Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Oscillator-Qubit Quantum Processors: Instruction Set Architectures, Abstract Machine Models, and Applications

This tutorial offers a pedagogical guide to hybrid quantum processors that integrate discrete-variable (DV) qubits and continuous-variable (CV) oscillators. Aimed at computer scientists, engineers, and physicists, it provides an overview of the experimental, algorithmic, and architectural aspects of this novel and rapidly developing hardware model. Experimental realizations of this model include superconducting, trapped-ion, and neutral-atom platforms. By combining DV and CV components, hybrid oscillator-qubit processors enable a powerful new paradigm that offers complementary strengths for quantum control, error correction, computation, and simulation. Working toward the goal of a full-stack system connecting applications to CV-DV hardware, we define and formulate abstract machine models and instruction set architectures. These essential abstractions enable codesign of hardware and software, and resource estimation for exploring the potential of current and future hardware for computational and simulation tasks. Using these abstractions, we present both new and existing examples that illustrate the benefits of hybrid CV-DV processors relative to traditional DV-only hardware in computation as well as quantum simulation of physical models. Examples include algorithms for transferring states between DV and CV systems, performing the quantum Fourier transform, and simulation of lattice gauge theories. Relative to qubit-only hardware, the bosonic degrees of freedom natively available in hybrid architectures can substantially reduce the circuit complexity of simulations for physical models containing bosons. A key technique is the extension of quantum signal processing ideas to CV-DV systems. This work is intended to serve as a timely and comprehensive guide to this relatively unexplored yet promising approach to quantum computation and to provide a road map to guide future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and analysis of magnetic coil for relativistic magnetron

This paper presents the design of magnetic coil for relativistic magnetron (RM) for LIA (Linear Induction Accelerator)-400 systems. Vacuum improves the efficiency of RM for HPM generation. Magnetic field in RM is very critical parameter and should be nearly constant in the active region. Typical coils are helical in nature, which have multi turns of varying radius. Magnetic field calculation of such coils with basic equations of Helmholtz coils or solenoid with mean radius can only give estimation. Field computational softwares like CST require small mesh size and boundary at very far so consume large memory and take very much time. Helical coils are simplified such that the basic law of magnetic field calculation i.e. Bio-Savart law can be applied with less complexity. Pairs of spiral coils have been analyzed for magnetic field and Lorenz's force. The approach is field experimentally validated. (author)

43 PARTICLE ACCELERATORS↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

60 APPLIED LIFE SCIENCES↗

scANN

SAND2025-00656O scANN, also known as sampling by coinflips artificial neural networks, is a software tool that estimates uncertainty in artificial intelligence by performing Monte Carlo analysis on the weight matrices of feedforward neural networks. This computationally intensive process aims to explore the potential value added by future probabilistic hardware. The program’s output helps researchers gain insights into how probabilistic neural networks work. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

A Computer Design Tool for Ceramic Receivers

Gen3 solar receivers and other components will experience a combination of high temperatures and high stress caused by thermal stress and internal pressure. Under these conditions metallic components, even those manufactured from nickel-based superalloys, have poor reliability. Engineering ceramics could be a solution, as these materials have excellent high temperature strength. However, accurately assessing the reliability of a ceramic component operating in these conditions requires an entirely different approach compared to metallic materials. This paper describes the implementation of statistical models for evaluating the reliability of high temperature ceramic components in srlife – an open-source software package for estimating the life of high temperature concentrating solar power equipment. This new capability allows users to make fair comparisons between competing metallic and ceramic component designs and to accurately assess the plant efficiency and economics of ceramic solar receivers and other components.

Messner, Mark (ORCID:0000000200404385)↗

Time-Dependent Failure Assessment of Ceramic Receivers

The outlet temperature targets for Gen 3 Concentrating Solar Power (CSP) systems pose a significant challenge to the structural reliability of high temperature metallic components, including those manufactured from nickel-based superalloys. Advanced ceramics present a potential solution due to their excellent high-temperature strength. However, accurate assessment of ceramic components requires an entirely different approach compared to metallic components. This paper describes the implementation of time-dependent reliability analysis of ceramic components in srlife – an open-source software package for estimating the life of high temperature CSP components. This new capability will allow high temperature CSP designers to make fair comparisons between competing metallic and ceramic designs and accurately assess the performance of different ceramic materials for CSP receivers and other components. The current version of the tool is available at https://github.com/Argonne-National-Laboratory/srlife.

Barua, Bipul (ORCID:0000000247184113)↗

Comparison of Thermal Diffusivity Degradation of Irradiated Zirlo and SiC-SiC Composite

Zirlo (Zircaloy cladding material from Westinghouse) has been widely used as the fuel cladding material in Light Water Reactors because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. But as Zirlo reacts with water at high temperature, which can trigger serious accidents, efforts have been made to explore better candidates to replace Zirlo in the water-cooled reactors. SiC-SiC composite is considered as one of the most viable options due to its comparable mechanical performances and corrosion resistance. However, one of the most important properties, thermal diffusivities of both Zirlo and SiC-SiC composite, and their degradation after irradiation, are not well known yet. Ion-irradiated samples are used to study the thermal property degradation caused by irradiation instead of the neutron-irradiated ones due to the significantly lower radioactivity. The microstructural damage is estimated from the software simulation SRIM/TRIM based on the energy and fluence of the ion, and the target material, and represented by DPA (displacement by atom). Different from neutron-irradiated samples, the damaged layer of ion-irradiated samples is only a few to a few tens of micrometers thick, and the damage is depth dependent. It is impossible to directly measure the bulk property change, and a microscale measurement technique is necessary. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag of the thermal wave, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, thermal diffusivity of the light damage layer of the post-irradiation Zirlo and SiC-SiC composite are measured and compared. The Zirlo sample is irradiated by Ni{sup 9+} ion, and SiC-SiC composite material is irradiated by Si{sup 7+} ion. The peak DPA of both sample is similar as ∼10. For ion-irradiated materials, DPA is known to increase with depth before it reaches the peak, and then sharply drop to zero. In term of light damage layer in this manuscript, we mean by the layer with a DPA smaller than 5% maximum value. In this layer DPA increases slowly and smoothly with depth, and the structure and thus thermal properties are more spatially uniform. For the SiC-SiC composite, the measurements are separately conducted on fibers along radial or axial direction, and on the matrix. Our measurement results show that with similar microstructural damage, thermal diffusivity of matrix SiC reduces more significantly than that of Zirlo. For fiber SiC that has a much lower thermal diffusivity than the matrix SiC before irradiation, the post-irradiation effect on thermal diffusivity is not obvious.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Battery State of Health Estimator: Cooperative Research and Development Final Report

NREL has developed a software tool to enable Renewance to estimate the degradation of batteries from basic information such as the type of battery and the application of that battery during its first life, so that used batteries may be evaluated for potential repurposing at low cost. This software tool utilizes NREL's BLAST-Lite battery degradation modeling code, which was updated with additional models for commercially produced lithium-ion batteries as a part of this CRADA. The software tool enables users to input details such as battery type and application so that lifetime estimates can be made without any programming or expert battery knowledge. The application input loads in saved values for parameters such as cycles per year, depth-of-discharge, and other battery operating parameters from a file defined by Renewance. These parameters may be modified to refine simulations for specific batteries. The software tool also incorporates a degradation model optimization tool, whereby existing battery degradation models may be tuned according to measured battery health. This ensures that new models still predict degradation behaviors expected from a certain battery chemistry, but with the overall degradation rate tuned to a specific battery make and model. The new model can then be saved for estimating the degradation of other similar batteries. An additional task was planned to utilize machine-learning to enable battery health diagnosis from rapid EIS measurements to accelerate the screening of used batteries. This task was not completed due to lack of available data for training a machine-learning model. CRADA benefit to DOE, Participant, and US Taxpayer: Further development of open-source software tool BLAST-Lite for predicting the lifetime of commercially produced Lithium-ion batteries (NREL SWR-22-69).

25 ENERGY STORAGE↗

AWE-ML: Averaged Weights for Explainable Machine Learning v. 1.0

This software uses averaged weighted estimators to classify instances and then explicate the individual decision process in classification. The software has state of the art performance in accuracy, while maintaining full explainability. It does this by calculating hierarchically averaged probabilities for a large class of feature combinations and updating them ‘on-the-fly’. On the fly updating also allows the model to be accurate, relative to the total dataset, maintaining accuracy in real-time, without a need to retrain the classifier.

Agarwal, Sapan↗

CheKiPEUQ

Parameter estimation for complex physical problems often suffers from finding 'solutions' that are not physically realistic. The CheKiPEUQ software provides tools for finding physically realistic parameter estimates.and CheKiPEUQ provide tools for making graphs of the parameter positions within parameter space as well as plots of the final simulation results. The primary purpose of the CheKiPEUQ software is to enable more physically realistic parameter estimation from comparing simulations to experiments. Specifically, when prior knowledge is available about the region of parameter space which is physically realistic and when the level of uncertainty from experiment can be estimated. The software is intentionally general and can be used for almost any type of simulation. The software is made in a user friendly manner so that users can simply enter the required data and then run the program, following guidelines provided by the authors along with some trial and error. Examples are provided. Users do not need to understand the methodology that will be namedi in the following sentences. While CheKiPEUQ can be used for conventional parameter estimation and other uses, the primary uses for CheKiPEUQ are: 1) Bayesian Parameter Estimation, 2) Bayesian Model Discrimination, 3) Bayesian Design of Experiments. For more information see the project website, documentation, examples, and related publications.

Savara, Aditya [Oak Ridge National Lab. (ORNL), Oa↗

Quantifying uncertainty in Pareto estimates of global lake area

This software contains the code for Bayesian uncertainty analysis of global lake area. Computed uncertainties are compared against more conventional estimation using lake size-abundance distributions. Routines are included to explore sensitivity to observational errors and ad-hoc "censoring" strategies.

Stachelek, Jemma↗

Hierarchical Estimation For Planetary Protection

The software uses Bayes' theorem to describe the probability of an event based on prior knowledge of conditions that might be related to the event. The purpose of Bayesian analysis is to determine posterior probabilities based on prior probabilities where new information can be used in the decision-making process as additional data is gathered. The software will be used in Probabilistic Risk Assessments (PRAs) related to the Europa Clipper mission, which is one of NASA’s top priorities. Ultimately, the mission entails sending the Europa Clipper spacecraft to Jupiter’s Europa moon to orbit the planet and collect data for research and development. Europa is the smallest of the four Galilean moons orbiting Jupiter and is believed by researchers to be the most promising place to look for present-day environments suitable for life. Europa is thought to have an iron core, a rocky mantle, and a salt-water ocean covered by an ice-layered surface.

Gribok, Andrei [Idaho National Laboratory (INL), I↗

Preliminary Routing for a National Laboratory Lab-Wide Commuting Program

There is a growing interest in reducing the amount of vehicle miles traveled (VMT), both in public and private sector organizations, in an effort to reduce overall carbon emissions. The Oak Ridge National Laboratory (ORNL), located in Oak Ridge, Tennessee, and located within close proximity to Knoxville, Tennessee, has more than 4,500 employees, most of which live in and around Knoxville. ORNL is currently developing a pilot commuting program for all employees, which incorporates the use of park-and-ride facilities. This study outlines the methodology behind the preliminary geoanalysis and routing used in developing a lab-wide commuting program. Due to privacy concerns, the data used for the study included numbers of employee residences per zip code rather than actual residential addresses. Commuting configurations by clustered zip code area and vehicle type were developed based on number of residences in a limited area, and the desire to minimize VMT. Central locations were selected using ArcGIS software. Satellite imagery was used to locate actual, suitable parking facilities to accommodate the specified number of residents involved in each commuting configuration. Optimized routing, and estimations of travel times, were performed using TransCAD GIS software. Energy estimates in kilowatt-hours (kwh) and gallons of gasoline, and gallons of gasoline equivalent, were all determined based on the scenarios. Standard petroleum-fueled vehicles were used in the initial estimates. Standard electric vehicles were also used in alternative scenarios to estimate potential additional energy and fuel savings. Furthermore the initial findings from this work will be used to develop a pilot program for ORNL.

99 GENERAL AND MISCELLANEOUS↗

SU-E-I-25: Determining Tube Current, Tube Voltage and Pitch Suitable for Low- Dose Lung Screening CT

Purpose: The quality of a computed tomography (CT) image and the dose delivered during its acquisition depend upon the acquisition parameters used. Tube current, tube voltage, and pitch are acquisition parameters that potentially affect image quality and dose. This study investigated physicians' abilities to characterize small, solid nodules in low-dose CT images for combinations of current, voltage and pitch, for three CT scanner models. Methods: Lung CT images was acquired of a Data Spectrum anthropomorphic torso phantom with various combinations of pitch, tube current, and tube voltage; this phantom was used because acrylic beads of various sizes could be placed within the lung compartments to simulate nodules. The phantom was imaged on two 16-slice scanners and a 64-slice scanner. The acquisition parameters spanned a range of estimated CTDI levels; the CTDI estimates from the acquisition software were verified by measurement. Several experienced radiologists viewed the phantom lung CT images and noted nodule location, size and shape, as well as the acceptability of overall image quality. Results: Image quality for assessment of nodules was deemed unsatisfactory for all scanners at 80 kV (any tube current) and at 35 mA (any tube voltage). Tube current of 50 mA or more at 120 kV resulted in similar assessments from all three scanners. Physician-measured sphere diameters were closer to actual diameters for larger spheres, higher tube current, and higher kV. Pitch influenced size measurements less for larger spheres than for smaller spheres. CTDI was typically overestimated by the scanner software compared to measurement. Conclusion: Based on this survey of acquisition parameters, a low-dose CT protocol of 120 kV, 50 mA, and pitch of 1.4 is recommended to balance patient dose and acceptable image quality. For three models of scanners, this protocol resulted in estimated CTDIs from 2.9–3.6 mGy.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation of Light to Heat Conversion by Plasmonic Nanoheaters

Plasmonic nanoparticles are widely recognized as photothermal conversion agents, i.e., nanotransducers or nanoheaters. Translation of these materials into practical applications requires quantitative analyses of their photothermal conversion efficiencies (η). However, the value of η obtained for different materials is dramatically influenced by the experimental setup and method of calculation. Here, we evaluate the most common methods for estimating η (Roper’s and Wang’s) and compare these with numerical estimates using the simulation software ANSYS. Experiments were performed with colloidal gold nanorod solutions suspended in a hanging droplet irradiated by an 808 nm diode laser and monitored by a thermal camera. The ANSYS simulations accounted for both heating and evaporation, providing η values consistent with the Wang method but higher than the Roper approach. This study details methods for estimating the photothermal efficiency and finds ANSYS to be a robust tool where experimental constraints complicate traditional methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗