Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface profilometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

AM metal substrates for inkjet-printing of smart devices

Highlights: • An experimental study to characterize 3D-printed metal substrates and their surfaces for inkjet-printing is presented. • Multilayer structures composed of an insulating layer and a superposed conductive layer, inkjet-printed onto various metallic substrates. • Characterization based on microscopic and Focused Ion Beam (FIB) images, profilometer and contact angle measurements of the substrates. • Microscopic images and four-point-probe resistance- and profilometer measurements to gain insight into the quality of the multilayer print. - Abstract: A study to characterize surface and structural properties of 3D-printed metal substrates for multilayer inkjet-printing is presented. Such substrates can enable and alleviate the fabrication of smart and functional packages, implants or spare parts. For the characterization, a multilayer structure composed of an insulating layer and a superposed conductive layer is inkjet-printed onto the various 3D-printed metallic substrates. The printing is done using equivalent settings for all substrates. The characterization is based on microscopic and Focused Ion Beam (FIB) images, as well as profilometer and contact angle measurements of the substrates. Furthermore, microscopic images and four-point-probe resistance- and profilometer measurements are carried out, to gain insight into the quality of the multilayer print. We show the diversity in surface and structural properties of 3D-printed substrates, also for those fabricated using the same process. Also, the 3D-printed samples exhibit different wettability properties than metals processed using standard processes. Finally, we can also demonstrate the suitability of selected substrates for inkjet-printing.

36 MATERIALS SCIENCE↗

Design and Development of a Laboratory-Scale Ice Adhesion Testing Device

When an aircraft traverses through clouds containing supercooled water droplets, in-flight icing can occur that negatively affects vehicle performance by increasing weight and drag leading to loss of lift. Super-cooled water droplets present in clouds that impact vehicle surfaces can lead to inflight icing any time during the year.1 Most events occur at temperatures ranging from 0 to -20degC. Ice generated on the aircraft can vary between clear/glaze, rime, and mixed (Fig. 1) depending on air temperature (-5 to -20degC), liquid water content (0.3-0.6 g/m3), and droplet size (median volumetric diameter of 15-40 μm). Current strategies to remove ice are based on active technologies such as pneumatic boots, heated surfaces, and deicing agents (i.e., ethylene- and propylene-based glycols). The latter have potential environmental concerns. A passive approach to mitigate accreting ice that is actively being investigated are protective coatings. An ice mitigating coating could potentially be used as a stand-alone material, but more likely in combination with an active approach. In the latter scenario, potential reduction in power consumption by the active approach may be realized. To determine the ice adhesion strength of impact ice that is representative of the aircraft environment is not a trivial matter. Test methods utilizing slowly formed ice (i.e., freezer ice) do not accurately simulate this environment. Likewise, some testing methodologies involve sample relocation from the icing environment to the test chamber that can result in thermal shock to the sample, thus affecting the results. The Adverse Environment Rotor Test Stand (AERTS) located at Pennsylvania State University (PSU) has been demonstrated to simulate impact icing conditions within the icing envelope for the determination of ice adhesion shear strength (IASS) without removal/relocation of the sample.2 Due to the confidence in results obtained from AERTS, this instrument is in high demand and requires a significant amount of lead time and capital investment to obtain IASS results. As a solution for quickly and economically screening coatings in a controlled manner under impact icing conditions, a laboratory-scale ice adhesion test and dead blades were then removed from the rotor/blade assembly to obtain the final mass. The IASS of the live blade was determined from the difference in mass (before and after testing) of the live and dead blades, the ice shed area, and the rpm of the shed event. The same live blade sample was tested in triplicate at all three test temperatures. Surface roughness was determined using a Bruker Dektak XT Stylus Profilometer. Measurements were conducted using a 12.5 μm tip at a vertical range of 65.5 μm with an applied force of 3 mg. Data were collected over a 1.0 mm length at a resolution of 0.056 μm/point. Five single line scans at different locations were collected and processed using a two-point leveling subtraction. The resultant Ra (arithmetic roughness) and Rq (root mean square roughness) average values were calculated.

Smith, Joseph G., Jr.↗

Solid particle impingement erosion characteristics of cylindrical surfaces, pre-existing holes and slits

The erosion characteristics of aluminum cylinders sand-blasted with both spherical and angular erodent particles were studied and compared with results from previously studied flat surfaces. The cylindrical results are discussed with respect to impact conditions. The relationship between erosion rate and pit morphology (width, depth, and width to depth ratio) is established. The aspects of (1) erosion rate versus time curves on cylindrical surfaces; (2) long-term exposures; and (3) erosion rate versus time curves with spherical and angular particles are presented. The erosion morphology and characteristics of aluminum surfaces with pre-existing circular cylindrical and conical holes of different sizes were examined using weight loss measurements, scanning electron microscopy, a profilometer, and a depth gage. The morphological features (radial and concentric rings) are discussed with reference to flat surfaces, and the erosion features with spherical microglass beads. The similarities and differences of erosion and morphological features are highlighted. The erosion versus time curves of various shapes of holes are discussed and are compared with those of a flat surface. The erosion process at slits is considered.

Rao, P. V.↗

Effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn alloy

An investigation into the effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn is presented. Damage to surface integrity and changes in the residual stresses distribution are studied to assess changes in fatigue life. A surface grinding machine, operating at speeds ranging from 2000 to 6000 fpm and using SiC wheels of grit sizes 60 and 120, was used to grind flat subsize specimens of 0.1-in. thickness. After grinding, the specimens were fatigued at a chosen stress and compared with the unadulterated material. A standard profilometer, a microhardness tester, and a scanning electron microscope were utilized to examine surface characteristics and measure roughness and hardness. Increased grinding speed in both wet and dry applications tended to decrease the fatigue life of the specimens. Fatigue life increased markedly at 2000 fpm under wet conditions, but then decreased at higher speeds. Grit size had no effect on the fatigue life.

Rangaswamy, P.↗

Ultrasound guided fluorescence molecular tomography with improved quantification by an attenuation compensated born-normalization and in vivo preclinical study of cancer

Ultrasound imaging, having the advantages of low-cost and non-invasiveness over MRI and X-ray CT, was reported by several studies as an adequate complement to fluorescence molecular tomography with the perspective of improving localization and quantification of fluorescent molecular targets in vivo. Based on the previous work, an improved dual-modality Fluorescence-Ultrasound imaging system was developed and then validated in imaging study with preclinical tumor model. Ultrasound imaging and a profilometer were used to obtain the anatomical prior information and 3D surface, separately, to precisely extract the tissue boundary on both sides of sample in order to achieve improved fluorescence reconstruction. Furthermore, a pattern-based fluorescence reconstruction on the detection side was incorporated to enable dimensional reduction of the dataset while keeping the useful information for reconstruction. Due to its putative role in the current imaging geometry and the chosen reconstruction technique, we developed an attenuation compensated Born-normalization method to reduce the attenuation effects and cancel off experimental factors when collecting quantitative fluorescence datasets over large area. Results of both simulation and phantom study demonstrated that fluorescent targets could be recovered accurately and quantitatively using this reconstruction mechanism. Finally, in vivo experiment confirms that the imaging system associated with the proposed image reconstruction approach was able to extract both functional and anatomical information, thereby improving quantification and localization of molecular targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Figure Measurements of High-Energy-X-Ray Replicated Optics

We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. One of the sources for mirror resolution error is departure of the shell figure from prescription. We have modified a Vertical-scan Long Trace Profilometer (VLTP) in order to measure the figure of the inner surface of the HERO mirror shells for diameters as small as 76 mm. Mirror alignment method and sources for systematic errors will be discussed. Comparison of figure metrology of the mandrel and the shells will be presented together with results from x-ray tests.

Gubarev, Mikhail↗

Optimization of the size and shape of the scanning aperture in autocollimator-based deflectometric profilometers

Deflectometric profilometers based on industrial electronic autocollimators (ACs), as the ELCOMAT-3000, have become indispensable tools for precision form measurements of optical surfaces. A growing number of labs at synchrotron and free electron laser x-ray facilities are going for BESSY-II NOM-like versions of the AC-based profilometers. These tools have proven capable of characterizing state-of-the-art aspherical x-ray optics with an accuracy on the level of 100 nrad (root-mean-square) over the spatial frequency range limited by the size of the aperture used in the profilometer. Normally, a round aperture with a diameter of about 2.5 mm is used. Previous investigations have shown that with the optimally aligned 2.5-mm aperture, the spatial resolution of a NOM-like profilometer corresponding to the first zero-crossing of the optical transform function (OTF) is ~1.2 mm. In this paper, we investigate the performance of an AC ELCOMAT-3000 for a slope profilometer with different aperture sizes and shapes. The results of angular calibration of the AC equipped with circular and rectangular apertures placed at different distances from the AC are discussed. The calibration was performed at the Physikalisch-Technische Bundesanstalt using the original experimental arrangements, also discussed in the paper. The OTF measurements with the specially developed test sample with chirped surface slope profiles were performed at the Advanced Light Source X-Ray Optics Laboratory (XROL) in application to a new optical surface measuring system under development at the XROL. In the OTF measurements, we have shown that application of a rectangular aperture with dimensions of 1.5 mm × 3 mm improves the spatial resolution in the tangential direction by a factor of ~1.4 compared to that of the standard circular aperture of 2.5-mm diameter. We postulate that the conclusions of our investigations are crucial for reaching fundamental metrological limits in deflectometric profilometry utilizing state-of-the-art electronic autocollimators.

47 OTHER INSTRUMENTATION↗

Characterization of Surface Features in Detached Grown GeSi Crystals

The growth of detached crystals by the Bridgman technique, in which the growing crystal is not in contact with the crucible wall, has been observed both on earth and in microgravity conditions. At present, the mechanisms contributing to the detachment are not completely understood and until recently detachment has not been reproducibly obtained. It is commonly understood that the main factors that promote the occurrence of detached growth include: high contact angle between the melt and the crucible material, high growth angle, and a pressure difference between the annular gap around the solid below the melt and the volume above the melt along the meniscus. These parameters were varied in Bridgman growth experiments to determine the conditions required to achieve detached growth terrestrially in Ge and GeSi alloys. These experiments are in preparation for experiments on the International Space Station (ISS). The detailed objectives of the flight experiments and a description of the growth methods employed are the subject of another presentation at this Congress. Detached crystals were achieved repeatedly in pyrolytic boron nitride ampoules when a pressure difference was employed. All crystals, except for those grown in fused silica ampoules, were easily removed from their containers; however, this fact alone is not sufficient to infer detached growth. Detachment was verified by comparing profilometer measurements of the radius of the samples with observations of the sample surfaces using optical and electron microscopy. The surfaces of the attached areas of the crystals had the same shape and surface texture as the interior crucible wall. Regions of detached growth contained many unique features and crystal facets could usually be observed. Several of these surface features have been correlated with mechanisms of detachment or free surface growth in general and others to processing events or conditions. These results will be compared with observations of surface features on detached regions of microgravity grown crystals.

Cobb, S. D.↗

Characterization of Surface Features in Detached Grown GeSi Crystals

The growth of detached crystals by the Bridgman technique, in which the growing crystal is not in contact with the crucible wall, has been observed both on earth and in microgravity conditions. At present, the mechanisms contributing to the detachment are not completely understood and until recently detachment has not been reproducibly obtained. It is commonly understood that the main factors that promote the occurrence of detached growth include: high contact angle between the melt and the crucible material, high growth angle, and a pressure difference between the annular gap around the solid below the melt and the volume above the melt along the meniscus. These parameters were varied in Bridgman growth experiments to determine the conditions required to achieve detached growth terrestrially in Ge and GeSi alloys. These experiments are in preparation for experiments on the International Space Station (ISS). The detailed objectives of the flight experiments and a description of the growth methods employed are the subject of another presentation at this Conference. Detached crystals were achieved repeatedly in pyrolytic boron nitride ampoules when a pressure difference was employed. All crystals, except for those grown in fused silica ampoules, were easily removed from their containers, however, this fact alone is not sufficient to infer detached growth. Detachment was verified by comparing profilometer measurements of the radius of the samples with observations of the sample surfaces using optical and electron microscopy. The surfaces of the attached areas of the crystals had the same shape and surface texture as the interior crucible wall. Regions of detached growth contained many unique features and crystal facets could usually be observed. Several of these surface features have been correlated with mechanisms of detachment or free-surface growth and others to processing events or conditions.

Cobb, S. D.↗

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery↗

Discerning Cell Surface Defects with 3D Optical Profilometry

This investigation seeks to establish better criteria that can be used for qualitative visual screening of cylindrical battery cells through exploration of various defects across multiple cylindrical Lithium-Ion battery cells. This investigation focuses on INR18650s and INR21700s cells from Molicel, LG, and Samsung. The principal instrument used is a high-definition 3D optical profilometer with measurement accuracy less than 0.5 microns. Through this effort, a catalog was built discerning minor surface imperfections from significant flaws. The catalog generated covers a comparison of axial and radial scratches, less than 5 microns, greater than 5 microns and greater than 15 microns, as well as the difference between surface discoloration, early-stage pitting, and late stages of corrosion. An exploration is made into cell button defects and crimp shoulder defects. When ultra-high-power optical magnification and three-dimension topological tools are not immediately available, this catalog will help determine if an individual cell is usable, worth further investigation, or failing. The purpose of this catalog is to be a field guide used for quick reference of a potential issue, with the goal of increasing screening throughput while reducing the need for costly examination. Trade names and trademarks are used in this abstract for identification only. Their usage does not constitute an official endorsement, either expressed or implied, by the National Aeronautics and Space Administration.

battery↗

Solvent effect on polystyrene surface roughness on top of QCM sensor

Quartz Crystal Microbalance (QCM) has been used as a basis for many chemical sensors and biosensor. Its sensitivity to mass change which can detect a mass change on its surface down to sub ng/cm2 is one of its interesting aspects. Another interesting feature is its ability to work in liquid environment. However, there are many aspects which influence QCM sensor properties in contact with liquid. One of the aspects is surface roughness of the matrix layer where on top of it a biological sensitive layer will be immobilized. One of matrix layers in the immobilizing biological sensitive layer was polystyrene. Polystyrene was coated on the QCM sensor by using the spin coating method. During the coating process, polystyrene was solved using non-polar solvent. It is known that the physical and chemical properties of the solvent affect a transition process from soluble polymer becoming rigid polymer layer. In this work, we show that polystyrene solved in chloroform has a higher surface roughness compare to one solved in toluene, xylene, or tetrahydrofuran. Surface roughness of the polystyrene coating were measured using a non-contact profilometer. However, we also found that there is no difference on the electrical impedance of the QCM sensor coated with polystyrene resulted from differing solvent when the sensor was in contact with air and water. Thus, all of the mentioned solvent can be used to solve the polystyrene as a coating material for QCM sensor without affecting the electrical performance of the sensor, but the choice of the solution can be used as a simple method to control the difference roughness of the polystyrene coating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative In Vitro Evaluation Between Zirconia and Veneer Ceramic Materials Using Different Techniques

Zirconia surface treatment using different techniques could be employed to overcome the delamination issue reported between veneering ceramic materials and the corresponding zirconia core. The study subjected yttria partially stabilized zirconia core material to grinding and sandblasting as a first surface treatment. An airbrush gun spraying technique was used to coat a uniform thin layer of veneering ceramic (IPS e.max Ceram and Noritake Cerabien ZR) on the core materials followed by performing laser scanning as a second surface treatment. The specimens were investigated for surface topography, interface analysis, elemental compositions, phase transformation, and fracture mode patterns using profilometer, SEM, EDS, XRD, and stereomicroscope. The impact of laser scanning on the shear bond strength before and after storage of specimens in artificial saliva was also studied. Transformable tetragonal phase to monoclinic was predominant in sandblasted specimens followed by laser scanning with observation of micro-cracks at interface. The grinding followed by laser scanning yielded satisfactory outcomes in terms of the presence of coating property. The phase transformation was not detected through the latter technique. The technique greatly enhanced the roughness property and bond strength values which might be considered as a reliable application to improve the longevity of fixed dental crowns in load bearing areas.

36 MATERIALS SCIENCE↗

Pulsed laser deposition to synthesize the bridge structure of artificial nacre: Comparison of nano- and femtosecond lasers

Nature offers inspiration to new adaptive technologies that allow us to build amazing shapes and structures such as nacre using synthetic materials. Consequently, we have designed a pulsed laser ablation manufacturing process involving thin film deposition and micro-machining to create hard/soft layered 'brick-bridge-mortar' nacre of AlMgB{sub 14} (hard phase) with Ti (soft phase). In this paper, we report pulsed laser deposition (PLD) to mimic brick and bridge structures of natural nacre in AlMgB{sub 14}. Particulate formation inherent in PLD is exploited to develop the bridge structure. Mechanical behavior analysis of the AlMgB{sub 14}/Ti system revealed that the brick is to be 250 nm thick, 9 {mu}m lateral dimensions while the bridge (particle) is to have a diameter of 500 nm for a performance equivalent to natural nacre. Both nanosecond (ns) and femtosecond (fs) pulsed lasers were employed for PLD in an iterative approach that involves varying pulse energy, pulse repetition rate, and target-to-substrate distance to achieve the desired brick and bridge characteristics. Scanning electron microscopy, x-ray photoelectron spectroscopy, and optical profilometer were used to evaluate the film thickness, particle size and density, stoichiometry, and surface roughness of thin films. Results indicated that both ns-pulsed and fs-pulsed lasers produce the desired nacre features. However, each laser may be chosen for different reasons: fs-pulsed laser is preferred for much shorter deposition time, better stoichiometry, uniform-sized particles, and uniform film thickness, while ns-pulsed laser is favored for industrial acceptance, reliability, ease of handling, and low cost.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interaction of atomic oxygen with thin film and bulk copper: An XPS, AES, XRD, and profilometer study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed primarily to study degradation of material surfaces due to low earth orbital (LEO) atmospheric oxygen. The experiment contained 128 one inch circular samples: metals, polymers, carbons, and semiconductors. Among metal samples, copper has shown some interesting new results. Two types of copper samples, a film sputter coated on fused silica and a bulk piece of OFHC copper, were characterized employing a variety of techniques such as X-ray and Auger electron spectroscopies, X-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to characterize the presence of Cu2O and CuO in addition to Cu Auger LMM lines. These results are supported by our recent X-ray diffraction studies which clearly establish the presence of Cu oxides which we were unable to prove in our earlier work. Profilometry showed an increase in thickness of the film sample where exposed to 106.7 +/- 0.5 nm from an initial thickness of 74.2 +/- 1.1 nm. Further studies with SEM and ellipsometry are underway.

Raikar, Genesh N.↗

Dendrite-free Al recycling via electrodeposition using ionic liquid electrolytes: The effects of deposition temperature and cathode surface roughness

In this report, the electrodeposition of Al from aluminum scrap alloys (A2020) on copper cathode substrates with varied surface roughness under different deposition temperatures was studied using low-temperature AlCl 3 -1-butyl-3-methyl-imidazolium chloride (BMIC) ionic liquid electrolytes. The bulk electrodeposition of Al was carried out under a voltage of 1.5 V at a stirring rate of 120 rpm using a fixed ionic liquid electrolyte concentration (molar ratio AlCl 3 : BMIC = 2:1). The effects of deposition temperature (range from 80 °C to 140 °C) and surface roughness of Cu cathode substrates (polished by 320, 600, 800, 1200 grits SiC sandpapers and mirror polishing process) on the morphology of deposited Al, current density, current efficiency and energy consumption, were investigated. The Al deposits were characterized using scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), profilometer, and electrochemical measurements for current density, current efficiency, and energy consumption. It is demonstrated that the deposition temperature and surface roughness of Cu electrodes play a critical role in the nucleation and growth of Al deposits. Higher deposition temperature promotes the diffusion and/or migration of Al 2 Cl 7 - ions and then enhances the current density and efficiency during the electrodeposition of Al. Smoother surface of Cu electrodes is preferred for the formation of dendrite-free Al deposits. Typically, on the mirror polished Cu electrode, no Al dendrite structure was observed, and only plate-like Al deposits were formed at the deposition temperature of 100 °C. Pure metallic Al was successfully deposited on Cu electrodes in AlCl 3 + BMIC ionic liquid electrolytes for all experiments with a current efficiency range from 72% to 99% and energy consumption of 4.6–6.3 kW h/kg Al.

54 ENVIRONMENTAL SCIENCES↗

Optical profilometer

Device, consisting of optical scanning subsystem, two light detectors with associated amolifiers, analog divider, and adjustable nonlinear function generator, directly determines surface area, absolute depth, and point-to-point distance of three-dimensional object without physical contact with surface under observation.

Burcher, E. E.↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗