stability are studied via cycling the high-loading dry-processed electrodes in electrolytes with LiPF 6 or LiClO 4 salt. Using LiClO 4 salt can eliminate other possible F sources, allowing the decomposition of PTFE to be studied. The detection of LiF in cells with the LiClO 4 salt confirms that PTFE undergoes side reaction(s) in the cathodes. When compared with LiClO 4 , the CEI layer is much thicker when LiPF 6 is used as the electrolyte salt. These results provide insights into the CEI layer and may potentially enlighten the development of binders and electrolytes for the high efficiency and long durability of DP-based LIBs.

25 ENERGY STORAGE↗

Fluoropolymer Composites from Partially Perfluoroalkylated Waste Polyethylene

Chemically modified plastics have emerged as practical solutions to plastic waste increases. Here, the inherent novelty of decorating polymer chains with chemical functionality results in distinct properties that expand the available application space. Nevertheless, developing designer materials for specific applications beyond compatibilization or mild property enhancement is difficult due to the synergistic effects of both the polar functionality imparted and the parent materials' intrinsic properties. By incorporating perfluoro-alkyl side-chains onto the backbone of dehydrogenated waste HDPE, unique surface properties intermediate between polytetrafluoroethylene (PTFE, the model fluoropolymer) and HDPE become apparent, while the overall material mechanical and thermal properties result in more LLDPE-like materials. This is demonstrated through moderate decreases in the surface free energy of the perfluoroalkylated polyolefin surface (increase in H 2 O contact angle of ~ 6°) and increased ordering under shear when blended with PTFE nanoparticles where the crossover point occurred at higher strains. Critically, perfluoroalkylated HDPE possesses improved rheological modification properties at elevated temperatures with PTFE nanoparticles, resulting in more thermally robust and stable composite materials.

fluoropolymer↗

Effects of a Layered Morphology on Drip Suppression in Burning Polymers

Fire safety in polymers is critically important with products such as textiles and consumer goods, as well as materials used in construction, aerospace, transportation, and furniture. Additives used as anti-dripping and flame-retardant agents impose acute human health issues and have negative environmental impacts. With a focus on developing additive-free solutions, here we used multilayer coextrusion to fabricate layered polyethylene/polypropylene (PE/PP) films and investigated the effect of a layered morphology on dripping and burning rates. The experimental results for multilayered PE/PP samples were compared to control groups of melt blended PE/PP samples. The multilayer configuration provides two significant advantages: 154% delay in the time to the first drip and up to 87% reduction in the number of drips compared to the value for the melt blended samples with no additives. PE/PP blends with up to 2 wt % polytetrafluoroethylene, a commonly used anti-dripping agent in the industry, showed only 85% delay in the time to the first drip and about 60% reduction in the number of drips. We discovered a linear relationship between film thickness and burning rate, which allows for the use of the volumetric burning rate to normalize the effect of film thickness. No benefit in the burning rate was observed when comparing multilayered structures and conventional melt blended architectures or blends with PTFE. Annealing studies and transmission electron microscopy at areas close to the combustion zones confirmed that higher extensional viscosities induced by the layered structures and morphological changes due to the layer breakup play an important role in reducing dripping. By combining the first drip time and overall drip numbers, a parameter, “dripping index”, was defined to establish a fire safety map to simplify material comparisons. This study demonstrates that a multilayer film geometry can provide an additive-free solution to yield control over fire safety parameters in polymers.

36 MATERIALS SCIENCE↗

Impact of Organic and Volatile Compounds in Produced Water from Unconventional Reservoirs on Direct Contact Membrane Distillation Permeate Quality

The expansion of oil and gas extraction from unconventional reservoirs has led to an increase in the amount of produced water that has to be managed by this industry. Direct contact membrane distillation (DCMD) is a promising technology for treatment of produced water to enable water recovery and reduce the environmental footprint of this industry. The feasibility of DCMD for the treatment of highly saline produced water from the Permian Basin in TX with commercially available polyethylene and polytetrafluoroethylene membranes was evaluated in this study. An increase in water recovery by a DCMD system operated in the batch (concentrating) mode led to an increase in permeate conductivity. Partial removal of organic compounds from the produced water by biodegradation, chemical oxidation, and/or activated carbon adsorption could not resolve deterioration in permeate quality, and none of the organics observed in the permeate contributed to its conductivity. The observed increase in permeate conductivity was attributed to the passage of ammonia vapor from the feed side followed by protonation on the permeate side. Furthermore, this study revealed that permeate conductivity may not always be a reliable indicator of membrane wetting and underscores the importance of understanding the interactions between specific solutes and membrane materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing carbon dioxide gas-diffusion electrolysis by creating a hydrophobic catalyst microenvironment

Electroreduction of carbon dioxide (CO 2 ) over copper-based catalysts provides an attractive approach for sustainable fuel production. While efforts are focused on developing catalytic materials, it is also critical to understand and control the microenvironment around catalytic sites, which can mediate the transport of reaction species and influence reaction pathways. Here, we show that a hydrophobic microenvironment can significantly enhance CO 2 gas-diffusion electrolysis. For proof-of-concept, we use commercial copper nanoparticles and disperse hydrophobic polytetrafluoroethylene (PTFE) nanoparticles inside the catalyst layer. Consequently, the PTFE-added electrode achieves a greatly improved activity and Faradaic efficiency for CO 2 reduction, with a partial current density >250 mA cm -2 and a single-pass conversion of 14% at moderate potentials, which are around twice that of a regular electrode without added PTFE. The improvement is attributed to a balanced gas/liquid microenvironment that reduces the diffusion layer thickness, accelerates CO 2 mass transport, and increases CO 2 local concentration for the electrolysis.

36 MATERIALS SCIENCE↗

Fabrication of a composite anion exchange membrane with aligned ion channels for a high-performance non-aqueous vanadium redox flow battery

Fabrication of high-conductivity ion exchange membranes (IEMs) is crucial to improve the performance of non-aqueous vanadium redox flow batteries (NAVRFBs). In the present work, anion exchange membranes with high-conductivity were fabricated by aligning ion channels of the polymer electrolyte impregnated in porous polytetrafluoroethylene (PTFE) under electric fields. It was observed that the ion channels of the polymer electrolyte were uniformly orientated in the atomic-force microscopy image. Its morphological change could minimize detouring of the transport of BF 4 - ions. The results showed through-plane conductivity was improved from 12.7 to 33.1 mS cm -1 . The dimensional properties of the fabricated membranes were also enhanced compared with its cast membrane owing to the reinforcing effect of the substrate. Especially, the NAVRFB assembled with the optimized membrane showed increased capacities, with a 97% coulombic efficiency and 70% energy efficiency at 80 mA cm -2 . Furthermore, the optimized membrane made it possible to operate the NAVRFB at 120 mA cm -2 . Its operating current density was 120 times higher than that of a frequently used AHA membrane for RFBs.

25 ENERGY STORAGE↗

Low-cost desalination of seawater and hypersaline brine using nanophotonics enhanced solar energy membrane distillation

A stand-alone small-scale nanophotonics enhanced solar membrane distillation (NESMD) testbed was designed, developed, and tested for desalinating seawater and high salinity feedwaters. This NESMD system can take almost any source water and turn it into clean water with sunlight as the only energy source. The NESMD technology applies nanophotonic coating materials on a commercial hydrophobic polypropylene support of a polytetrafluoroethylene (PTFE) membrane surface. The photothermal coating serves as a solar thermal collector, absorbs solar energy, and generates highly localized heat on the membrane, while the rest of the membrane performs membrane distillation functions. The presented NESMD system is equipped with an internal heat recovery system with no need for external electricity and no additional water for cooling. The NESMD testbed is installed and tested at Rice University campus (29.7174° N, 95.4018° W). In this study, real seawater from Galveston Bay, Texas, U.S. and high salinity simulated feedwaters (total dissolved solids (TDS) of 113 200–200 000 PPM) have been tested for long-term testing under the weather conditions of Houston, Texas. Here, the field testing results showed stable desalination performance in consecutive 5–8 hour operation cycles, with a TDS removal of ≥99.5% in all experiments. An average daily membrane flux of ≥0.75 L m –2 h –1 was achieved at a solar intensity close to 1 kW m –2 without an external heat exchanger. Further investigations and improvements are required to enhance the performance of the reactor since it is still a new promising technology.

14 SOLAR ENERGY↗

Fatty acid foams for nonselective physical removal of microplastics from aqueous solutions

Microplastics (MPs) are pervasive environmental contaminants whose removal from water remains a major challenge due to their small size, chemical diversity, and dynamic surface properties arising from environmental aging/weathering. Here, we present a concept of foam-based separation method that physically traps MPs in the foam phase using microtubular assemblies of 12-hydroxystearic acid. These foams are stabilized by anisotropic fatty acid microtubules formed in the presence of ethanolamine, which jam within the foam channels and suppress fluid drainage thereby enhancing MP retention and foam stability. MPs of different sizes, polymer compositions (including polystyrene, polypropylene, polyethylene terephthalate, and polytetrafluoroethylene), and weathered states were retained in the foam phase without requiring chemical modification or relying on chemical interactions between the fatty acid and MPs. Thermally induced transition of the fatty acid microtubules into nanomicelles above the characteristic phase transition temperature (∼35 °C) enables controlled foam collapse and recovery of trapped MPs. The cumulative removal efficiency can exceed 85% through multiple foaming cycles, matching predictions from a probabilistic retention model. This work shows that foams can provide a simple platform to trap MPs, thus providing a new physical-removal strategy that does not rely on the particles’ chemistry.

Guillot, Kennedy A. [Louisiana State Univ., Baton ↗

Spectroscopic investigation of early light emission from anode-initiated surface flashover in vacuum

Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the spin-component-scaled methods for energy bands

The performance of various spin-component-scaled parameterisations is examined for the second-order many-body Green's-function [MBGF(2)] calculations of valence energy bands, taking three of the experimentally well-characterised polymers as examples: polyethylene, polytetrafluoroethylene, and polyacetylene. The parameterisations considered are Grimme's original SCS parameter set, Jung et al.'s original SOS set (retaining the opposite-spin component only), Śmiga et al.'s SCS(IP) set (calibrated specifically for ionization energies), and Śmiga et al.'s SOS(IP) set (calibrated for ionization energies with the opposite-spin component only; implicit in the os-D2 model of Opoku et al.). The SCS(IP) and SOS(IP) parameterisations are found to shift both outer and inner valence bands by up to a few electronvolts away from the experimental data. The original SCS and SOS parameter sets do not improve upon, but largely maintain the accuracy of the unscaled MBGF(2) methods. Given that the SOS-MBGF(2) method can be implemented in a quartic-scaling algorithm (for all roots), it is most promising for solid-state applications. Furthermore this observation is consistent with the success of the quartic-scaling GW methods without the vertex correction based on a density-functional theory reference.

Green’s-function theory↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Engineering Microstructure in Dry-Processed Cathodes Via Calendering

Calendering serves as a multifunctional step in dry electrode processing that not only densifies the electrode but also induces polytetrafluoroethylene (PTFE) fibrillation and reorganizes the microstructure. These coupled effects are essential for achieving electrical connectivity and sufficient cohesion, yet they also introduce trade-offs, such as active material particle fracture, pore collapse, and excessive porosity loss, that can hinder ionic transport. This research systematically maps the calendering parameter space for LiNi0.6Mn0.2Co0.2O2 (NMC622) dry cathodes with a target thickness of ∼100 µm and porosity of ∼30% by varying roll gaps, roll temperature, roll speed, and the number of passes. A practical processing window for this formulation and electrode architecture is identified that achieves sufficient PTFE fibrillation and strong interfacial contact while minimizing particle fracture and preserving the porosity required for efficient ionic transport. In particular, gradual-gap calendering with moderate per-pass compression mitigates fracture and pore collapse while still reaching the target thickness with reasonable throughput, and slower roll speeds with modest roll temperatures further reduce mechanical damage. These results provide actionable guidance for scaling NMC622-based thick dry-processed cathodes.

Park, Hyunji↗