Search NASA⌕ Search

SEARCH · Search NASA

Results for “proficiency test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

Grout testing to support tank closure at the Savannah River Site - 15370

Final operational closure of the Savannah River Site (SRS) waste tanks is performed by filling the voids inside the tanks with a series of tailored grout formulas thereby stabilizing the remaining residuals. These tailored grout formulas were each developed to meet the demands of the closure process. The needs identified for the closure process include (1) a flowable, self-consolidating, reducing grout for tank fill, (2) a highly flowable grout capable of filling the 7-1/4 kilometers (4-1/2 miles) of 5-centimeter (2-inch) diameter cooling coils inside the tank, and (3) a highly flowable grout capable of filling equipment remaining in the tank. The specific characteristics of each of the grout formulations were tested to ensure they would function as required during implementation. Performance testing was also done on some of the grout formulations to confirm mix effectiveness and improve worker handling proficiency and conducted additional testing on the bulk fill grout to expand the placement capabilities of the grout. This paper focuses on the evolution of the closure process' identified needs, formulation development, and the subsequent testing of the tailored grout formulations utilized in the past tank closure processes at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man-made radioisotopes. Spectral data can also identify specific radioactive isotopes. Based on the results of the RSL NTS 1994 surveys, this area was chosen for a resurvey to improve the spatial resolution of the reported depositions for the Johnnie Boy and Little Feller I events. In addition, the survey was expected to confirm the absence of detectable concentrations of Americium-241 (Am-241) at the Johnnie Boy site and attempt to confirm the presence of Uranium-235 (U-235).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Data Collection Analysis (IDCA) Program - NaClO 3 /Icing Sugar

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of NaClO 3 and icing sugar—NaClO 3 /icing sugar mixture. The mixture was found to: be more sensitive than RDX but less sensitive than PETN in impact testing (180-grit sandpaper); be more sensitive than RDX and about the same sensitivity as PETN in BAM fiction testing; be less sensitive than RDX and PETN except for one participant found the mixture more sensitive than PETN in ABL ESD testing; and to have one to three exothermic features with the lowest temperature event occurring at ~ 160°C always observed in thermal testing. Variations in testing parameters also affected the sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — Ammonium Nitrate

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of ammonium nitrate (AN). AN was tested, in most cases, as both received from manufacturer and dried/sieved. The participants found the AN to be: 1) insensitive in Type 12A impact testing (although with a wide range of values), 2) completely insensitive in BAM friction testing, 3) less sensitive than the RDX standard in ABL friction testing, 4) less sensitive than RDX in ABL ESD testing, and 5) less sensitive than RDX and PETN in DSC thermal analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Side effects of antimotion sickness drugs

The effects on operational proficiency of the antimotion sickness drugs scopolamine, promethazine and d-amphetamine are tested using a computerized pursuit meter. Proficiency is not significantly affected by oral doses of 0.25 mg or 0.50 mg scopolamine but is descreased by oral or I.M. doses of 25 mg promethazine. The performance decrement associated with 25 mg oral promethazine is prevented when combined with 10 mg oral d-amphetamine. The combination of 25 mg I.M. promethazine, 25 mg oral promethazine and 10 mg d-amphetamine produces less performance decrement than oral or I.M. doses of promethazine alone, though more performance decrement than a placebo. I.M. promethazine is adsorbed slowly and consequently may provoke drowsiness.

Wood, C. D.↗

Integrated Data Collection Analysis (IDCA) Program — Bullseye ® Smokeless Powder

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of Bullseye ® smokeless powder (Gunpowder). The participants found the Gunpowder: 1) to have a range of sensitivity to impact, from less than RDX to almost as sensitive as PETN, 2) to be moderately sensitive to BAM and ABL friction, 3) have a range for ESD, from insensitive to more sensitive than PETN, and 4) to have thermal sensitivity about the same as PETN and RDX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Analysis (IDCA) Program - PETN Class 4 Standard

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of PETN Class 4. The PETN was found to have: 1) an impact sensitivity (DH 50 ) range of 6 to 12 cm, 2) a BAM friction sensitivity (F 50 ) range 7 to 11 kg, TIL (0/10) of 3.7 to 7.2 kg, 3) a ABL friction sensitivity threshold of 5 or less psig at 8 fps, 4) an ABL ESD sensitivity threshold of 0.031 to 0.326 j/g, and 5) a thermal sensitivity of an endothermic feature with T min = ~ 141 °C, and a exothermic feature with a T max = ~205°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ABL and BAM Friction Analysis Comparison

Here, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here is a comparison of the Alleghany Ballistic Laboratory (ABL) friction data and Bundesanstalt fur Materialforschung und -prufung (BAM) friction data for 19 HEM and military standard explosives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — KClO 3 /Icing Sugar (-100 mesh) Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a mixture of KClO 3 sized through a 100-mesh sieve mixed with icing sugar, also sized through a 100-mesh sieve—KClO 3 /icing sugar (-100) mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solid materials. The mixture was found to be: 1) more sensitive to impact than RDX, with sensitivity similar to PETN, 2) the same or more sensitive to friction than PETN, and 3) less sensitive to spark than RDX. The analysis showed that the mixture has thermally stability similar to RDX and is perhaps more energetic upon decomposition but variable results indicate sampling issues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — KClO 3 (as received)/Icing Sugar

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 3 as received from the manufacturer mixed with icing sugar, sized through a 100-mesh sieve—KClO 3 /icing sugar (AR) mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solid materials. The mixture was found to: 1) be more sensitive to impact than RDX, similar to PETN, 2) be the same or less sensitive to friction than PETN, and 3) to be less sensitive to spark than RDX. The thermal analysis showed that the mixture has thermally stability similar to RDX and is perhaps more energetic upon decomposition but variable results indicate sampling issues. Compared to the 100-mesh sieved counter part, the KClO 3 /icing sugar (-100) mixture, the AR mixture was found to be about the same sensitivity towards impact, friction and ESD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Manual Crew Override of Vehicle Landings Following G-Transitions

BACKGROUND Manual control during exploration spaceflight consists of both planned automated supervisory control and unplanned crew override. This crew override capability is critical to enable overall mission success during landing contingencies. However, the introduction of manual override capabilities must be implemented to enable crews to mitigate risks introduced by human error. Adaptive changes in the sensorimotor system can manifest during g-transitions as spatial disorientation. While training and landing aids enable successful landing through disorientation, these adaptive changes may increase cognitive demand that needs to be accounted for in the manual control strategy. It is important to characterize these effects as soon as possible following the G-transition to develop appropriate countermeasures. METHODS The following study seeks to inform the risk associated with altered sensorimotor and vestibular function impacting critical mission tasks. We aim to characterize the effects of short and long-duration weightlessness on manual control following G-transitions using simulated lunar landing on a six-degree-of-freedom (6DOF) motion base, a fixed base simulation, and a supervisory control tablet task. The primary goal is to understand the impact of spaceflight on crew ability to perform manual crew override and supervisory control. This aim will be assessed by comparing pre- versus postflight simulation performance in crewmembers assigned to either short duration (< 30 day) or long duration (~6- month) missions to the International Space Station (ISS). We hypothesize there will be postflight increases in the percent time that pilots are outside of the acceptable range for recommended vehicle state parameters and the reaction time for secondary cognitive tasks. Ground-based control subjects, who are demographically matched to the crew considering age (± 5 years) and gender, will undergo the same testing schedule as the crew to examine the effects of flight phase independent of microgravity exposure. The second aim is to examine how adaptive changes in vestibular and cognitive function relate to changes in manual crew override proficiency. Crew performance for a sensorimotor perceptual test battery will evaluate motion perception tracking, roll nulling, and/or vection sensitivity using the 6DOF motion base. We hypothesize that a higher severity of vestibular alterations will be associated with increased percent time outside of guidance limits. Motion sickness severity and sleepiness will also be evaluated. To determine the impact of “just-in-time” training, the third aim seeks to compare performance during on-board lunar landing tasks conducted late in-flight to early postflight. We hypothesize that proficiency on the “just-in-time” laptop trainer late in mission will be positively correlated with early postflight proficiency on the same task. The final aim will establish assessments of performance, training protocols, and the learning progression in a ground-control cohort of first-time users. RESULTS The assessment of the learning progression associated with the piloting task on the motion base system with thirty ground subjects will be reported. Learning curves will be established across four distinct sessions and within session considering trial difficulty. The difficulty of the landing task can be modulated with the landing divert distance and cross or downrange difficulty. Results may include changes in performance across multiple trials of a multi-attribute lunar tablet supervisory control task. Preliminary investigations of eighteen subjects who completed vestibular threshold and motion perception tasks offer expected performance ranges for upcoming preflight crew evaluations. The results yielded an average roll threshold of 0.46 ± 0.30 deg/s and an average roll nulling root mean square error performance of 2.52 ± 0.52 deg/s. RELEVANCE This project will deliver an operational demonstration of crew monitoring capability following spaceflight and identify potential deficits that may require remediation. Comparison of individual vestibular and cognitive changes with crew performance will help better characterize the manual control risks associated with sensorimotor alterations. Ground testing will evaluate learning progression, refine training protocols, and serve as a control cohort for comparisons to crew performance. ACKNOWLEDGEMENTS: The authors acknowledge contributions from Draper, the Dynamic Skills Trainer (DST) Lab, and the Software, Robotics, and Simulation Division toward the development of the lunar landing simulation platforms. This project is funded by the Human Health Countermeasures Element.

Hannah M. Weiss↗

Medical operations: Crew surgeon's report

To assure the safety and well being of the Skylab environment simulation crewmembers it was necessary to develop a medical safety plan with emergency procedures. All medical and nonmedical test and operations personnel, except those specifically exempted, were required to meet the medical standards and proficiency levels as established. Implemented programs included health care of the test crew and their families, occupational medical services for chamber operating personnel, clinical laboratory support and hypobaric and other emergency support.

Ross, C. E.↗

Hanford WTP LAW Melter Startup and Tuning Feed Material Development - 17065

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington state is home to 56 million gallons of chemical and radioactive waste stored in underground tanks, the result of more than four decades of plutonium production. To address this challenge, the U.S. Department of Energy contracted Bechtel National, Inc., to design and build the world's largest radioactive waste treatment plant. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will use vitrification to immobilize most of Hanford's waste. Vitrification involves blending the waste with glass-forming materials, and heating it to high temperature to form molten glass, then pouring it into stainless steel containers. In this glass form, its radioactivity will decay over hundreds to thousands of years. In advance of full operation of WTP, a sequential process of commissioning will be undertaken to ensure the plant operates safely and within design requirements. The first phase of WTP operations will focus on the Low-Activity Waste (LAW) Vitrification Facility and its supporting facilities and systems. Commissioning of the LAW Facility will employ a progressive approach to address the complexity of system operation and introduction of hazards. This approach starts with introduction of low hazard and simple testing configurations, and incrementally increasing the complexity and hazardous makeup of testing feed materials, culminating in fully integrated treatment of radioactive tank waste during hot commissioning. Testing with simulants that are chemically similar to radioactive tank waste introduces significant chemical hazards into treatment systems in the form of nitrogen oxides (NOx) and anhydrous ammonia. A method of testing to allow tuning and demonstration of equipment and to develop operator proficiency prior to introducing these chemical hazards was deemed necessary. To that end, the development and testing of a new 'tuning feed' material is in progress. The tuning feed is important because its use will enable the first-time integration of all LAW Facility process systems. The tuning feed must include key physical and chemical characteristics that correspond to the commissioning simulant and low activity tank waste, without the inherently hazardous materials or toxic off-gas constituents that result from tank waste treatment. Tuning feed is being developed to provide representative melter feed rheology, glass chemistry, cold cap formation, and off-gas generation rate in order to predict system response to actual tank waste to the extent practical. The tuning feed must also be compatible with process equipment and other process streams that will be encountered during the cold commissioning testing program. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Ultem 1000, 1010, and 9085 for Radome Applications at 24.5 GHz

The UAS in the NAS project Flight Test 6 (FT6) campaign scheduled for FY19Q3 will evaluate the proficiency of a Honeywell DAPA-Lite Radar installed on a Tiger Shark unmanned vehicle to detect the presence of air traffic operating in its vicinity. A 3D printed radome will be manufactured for the front of the Tiger Shark to enclose the radar during FT6 operations. The DAPA-Lite radar operates in the 24.5 GHz frequency band. Material properties of 3D printer filaments are widely available for the mechanical and thermal properties, but limited knowledge exists on the electrical properties for radome applications and no data was found to correspond at the 24.5 Ghz frequency band. To minimize project risk associated with the radome performance, transmissivity and reflectivity measurements were conducted on two candidate 3D printed dielectric material filaments (Ultem 1010 Natural and Ultem 9085 Black) and two thicknesses of a solid laminate (Ultem 1000) material. The 3D printed Ultem coupons were tested shortly after being printed and again 8 months later to examine ageing effects of the open cell structure. This paper presents the transmissivity and reflectivity measurement results collected on the Ultem coupons and concludes the 3D printed 1010 Natural coupon is a suitable candidate filament for radome applications at 24.5 GHz. The design of the structure’s open cell matrix has a significant impact on the material’s surface reflectivity.

Szatkowski, George N.↗

Diagnostic instrumentation aboard ISS: just-in-time training for non-physician crewmembers

INTRODUCTION: The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). METHODS: An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. RESULTS: Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. CONCLUSIONS: Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.

Inservice Training/methods↗

Accelerated Training at Mach 20: A Brief Communication Submitted from the International Space Station

The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed just-in-time training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This just-in-time concept was used to support real-time remote expert guidance to complete medical examinations using the ISS Human Research Facility (HRF). An American and Russian ISS crewmember received 2-hours of hands on ultrasound training 8 months prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember six days prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. Results of the CD ROM based OPE session were used to modify the instructions during a complete 35 minute real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were excellent and adequate for clinical decision-making. Complex ultrasound experiments with expert guidance were performed with high accuracy following limited pre-flight training and CD-ROM-based in-flight review, despite a 2-second communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, can facilitate the performance of complex demanding tasks.

Foale, C. Michael↗

Variation of methods in small-scale safety and thermal testing of improvised explosives

Here, one of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of homemade or improvised explosives (HMEs) to SSST testing, 16 HME materials were compared to 3 standard military explosives in a proficiency-type round robin study among five laboratories, two U.S. Department of Defense and three U.S. Department of Energy, sponsored by the Department of Homeland Security, Science & Technology Directorate, Explosives Division.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗