Low Earth Orbital Mission Aboard the Space Test Experiments Platform (STEP-3)

A discussion of the Space Active Modular Materials Experiments (SAMMES) is presented in vugraph form. The discussion is divided into three sections: (1) a description of SAMMES; (2) a SAMMES/STEP-3 mission overview; and (3) SAMMES follow on efforts. The SAMMES/STEP-3 mission objectives are as follows: assess LEO space environmental effects on SDIO materials; quantify orbital and local environments; and demonstrate the modular experiment concept.

Brinza, David E.↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Supersonic burning in separated flow regions

Activities reported include: (1) the construction of a thermocouple with a protective coating or sheath for obtaining reliable temperature measurements of gases in the base region; (2) the construction of a multiposition back step plate for trough tests for step sizes 0.63 cm and 0.25 cm; and (3) flow pattern studies with the 6.35 cm trough to determine the complex flow resulting when a shear layer reattaches in a corner. Reliable ignition and stable burning were achieved at Mach = 2 for the 0.63 cm trough. Photographs of side wall oil streaks for M=2 flow, and some static and pitot pressure results at M = 3 are included.

Zumwalt, G. W.↗

New insights on carbon black suspension rheology—Anisotropic thixotropy and antithixotropy

We report a detailed experimental study of peculiar thixotropic dynamics of carbon black (CB, Vulcan XC-72) suspensions in mineral oil, specifically the observation of sequential stress increase then decrease at a fixed shear rate in a step-down test. We verify that such dynamics, though peculiar, come from a true material response rather than experimental artifacts. We also reveal how this long-time stress decay is associated with antithixotropic structural change rather than viscoelastic stress relaxation by using orthogonal superposition (OSP) rheometry to probe viscoelastic moduli during the step-down tests. The orthogonal storage and loss moduli are present, showing this two-timescale recovery then decay response, which demonstrates that this response is antithixotropic, and it involves shear-induced structuring. We further show a mechanical anisotropy in the CB suspension under shear using OSP. Based on the rheological results, a microstructural schematic is proposed, considering qualitatively thixotropic structure build-up, antithixotropic densification, and anisotropic structure evolution. Our observation for these CB suspensions is outside the standard paradigm of thixotropic structure-parameter models, and the elastic response provides us with new insight into the transient dynamics of CB suspensions.

Mechanics↗

Transistor step stress program for JANTX2N4150

Reliability analysis of the transistor JANTX2N4150 manufactured by General Semiconductor and Transitron is reported. The discrete devices were subjected to power and temperature step stress tests and then to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented.

Source record↗

A Graphical User Interface for the Deep Underground Neutrino Experiment Robotic Test Stand

In preparation for DUNE, Fermilab along with six other institutions are testing cold electronics for quality control before components placed in the far detector. We test them by using a robotic arm that places these chips into sockets on a computer board that will test their functionality. Up until now, the chips have been tested using a command line script that drives a state machine to conduct tests step-by-step. In order to lower the skill barrier to conduct tests and to speed up the quality control process, I was tasked to create a graphical user interface that would allow users to use buttons, text boxes, and drop-down menus to input information and tell the testing state machine how to operate. I had to learn about the Python package Tkinter to start the process of widget placement. I further developed a pause feature unused in the previous command line script that would allow the user to shut down testing gracefully, bring the robotic arm to go back to ground state, and go forward or backward a step in the testing process. After completing the basic functionality of the GUI, I started testing production chips with the GUI to debug. Some issues were found, which required me to further develop parts of the inherited state machine code. The code for the GUI has now been pushed into the copy the DUNE/FD_CE git repository and will soon be merged with the official DUNE/FD_CE repository so that the other institutions testing DUNE cold electronics can use and expand upon it.

Gutierrez Villanueva, Jaziel [Fermilab]↗

A Step Towards Electric Propulsion Testing Standards: Pressure Measurements and Effective Pumping Speeds

The electric propulsion community has been implored to establish and implement a set of universally applicable test standards during the research, development, and qualification of electric propulsion systems. Existing practices are fallible and result in testing variations which leads to suspicious results, large margins in application, or aversion to mission infusion. Performance measurements and life testing under appropriate conditions can be costly and lengthy. Measurement practices must be consistent, accurate, and repeatable. Additionally, the measurements must be universally transportable across facilities throughout the development, qualification, spacecraft integration and on-orbit performance. A preliminary step to progress towards universally applicable testing standards is outlined for facility pressure measurements and effective pumping speed calculations. The standard has been applied to multiple facilities at the NASA Glenn Research Center. Test results and analyses of universality of measurements are presented herein.

Dankanich, John W.↗

Failure Modes in Capacitors When Tested Under a Time-Varying Stress

Steady step surge testing (SSST) is widely applied to screen out potential power-on failures in solid tantalum capacitors. The test simulates the power supply's on and off characteristics. Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors for decoupling applications. On the other hand, the SSST can also be reviewed as an electrically destructive test under a time-varying stress. It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. Highly accelerated life testing (HALT) is usually a time-efficient method for determining the failure mechanism in capacitors; however, a destructive test under a time-varying stress like SSST is even more effective. It normally takes days to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating specific time-varying stress into a statistical model is significant in providing an alternative life test method for quickly revealing the failure modes in capacitors. In this paper, a time-varying stress has been incorporated into the Weibull model to characterize the failure modes. The SSST circuit and transient conditions to correctly test the capacitors is discussed. Finally, the SSST was applied for testing polymer aluminum capacitors (PA capacitors), Ta capacitors, and multi-layer ceramic capacitors with both precious metal electrode (PME) and base-metal-electrodes (BME). It appears that testing results are directly associated to the dielectric layer breakdown in PA and Ta capacitors and are independent on the capacitor values, the way the capacitors being built, and the manufactures. The testing results also reveal that ceramic capacitors exhibit breakdown voltages more than 20 times the rated voltage, and the breakdown voltages are inverse proportional to the dielectric layer thickness. The possibility of ceramic capacitors in front-end decoupling applications to block the surge noise from a power supply is also discussed.

Liu, David (Donhang)↗

Alternator insulation evaluation tests

Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.

Penn, W. B.↗

Tank tests of two models of flying-boat hulls to determine the effect of ventilating the step

The results of tests made in the N.A.C.A. tank on two models of flying-boat hulls to determine the effect of ventilating the step are given graphically. The step of N.A.C.A. model 11-C was ventilated in several different ways and it was found that the resistance of the normal form is not appreciably affected by artificial ventilation in any of the forms tried. Further tests made with the depth of the step of model 11-C reduced likewise show no appreciable effect on the resistance from ventilation of the step. Tests were made on a model of the hull of the Navy P3M-1 flying-boat hull both with and without ventilation of the step. It was found that the discontinuity which is obtained in the resistance curves of this model is eliminated by ventilating the step.

Dawson, John R↗

Testing Large Structures in the Field

Field testing large structures creates unique challenges such as limited choices for boundary conditions and the fact that natural excitation sources cannot be removed. Several critical developments in field testing of large structures are reviewed, including: step relaxation testing which has been developed into a useful technique to apply large forces to operational systems by careful windowing; the capability of large structures testing with free support conditions which has been expanded by implementing modeling of the support structure; natural excitation which has been developed as a viable approach to field testing; and the hybrid approach which has been developed to allow forces to be estimated in operating structures. These developments have increased the ability to extract information from large structures and are highlighted in this presentation.

James, George↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Numerical tests of a modified full implicit continuous Eulerian (FICE) scheme with projected normal characteristic boundary conditions for MHD flows

A numerical method has been developed based on a modified full implicit continuous Eulerian (FICE) scheme and projected normal characteristic boundary conditions for simulating MHD flows which undergo a long process of evolution. An astrophysical flow is chosen for illustration of this procedure, and numerical tests are made to verify the computational stability and physically realistic solution. Three computational tests have been accomplished; they are tests of solving methods, characteristic boundary condition, and time steps. The tests show that the program from the modified FICE scheme with proper boundary conditions and time steps can be made numerically stable for a time long enough to obtain physically plausible solutions.

Wu, S. T.↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Wells RWM 6 and RWM 7

Hydrologic tests were conducted on the Lost Lake Aquifer Zone (LLAZ) at recovery wells RWM 6 and RWM 7 in accordance with the approved test plan (Dixon, 2023). The objective of the testing was to determine well performance parameters of RWM 6 and aquifer hydraulic properties near RWM 6 and RWM 7. Tests at RWM 6 consisted of a step-drawdown test to determine well performance parameters, a constant rate pump test to determine aquifer hydraulic properties, and an aquifer recovery test also used to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. Prior to testing at RWM 6, a constant rate pump test was conducted at RWM 7. Data from this testing was used to determine aquifer hydraulic properties near RWM 7.

42 ENGINEERING↗

Fatigue Life Methodology for Bonded Composite Skin/Stringer Configurations

A methodology is presented for determining the fatigue life of composite structures based on fatigue characterization data and geometric nonlinear finite element (FE) analyses. To demonstrate the approach, predicted results were compared to fatigue tests performed on specimens which represented a tapered composite flange bonded onto a composite skin. In a first step, tension tests were performed to evaluate the debonding mechanisms between the flange and the skin. In a second step, a 2D FE model was developed to analyze the tests. To predict matrix cracking onset, the relationship between the tension load and the maximum principal stresses transverse to the fiber direction was determined through FE analysis. Transverse tension fatigue life data were used to -enerate an onset fatigue life P-N curve for matrix cracking. The resulting prediction was in good agreement with data from the fatigue tests. In a third step, a fracture mechanics approach based on FE analysis was used to determine the relationship between the tension load and the critical energy release rate. Mixed mode energy release rate fatigue life data were used to create a fatigue life onset G-N curve for delamination. The resulting prediction was in good agreement with data from the fatigue tests. Further, the prediction curve for cumulative life to failure was generated from the previous onset fatigue life curves. The results showed that the methodology offers a significant potential to Predict cumulative fatigue life of composite structures.

Krueger, Ronald↗