Search NASA⌕ Search

SEARCH · Search NASA

Results for “serial sectioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Shock induced multi-mode damage in depleted uranium

Recent dynamic damage studies on depleted uranium samples have revealed mixed mode failure mechanisms leading to incipient cracking as well as ductile failure processes. Results show that delamination of inclusions upon compression may provide nucleation sites for damage initiation in the form of crack tip production. However, under tension the material propagates cracks in a mixed shear localization and mode-I ductile tearing and cracking. Cracks tips appear to link up through regions of severe, shear dominated plastic flow. Shock recovery experiments were conducted on a 50 mm single stage light gas gun. Serial metallographic sectioning was conducted on the recovered samples to characterize the bulk response of the sample. Experiments show delaminated inclusions due to uniaxial compression without damage propagation. Further results show the propagation of the damage through tensile loading to the incipient state, illustrating ductile processes coupled with mixed mode-I tensile ductile tearing, shear localization, and mode-I cracking in depleted uranium.

66↗

Discovering SPP Thermomechanical Pathways

Final report for SPPSi project in Thrust One Friction extrusion is a thermomechanical process that combines conventional extrusion with the action of a rotating die. The plastic deformation of the material being sheared and extruded is the primary source of process heat and it produces strain distributions unlike those resulting from conventional extrusion. This paper proposes an improved strain analysis that evaluates three main strain components in a series of rate-controlled friction extrusions in which the steady state was achieved. Cylindrical AA1100 extrusion billets with two embedded markers were extruded to wire with a 10:1 diametral reduction. The shape change of the embedded markers was determined via serial, transverse sectioning and quantitative metallography of the extruded wires. Three mutually orthogonal strain components (longitudinal, circumferential, and radial) were calculated at different positions along each extruded wire from the marker's shape change. The development of strain from the initial transient to the steady state is discussed. The variation of the steady-state strain with different process parameters is correlated with the die advance per revolution.

42 ENGINEERING↗

Intergranular Oxidation of Unstressed Alloy 600 SA and Alloy 600TT in PWR Primary Water

Unstressed coupons of Alloy 600 SA (solution-annealed) and Alloy 600TT were exposed to simulated pressurized water reactor (PWR) primary water at 360oC. The depth of intergranular oxide penetration, as well as the microstructure and microchemistry associated with intergranular (IG) oxidation of selected samples, were characterized by SEM, serial FIB sectioning, TEM and APT. There is no clear trend to indicate that IG oxidation depths in unstressed coupons are different between Alloy 600 SA and TT. At the same time, all SA+TT materials examined evidenced significant interaction between oxidation and Cr-rich GB precipitates. In addition, the spatial extent of GB compositional changes ahead of the oxidation front (e.g. Cr depletion and Ni enrichment) appears different for Alloy 600 SA vs. SA+TT. In SA heats exposed for only 1000 h (42 days), the composition of some GBs changes over distances of 500–1000 nm. SA+TT materials appear not to develop such long-range GB compositional changes (10s nm alteration distances only).

Alloy 600, IGA, PWR, Oxidation, FIB, TEM, APT↗

An Efficient Algorithm for Mapping Imaging Data to 3D Unstructured Grids in Computational Biomechanics

Geometries for organ scale and multiscale simulations of organ function are now routinely derived from imaging data. However, medical images may also contain spatially heterogeneous information other than geometry that are relevant to such simulations either as initial conditions or in the form of model parameters. In this manuscript, we present an algorithm for the efficient and robust mapping of such data to imaging based unstructured polyhedral grids in parallel. We then illustrate the application of our mapping algorithm to three different mapping problems: 1) the mapping of MRI diffusion tensor data to an unstuctured ventricular grid; 2) the mapping of serial cyro-section histology data to an unstructured mouse brain grid; and 3) the mapping of CT-derived volumetric strain data to an unstructured multiscale lung grid. Execution times and parallel performance are reported for each case.

Einstein, Daniel R.↗

3D Tomography insights on particle-particle bonding in cold spray

The conditions of the target surface during cold spray affect deformation and bonding. While surface preparation can influence the adhesion of the first particles, such modification is not relevant to the particle-particle interfaces that dominate the growth of a coating. Here we study two-particle Cu stacks produced with a single-particle launch apparatus and compare them to single-particle experiments on a clean polished substrate. Serial cross-sectioning using microtomography permits a systematic evaluation and quantification of bonding at the particle-particle interfaces. We observe that the top particle in the two-particle stacks is much more flattened compared to single impacts on the polished substrate. Although the resulting interfacial area expansion is comparable to that of single impacts at the same velocities, bonding at the particle-particle interfaces is significantly less (never exceeding 18% even around the “optimal” velocity for bonding). Lastly, we find that hydrodynamic jetting, a form of localization known to promote adhesion in cold spray, is hindered for impacts on top of a prior particle deposition. Here, the results point to a need for future studies that separately consider topography and mechanical properties of substrates in the pursuit of optimal bonding.

Bonding↗

Design of the beam combination section for stochastic injection

The stochastic injection scenario proposed by D. Neuffer in early 1980’s [1] features the injection and acceptance of pions into the muon storage ring, and is used in the design and simulation of nuSTORM injection and ring [2,3]. The pions decay to muons in the long decay straight section of the ring, then the secondary muons are accepted by the straight FODO structure. The critical design element in this scenario is the Beam Combination Section (BCS), which serially includes a defocusing quadrupole, a bending dipole, and a focusing quadrupole. This paper describes in detail the the design of such a BCS and the matching from this BCS to the downstream side of magnetic horn used to collect the pions after target.

43 PARTICLE ACCELERATORS↗

Status of the Characterization of DEs from the Full Circumference Examination of the Inner Container Closure Weld Region (FY2020)

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. DE containers from FY13 through FY16 were screened with three candidates selected for full circumference evaluation (FCE) according to the ICCWR examination protocol, During the FCE, FY16 DE05 and FY15 DE07 showed suspect major corrosion events, FY16 DE05 Section C2 shows two crack-like features, identified as Denebola and Draco. Both features are located at the boundary of Zone 2 and Zone 3. Consequently, Section C2 of FY16 DE05 was selected for examination by serial metallography at Savannah River National Laboratory (SRNL). For FY15 DE07 the suspect corrosion events were observed on Sections Cl and C2. Section Cl shows one crack-like feature, identified as Acrux. Section C2 shows three crack-like features, identified as Bellatrix, Cursa Minor and Cursa Major. Unlike Acrux and Bellatrix, which are located at the boundary of Zone 2 and Zone 3, Cursa Minor and Cursa Major are located in Zone 2. Sections Cl and C2 of FY15 DE07 were sent to Los Alamos National Laboratory (LANE) for characterization by X-Ray Tomography (XRT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronic damage in S atoms in a native protein crystal induced by an intense X-ray free-electron laser pulse

Current hard X-ray free-electron laser (XFEL) sources can deliver doses to biological macromolecules well exceeding 1 GGy, in timescales of a few tens of femtoseconds. During the pulse, photoionization can reach the point of saturation in which certain atomic species in the sample lose most of their electrons. This electronic radiation damage causes the atomic scattering factors to change, affecting, in particular, the heavy atoms, due to their higher photoabsorption cross sections. Here, it is shown that experimental serial femtosecond crystallography data collected with an extremely bright XFEL source exhibit a reduction of the effective scattering power of the sulfur atoms in a native protein. Quantitative methods are developed to retrieve information on the effective ionization of the damaged atomic species from experimental data, and the implications of utilizing new phasing methods which can take advantage of this localized radiation damage are discussed.

Galli, L.↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

Implementation of a level 1 trigger system using high speed serial (VXS) techniques for the 12GeV high luminosity experimental programs at Thomas Jefferson National Accelerator Facility

We will demonstrate a hardware and firmware solution for a complete fully pipelined multi-crate trigger system that takes advantage of the elegant high speed VXS serial extensions for VME. This trigger system includes three sections starting with the front end crate trigger processor (CTP), a global Sub-System Processor (SSP) and a Trigger Supervisor that manages the timing, synchronization and front end event readout. Within a front end crate, trigger information is gathered from each 16 Channel, 12 bit Flash ADC module at 4 nS intervals via the VXS backplane, to a Crate Trigger Processor (CTP). Each Crate Trigger Processor receives these 500 MB/S VXS links from the 16 FADC-250 modules, aligns skewed data inherent of Aurora protocol, and performs real time crate level trigger algorithms. The algorithm results are encoded using a Reed-Solomon technique and transmission of this Level 1 trigger data is sent to the SSP using a multi-fiber link. The multi-fiber link achieves an aggregate trigger data transfer rate to the global trigger at 8 Gb/s. The SSP receives and decodes Reed-Solomon error correcting transmission from each crate, aligns the data, and performs the global level trigger algorithms. The entire trigger system is synchronous and operates at 250 MHz with the Trigger Supervisor managing not only the front end event readout, but also the distribution of the critical timing clocks, synchronization signals, and the global trigger signals to each front end readout crate. These signals are distributed to the front end crates on a separate fiber link and each crate is synchronized using a unique encoding scheme to guarantee that each front end crate is synchronous with a fixed latency, independent of the distance between each crate. The overall trigger signal latency is <3 uS, and the proposed 12GeV experiments at Jefferson Lab require up to 200KHz Level 1 trigger rate.

43 PARTICLE ACCELERATORS↗

Synchrotron infrared imaging of advanced glycation endproducts (AGEs) in cardiac tissue from mice fed high glycemic diets

Recent research findings correlate an increased risk for dieases such as diabetes, macular degeneration and cardiovascular disease (CVD) with diets that rapidly raise the blood sugar levels; these diets are known as high glycemic index (GI) diets which include white breads, sodas and sweet deserts. Lower glycemia diets are usually rich in fruits, non-starchy vegetables and whole grain products. The goal of our study was to compare and contrast the effects of a low vs. high glycemic diet using the biochemical composition and microstructure of the heart. The improved spatial resolution and signal-to-noise for SR-FTIR obtained through the coupling of the bright synchrotron infrared photon source to an infrared spectral microscope enabled the molecular-level observation of diet-related changes within unfixed fresh frozen histologic sections of mouse cardiac tissue. High and low glycemic index (GI) diets were started at the age of five-months and continued for one year, with the diets only differing in their starch distribution (high GI diet = 100% amylopectin versus low GI diet = 30% amylopectin/70% amylose). Serial cryosections of cardiac tissue for SR-FTIR imaging alternated with adjacent hematoxylin and eosin (H&E) stained sections allowed not only fine-scale chemical analyses of glycogen and glycolipid accumulation along a vein as well as protein glycation hotspots co-localizing with collagen cold spots but also the tracking of morphological differences occurring in tandem with these chemical changes. As a result of the bright synchrotron infrared photon source coupling, we were able to provide significant molecular evidence for a positive correlation between protein glycation and collagen degradation in our mouse model. Our results bring a new insight not only to the effects of longterm GI dietary practices of the public but also to the molecular and chemical foundation behind the cardiovascular disease pathogenesis commonly seen in diabetic patients.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative order-parameter measurement in lattice-mismatched AlInP using precession electron diffraction

Precession electron diffraction (PED) was used to measure the long-range order parameter in lattice-mismatched AlInP epitaxial films under investigation for solid-state-lighting applications. Both double- and single-variant films grown at 620, 650, and 680°C were analyzed in TEM cross-section. PED patterns were acquired in selected-area-diffraction mode through external microscope control using serial acquisition, which allows inline image processing. The integrated peak intensities from experimental patterns were fit using dynamical simulations of diffraction from the ordered domain structures. Included in the structure-factor calculations were mean atomic displacements of the anions (P) due to ordering, which were found by valence-force-field calculations to have a nearly linear dependence on order parameter. A maximum order parameter of S = 0.36 was measured for a double-variant specimen grown at 650°C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-F-T-104: Determining the NTCP Parameters of Pharyngeal Constrictors and Proximal Esophagus for Radiation Induced Swallowing Problems Recorded Six Months After Radiation Therapy for Head and Neck Tumors

Purpose: To estimate the radiobiological parameters of four NTCP models that describe the dose-response relations of pharyngeal constrictors and proximal esophagus regarding the severity of patient reported swallowing problems 6 months post chemo-radiotherapy. To identify the section/structure that best correlates with the manifestation of the clinical endpoints. Finally, to compare the goodness-of-fit of those models. Methods: Forty-three patients were treated on a prospective multi-institutional phase II study for oropharyngeal squamous cell carcinoma. All the patients received 60 Gy IMRT and they reported symptoms using the novel patient reported outcome version of the CTCAE. We derived the individual patient dosimetric data of superior, medium and inferior sections of pharyngeal constrictors (SPC, MPC and IPC), superior and inferior sections of esophagus (SES and IES) as separate structures as well as combinations. The Lyman-Kutcher-Burman (LKB), Relative Seriality (RS), Logit and Relative Logit (RL) NTCP models were used to fit the patient data. The fitting of the different models was assessed through the area under the receiver operating characteristic curve (AUC) and the Odds Ratio methods. Results: The AUC values were highest for the SPC for Grade ≥ 2 (0.719 for the RS and RL models, and 0.716 for LKB and Logit). For Grade ≥ 1, the respective values were 0.699 for RS, LKB and Logit and 0.676 for RL. For MPC the AUC values varied between 0.463–0.477, for IPC between 0.396–0.458, for SES between 0.556–0.613 and for IES between 0.410–0.519. The Odds Ratio for the SPC was 15.6 (1.7–146.4) for RS, LKB and Logit for NTCP of 55%. Conclusion: All the examined NTCP models could fit the clinical data with similar accuracy. The SPC appear to correlate best with the clinical endpoints of swallowing problems. A prospective study could establish the use of NTCP values of SPC as a constraint in treatment planning.

60 APPLIED LIFE SCIENCES↗

A six degrees of freedom femtosecond laser system for fabrication of small-scale mechanical property specimens

Here, we present the details of a novel ultra-short pulsed laser machining workstation that has been employed for high-throughput laser machining of small-scale mechanical property specimens. This system employs a six degrees of freedom hexapod positioning stage capable of macroscopic movements at high positional accuracy. We developed a methodology that uses quantitative image analysis to measure key parameters required to minimize the hexapod positioning and rotational error. Application of this system to laser machining of small-scale 316L stainless steel tensile specimens and ultra-high molecular weight polyethylene compressive specimens using eucentric tilt and rotation about the specimen axis will be shown, where serial laser milling at a specimen tilt angle of 10° was used to effectively eliminate any taper in the sample cross section that is typically found in laser machining.

47 OTHER INSTRUMENTATION↗

Femtosecond response of polyatomic molecules to ultra-intense hard X-rays

We report x-ray free-electron lasers enable the investigation of the structure and dynamics of diverse systems, including atoms, molecules, nanocrystals and single bioparticles, under extreme conditions. Many imaging applications that target biological systems and complex materials use hard X-ray pulses with extremely high peak intensities (exceeding 10 20 watts per square centimetre). However, fundamental investigations have focused mainly on the individual response of atoms and small molecules using soft X-rays with much lower intensities. Studies with intense X-ray pulses have shown that irradiated atoms reach a very high degree of ionization, owing to multiphoton absorption, which in a heteronuclear molecular system occurs predominantly locally on a heavy atom (provided that the absorption cross-section of the heavy atom is considerably larger than those of its neighbours) and is followed by efficient redistribution of the induced charge. In serial femtosecond crystallography of biological objects—an application of X-ray free-electron lasers that greatly enhances our ability to determine protein structure—the ionization of heavy atoms increases the local radiation damage that is seen in the diffraction patterns of these objects and has been suggested as a way of phasing the diffraction data. On the basis of experiments using either soft or less-intense hard X-rays, it is thought that the induced charge and associated radiation damage of atoms in polyatomic molecules can be inferred from the charge that is induced in an isolated atom under otherwise comparable irradiation conditions. Here we show that the femtosecond response of small polyatomic molecules that contain one heavy atom to ultra-intense (with intensities approaching 10 20 watts per square centimetre), hard (with photon energies of 8.3 kiloelectronvolts) X-ray pulses is qualitatively different: our experimental and modelling results establish that, under these conditions, the ionization of a molecule is considerably enhanced compared to that of an individual heavy atom with the same absorption cross-section. This enhancement is driven by ultrafast charge transfer within the molecule, which refills the core holes that are created in the heavy atom, providing further targets for inner-shell ionization and resulting in the emission of more than 50 electrons during the X-ray pulse. Fnally, our results demonstrate that efficient modelling of X-ray-driven processes in complex systems at ultrahigh intensities is feasible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hexagonal Geometries in MPACT

The MPACT code is a high-fidelity light-water reactor analysis code using whole-core pin-resolved neutron transport calculations on modern parallel-computing hardware. MPACT uses the 2D/1D method to solve 3D neutron transport problems by decomposing the problem into a stack of 2D slices, each of which is solved independently using the method of characteristics (MOC). The slices are then coupled axially using the P3 nodal expansion method (NEM-P3) for the 1D axial calculations. MPACT also employs the coarse mesh finite difference (CMFD) method to accelerate calculations. This manuscript details work supporting advanced reactor designs using hexagonal pins and hexagonal assemblies such as the VVER-1000. If performed correctly, MOC is geometry agnostic. However, MPACT previously had optimizations in place for Cartesian geometries, specifically in the modularization and current calculations. Sections 2 and 3 detail the changes made to MPACT to support MOC and CMFD calculations on hexagonal geometries. Section 4 reports results demonstrating solution consistency for problems run with and without CMFD acceleration, results demonstrating solution consistency when run in serial and parallel, and pincell results using the Monte Carlo code, McCard’s benchmark results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-94: Plan2pdf - a Software Tool for Automatic Plan Report for Philips Pinnacle TPS

Purpose: To implement an automatic electronic PDF plan reporting tool for Philips Pinnacle treatment planning system (TPS) Methods: An electronic treatment plan reporting software is developed by us to enable fully automatic PDF report from Pinnacle TPS to external EMR programs such as MOSAIQ. The tool is named “plan2pdf”. plan2pdf is implemented using Pinnacle scripts, Java and UNIX shell scripts, without any external program needed. plan2pdf supports full auto-mode and manual mode reporting. In full auto-mode, with a single mouse click, plan2pdf will generate a detailed Pinnacle plan report in PDF format, which includes customizable cover page, Pinnacle plan summary, orthogonal views through each plan POI and maximum dose point, DRR for each beam, serial transverse views captured throughout the dose grid at a user specified interval, DVH and scorecard windows. The final PDF report is also automatically bookmarked for each section above for convenient plan review. The final PDF report can either be saved on a user specified folder on Pinnacle, or it can be automatically exported to an EMR import folder via a user configured FTP service. In manual capture mode, plan2pdf allows users to capture any Pinnacle plan by full screen, individual window or rectangular ROI drawn on screen. Furthermore, to avoid possible patients’ plan mix-up during auto-mode reporting, a user conflict check feature is included in plan2pdf: it prompts user to wait if another patient is being exported by plan2pdf by another user. Results: plan2pdf is tested extensively and successfully at our institution consists of 5 centers, 15 dosimetrists and 10 physicists, running Pinnacle version 9.10 on Enterprise servers. Conclusion: plan2pdf provides a highly efficient, user friendly and clinical proven platform for all Philips Pinnacle users, to generate a detailed plan report in PDF format for external EMR systems.

60 APPLIED LIFE SCIENCES↗