Search NASA⌕ Search

SEARCH · Search NASA

Results for “shaker test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Coupled Facility-Payload Vibration Modeling Improvements

A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at National Aeronautics and Space Administration/Goddard Space Flight Center an analysis is performed to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combined dynamics of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA/Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.

Finite Element Analysis↗

State-space formulation of multi-shaker modal analysis

As modal testing techniques have improved in recent years, the demands placed on the accuracy of modal test results have increased. This paper describes a new multi-input, multi-output modal parameter estimation algorithm suitable for the identification of reduced-order models of structures. The method described is a frequency-domain method based on excitation and response spectra. The principal features of the algorithm are: (1) applicability to general linear, time-invariant systems, (2) direct use of multiple input and multiple response data, (3) identification of reduced-order models with minimum user interaction through the use of two automatic model-reduction techniques, (4) identification of a consistent set of modal parameters through the use of numerically stable least-squares techniques, and (5) complete user documentation.

Craig, Roy R., Jr.↗

NASA Critical Facilities Maintenance Assessment

Critical Facilities Maintenance Assessment (CFMA) was first implemented by NASA following the March 2000 overtest of the High Energy Solar Spectroscopic Imager (HESSI) spacecraft. A sine burst dynamic test using a 40 year old shaker failed. Mechanical binding/slippage of the slip table imparted 10 times the planned force to the test article. There was major structural damage to HESSI. The mechanical "health" of the shaker had not been assessed and tracked to assure the test equipment was in good working order. Similar incidents have occurred at NASA facilities due to inadequate maintenance (e.g., rainwater from a leaky roof contaminated an assembly facility that housed a spacecraft). The HESSI incident alerted NASA to the urgent need to identify inadequacies in ground facility readiness and maintenance practices. The consequences of failures of ground facilities that service these NASA systems are severe due to the high unit value of NASA products.

maintenance↗

Matching Vibration Testing to "Real-World" Conditions

Vibration spectrum of test machine adjusted to that observed in operation. Test specimen placed in test fixture and attached to shaker. Shaker initially operated at one-quarter full level of input spectrum to prevent overloading. Short vibration test run, and specimen response compared to control spectrum. Imput spectrum then adjusted until response resembles control spectrum.

Olsen, Albert D., Jr.↗

Benefits of Force Limiting Vibration Testing

Force limited random vibration testing is used at NASA John Glenn Research Center (formerly NASA Lewis Research Center) for qualifying aerospace hardware for flight. The benefit of force limiting testing is that it limits overtesting of flight hardware, by controlling input force and acceleration from the shaker (dual control) to the test article. The purpose of force limiting is to replicate the test article resonant response for the actual flight mounting condition. The force limiting testing technology has been implemented at the Jet Propulsion Laboratory for the past 10 years on various spacecraft testing programs. The Cassini mission to Saturn, most notably, utilized force limiting vibration testing as part of the spacecraft system level vibration testing. NASA John Glenn Research Center is responsible for microgravity combustion and fluid science research on the Shuttle and the International Space Station. Qualification testing of delicate and vibration sensitive science instrumentation is particularly challenging to successfully qualify for flight. In order to facilitate the testing process, force limiting has been implemented to minimize overtesting of flight hardware. This paper will address recent flight camera testing (qualification random vibration and strength testing) for the Combustion Module-2 mission and the impact of Semi-empirical Method force limits.

McNelis, Mark E.↗

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management↗

Tank 48H Phase 1 Initial Testing Using Sodium Permanganate to Decompose Tetraphenylborate: Simulant Studies with Shaker Oven and 2-L Vessel

Tank 48H currently holds legacy material including organic tetraphenylborate (TPB) compounds from the operation of the In-Tank Precipitation process. The large quantity of TPB is not compatible with the waste treatment facilities at SRS and must be removed or undergo treatment to oxidize the organic compounds before the tank can be returned to routine Tank Farm service. Tank 48H currently holds approximately 270,000 gallons of legacy material comprised of decontaminated salt solution, approximately 20,000 kilograms of TPB solids, 3,400 kilograms of sludge solids, and 1,800 kilograms of monosodium titanate (MST).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mossbauer vibration calibration systems evaluated

Mossbauer effect vibration calibrator measures the velocity of high frequency, low amplitude vibration at various velocity and frequency ranges. It contains a highly precise calibrations standard unit and a vibration measuring system and may be applied to ultrafine testing and calibrating prezoelectric shakers, and vibration transducers.

Hobbs, J. V.↗

An experimental study of propeller-induced structural vibration and interior noise

This paper presents results of tests conducted to study fuselage sidewall dynamics and their effects on the cabin interior noise of a twin-engine, propeller-driven, light aircraft. Data on the dynamic behavior were obtained by slowly sweeping the RPM of one of the engines while the aircraft was stationary on the ground. This technique allowed frequency response plots of the sidewall structural accelerations to be obtained. These accelerations are compared to similar results from a test using a mechanical shaker in order to evaluate the structural dynamic response caused by the harmonics of the propeller blade passage tone. The dynamic response of the fuselage sidewall is also discussed as a noise transmission mechanism. A second mechanism for noise transmission through the fuselage sidewall was investigated by opening the copilot's window. The results illustrate the complex nature of the noise transmission mechanisms and the importance of correctly assessing noise paths.

Howlett, J. T.↗

Ares I-X Launch Vehicle Modal Test Measurements and Data Quality Assessments

The Ares I-X modal test program consisted of three modal tests conducted at the Vehicle Assembly Building at NASA s Kennedy Space Center. The first test was performed on the 71-foot 53,000-pound top segment of the Ares I-X launch vehicle known as Super Stack 5 and the second test was performed on the 66-foot 146,000- pound middle segment known as Super Stack 1. For these tests, two 250 lb-peak electro-dynamic shakers were used to excite bending and shell modes with the test articles resting on the floor. The third modal test was performed on the 327-foot 1,800,000-pound Ares I-X launch vehicle mounted to the Mobile Launcher Platform. The excitation for this test consisted of four 1000+ lb-peak hydraulic shakers arranged to excite the vehicle s cantilevered bending modes. Because the frequencies of interest for these modal tests ranged from 0.02 to 30 Hz, high sensitivity capacitive accelerometers were used. Excitation techniques included impact, burst random, pure random, and force controlled sine sweep. This paper provides the test details for the companion papers covering the Ares I-X finite element model calibration process. Topics to be discussed include test setups, procedures, measurements, data quality assessments, and consistency of modal parameter estimates.

Templeton, Justin D.↗

The design concept of the 6-degree-of-freedom hydraulic shaker at ESTEC

The European Space Agency (ESA) has decided to extend its test facilities at the European Space and Technology Center (ESTEC) at Noordwijk, The Netherlands, by implementing a 6-degree-of-freedom hydraulic shaker. This shaker will permit vibration testing of large payloads in the frequency range from 0.1 Hz to 100 Hz. Conventional single axis sine and random vibration modes can be applied without the need for a configuration change of the test set-up for vertical and lateral excitations. Transients occurring during launch and/or landing of space vehicles can be accurately simulated in 6-degrees-of-freedom. The performance requirements of the shaker are outlined and the results of the various trade-offs, which are investigated during the initial phase of the design and engineering program are provided. Finally, the resulting baseline concept and the anticipated implementation plan of the new test facility are presented.

Brinkman, P. W.↗

Microcircuit-cleaning machine

Circuit shaker removes loose particles from hybrid microcircuit packages. Machine can reduce rejections from particle impact noise determination (PIND) tests to less than 7 percent. Shaker is easily constructed and could be manufactured for distribution as kit.

Robinson, W. W.↗

Binaural Simulation Experiments in the NASA Langley Structural Acoustics Loads and Transmission Facility

A location and positioning system was developed and implemented in the anechoic chamber of the Structural Acoustics Loads and Transmission (SALT) facility to accurately determine the coordinates of points in three-dimensional space. Transfer functions were measured between a shaker source at two different panel locations and the vibrational response distributed over the panel surface using a scanning laser vibrometer. The binaural simulation test matrix included test runs for several locations of the measuring microphones, various attitudes of the mannequin, two locations of the shaker excitation and three different shaker inputs including pulse, broadband random, and pseudo-random. Transfer functions, auto spectra, and coherence functions were acquired for the pseudo-random excitation. Time histories were acquired for the pulse and broadband random input to the shaker. The tests were repeated with a reflective surface installed. Binary data files were converted to universal format and archived on compact disk.

Grosveld, Ferdinand W.↗

The Effect of Drive Signal Limiting on High Cycle Fatigue Life Analysis

It is common practice to assume a Gaussian distribution of both the input acceleration and the response when modeling random vibration tests. In the laboratory, however, shaker controllers often limit the drive signal to prevent high amplitude peaks. The high amplitudes may either be truncated at a given level (socalled brick wall limiting or abrupt clipping), or compressed (soft limiting), resulting in drive signals which are no longer Gaussian. The paper first introduces several methods for limiting a drive signal, including brick wall limiting and compression. The limited signal is then passed through a linear time-invariant system representing a device under test. High cycle fatigue life predictions are subsequently made using spectral fatigue and rainflow cycle counting schemes. The life predictions are compared with those obtained from unclipped input signals. Some guidelines are provided to help the test engineer decide how clipping should be applied under different test scenarios.

Kihm, Frederic↗

Ground Vibration Test Planning and Pre-Test Analysis for the X-33 Vehicle

This paper describes the results of the modal test planning and the pre-test analysis for the X-33 vehicle. The pre-test analysis included the selection of the target modes, selection of the sensor and shaker locations and the development of an accurate Test Analysis Model (TAM). For target mode selection, four techniques were considered, one based on the Modal Cost technique, one based on Balanced Singular Value technique, a technique known as the Root Sum Squared (RSS) method, and a Modal Kinetic Energy (MKE) approach. For selecting sensor locations, four techniques were also considered; one based on the Weighted Average Kinetic Energy (WAKE), one based on Guyan Reduction (GR), one emphasizing engineering judgment, and one based on an optimum sensor selection technique using Genetic Algorithm (GA) search technique combined with a criteria based on Hankel Singular Values (HSV's). For selecting shaker locations, four techniques were also considered; one based on the Weighted Average Driving Point Residue (WADPR), one based on engineering judgment and accessibility considerations, a frequency response method, and an optimum shaker location selection based on a GA search technique combined with a criteria based on HSV's. To evaluate the effectiveness of the proposed sensor and shaker locations for exciting the target modes, extensive numerical simulations were performed. Multivariate Mode Indicator Function (MMIF) was used to evaluate the effectiveness of each sensor & shaker set with respect to modal parameter identification. Several TAM reduction techniques were considered including, Guyan, IRS, Modal, and Hybrid. Based on a pre-test cross-orthogonality checks using various reduction techniques, a Hybrid TAM reduction technique was selected and was used for all three vehicle fuel level configurations.

Bedrossian, Herand↗