Search NASASearch

SEARCH · Search NASA

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurement of Local Impedance Characteristics of In-Plane PEM Electrolyzer Component Features via Segmented Cell

Segmented cells are a class of advanced diagnostic devices that enable the measurement of current distribution within the active area of an electrochemical cell, allowing for the evaluation of localized impacts from operating conditions, flow fields and component inhomogeneities. Segmented cell devices have been applied to support R&D efforts for the advancement of polymer electrolyte membrane fuel cell technologies and more recently proton exchange membrane water electrolysis (PEMWE). Beyond current density distributions, segmented cells have been successfully deployed to collect the distribution of other relevant parameters such as high frequency resistance and electrode potentials. Very recently, a promising impedance method has been reported for water electrolysis where a one-dimensional segmented cell is coupled to a multichannel potentiostat, to enable the measurement of local cell impedances, further expanding the diagnostic capabilities of the segmented cell. In this study, we will present recent efforts to accurately measure local impedance characteristics for a PEMWE cell using a two-dimensional segmented cell device coupled with a multichannel potentiostat. The distribution of local resistances, i.e. high frequency, charge transfer, mass transport and catalyst layer, and iR-free overpotentials were successfully measured after eliminating sources of random and systematic error. We will discuss the application of this diagnostic on a cell containing a 1 cm feature simulating an ionomer skin. The results from these tests give insights if such an irregularity needs to be classified as a defect, and highlight the usefulness of coupling impedance spectroscopy with segmented cells for holistic spatial diagnostics of electrochemical devices.

08 HYDROGEN

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Cosmological Constraints from Combining Photometric Galaxy Surveys and Gravitational Wave Observatories

Spatial variations in survey properties due to selection effects generate substantial systematic errors in large-scale structure measurements in optical galaxy surveys on very large scales. On such scales, the statistical sensitivity of optical surveys is also limited by their finite sky coverage. By contrast, gravitational wave (GW) sources appear to be relatively free of these issues, provided the angular sensitivity of GW experiments can be accurately characterized. We quantify the expected cosmological information gain from combining the forecast LSST 3$\times$2pt analysis (combination of three 2-point correlations of galaxy density and weak lensing shear fields) with the large-scale auto-correlation of GW sources from proposed next-generation GW experiments. We find that in $\Lambda$CDM and $w$CDM models, there is no significant improvement in cosmological constraints from combining GW with LSST 3$\times$2pt over LSST alone, due to the large shot noise for the former; however, this combination does enable a $\sim6\%$ constraint on the linear galaxy bias of GW sources. More interestingly, the optical-GW data combination provides tight constraints on models with primordial non-Gaussianity (PNG), due to the predicted scale-dependent bias in PNG models on large scales. Assuming that the largest angular scales that LSST will probe are comparable to those in Stage III surveys ($\ell_{\rm min}\sim50$), the inclusion of next-generation GW measurements could improve constraints on the PNG parameter $f_{\rm NL}$ by up to a factor of $\simeq6.6$ compared to LSST alone, yielding $\sigma(f_{\rm NL})=8.5$. These results assume the expected capability of a network of Einstein Telescope-like GW observatories, with a detection rate of $10^6$ events/year. We investigate the sensitivity of our results to different assumptions about future GW detectors as well as different LSST analysis choices.

79 ASTRONOMY AND ASTROPHYSICS

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics

The Principle of Maximum Conformality Correctly Resolves the Renormalization-Scheme-Dependence Problem

In this paper, we clarify a serious misinterpretation and consequent misuse of the Principle of Maximum Conformality (PMC), which also can serve as a mini-review of PMC. In a recently published article, P. M. Stevenson has claimed that “the PMC is ineffective and does nothing to resolve the renormalization-scheme-dependence problem”, concluding incorrectly that the success of PMC predictions is due to the PMC being a “laborious, ad hoc, and back-door” version of the Principle of Minimal Sensitivity (PMS). We show that such conclusions are incorrect, deriving from a misinterpretation of the PMC and an overestimation of the applicability of the PMS. The purpose of the PMC is to achieve precise fixed-order pQCD predictions, free from conventional renormalization schemes and scale ambiguities. We demonstrate that the PMC predictions satisfy all the self-consistency conditions of the renormalization group and standard renormalization-group invariance; the PMC predictions are thus independent of any initial choice of renormalization scheme and scale. The scheme independence of the PMC is also ensured by commensurate scale relations, which relate different observables to each other. Moreover, in the Abelian limit, the PMC dovetails into the well-known Gell-Mann–Low framework, a method universally revered for its precision in QED calculations. Due to the elimination of factorially divergent renormalon terms, the PMC series not only attains a convergence behavior far superior to that of its conventional counterparts but also deftly curtails any residual scale dependence caused by the unknown higher-order terms. This refined convergence, coupled with its robust suppression of residual uncertainties, furnishes a sound and reliable foundation for estimating the contributions from unknown higher-order terms. Anchored in the bedrock of standard renormalization-group invariance, the PMC simultaneously eradicates the factorial divergences and eliminates superfluous systematic errors, which inversely provides a good foundation for achieving high-precision pQCD predictions. Consequently, owing to its rigorous theoretical underpinnings, the PMC is eminently applicable to virtually all high-energy hadronic processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

A Measurement of the Largest-scale CMB E -mode Polarization with CLASS

We present measurements of large-scale cosmic microwave background E-mode polarization from the Cosmology Large Angular Scale Surveyor 90 GHz data. Using 115 det-yr of observations collected through 2024 with a variable-delay polarization modulator, we achieved a polarization sensitivity of 82 μK arcimin, comparable to Planck at similar frequencies (100 and 143 GHz ). The analysis demonstrates effective mitigation of systematic errors and addresses challenges to large-angular-scale power recovery posed by time-domain filtering in maximum-likelihood map-making. A novel implementation of the pixel-space transfer matrix is introduced, which enables efficient filtering simulations and bias correction in the power spectrum using the quadratic cross-spectrum estimator. Overall, we achieved an unbiased time-domain filtering correction to recover the largest angular scale polarization, with the only power deficit, arising from map-making nonlinearity, being characterized as <3%. Through cross-correlation with Planck, we detected the cosmic reionization at 99.4% significance and measured the reionization optical depth τ = $0.053^{+0.018}_{-0.019}$, marking the first ground-based attempt at such a measurement. At intermediate angular scales (ℓ > 30), our results, both independently and in cross-correlation with Planck, remain fully consistent with Planck’s measurements.

79 ASTRONOMY AND ASTROPHYSICS

The Simons Observatory: Design, Integration, and Testing of the Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of σ(r) = 0.002, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35° field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and <0.1 K focal plane that holds >12,000 transition edge sensor detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The Dark Energy Survey: Cosmology Results with ∼1500 New High-redshift Type Ia Supernovae Using the Full 5 yr Data Set

Abstract We present cosmological constraints from the sample of Type Ia supernovae (SNe Ia) discovered and measured during the full 5 yr of the Dark Energy Survey (DES) SN program. In contrast to most previous cosmological samples, in which SNe are classified based on their spectra, we classify the DES SNe using a machine learning algorithm applied to their light curves in four photometric bands. Spectroscopic redshifts are acquired from a dedicated follow-up survey of the host galaxies. After accounting for the likelihood of each SN being an SN Ia, we find 1635 DES SNe in the redshift range 0.10 < z < 1.13 that pass quality selection criteria sufficient to constrain cosmological parameters. This quintuples the number of high-quality z > 0.5 SNe compared to the previous leading compilation of Pantheon+ and results in the tightest cosmological constraints achieved by any SN data set to date. To derive cosmological constraints, we combine the DES SN data with a high-quality external low-redshift sample consisting of 194 SNe Ia spanning 0.025 < z < 0.10. Using SN data alone and including systematic uncertainties, we find Ω M = 0.352 ± 0.017 in flat ΛCDM. SN data alone now require acceleration ( q 0 < 0 in ΛCDM) with over 5 σ confidence. We find ( Ω M , w ) = ( 0.264 − 0.096 + 0.074 , − 0.80 − 0.16 + 0.14 ) in flat w CDM. For flat w 0 w a CDM, we find ( Ω M , w 0 , w a ) = ( 0.495 − 0.043 + 0.033 , − 0.36 − 0.30 + 0.36 , − 8.8 − 4.5 + 3.7 ) , consistent with a constant equation of state to within ∼2 σ . Including Planck cosmic microwave background, Sloan Digital Sky Survey baryon acoustic oscillation, and DES 3 × 2pt data gives (Ω M , w ) = (0.321 ± 0.007, −0.941 ± 0.026). In all cases, dark energy is consistent with a cosmological constant to within ∼2 σ . Systematic errors on cosmological parameters are subdominant compared to statistical errors; these results thus pave the way for future photometrically classified SN analyses.

79 ASTRONOMY AND ASTROPHYSICS

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS

Bias correcting regional scale Earth system model projections: novel approach using empirical mode decomposition

Bias correction is a crucial step in using Earth system model outputs for assessments, as it adjusts systematic errors by comparing the model to observations. However, standard methods – ranging from mean-based linear scaling to distribution-based quantile mapping typically treat bias correction as a single-scale process, overlooking the fact that biases can manifest differently across daily, seasonal, and annual timescales. In this study, we propose a novel, timescale-aware bias-correction approach built on Empirical Mode Decomposition. By decomposing the meteorological signal into multiple oscillatory components and aggregating them to represent distinct timescales, we apply targeted corrections to each component, thereby preserving both short- and long-term structure in the data. Experimental illustrations show that the timescale-aware EMDBC framework matches the performance of conventional quantile-delta mapping (QDM) at the native daily scale and achieves progressively larger bias reductions at bi-weekly, seasonal, and annual scales. As a result, the proposed approach offers a more robust path to accurate and reliable Earth system projections, strengthening their utility for resilience and adaptation planning.

Ganguli, Arkaprabha [Argonne National Laboratory (

Characterizing Supernovae Neutrinos in MARLEY

This summer I worked on characterizing the uncertainties in neutrino-argon interactions due to the optical model potential. Functionally, this was a great deal of new experience coding in C++. I wrote a script using MARLEY(Gardiner 2019) to compute both the branching ratios and exclusive cross sections for a whole host of different decay processes from the unstable Potassium nucleus created by a v+Ar charged current interaction. These decays were computed through MARLEY, governed by a global parametrization of the Optical Model potential(Koning-Delaroche 2003). Helpfully, Pruitt+ 2023 provided public supplemental material outlining 400 separate "universes" for the optical model potential parameters. These "universes" represent uncertainties on the optical potential itself, and I wrote code to incorporate them into the MARLEY framework and quantify their impact on the predictions of neutrino-argon cross sections. This stands as the first computation of nuclear de-excitation systematic errors on cross sections in this energy band for v+Ar interactions, a critical step to understanding the science we can do with DUNE in the tens-of-MeV band.

Abu El-Haj, Luca

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand’s Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the fundamental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scattering provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon's internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (GMn) to unprecedented Q2 using Durand's method, also known as the "ratio" method. Systematic errors are greatly reduced by ext

Datta, Provakar

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar

Identification of the Liquid Argon Scattering Experimental Discrepancies Using Simulation

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Proton Assembly Building at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS’s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced photo multiplier. With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.; Fermilab]