Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Reversible Colorimetric Sensing of Volatile Analytes By Wicking in Close Proximity to A Photonic Film

Isolation of volatile analytes from environmental or biological fluids is a rate-determining step that can delay the response time for continuous sensing. In this paper, we demonstrate a colorimetric sensing system that enables the rapid detection of gas-phase analytes released from a flowing micro-volume fluid sample. The sensor platform is an analyte-responsive metal-insulator-metal (MIM) thin-film structure integrated with a large area quartz micropillar array. This allows precise planar alignment and microscale separation (310 μm) of the optical and fluidic structures. This configuration offers rapid and homogeneous color changes over large areas that permits detection by low-resolution optics or eye, which is well-suited to portable/wearable devices. For our proof-of-principle demonstration, we utilized a poly(methyl methacrylate) (PMMA) spacer and evaluated the sensor's response (color change) to ethanol vapor. We show that the RGB color value is quantitatively linked to the spacer swelling, which is reversible and repeatable. The optofluidic platform reduces the sensor response time from minutes to seconds compared with experiments using a conventional chamber. The sensor's concentration-dependent response was examined, confirming the potential of the reported sensing platform for continuous, compact, and quantitative colorimetric analysis of volatile analytes in low-volume samples, such as biofluids.

Timothy J. Palinski↗

Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere

Laser remote sensing measurements of trace gases from orbit can provide unprecedented information about important planetary science and answer critical questions about planetary atmospheres. Methane (CH4) is the second most important anthropogenically produced greenhouse gas. Though its atmospheric abundance is much less than that of CO2 (1.78 ppm vs. 380 ppm), it has much larger greenhouse heating potential. CH4 also contributes to pollution in the lower atmosphere through chemical reactions, leading to ozone production. Atmospheric CH4 concentrations have been increasing as a result of increased fossil fuel production, rice farming, livestock, and landfills. Natural sources of CH4 include wetlands, wild fires, and termites, and perhaps other unknown sources. Important sinks for CH4 include non-saturated soils and oxidation by hydroxyl radicals in the atmosphere. Remotely measuring CH4 and other biogenic molecules (such as ethane and formaldehyde) on Mars also has important implications on the existence of life on Mars. Measuring CH4 at very low (ppb) concentrations from orbit will dramatically improve the sensitivity and spatial resolution in the search for CH4 vents and sub-surface life on other planets. A capability has been developed using lasers and spectroscopic detection techniques for the remote measurements of trace gases in open paths. Detection of CH4, CO2, H2O, and CO in absorption cells and in open paths, both in the mid- IR and near-IR region, has been demonstrated using an Optical Parametric Amplifier laser transmitter developed at GSFC. With this transmitter, it would be possible to develop a remote sensing methane instrument. CH4 detection also has very important commercial applications. Pipeline leak detection from an aircraft or a helicopter can significantly reduce cost, response time, and pinpoint the location. The main advantage is the ability to rapidly detect CH4 leaks remotely. This is extremely important for the petrochemical industry. This capability can be used in manned or unmanned airborne platforms for the detection of leaks in pipelines and other areas of interest where a CH4 leak is suspected.

Riris, Haris↗

Cyber Resiliency and the Implementation of a Host-Based Intrusion Detection System in an Urban Air Mobility Environment

With the growth in urban air mobility systems and the increasing reliance on interconnected technologies, ensuring the security of these complex infrastructures has become critical. As cities evolve into smart urban centers, the vulnerability to cyber threats escalates, possibly endangering citizens’ safety and the efficiency of transportation networks. In response to these challenges, this paper presents a study on implementing a Host-Based Intrusion Detection System (HIDS) tailored explicitly to urban mobility environments’ unique demands. This study explores the design, development, and deployment of the proposed HIDS, focusing on its adaptability to monitor the hybrid nature of the urban mobility environment. Leveraging machine learning algorithms and anomaly detection techniques, the HIDS is equipped to continuously monitor and analyze the behavior of individual host systems, vehicles, and devices, thereby providing a proactive approach to threat detection. Implementing a HIDS is a pivotal strategy for enhancing cyber resiliency, as it gives an organization granular visibility into internal system activities, enables rapid detection and response to anomalous behavior and cyber threats, and fortifies the organization’s overall cybersecurity posture. In conclusion, this paper highlights the significance of host-based intrusion detection in urban mobility environments and underscores the necessity of tailored security solutions to safeguard against emerging cyber threats.

UAM↗

Cyber Resiliency and the Implementation of a Host-Based Intrusion Detection System in an Urban Air Mobility Environment

With the growth in Urban Air Mobility systems and the increasing reliance on interconnected technologies, ensuring the security of these complex components has become critical. As cities evolve into smart urban centers, the vulnerability to cyber threats escalates, possibly endangering citizens safety and the efficiency of transportation networks.In response to these challenges, this paper presents a study on the need for cyber resilient techniques within future air traffic environments. It will pay specific attention to the implementation of a Host-Based Intrusion Detection System (HIDS) utilizing Atomic OSSEC software, tailored specifically to a NASA simulation of an UrbanAirMobility environments’ unique demands. Further, this study seeks to outline the rational for NASA’s recommendation for a HIDS in such environments. It explores the design, development, and deployment of the proposed HIDS, focusing on its adaptability to monitor the hybrid nature of the Urban Air Mobility environment. Leveraging machine learning algorithms and anomaly detection techniques, the HIDS is equipped to continuously monitor and analyze the behavior of individual host systems, vehicles, and devices, thereby providing a proactive approach to threat detection. Implementing a HIDS is a pivotal strategy for enhancing cyber resiliency, as it gives an organization granular visibility into internal system activities, enables rapid detection and response to anomalous behavior and cyber threats, and fortifies the organizations overall cybersecurity posture. Finally, this study aims to provide recommendations and include learned takeaways that the Urban Air Mobility industry should consider. In brief, this paper highlights the significance of host-based intrusion detection in UrbanAirMobility environments and underscores the necessity of tailored security solutions to safeguard against emerging cyber threats.

UAM↗

Model-based diagnostics for the SSME

This paper presents models to diagnose the condition of the Space Shuttle Main Engine (SSME). A qualitative physics based model derived from the thermodynamic processes and the flow characteristics underlying the SSME operation was developed to detect and isolate engine failures to the component level. This qualitative model was augmented with empirical models derived from the SSME test-stand data to rapidly detect faults which manifest themselves in engine parameter measurements as deviations from the nominal values. The empirical models integrated with the qualitative model offer the potential for building a complex modeling framework for performing comprehensive engine health monitoring.

Tulpule, S.↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

A Simple and Accurate Energy-Detector-Based Transient Waveform Detection for Smart Grids: Real-World Field Data Performance

Integration of distributed energy sources, advanced meshed operation, sensors, automation, and communication networks all contribute to autonomous operations and decision-making processes utilized in the grid. Therefore, smart grid systems require sophisticated supporting structures. Furthermore, rapid detection and identification of disturbances and transients are a necessary first step towards situationally aware smart grid systems. This way, high-level monitoring is achieved and the entire system kept operational. Even though smart grid systems are unavoidably sophisticated, low-complexity algorithms need to be developed for real-time sensing on the edge and online applications to alert stakeholders in the event of an anomaly. In this study, the simplest form of anomaly detection mechanism in the absence of any a priori knowledge, namely, the energy detector (also known as radiometer in the field of wireless communications and signal processing), is investigated as a triggering mechanism, which may include automated alerts and notifications for grid anomalies. In contrast to the mainstream literature, it does not rely on transform domain tools; therefore, utmost design and implementation simplicity are attained. Performance results of the proposed energy detector algorithm are validated by real power system data obtained from the DOE/EPRI National Database of power system events and the Grid Signature Library.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SMOKE: Characterization of Smoke Particulate for Spacecraft Fire Detection

'Smoke' is a flight definition investigation whose purpose is to characterize the smoke particulate from microgravity smoke sources to enable improved design of future space-craft smoke detectors. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 30 UV-sensing fire detectors. The Space Shuttle Orbiter has nine particle-ionization smoke detectors in the mid-deck and flight deck. The detectors for the US segments of the International Space Station (ISS) are laser-diode, forward-scattering, smoke detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have cooling air-flow. Due to the complete absence of microgravity data, all three of these detector systems were designed based upon 1-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection will grow significantly, necessitating more research into microgravity fire phenomena. In 1997 the Comparative Soot Diagnostics Experiment (CSD) flew in the Orbiter Middeck as a Glovebox payload. The CSD experiment was designed to produce small quantities of smoke from several sources to obtain particulate samples and to determine the response of the ISS and Orbiter smoke detectors to these sources. Marked differences in the performance of the detectors compared to their behavior in 1-g were observed. In extreme cases, the detector used in the orbiter was completely blind to easily visible smoke from sources that were readily detected in 1-g. It is hypothesized but as yet unverified that this performance difference was due to enhanced growth of liquid smoke droplets in low-g. These CSD results clearly demonstrate that spacecraft smoke detector design cannot be based on 1-g experience.

Urban, D. L.↗

Pressure-Sensitive Adhesive Combined with Paper Spray Mass Spectrometry for Low-Cost Collection and Analysis of Drug Residues

Illicit drug use causes over half a million deaths worldwide every year. Drugs of abuse are commonly smuggled through customs and border checkpoints and, increasingly, through parcel delivery services. Improved methods for detection of trace drug residues from surfaces are needed. Such methods should be robust, fieldable, sensitive, and capable of detecting a wide range of drugs. In this work, commercially produced paper with a pressure-sensitive adhesive coating was utilized for the collection and analysis of trace drug residues by paper spray mass spectrometry (MS). This modified substrate was used to combine sample collection of drug residues from surfaces with rapid detection using a single paper spray ticket. The all-in-one ticket was used to probe different surfaces commonly encountered in forensic work including clothing, cardboard, glass, concrete, asphalt, and aluminum. A total of 10 drugs (acetyl fentanyl, fentanyl, clonazolam, cocaine, heroin, ketamine, methamphetamine, methylone, U-47700, and XLR-11) were evaluated and found to be detectable in the picogram range using a benchtop mass spectrometer and in the low nanogram range using a portable ion trap MS. Finally, the novel approach demonstrates a simple yet effective sampling strategy, allowing for rapid identification from difficult surfaces via paper spray mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital holography for real-time non-invasive monitoring of larval fish at power plant intakes

Effective evaluation of technological and operational approaches to reduce entrainment of marine organisms at cooling water intake structures (CWIS) requires accurate organism-sensing systems. Current detection methods lead to large temporal data gaps, require tedious manual analysis, and are fatal to organisms. In this report we describe integrating deep learning with a non-lethal, non-intrusive imaging method—digital holography—to rapidly detect fish larvae. Laboratory experiments demonstrated that the instrument could successfully image fish larvae at flow rates exceeding ranges seen in CWIS. Holograms of two fish larvae species, in the presence of bubbles and detritus, were collected to build a large database for training a lightweight convolutional neural network. The model achieves 97% extraction accuracy in quantifying larvae, and distinguishing them from other particles, including detritus and bubbles, when applied to a dataset of manually classified images, exceeding previous metrics for non-lethal, accurate, and real-time detection. These results demonstrate the potential of in situ holographic imaging for monitoring endangered larval fish species at power plant intake structures, and for high-fidelity, real-time applications in monitoring aquatic ichthyoplankton.

endangered species↗

Lab-on-a-Chip: From Astrobiology to the International Space Station

The continual and long-term habitation of enclosed environments, such as Antarctic stations, nuclear submarines and space stations, raises unique engineering, medical and operational challenges. There is no easy way out and no easy way to get supplies in. This situation elevates the importance of monitoring technology that can rapidly detect events within the habitat that affect crew safety such as fire, release of toxic chemicals and hazardous microorganisms. Traditional methods to monitor microorganisms on the International Space Station (ISS) have consisted of culturing samples for 3-5 days and eventual sample return to Earth. To augment these culture methods with new, rapid molecular techniques, we developed the Lab-on-a-Chip Application Development - Portable Test System (LOCAD-PTS). The system consists of a hand-held spectrophotometer, a series of interchangeable cartridges and a surface sampling/dilution kit that enables crew to collect samples and detect a range of biological molecules, all within 15 minutes. LOCAD-PTS was launched to the ISS aboard Space Shuttle Discovery in December 2006, where it was operated for the first time during March-May 2007. The surfaces of five separate sites in the US Lab and Node 1 of ISS were analyzed for endotoxin, using cartridges that employ the Limulus Amebocyte Lysate (LAL) assay; results of these tests will be presented. LOCAD-PTS will remain permanently onboard ISS with new cartridges scheduled for launch in February and October of 2008 for the detection of fungi (Beta-glucan) and Gram-positive bacteria (lipoteichoic acid), respectively.

Maule, Jake↗

Magnetostrictive materials for enhanced sensors and electronic components

Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions proportional to their magnetization. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications across the DOE and national security mission space, such as monitoring the internal conditions of pipelines, rapidly detecting high-impedance faults in power lines (e.g. trees touching power lines), or enhancing implantable systems for the human body. Dilute doping (<1 at.%) of rare earth elements (REE) has been shown to amplify the magnetostriction. Furthermore, alloy processing by rapid cooling from high temperature tends to result in texturing and therefore greater magnetostriction values, which bodes well for developing advanced manufacturing approaches significantly less expensive than single crystal growth. The goal of this effort was to develop robust, low-cost magnetostrictive materials compatible with advanced manufacturing techniques to exploit the rapid cooling of these approaches while retaining the ability to produce fully dense structures. To be useful as a sensor or actuator the coercivity of the material needs to be minimized so that there is minimal magnetic hysteresis. Employing a small scale laser powder bed fusion (L-PBF) system, specimens of Fe-Ga-Ce were built from alloy powder which had a magnetostriction of 289 ppm along the build direction and 197 ppm perpendicular to the build direction. These values are not far from the 310-350 ppm observed in single crystals of Fe-Ga. The results of the series of samples run suggest this is a very promising route for REE doping to higher levels, especially if the powders can be produced using far from equilibrium approaches such as ultrasonic atomization. The promising results from applying additive manufacturing techniques to these materials, particularly the inexpensive Fe-Al system, has potential for inexpensive high-performing magnetostrictive parts producible at large scales for low-cost sensors.

36 MATERIALS SCIENCE↗

Engineering a new tripartite split-ccGFP system from Corynactis californica for detecting protein–protein interactions

Protein-protein interactions (PPIs) are critical to a range of biological processes and, consequently, aberrant interactions are implicated in many disorders. The study of the complex networks of PPIs promises to elucidate undiscovered roles in cellular processes and the mechanisms of disease. To accomplish this, tools to effectively sense PPIs are necessary. Effective PPI sensors must rapidly detect interactions in real-time with high sensitivity without perturbing the proteins of interest (POIs) under study. Split fluorescent proteins have previously been used to successfully monitor PPIs, in part due to the small size of the tags. Here, we developed an optimized tripartite split GFP system based on Corynactis californica GFP (ccGFP) to detect PPIs in vitro. In this sensor system, ccGFP fragments ccGFP10 and ccGFP11 are tagged to two POIs. PPIs can then be detected via fluorescence by complementation to the third fragment, ccGFP1-9, which reconstitutes functional ccGFP. The optimized ccGFP system shows improved detection kinetics and pH and temperature stability compared to a previous system. We then validated the sensor by monitoring PPIs in two model systems: attractive/repulsive coiled-coils and rapamycin-inducible FRB/FKBP heterodimerization. Finally, we developed an anti-tripartite ccGFP single-chain variable fragment (scFv), which could enable versatile detection of identified protein-protein complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Microbial detection method based on sensing molecular hydrogen

A simple method for detecting bacteria, based on the time of hydrogen evolution, was developed and tested against various members of the Enterobacteriaceae group. The test system consisted of (1) two electrodes, platinum and a reference electrode, (2) a buffer amplifier, and (3) a strip-chart recorder. Hydrogen evolution was measured by an increase in voltage in the negative (cathodic) direction. A linear relationship was established between inoculum size and the time hydrogen was detected (lag period). Lag times ranged from 1 h for 1 million cells/ml to 7 h for 1 cell/ml. For each 10-fold decrease in inoculum, length of the lag period increased 60 to 70 min. Based on the linear relationship between inoculum and lag period, these results indicate the potential application of the hydrogen-sensing method for rapidly detecting coliforms and other gas-producing microorganisms in a variety of clinical, food, and other samples.

Wilkins, J. R.↗

Development of a Real-Time Neutron Noise Analysis System for Fuel Debris Removal at Fukushima Daiichi

The decommissioning of Units 1, 2, and 3 at Fukushima Daiichi presents unique challenges, particularly in mitigating the risk of re-criticality during fuel debris removal. Disturbing previously stable debris configurations has the potential to cause changes in the multiplication of the system, necessitating real-time monitoring to ensure operational safety. Current neutron detection systems, primarily passive, are not optimized for continuous real-time analysis and are limited in their ability to detect rapid changes in system reactivity.

Neutron Detection Systems↗

Clinical 6 MV X-Ray Facility Photo-Neutron/Fission Interrogations with TMFD Sensors

Detection of several targets (U, Be, D2O) of interest to national security has been achieved at Purdue University’s 6 MV (~104 R/h) X-Ray clinical linear accelerator (CLINAC), from photoneutron/fission induced neutron signatures using a Centrifugally Tensioned Metastable Fluid Detector (CTMFD). Traditional neutron detection schemes were saturated and ineffective under the intense (to ~104 R/h) photon environment; however, the CTMFD sensor technology was capable of measuring the relatively insignificant (~10-12x lower intensity) neutron field produced from 6 MeV-end point X-Ray beam interactions with the CLINAC components and surroundings. This is in stark contrast to published results based on conventional belief for immeasurable neutron dose in 6 MV CLINAC facilities. Photoneutron and photofission neutron production rates were detected and analyzed at various standoffs from the isocenter, with and without special nuclear material (SNM) related targets ranging in mass from 5 g of Be, to ~0.6 kg of UO2. It was confirmed that 6 MV X-Ray photons do result in measurable neutron dose above normal cosmic background. Additionally, in threshold mode, the CTMFD operating under a tensioned metastable pressure of -5bar, enabled conclusive rejection of background photoneutrons, while enabling the rapid detection of: Be, D2O, C and U targets within seconds to minutes while operating in and around 104 R/h photon fields.

Ozerov, Stepan↗