Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard test conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources

This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller frame-work is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Developing IEEE Std 2800-Compliant Algorithms for Transmission-Connected Inverter-Based Resources: Preprint

This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.

IEEE Std 2800↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗

The effect of ICRH and NBI on tungsten transport in neon edge radiation cooled discharges in TEXTOR

Tungsten is planned to be the plasma-facing material for the main chamber and divertor in future devices like ITER, SPARC, and DTT. To address risks associated with tungsten, R&D is being carried out on various toroidal confinement devices. One particular research question is related to the optimum heating mix for ITER. To investigate the influence of the heating scheme on the release and transport of tungsten, a comparison of neutral beam injection (NBI) and ion cyclotron resonance frequency (ICRF) heating was carried out in TEXTOR tungsten test limiter experiments. The experiments were performed under standard L-mode conditions and in radiative improved-mode operation with neon seeding and boronized walls covering the graphite plasma-facing components. The plasma was heated with hydrogen or deuterium NBI alone or with deuterium NBI in combination with H-minority, ion cyclotron resonance heating. A movable solid tungsten limiter was inserted through a limiter lock system into the edge plasma. The impurity release from this limiter was evaluated from visible spectroscopy. The tungsten concentrations in the plasma core were determined by extreme ultraviolet spectroscopy and bolometry. With deuterium NBI alone, strong central radiation and accumulation of W was observed. This can, however, be avoided by adding ICRF heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying rolling resistance and air resistance simultaneously for an electric truck

Accurately estimating rolling and air resistance is essential for predicting the energy consumption of vehicles. This study presents a field-based approach using a rolldown test to simultaneously determine rolling and air resistance coefficients. Unlike prior methods that frequently used simulations or models, we employ a goal programming methodology to improve precision and evaluate the actual vehicle and environmental conditions. Our methodology was tested using a Class 8 Freightliner eCascadia on a surveyed road section, ensuring controlled conditions for data collection. By analyzing the time–velocity relationship across multiple test runs, we derived resistance coefficients for both loaded and unloaded conditions. The study confirms that rolling resistance is largely independent of velocity at low speeds but exhibits a nonlinear dependency at higher speeds. Additionally, road surface conditions, tire condition, axle configuration, aerodynamic properties, and weather conditions significantly impact resistance values, emphasizing the need for real-world testing rather than relying solely on standardized projections. Our results align with existing literature while demonstrating the efficacy of the goal programming approach in refining resistance estimates. This work contributes to improved vehicle energy modeling, offering practical insights for fleet operators and policymakers seeking accurate energy consumption predictions for electric trucks operating under varying environmental conditions.

47 OTHER INSTRUMENTATION↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anion-exchange membrane water electrolysis: insights from round-robin testing

As research and industrial interest in anion-exchange membrane water electrolysis (AEMWE) grows, there is an increasing need for reliable baselines and cross-lab validation of results. The wide variety of material sets and operating conditions under consideration for AEMWE has thus far limited efforts for standardization. In this study, round-robin testing was conducted in deionized water and KOH-based supporting electrolyte by 5 institutions from academia, national laboratories, and industry to provide baseline performance data and identify sources of cross-lab variability. Baseline membrane electrode assemblies were fabricated with commercial catalysts, membranes, and transport layers using standard techniques and tested using reagent-grade electrolytes, aiming for accessibility rather than state-of-the-art performance. From all tests, the average voltage at 1 A/cm 2 was 2.72 ± 0.17 V and 1.87 ± 0.03 V in deionized water and 0.1 M KOH, respectively. The maximum in-house and cross-lab variations at this current density were 118 mV and 476 mV in water and 60 and 88 mV in 0.1 M KOH. The KOH purity, station contamination, and temperature control were identified as possible factors affecting performance between labs, with in-house specific variation attributed to sample-to-sample differences in fabrication, cell assembly, and station contamination. This work provides a commercial baseline for the field and highlights the need for improved standardization and reproducibility in AEMWE research.

08 HYDROGEN↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Dataset of tensile properties for sub-sized specimens of nuclear structural materials

Mechanical testing with sub-sized specimens plays an important role in the nuclear industry, facilitating tests in confined experimental spaces with lower irradiation levels and accelerating the qualification of new materials. The reduced size of specimens results in different material behavior at the microscale, mesoscale, and macroscale, in comparison to standard-sized specimens, which is referred to as the “specimen size effect.” Although analytical models have been proposed to correlate the properties of sub-sized specimens to standard-sized specimens, these models lack broad applicability across different materials and testing conditions. The objective of this study is to create the first large public dataset of tensile properties for sub-sized specimens used in nuclear structural materials. We performed an extensive literature review of relevant publications and extracted over 1,000 tensile testing records comprising 55 columns including material type and composition, manufacturing information, irradiation conditions, specimen dimensions, and tensile properties. The dataset can serve as a valuable resource to investigate the specimen size effect and develop computational methods to correlate the tensile properties of sub-sized specimens.

36 MATERIALS SCIENCE↗

Initial Alloy 709 constitutive models for use with the ASME design by inelastic analysis and EPP+SMT design methods

This report details a preliminary inelastic constitutive model describing the behavior of Alloy 709. This model will serve two purposes: (1) integration into Nonmandatory Appendix HBB-Z of the ASME Boiler & Pressure Vessel Code Section III, Division 5 and (2) extrapolating cyclic test data to difficult to measure conditions for formulating improved creep-fatigue design methods. For both applications, the model must accurately capture the material behavior across a wide range of temperatures and a variety of test conditions, both monotonic and cyclic. For this purpose we adopt a universal model form under consideration to standardize the description of high temperature constitutive models in the ASME Code. This report briefly restates that model form and how we calibrate the model against the test data, summarizes the test database, and validates the final, trained model by comparison to the experimental tests.

36 MATERIALS SCIENCE↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗

Equibiaxial Flexure Strength of a Superfine-Grained Nuclear Graphite

The strength of advanced graphite is reported in accordance with ASTM D7846-16 using a two-parameter Weibull distribution for uniaxial strength testing. The rule of thumb for Weibull distributions is to use a minimum of 30 strength measurements to have a high level of confidence in the Weibull characteristic strength and the Weibull modulus. These large sample sets for statistical confidence are easily obtained for as-manufactured graphite, but determination of the Weibull two-factor parameters on graphite that has been exposed to neutron irradiation is nearly impossible due to irradiation testing restraints on specimen size and space limitations in test reactors for the accommodation of specimens. These restrictions have resulted in irradiation programs that use sub-sized specimens to measure uniaxial strength change, but the specimen geometries still hinder the number of replicate specimens for each irradiation condition. In contrast, this work used an advanced ceramic standard, ASTM C1499-05, as the foundation for equibiaxial strength testing of a superfine-grained nuclear graphite to investigate the irradiation-induced strength change and any changes to the two-parameter Weibull distribution. The goal was to investigate the effect of specimen size on the two-parameter Weibull distribution parameters in support of the small specimens and geometry desired for irradiation. A study of the effect of a reduced sample population was also undertaken to investigate the reliability of using the two-parameter Weibull distribution to study changes to the materials properties caused by neutron irradiation damage. The results of this work suggest that these equibiaxial specimens would be ideal for statistically significant studies of the effects of irradiation on the Weibull characteristic strength (but not the modulus) and for providing a method for surveillance specimen campaigns for future operating commercial reactors.

Campbell, Anne↗

Results from Laboratory and Field Study of Thin Triple Pane Windows

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak cooling load of a home. In recent years, improvements in glass manufacturing have enabled the use of a very thin central pane of glass similar to a cell phone screen to produce a thin triple-pane window, for finished insulated glass units (IGUs) with an overall thickness similar to standard double-pane windows. Because this highly insulating “thin triple” glass product can be incorporated into almost any existing window frame and can be fabricated at a modest added cost, the U.S. Department of Energy sponsored laboratory and field demonstration testing of thin triple-pane windows to validate thermal performance and installation requirements in real-life field settings. Thin triple pane windows were evaluated at the PNNL Lab Homes, a matched pair of manufactured houses located on PNNL’s campus in Richland, Washington and also at 16 different field study sites around the country. The experimental results include a comparison of heating, ventilation, and air-conditioning (HVAC) energy usage, condensation potential, occupant comfort, sound infiltration, and thermal performance. Field study data will be gathered through June of 2022; preliminary results are being shared in this paper. The lab houses are identical except that the reference house had standard double pane windows with assembly U-0.66 and the test house had thin triple pane windows with assembly U-0.19. Across the experimental test days, the daily HVAC savings ranged from 0.2 to 18.7 kWh (3%–18%) for the heating season and from 2.5 to 8.0 kWh (23%–41%) for the cooling season. The higher thermal performance of the thin triple-pane windows also reduced the condensation potential on the interior surface during winter months and provided more even distribution of temperatures throughout the home in comparison to the baseline. In addition to the added thermal performance, the thin triple-pane windows demonstrated significant acoustic benefits, reducing sound infiltration by 8 dB to 10 dB. For the field test portion of the project thin triple pane insulated glass units were produced by two different manufacturers, and then installed without modification into the ½” IGU pockets of the standard double pane frames of four other manufacturers. Field tests performed on existing homes in Washington, Montana, Colorado, and New York compared thin triple pane retrofits to original window conditions (before and after). Field tests at new construction sites in Minnesota, Michigan, and New York compared thin triple pane windows to commercially available solutions such as double pane or traditional triple pane (with a standard-thickness center pane). Field test work is ongoing, but preliminary results appear to follow the sound, surface temperature, and energy improvement results from the Lab Homes comparison. Additionally, reports from builders and installers indicate that thin triples require almost no added time or effort to install and look nearly identical to other windows, indicating the possibility of offering next-level performance with a product that requires very little modification to current production or installation practices, long considered a major barrier to technology uptake in the construction market.

energy efficiency, home retrofit, Windows, window ↗

Using Spectral Measurements to Characterize Solar Reference Cells on a Two-Axis Tracker

A study is commencing relating the spectral responsivity of reference cells in the field to changing spectral distribution during the day. Initial results indicate that measurements of the incident spectral distribution can be used to match results of reference cell measurements on a two-axis tracker with a standard deviation of ±0.25% under clear-sky conditions. Initial results are provided. As more data are obtained covering a variety of field conditions and locations, the robustness of these results will be tested. The website https://midcdmz.nrel.gov/apps/sitehome.pl?site=PVRES contains the data generated by this project.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Engineered bone marrow as a clinically relevant ex vivo model for primary bone cancer research and drug screening

Osteosarcoma (OS) is the most common primary malignant bone cancer in children and adolescents. While numerous other cancers now have promising therapeutic advances, treatment options for OS have remained unchanged since the advent of standard chemotherapeutics and offer less than a 25% 5-y survival rate for those with metastatic disease. This dearth of clinical progress underscores a lack of understanding of OS progression and necessitates the study of this disease in an innovative system. Here, we adapt a previously described engineered bone marrow (eBM) construct for use as a three-dimensional platform to study how microenvironmental and immune factors affect OS tumor progression. We form eBM by implanting acellular bone-forming materials in mice and explanting the cellularized constructs after 8 wk for study. We interrogate the influence of the anatomical implantation site on eBM tissue quality, test ex vivo stability under normoxic (5% O 2 ) and standard (21% O 2 ) culture conditions, culture OS cells within these constructs, and compare them to human OS samples. We show that eBM stably recapitulates the composition of native bone marrow. OS cells exhibit differential behavior dependent on metastatic potential when cultured in eBM, thus mimicking in vivo conditions. Furthermore, we highlight the clinical applicability of eBM as a drug-screening platform through doxorubicin treatment and show that eBM confers a protective effect on OS cells that parallel clinical responses. Combined, this work presents eBM as a cellular construct that mimics the complex bone marrow environment that is useful for mechanistic bone cancer research and drug screening.

59 BASIC BIOLOGICAL SCIENCES↗