A frequency and amplitude scanned quadrupole mass filter for the analysis of high m/z ions

Quadrupole mass filters (QMFs) are usually not used to analyze high m/z ions, due to the low frequency resonant circuit that is required to drive them. Here we describe a new approach to generating waveforms for QMFs. Instead of scanning the amplitude of a sine wave to measure the m/z spectrum, the frequency of a trapezoidal wave is digitally scanned. A synchronous, narrow-range (<0.2%) amplitude scan overlays the frequency scan to improve the sampling resolution. Because the frequency is the primary quantity that is scanned, there is, in principle, no upper m/z limit. The frequency signal is constructed from a stabilized base clock using a field programmable gate array. This signal drives integrating amplifiers which generate the trapezoidal waves. For a trapezoidal wave the harmonics can be minimized by selecting the appropriate rise and fall times. To achieve a high resolving power, the digital signal has low jitter, and the trapezoidal waveform is generated with high fidelity. The QMF was characterized with cesium iodide clusters. Singly and multiply charged clusters with z up to +5 were observed. A resolving power of ∼1200 (FWHM) was demonstrated over a broad m/z range. Resolution was lost above 20 000 Th, partly because of congestion due to overlapping multiply charged clusters. Ions were observed for m/z values well in excess of 150 000 Th.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-synchronized continuous wave laser-induced fluorescence on an oscillatory xenon discharge

A novel approach to time-synchronizing laser-induced fluorescence measurements to an oscillating current in a 60 Hz xenon discharge lamp using a continuous wave laser is presented. A sample-hold circuit is implemented to separate out signals at different phases along a current cycle, and is followed by a lock-in amplifier to pull out the resulting time-synchronized fluorescence trace from the large background signal. The time evolution of lower state population is derived from the changes in intensity of the fluorescence excitation line shape resulting from laser-induced fluorescence measurements of the 6s{sup Prime }[1/2]{sub 1}{sup 0}-6p{sup Prime }[3/2]{sub 2} xenon atomic transition at {lambda}= 834.68 nm. Results show that the lower state population oscillates at twice the frequency of the discharge current, 120 Hz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

Switch-like reprogramming of gene expression after fusion of multinucleate plasmodial cells of two Physarum polycephalum sporulation mutants

Highlights: •We investigate reprogramming of gene expression in multinucleate single cells. •Cells of two differentiation control mutants are fused. •Fused cells proceed to alternative gene expression patterns. •The population of nuclei damps stochastic fluctuations in gene expression. •Dynamic processes of cellular reprogramming can be observed by repeated sampling of a cell. -- Abstract: Nonlinear dynamic processes involving the differential regulation of transcription factors are considered to impact the reprogramming of stem cells, germ cells, and somatic cells. Here, we fused two multinucleate plasmodial cells of Physarum polycephalum mutants defective in different sporulation control genes while being in different physiological states. The resulting heterokaryons established one of two significantly different expression patterns of marker genes while the plasmodial halves that were fused to each other synchronized spontaneously. Spontaneous synchronization suggests that switch-like control mechanisms spread over and finally control the entire plasmodium as a result of cytoplasmic mixing. Regulatory molecules due to the large volume of the vigorously streaming cytoplasm will define concentrations in acting on the population of nuclei and in the global setting of switches. Mixing of a large cytoplasmic volume is expected to damp stochasticity when individual nuclei deliver certain RNAs at low copy number into the cytoplasm. We conclude that spontaneous synchronization, the damping of molecular noise in gene expression by the large cytoplasmic volume, and the option to take multiple macroscopic samples from the same plasmodium provide unique options for studying the dynamics of cellular reprogramming at the single cell level.

60 APPLIED LIFE SCIENCES↗

A Method for Dynamic Kolsky Bar Compression at High Temperatures: Application to Ti-6Al-4V

Abstract An experimental apparatus for measuring the dynamic behavior of materials subjected to strain rates on the order of 10 $$^3$$ 3 s $$^{-1}$$ - 1 and temperatures up to 800°C with a unique triple actuation system is developed in this work. This system is based on the traditional Kolsky (or split-Hopkinson pressure) bar design, with the addition of an external furnace used to heat the specimen to the desired temperature. A synchronized triple pneumatic actuation system is used to control the motion and timing of the the sample, incident, and transmitted bars. The cold contact time (CCT), or the time during which the heated sample is in contact with the room temperature bars before compression, is measured experimentally and carefully controlled to minimize the development of a temperature gradient across the sample and avoid heating of the bars. Experiments are performed in conjunction with ultra high speed imaging and 2D digital image correlation (DIC), as well as high speed thermal imaging. To verify the viability of the proposed system, experiments were conducted on Ti-6Al-4V (wt.%) at temperatures from 25°C up to and 800°C at an average strain rate of approximately 1200 s $$^{-1}$$ - 1 .

36 MATERIALS SCIENCE↗

New contactless method for thermal diffusivity measurements using modulated photothermal radiometry

Modulated photothermal radiometry is a non-destructive and contactless technique for the characterization of materials. It has two major advantages: a good signal-to-noise ratio through a synchronous detection and a low dependence on the heating power and the optical properties of the sample surface. This paper presents a new method for characterizing the thermal diffusivity of a material when the phase shift between a modulated laser power signal and the thermal signal of a plate sample is known at different frequencies. The method is based on a three-dimensional analytical model which is used to determine the temperature amplitude and the phase in the laser heating of the plate. A new simple formula was developed through multi-parametric analysis to determine the thermal diffusivity of the plate with knowledge of the frequency at the minimum phase shift, the laser beam radius r{sub 0} and the sample thickness L. This method was developed to control the variation of the thermal diffusivity of nuclear components and it was first applied to determine the thermal diffusivity of different metals: 304 L stainless steel, nickel, titanium, tungsten, molybdenum, zinc, and iron. The experimental results were obtained with 5%–10% accuracy and corresponded well with the reference values. The present paper also demonstrates the limit of application of this method for plate with thickness r{sub 0}/100 ≤ L ≤ r{sub 0}/2. The technique is deemed interesting for the characterization of barely accessible components that require a contactless measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resampling technique to correct for the Doppler effect in a search for gravitational waves

The frequency of any gravitational-wave signal received from a spinning neutron star will appear Doppler-shifted by the Earth's rotation and orbital motion. This frequency shift must be compensated to recover the signal energy as a spectral monochromatic peak with a high signal-to-noise ratio. Generally the correction depends on the source's position in the sky, spin, and spin-down rate. Here we propose a method of applying a single correction to the data which is valid for all the emission frequencies at a fixed position in the sky and for a given spin-down rate. We advance or retard the antenna proper time by removing (or repeating) single samples of the digitized output signal to keep the effective receiver and source clocks in accurate synchronization. The method, which requires just a few lines of code and little computational effort, appears to be very effective for ''semitargeted'' searches, where the source direction is known but the emission frequency is not.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of coherent optical phonons excited by femtosecond laser radiation in Sb films by ultrafast electron diffraction method

The generation of coherent optical phonons in a polycrystalline antimony film sample has been investigated using femtosecond electron diffraction method. Phonon vibrations have been induced in the Sb sample by the main harmonic of a femtosecond Ti:Sa laser (λ = 800 nm) and probed by a pulsed ultrashort photoelectron beam synchronized with the pump laser. The diffraction patterns recorded at different times relative to the pump laser pulse display oscillations of electron diffraction intensity corresponding to the frequencies of vibrations of optical phonons: totally symmetric (A{sub 1g}) and twofold degenerate (E{sub g}) phonon modes. The frequencies that correspond to combinations of these phonon modes in the Sb sample have also been experimentally observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Terahertz radiation as a bunch diagnostic for laser-wakefield-accelerated electron bunches

Experimental results are reported from two measurement techniques (semiconductor switching and electro-optic sampling) that allow temporal characterization of electron bunches produced by a laser-driven plasma-based accelerator. As femtosecond electron bunches exit the plasma-vacuum interface, coherent transition radiation (at THz frequencies) is emitted. Measuring the properties of this radiation allows characterization of the electron bunches. Theoretical work on the emission mechanism is presented, including a model that calculates the THz wave form from a given bunch profile. It is found that the spectrum of the THz pulse is coherent up to the 200 {micro}m thick crystal (ZnTe) detection limit of 4 THz, which corresponds to the production of sub-50 fs (rms) electron bunch structure. The measurements demonstrate both the shot-to-shot stability of bunch parameters that are critical to THz emission (such as total charge and bunch length), as well as femtosecond synchronization among bunch, THz pulse, and laser beam.

43 PARTICLE ACCELERATORS↗

Aerosol Synthesis of Highly Dispersed Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+} Phosphor with Intense Photoluminescence

A simple method of pyrolysis of an aerosol solution of yttrium, aluminum, and cerium nitrates with the addition of urea or citric acid, followed by brief annealing, is developed to obtain a highly dispersed aluminum–yttrium garnet powder that demonstrates intense photoluminescence in the visible light region. Characterization of the synthesized samples (photoluminescence spectra, X-ray diffraction analysis, Raman spectra) showed that intense photoluminescence is achieved only in a narrow window of process conditions, namely, the concentration of nitrate solution and the concentration of citric acid or urea. The photoluminescence intensity increases upon annealing synchronously with an increase in the crystallite size, which, along with the optimal cerium concentration (~0.5 at %), is a determining factor for obtaining high-quality samples. The synthesized powders had intense photoluminescence and high optical perfection, as evidenced by the observation of whispering gallery modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Star Formation Histories from Spectral Energy Distributions and Color–magnitude Diagrams Agree: Evidence for Synchronized Star Formation in Local Volume Dwarf Galaxies over the Past 3 Gyr

Star formation histories (SFHs) reveal physical processes that influence how galaxies form their stellar mass. We compare the SFHs of a sample of 36 nearby (D ≲ 4 Mpc) dwarf galaxies from the ACS Nearby Galaxy Survey Treasury (ANGST), inferred from the color–magnitude diagrams (CMDs) of individually resolved stars in these galaxies, with those reconstructed by broadband spectral energy distribution (SED) fitting using the dense basis SED-fitting code. When comparing individual SFHs, we introduce metrics for evaluating SFH reconstruction techniques. For both the SED and CMD methods, the median normalized SFH of galaxies in the sample shows a period of quiescence at lookback times of 3–6 Gyr followed by rejuvenated star formation over the past 3 Gyr that remains active until the present day. To determine if these represent special epochs of star formation in the D <4 Mpc portion of the Local Volume, we break this ANGST dwarf galaxy sample into subsets based on specific star formation rate and spatial location. Modulo offsets between the methods of about 1 Gyr, all subsets show significant decreases and increases in their median normalized SFHs at the same epochs, and the majority of the individual galaxy SFHs are consistent with these trends. These results motivate further study of potential synchronized star formation quiescence and rejuvenation in the Local Volume as well as development of a hybrid method of SFH reconstruction that combines CMDs and SEDs, which have complementary systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray diffraction in the pulsed laser heated diamond anvil cell

We have developed in situ x-ray synchrotron diffraction measurements of samples heated by a pulsed laser in the diamond anvil cell at pressure up to 60 GPa. We used an electronically modulated 2-10 kHz repetition rate, 1064-1075 nm fiber laser with 1-100 {micro}s pulse width synchronized with a gated x-ray detector (Pilatus) and time-resolved radiometric temperature measurements. This enables the time domain measurements as a function of temperature in a microsecond time scale (averaged over many events, typically more than 10,000). X-ray diffraction data, temperature measurements, and finite element calculations with realistic geometric and thermochemical parameters show that in the present experimental configuration, samples 4 {micro}m thick can be continuously temperature monitored (up to 3000 K in our experiments) with the same level of axial and radial temperature uniformities as with continuous heating. We find that this novel technique offers a new and convenient way of fine tuning the maximum sample temperature by changing the pulse width of the laser. This delicate control, which may also prevent chemical reactivity and diffusion, enables accurate measurement of melting curves, phase changes, and thermal equations of state.

43 PARTICLE ACCELERATORS↗

Thermoreflectance temperature measurement with millimeter wave

GigaHertz (GHz) thermoreflectance technique is developed to measure the transient temperature of metal and semiconductor materials located behind an opaque surface. The principle is based on the synchronous detection, using a commercial THz pyrometer, of a modulated millimeter wave (at 110 GHz) reflected by the sample hidden behind a shield layer. Measurements were performed on aluminum, copper, and silicon bulks hidden by a 5 cm thick Teflon plate. We report the first measurement of the thermoreflectance coefficient which exhibits a value 100 times higher at 2.8 mm radiation than those measured at visible wavelengths for both metallic and semiconductor materials. This giant thermoreflectance coefficient κ, close to 10{sup −3} K{sup −1} versus 10{sup −5} K{sup −1} for the visible domain, is very promising for future thermoreflectance applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COVID-19-associated school closures and related efforts to sustain education and subsidized meal programs, United States, February 18-June 30, 2020

Pre-emptive school closures are frontline community mitigation measures recommended by the US Centers for Disease Control and Prevention (CDC) for implementation during severe pandemics. This study describes the spatiotemporal patterns of publicly announced school closures implemented in response to the coronavirus disease 2019 (COVID-19) pandemic and assesses how public K-12 districts adjusted their methods of education delivery and provision of subsidized meals. During February 18–June 30, 2020, we used daily systematic media searches to identify publicly announced COVID-19–related school closures lasting ≥1 day in the United States (US). We also collected statewide school closure policies from state government websites. Data on distance learning and subsidized meal programs were collected from a stratified sample of 600 school districts. The first COVID-19–associated school closure occurred on February 27, 2020 in Washington state. By March 30, 2020, all but one US public school districts were closed, representing the first-ever nearly synchronous nationwide closure of public K-12 schools in the US. Approximately 100,000 public schools were closed for ≥8 weeks because of COVID-19, affecting >50 million K-12 students. Of 600 districts sampled, the vast majority offered distance learning (91.0%) and continued provision of subsidized meal programs (78.8%) during the closures. Despite the sudden and prolonged nature of COVID-19–associated school closures, schools demonstrated flexibility by implementing distance learning and alternate methods to continue subsidized meal programs.

60 APPLIED LIFE SCIENCES↗

The evolution of solid density within a thermal explosion II. Dynamic proton radiography of cracking and solid consumption by burning

We report proton transmission images obtained subsequent to the laser assisted thermal ignition of a sample of PBX 9501 (a plastic bonded formulation of the explosive nitramine octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)). We describe the laser assisted thermal ignition technique as a means to synchronize a non-linear thermal ignition event while preserving the subsequent post-ignition behavior. We have obtained dynamic proton transmission images at two spatial magnifications and viewed both the radial and transverse axis of a solid cylindrical sample encased in aluminum. Images have been obtained with 3 to 15 {mu}s temporal resolution and approximately 100 {mu}m spatial resolution at the higher magnification. We observe case expansion from very early in the experiment, until case fragmentation. We observe spatially anisotropic features in the transmission which we attribute to cracking in the solid explosive, in agreement with previous measurements conducted on two dimensional samples with optical viewing. Digital analysis of the images also reveals spatially isotropic features which we attribute to the evolution of the loss of density by burning subsequent to thermal ignition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated High-Speed Microstructural Characterization Method Using Simultaneous XRD, Stereo-DIC, and PCI

High-speed characterization of the deformation mechanisms in polycrystalline metals requires the quantification of full strain fields and local microstructural evolutions simultaneously. In this paper, we present a novel experimental method to integrate phase-contrast imaging (PCI), stereographic digital image correlation (stereo-DIC), and full-ring X-ray diffraction (XRD) to allow for the simultaneous characterization of polycrystalline metals at 1MHz or higher. A Kolsky bar was integrated into the synchrotron X-ray source in Sector 32 ID-B at the Advance Photon Source (APS) at Argonne National Laboratory. When the sample is dynamically loaded, the diagnostic methods of full-ring XRD, PCI, and stereo-DIC are properly synchronized to record the deformation behavior at both continuum and microstructural scales as a function of the loading history. An advanced high-strength steel (AHSS) is used as a model material to demonstrate the capabilities of this new experimental method.

36 MATERIALS SCIENCE↗

Developmental programming: Prenatal BPA treatment disrupts timing of LH surge and ovarian follicular wave dynamics in adult sheep

Developmental exposure to BPA adversely affects reproductive function. In sheep, prenatal BPA treatment induces reproductive neuroendocrine defects, manifested as LH excess and dampened LH surge and perturbs early ovarian gene expression. In this study we hypothesized that prenatal BPA treatment will also disrupt ovarian follicular dynamics. Pregnant sheep were treated from days 30 to 90 of gestation with 3 different BPA doses (0.05, 0.5, or 5 mg/kg BW/day). All female offspring were estrus synchronized and transrectal ultrasonography was performed daily for 22 days to monitor ovarian follicular and corpora lutea dynamics. Blood samples were collected to assess preovulatory hormonal changes and luteal progesterone dynamics. Statistical analysis revealed that the time interval between the estradiol rise and the preovulatory LH surge was shortened in the BPA-treated females. None of the three BPA doses had an effect on corpora lutea, progestogenic cycles, and mean number or duration of ovulatory and non-ovulatory follicles. However, differences in follicular count trajectories were evident in all three follicular size classes (2–3 mm, 4–5 mm, and ≥ 6 mm) of prenatal BPA-treated animals compared to controls. Number of follicular waves tended also to be more variable in the prenatal BPA-treated groups ranging from 2 to 5 follicular waves per cycle, while this was restricted to 3 to 4 waves in control females. These changes in ovarian follicular dynamics coupled with defects in time interval between estradiol rise and preovulatory LH release are likely to lead to subfertility in prenatal BPA-treated females. - Highlights: • Prenatal BPA shortens interval between estradiol rise and preovulatory LH surge. • Prenatal BPA affects follicular count trajectory and follicular wave occurrence. • Prenatal BPA does not affect ovulatory rate and progesterone dynamics.

60 APPLIED LIFE SCIENCES↗