Search NASASearch

SEARCH · Search NASA

Results for “stagnation heat flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

276 records · Page 5

A Probabilistic Model of a Porous Heat Exchanger

This paper presents a probabilistic one-dimensional finite element model for heat transfer processes in porous heat exchangers. The Galerkin approach is used to develop the finite element matrices. Some of the submatrices are asymmetric due to the presence of the flow term. The Neumann expansion is used to write the temperature distribution as a series of random variables, and the expectation operator is applied to obtain the mean and deviation statistics. To demonstrate the feasibility of the formulation, a one-dimensional model of heat transfer phenomenon in superfluid flow through a porous media is considered. Results of this formulation agree well with the Monte-Carlo simulations and the analytical solutions. Although the numerical experiments are confined to parametric random variables, a formulation is presented to account for the random spatial variations.

O P Agrawal

Examination of Regional Trends in Low Level Cloud Properties Found in the Aqua-MODIS Satellite Record

Clouds have a pronounced influence on the Earth?s climate. Relative to cloud free conditions, they cool the planet by increasing the amount of solar radiation reflected back to space and reducing the amount of sunlight reaching the surface, but they warm the planet by decreasing the amount of thermal infrared radiation escaping to space and increasing the amount reaching the surface (a greenhouse effect). The global mean net cloud radiative effect (CRE) is about -20 W/m2, a cooling effect at both the top-ofatmosphere and surface. Given the magnitude of CRE?s, it is expected that changes in cloud properties could be a significant factor in climate change due to anthropogenic forcing?s, yet cloud feedbacks are not well known and remain one of the largest uncertainties in climate prediction. This paper explores relationships between coincident observations of atmospheric aerosols, clouds and radiation derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) and from the Clouds and the Earth?s Radiant Energy System (CERES) instruments on the Aqua satellite. We investigate several interesting regional trends that have emerged in the nearly 18-year satellite record that suggest correlation between changes in low-level cloud properties and changes in aerosol optical depth that may be associated with changes in pollution emissions and possibly with other factors. MERRA reanalysis of meteorological conditions and aerosol particulate species are investigated to help better understand the potential mechanisms responsible for the observed cloud property trends. Finally, we analyze a new CERES flux by cloud type dataset in order to try and isolate the associated trends in low-level cloud radiative effects. It is anticipated that this study using long-term observations of clouds, aerosols and radiative fluxes combined with model reanalysis data will contribute to an improved understanding of cloud climate feedbacks.

William L Smith Jr.

The Development of A Heated-Hybrid Generated Gas Pressurization System for Propellant Tanks

One of the most important considerations in the design of liquid fueled rockets is the method utilized to transfer the propellants from the propellant tanks to the rocket engine. Use of storable liquid propellant propulsion systems, particularly those employing hydrazine as a fuel, facilitates the attractive possibility of employing the monopropellant virtues of the fuel in order to generate gases for pressurization of the propellant tanks.

GAS PRESSURE

Rechargeable Battery Auto-Cycler Requiring Lower Power and Dissipating Reduced Waste Heat

A battery charger system includes a power supply and a switch connected to the power supply wherein the switch has a first switch half and a second switch half. First and second batteries are selectively connected to the power supply via the switch. The first and second switch halves are moved between a plurality of operational positions to fully charge the first battery, discharge the first battery into the second battery, discharge the second battery into the first battery, and fully charge the second battery.

Hanson, Thomas David

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Aerothermal Shape Optimization of Actively-Cooled Battery Packs Using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

heat transfer

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Aerothermal Shape Optimization of Actively-Cooled Battery Packs using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

thermal management

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity

The Use of Immersion Rigs for High Temperature Hydrogen Exposure Testing Within the Nuclear Thermal Rocket Element Environmental Simulator (NTREES): NTREES-5 Hydrogen Heat Exchanger (N5HHX-01)

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility at NASA’s Marshall Space Flight Center (MSFC) subjects materials and components typically found on nuclear thermal propulsion (NTP) systems to non-nuclear simulations of prototypic NTP reactor thermohydraulic environments. With 1.2 MW of inductive power available, the currently employed methods to simulate nuclear heating in NTREES consist of 1) inductively heating a test specimen, which typically cannot be performed on ceramic materials, or 2) heating gas that envelops the test specimen. The latter of these has provided a basis for developing so-called “immersion rigs” to be used in NTREES. Furthermore, immersion rigs are especially useful in the case of smaller, technically challenging test specimens. One such device, the “NTREES-5 Hydrogen Heat Exchanger” (N5HHX-01), designed and deployed to test small material coupons to ~0.5 g/s of 2800 K, 500 psi Hydrogen, is discussed herein. To achieve this desired delivery temperature level, the most suitable material for the N5HHX’s construction was pure tungsten, which imposed budgetary and manufacturing challenges. Also discussed in this paper is the design of the N5HHX rig’s sample container, which became the first iteration of improving NTREES small material coupon test operations by permitting rapid changeout of different material samples.

Reactor Testing