Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Infrared thermometry in high temperature materials processing: influence of liquid water and steam

Here, the capability of four infrared thermometry techniques (2-colour and 1-colour pyrometers, Pyrolaser and IR camera) was evaluated with respect to the impact of water or steam in the line of sight to determine temperature from two heat sources (blackbody calibration source and steel block inside the furnace). The influence of liquid water on the temperature readings was minimal when using 2-colour pyrometry due to comparable absorption coefficients of water for the measured wavelengths. The signals measured using both the Pyrolaser and the 1-colour pyrometer were decreased due to the partial absorption and resulted in an apparent temperature lower than the actual. Water readily absorbed the IR signal in the range of the IR camera operation, resulting in no signal whenever liquid water was present in the line of sight. Steam caused the most deviation and fluctuation of temperature readings for all techniques due to the large level of light scattering in addition to the absorption of the radiant energy. A technique was developed to determine the transmissivity (apparent emissivity) when water or steam is in the line of sight of measurement. An approximate correction to the measurements based on Planck’s law is discussed for both 2-colour and 1-colour pyrometers.

2-colour and 1-colour pyrometry↗

Comparison of pyrometry and thermography for thermal analysis of thermite reactions

This article examines the thermal behavior of a laser ignited thermite composed of aluminum and bismuth trioxide. Temperature data were collected during the reaction using a four-color pyrometer and a high-speed color camera modified for thermography. The two diagnostics were arranged to collect data simultaneously, with similar fields of view and with similar data acquisition rates, so that the two techniques could be directly compared. Results show that at initial and final stages of the reaction, a lower signal-to-noise ratio affects the accuracy of the measured temperatures. Both diagnostics captured the same trends in transient thermal behavior, but the average temperatures measured with thermography were about 750 K higher than those from the pyrometer. This difference was attributed to the lower dynamic range of the thermography camera’s image sensor, which was unable to resolve cooler temperatures in the field of view as well as the photomultiplier tube sensors in the pyrometer. Overall, while the camera could not accurately capture the average temperature of a scene, its ability to capture peak temperatures and spatial data make it the preferred method for tracking thermal behavior in thermite reactions.

36 MATERIALS SCIENCE↗

Correction-free pyrometry in radiant wall furnaces

A specular, spherical, or near-spherical target is located within a furnace having inner walls and a viewing window. A pyrometer located outside the furnace 'views' the target through pyrometer optics and the window, and it is positioned so that its detector sees only the image of the viewing window on the target. Since this image is free of any image of the furnace walls, it is free from wall radiance, and correction-free target radiance is obtained. The pyrometer location is determined through a nonparaxial optical analysis employing differential optical ray tracing methods to derive a series of exact relations for the image location.

Thomas, Andrew S. W.↗

On-Line, Real-Time Diagnostics of a Single Fluid Atomization System

A drop tube-Impulse Atomization technique was used to produce copper droplets. In this method, energy is transferred to a liquid by plunger movement resulting in spherical droplets emanating from orifices. A mathematical model of the evolution of droplet velocity and temperature at various heights for different sized droplets was developed. A two-color pyrometer, DPV-2000, and a shadowgraph were used to measure droplets radiant energy, diameter and velocity. The temperature values from the model were used to assess the two color pyrometer assumption over the temperature range of measurement. The DVP 2000 measurements were found to be dependent of droplet size wavelength and position of droplets below the atomizing nozzle. By calibrating the instrument for effective emissivity over the range of measurements, the thermal history of droplets may be recorded using a single color pyrometer approach.

DelshadKhatibi, P.↗

Monitoring and prediction of porosity in laser powder bed fusion using physics-informed meltpool signatures and machine learning

In this work we accomplished the monitoring and prediction of porosity in laser powder bed fusion (LPBF) additive manufacturing process. This objective was realized by extracting physics-informed meltpool signatures from an in-situ dual-wavelength imaging pyrometer, and subsequently, analyzing these signatures via computationally tractable machine learning approaches. Porosity in LPBF occurs despite extensive optimization of processing conditions due to stochastic causes. Hence, it is essential to continually monitor the process with in-situ sensors for detecting and mitigating incipient pore formation. In this work a tall cuboid-shaped part (10 mm × 10 mm × 137 mm, material ATI 718Plus) was built with controlled porosity by varying laser power and scanning speed. This test caused various types of porosity, such as lack-of-fusion and keyhole formation, with varying degrees of severity in the part. The meltpool was continuously monitored using a dual-wavelength imaging pyrometer installed in the machine. Physically intuitive process signatures, such as meltpool length, temperature distribution, and ejecta (spatter) characteristics, were extracted from the meltpool images. Subsequently, relatively simple machine learning models, e.g., K-Nearest Neighbors, were trained to predict both the severity and type of porosity as a function of these physics-informed meltpool signatures. These models resulted in a prediction accuracy exceeding 95% (statistical F1-score). The same analysis was carried out with a complex, black-box deep learning convolutional neural network which directly used the meltpool images instead of physics-informed features. The convolutional neural network produced a comparable F1-score in the range of 89–97%. Finally, these results demonstrate that using pragmatic, physics-informed meltpool signatures within a simple machine learning model is as effective for flaw prediction in LPBF as using a complex and computationally demanding black-box deep learning model.

36 MATERIALS SCIENCE↗

Detecting keyhole porosity and monitoring process signatures in additive manufacturing: an in situ pyrometry and ex situ X-ray radiography correlation

Creation of pores and defects during laser powder bed fusion (LPBF) can lead to poor mechanical properties and thus must be minimized. Post-build inspection is required to ensure the printed parts contain acceptably low defect concentrations. These inspections are time consuming and costly, especially for large or complex parts. As a potential solution, in situ process monitoring can be used to detect the creation of defects, characterize local material behavior and predict expected component properties. However, the precise relationship between pore creation and in situ process monitoring still needs to be understood. In this work, high-speed infrared diode-based pyrometry and high-speed optical imaging signals were used to monitor LPBF printing of 446 stainless steel 316 L single tracks with varying laser power and velocity. Results indicate an increase in pyrometer signal and melt pool dimensions with increasing laser power and decreasing velocity in agreement with previous work. In addition, careful analysis of pyrometer signal reveals a distinct signature of the conduction-to-keyhole mode transition which was confirmed by metallography. Critically, pore defect initiation as characterized by ex situ X-ray radiography was correlated with in situ thermal monitoring signals to derive the probability of defect creation. Our results show that, in principle, a probabilistic prediction of pore formation can be achieved based on in situ high-speed pyrometry monitoring of the LPBF melt pool.

36 MATERIALS SCIENCE↗

Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser

An experimental and simulation study of warm dense carbon foams at ambient density (n e ~10 21 cm –3 ) is presented. This study of isochorically heated foams is motivated by their potential application in carbon-atmosphere white-dwarf envelopes, where there are modeling uncertainties due to the equation of state. The foams are heated on an approximately picosecond time scale with a laser-accelerated proton beam. The cooling and expansion of the heated foams can be modeled with appropriately initialized radiation-hydrodynamics codes; xRAGE code is used in this work. The primary experimental diagnostic is the streaked optical pyrometer, which images a narrow band of radiation from the rear surface of the heated material. Presented are xRAGE modeling results for both solid aluminum targets and carbonized resorcinol-formaldehyde foam targets, showing that the foam appears to cool slowly on the pyrometer because of partial transparency. So that simulations of cooling foam are processed properly, it is necessary to account for finite optical depth in the photosphere calculation, and the methods for performing that calculation are presented in depth.

36 MATERIALS SCIENCE↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Ignition phenomena of bulk aluminum alloy as a function of oxygen pressure

An ignition phenomena of 6061 aluminum alloy was investigated as a function of oxygen pressure. Cylindrical aluminum alloy specimens were ignited in a pure oxygen environment by a focused CW CO2 laser beam. The experiments were conducted at oxygen pressures ranging from 0.084 to 2.413 MPa. The temperature history of the entire upper surface of the specimen and of a 0.5 mm diameter spot located initially at the center of the specimen top surface was recorded by using a commercial two-color ratio pyrometer and a fast-response, narrow-band, two-color pyrometer. Mass, brightness, and interior temperatures (for certain experiments) were also recorded throughout the experiment. The results show that the surface temperatures at ignition of the alloy obtained from the temperature curves are below the melting temperature of the aluminum oxide and are slightly dependent on oxygen pressure. The data indicate that the ignition mechanism is complex and probably composed of several phenomena acting both separately and in conjunction with each other.

Nguyen, K.↗

Fast optical pyrometry

Design and operation of accurate millisecond and microsecond resolution optical pyrometers developed at the National Bureau of Standards during the last two decades are described. Results of tests are presented and estimates of uncertainties in temperature measurements are given. Calibration methods are discussed and examples of applications of fast pyrometry are given. Ongoing research in developing fast multiwavelength and spatial scanning pyrometers are summarized.

Cezairliyan, Ared↗

Noncontact temperature pattern measuring device

This invention relates to a noncontact imagine pyrometer system for obtaining the true temperature image of a given substance in a contactless fashion without making assumptions about localized emissivity of the substance or the uniformity of the temperature distribution. Such a contactless temperature imaging system has particular application in the study and production of many materials where the physical contact required to make a conventional temperature measurement drastically effects or contaminates the physical process being observed. Two examples where accurate temperature profiles are of critical interest are: (1) the solid-liquid phase change interface in the production of electronic materials and (2) metastable materials in the undercooling region. The apparent novelty resides in the recognition that an active pyrometer system may be advantageously adapted to perform contactless temperature imaging so that an accurate temperature profile can be obtained.

Elleman, D. D.↗

Non-contact heat flux measurement using a transparent sensor

A working non-contact heat flux sensor was demonstrated using a transparent material (sapphire) and a multiwavelength pyrometer. The pyrometer is used to measure the temperatures of the two surfaces of the sensor from the spectrum of radiation originating from them. The heat conducted through the material is determined from the temperature difference of the two surfaces and the thermal conductivity of the material. The measured heat flux is equal to the incident heat flux within experimental error indicating that no calibration would be necessary. A steady state heat flux of 100 kW/sq m was easily achieved.

Ng, Daniel↗

Correction-free radiometry on specular spheres for containerless processing in microgravity

An analysis is presented that establishes how correction-free radiance measurements or pyrometry can be performed on targets in furnaces where there may be significant additional radiance from heated furnace walls or from reflecting surfaces close to the target. These configurations are common in microgravity and containerless processing applications where a specular target is radiantly heated in a hot-wall furnace, or inductively heated from the fields arising from nearby closely spaced electromagnetic coils. Proper design requires that the pyrometer does not view any images of the background features in the specular target so that stray radiation will not be reflected into the viewing optics of the pyrometer. To analyze the problem, conventional paraxial optics analysis is shown to be significantly in error. Instead a method of nonparaxial ray tracing, based on the derivatives of the ray paths, shows how the images must be located. This leads to analytical results that can be used to design such systems. The findings are applied to the furnace geometries that are presently being considered for flight in LEO.

Thomas, A. S. W.↗

Pyrometric Gas and Surface Temperature Measurements

A multiwavelength pyrometer possessing advantages over the one- and two-wavelength designs is described. Results of its application to surface temperature measurements of ceramics is presented. Also described is a probe suitable for gas temperature measurements to temperatures > 2600 K. The design of the probe includes a multiwavelength pyrometer with fiber optic input.

Fralick, Gustave↗

Broadband IR Measurements for Modis Validation

The primary objective of this research was the development and deployment of autonomous shipboard systems for infrared measurement of ocean surface skin temperature (SST). The focus was on demonstrating long-term, all-weather capability and supplying calibrated skin SST to the MODIS Ocean Science Team (MOCEAN). A secondary objective was to investigate and account for environmental factors that affect in situ measurements of SST for validation of satellite products. We developed and extensively deployed the Calibrated, InfraRed, In situ Measurement System, or CIRIMS, for at-sea validation of satellite-derived SST. The design goals included autonomous operation at sea for up to 6 months and an accuracy of +/- 0.1 C. We used commercially available infrared pyrometers and a precision blackbody housed in a temperature-controlled enclosure. The sensors are calibrated at regular interval using a cylindro-cone target immersed in a temperature-controlled water bath, which allows the calibration points to follow the ocean surface temperature. An upward-looking pyrometer measures sky radiance in order to correct for the non-unity emissivity of water, which can introduce an error of up to 0.5 C. One of the most challenging aspects of the design was protection against the marine environment. A wide range of design strategies to provide accurate, all-weather measurements were investigated. The CIRIMS uses an infrared transparent window to completely protect the sensor and calibration blackbody from the marine environment. In order to evaluate the performance of this approach, the design incorporates the ability to make measurements with and without the window in the optical path.

Jessup, Andrew T.↗

Thermal Conductivity Change Kinetics of Ceramic Thermal Barrier Coatings Determined by the Steady-State Laser Heat Flux Technique

A steady-state laser heat flux technique has been developed at the NASA Glenn Research Center at Lewis Field to obtain critical thermal conductivity data of ceramic thermal barrier coatings under the temperature and thermal gradients that are realistically expected to be encountered in advanced engine systems. In this study, thermal conductivity change kinetics of a plasma-sprayed, 254-mm-thick ZrO2-8 wt % Y2O3 ceramic coating were obtained at high temperatures. During the testing, the temperature gradients across the coating system were carefully measured by the surface and back pyrometers and an embedded miniature thermocouple in the substrate. The actual heat flux passing through the coating system was determined from the metal substrate temperature drop (measured by the embedded miniature thermocouple and the back pyrometer) combined with one-dimensional heat transfer models.

Zhu, Dongming↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗