Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluating Non-Fluoropolymer-Based Co-Extruded Backsheets Using Combined-Accelerated Stress Testing and Materials Forensics

Co-extruded, non-fluoropolymer backsheet films for photovoltaic (PV) modules have gained popularity in recent years based on their cost competitiveness. However, their viability has been thrown into question as a result of widespread, early-life field-failures of some materials, particularly the polyamide (PA)-based “AAA” backsheet product. Failure to detect weaknesses in those earlier products could be due, in part, to insufficient quality testing practices. New testing protocols have recently been developed to better evaluate such materials. Here we show the testing results for a non-fluoropolymer, co-extruded PA-based backsheet film, which demonstrates greater durability than AAA and some commercial fluoropolymers. Using material characterization techniques including Fourier-transform infrared spectroscopy (FTIR), wide-angle x-ray scattering (WAXS), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), elongation-to-break (ETB), and optical microscopy we perform a comprehensive failure analysis to better understand the materials weaknesses. This analysis can ultimately inform how best to improve the material and extend its lifetime. This work serves as a demonstration that some materials should not be discounted due to a single poorly designed product and that more appropriate qualification testing with subsequent materials analysis can be used to develop better materials.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Protocol for Screening Water Oxidation or Reduction Electrocatalyst Activity in a Three-Electrode Cell for Alkaline Exchange Membrane Electrolysis

Accurate and reproducible screening of the electrocatalytic activity of novel materials for Oxygen Evolution Reaction (OER) and Hydrogen Evolution Reaction (HER) requires establishing an easily adoptable harmonized testing protocol. Herein, we describe a robust, instrumentation-independent testing technique utilizing a three-electrode cell with a fully immersed working electrode. Compared to rotating disk electrode (RDE) techniques, this protocol produces current densities close to those obtained in real electrolyzers and eliminates the usage of the expensive RDE apparatus.

08 HYDROGEN↗

Launching a saliva-based SARS-CoV-2 surveillance testing program on a university campus

Regular surveillance testing of asymptomatic individuals for SARS-CoV-2 has been center to SARS-CoV-2 outbreak prevention on college and university campuses. Here we describe the voluntary saliva testing program instituted at the University of California, Berkeley during an early period of the SARS-CoV-2 pandemic in 2020. The program was administered as a research study ahead of clinical implementation, enabling us to launch surveillance testing while continuing to optimize the assay. Results of both the testing protocol itself and the study participants’ experience show how the program succeeded in providing routine, robust testing capable of contributing to outbreak prevention within a campus community and offer strategies for encouraging participation and a sense of civic responsibility.

59 BASIC BIOLOGICAL SCIENCES↗

Active and Durable PGM-free Cathodic Electrocatalysts for Fuel Cell Application

Platinum Group Metal-free (PGM-free) Oxygen Reduction Reaction (ORR) electrocatalysts possess high intrinsic activity measured by a Rotating Disk Electrode (RDE) method. However, under fuel cell operating conditions, PGM-free ORR electrocatalysts have underperformed compared to platinum catalysts. PGM-free ORR electrocatalyst’s fuel cell performance can be improved by designing and optimizing the cathodic catalyst layer (CL) and Membrane Electrode Assembly (MEA) construction such that: 1) it efficiently provides oxygen access to ORR active sites (through catalyst morphology control); 2) it removes water from the CL (by tuning the hydrophobicity of the PGM-free catalysts and the catalyst layer structure); and 3) it increases proton conductivity (by homogeneous mixing of catalysts and ionomer). Studying the CL is complex due to the absence of well-established protocols of MEA activation, especially compared to platinum-containing catalysts. PGM-free fuel cell testing protocols would need to optimize potentiostatic vs galvanostatic measurements, scan rates, parameters of Electrochemical Impedance Spectroscopy (EIS) and Beginning of Experiment (BOE) criteria. To make the PGM-free catalyst’s fuel cell performance comparable to platinum, the synergistic effort of materials design, fine tuning of the catalyst layer and comprehensive electrochemical analysis is required.

08 HYDROGEN↗

Influence of Combustion Gas Temperatures on Piston Deposits for Diesel and Ammonia Dual-Fuel Combustion

As new fuels are adopted for marine engines, it is necessary to understand their impact on lubricant performance. In order to evaluate the performance of existing lubricants and inform the development of new ones, a deposit control test protocol has been developed using the ExxonMobil Enterprise two-stroke marine diesel research engine. Repeated tests at the target speed/load operating condition but different thermal conditions show that the temperature of the combustion gases is a key driver in the formation of deposits on piston surfaces, impacting both the quantity of deposits and whether they are hard or gummy. These impacts are examined for diesel combustion as well as ammonia dual-fuel combustion. Among alternative marine fuels, ammonia has perhaps the most unanswered questions regarding interactions with cylinder lubricants. The influence of ammonia dual-fuel combustion on the thermal conditions experienced by the lubricant are discussed. Scrape down oil samples were collected after operation with ammonia for analysis and comparison with fresh oil. Chemical analysis using a GC/MS instrument did not show significant permanent chemical changes in the lubricant due to ammonia exposure.

Kaul, Brian [ORNL] (ORCID:0000000184813620)↗

Federal Emergency Management Agency Mobile Housing Unit Running Gear Testing (Final Report)

The Federal Emergency Management Agency (FEMA) stages manufactured housing units (MHUs) at key locations to be used during disasters when other housing accommodations cannot be arranged for individuals or families. Due to the unpredictability of natural disasters and the limitations of the manufactured housing industry to produce large numbers of MHUs in very short periods of time, it is necessary for FEMA to store a large number of units for many months or years. With these long storage periods come degradation issues with frames, tires, bearing, and braking systems. These types of issues are also of interest to the U.S. Department of Transportation (DOT) Federal Motor Carrier Safety Administration (FMCSA) because regulated carriers normally transport these units and 49 CFR 393.75 Tires specifies tire loading restrictions for manufactured homes. To compare the running gear (tires, brakes, drums, bearings, axles, springs, and spring mounting hardware) currently specified in the 2014 Rugged Based Performance Requirements (RBPR) and the newly recommended running gear specified in the upcoming revision to the RBPR, the Oak Ridge National Laboratory (ORNL) outlined a Longevity Test Plan, which focused on the assessment of component longevity (failure rates by component type). The Test Plan also studied the forces imparted to the MHU from the running gear from interaction with the roadway for both the running gear in the 2014 RBPR and the running gear specified in the upcoming RBPR revision. Since the assessment of component longevity and failures are also issues of concern for FMCSA, both agencies collaborated to support the research presented in this report. The tests and data collection were conducted at the Navistar Proving Grounds (NPG) in New Carlisle (near South Bend), Indiana, during the May-November 2018 period. Four alternatives for the suspension system of a typical three-bedroom MHU were considered in this test. Alternative 0 was the MHU that was selected from the FEMA staging area in Selma, Alabama. Empirical data had shown that, on average, this alternative experiences one tire failure every 150 miles (or 0.0067 tire failures per mile traveled). Before testing, Alternative 0 was equipped with similar running gear hardware, although in new condition and installed following the manufacturer’s specifications. This became the Baseline Unit, or Alternative 1. Another unit, also selected from the FEMA staging area in Selma, Alabama, was equipped with better axles (i.e., axles that were rated for 7,000lbs as opposed to 6,000lbs for the Baseline Unit) and better tires. This became the Upgrade Unit, or Alternative 2. At the end of the Longevity Test, the Upgrade Unit was mounted with radial tires. This became Alternative 3.Alternative 1 (Baseline Unit) had, on average, one tire failure every 251 miles (or 0.0040 tire failures per mile traveled). So, by simply following the correct manufacturer’s specifications for the assembly of the transportation system, a reduction of 41% in the per mile tire failure was achieved. In the same test, Alternative 2 (Upgrade Unit) showed, on average, one tire failure every 728 miles traveled (or 0.0014 tire failure s per mile traveled). When the Upgrade Unit was mounted with radial tires in the last part of the test, no tire failures were observed for the 2,400 miles tested. That is, in the case of the radial tires (Alternative 3) the tire failure was less than one per 2,400 miles traveled (or less than 0.0004 tire failures per mile traveled). The data collected for the Longevity Test showed that the maximum accelerations were registered in all cases at the center of the MHU in the vertical direction. The overall maximum was registered by the Baseline Unit, Alternative 1. If that value is normalized to 100%, then the Upgrade Unit (Alternative 2) showed, on average, 81% at the same location, and Alternative 3 (radial-tire test) 59%. That is, the upgraded transportation system showed a reduction of 19% and 41% in the vertical accelerations transmitted to MHU at its center when regular and radial tires, respectively, were used. As part of the Test Protocol, NPG conducted a visual inspection of the MHUs and transportation system at the end of each test day. ORNL reviewed all the inspection reports in an attempt to determine if there was any difference in the damage that the Baseline and Upgrade MHUs showed during the test. The Upgrade Unit always showed lower accelerations transmitted to the MHU than the Baseline Unit. In most cases, these differences were statistically significant. The FEMA inspection report, conducted by a FEMA certified inspector at the end of the tests, included a shorter list of damaged items for the Baseline Unit than for the Upgrade Unit, although similar type of damages was described for both units. This may be an indication that, although lower than those of the Baseline Unit, the accelerations transmitted by the Upgrade Unit were above the threshold at which MHU elements start to fail.

42 ENGINEERING↗

Conductivity and Transference Number Determination Protocols for Solid Oxide Cell Materials

To standardize materials and component characterization for next generation hydrogen production and energy generation solid oxide cell (SOC) technologies, test protocols are being established to facilitate comparison across the numerous laboratories and research institutions where SOC development for application in solid oxide fuel cells (SOFCs) and solid oxide electrolyzes cells (SOEC) is conducted. This paper proposes guiding protocols for fundamental electrical properties characterization of SOC materials, including temperature- and oxygen partial pressure (pO 2 )-dependent conductivity measurements, and use of the electromotive force for determining the transference numbers, or contributions of each charge carrier (i.e., ions and electrons), to the total conductivity. The protocol for Archimedes density measurements is also provided as an integral technique to both of these methods.

25 ENERGY STORAGE↗

Effects of catholyte aging on high-nickel NMC cathodes in sulfide all-solid-state batteries

Sulfide solid-state electrolytes (SSEs) in all-solid-state batteries (SSBs) are recognized for their high ionic conductivity and inherent safety. The LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) cathode offers a high thermodynamic potential of approximately 3.8 V vs. Li/Li + and a theoretical specific capacity of 200 mA h g −1 . However, the practical utilization of NMC811 in sulfide SSBs faces significant interfacial challenges. The oxidation instability of sulfide solid electrolytes against NMC811 and the formation of the cathode electrolyte interphase (CEI) during cycling lead to degradation and reduced cell performance. Volumetric changes in NMC during lithiation and de-lithiation can also cause detachment from sulfide electrolytes or internal particle cracking. Despite extensive galvanostatic cycling studies to address the issues, the calendar life of sulfide SSBs remains poorly understood. Here, we systematically studied the effects of four different catholytes on the calendar aging of LiNbO 3 (LNO)-coated NMC811, including Li 6 PS 5 Cl (LPSCl), Li 3 InCl 6 –Li 6 PS 5 Cl (LIC–LPSCl), Li 3 YCl 6 –Li 6 PS 5 Cl (LYC–LPSCl), and Li 10 GeP 2 S 12 (LGPS). Our results indicate that LPSCl provides optimal capacity retention when stored at high state-of-charge (SOC) at room temperature, but the LIC–LPSCl cathode shows significant capacity degradation and chemical incompatibility. We also established an effective electrochemical calendar aging testing protocol to simulate daily usage, enabling quick inference of the calendar life of SSBs. In conclusion, this new testing approach accelerates materials selection strategies for high-nickel NMC composite cathodes in sulfide SSBs.

25 ENERGY STORAGE↗

Asymptotic inconsistency of the cumulative algorithm for laser-induced damage probability analysis

The “cumulative algorithm” is a data analysis method that has been proposed to provide an objective, nonparametric determination of laser-induced damage probability as a function of fluence from experimental data that contain both damaged sites and undamaged sites (i.e., 1-on-1 or S-on-1 testing protocols). In this work, the limitations of this approach are explored by considering the asymptotic limit of a large number of test sites. It is shown that the cumulative algorithm does not converge to the true probability distribution and significantly underestimates the damage probability near the damage onset. Here, based on the results of this work, the cumulative algorithm is not recommended for accurate estimation of damage probability.

Computational methods↗

Evaluation of short-term initial performance of a “Molekule Air” portable air cleaner

The aim of this project was to evaluate and characterize the performance of a MOLEKULE AIR air cleaner unit. The testing protocol comprised the evaluation of an unused Molekule Air unit operating at maximum (“boost” setting) fan speed setting. The device was tested over initial short-term periods of 70-80 h of continuous operation. The tested air cleaner was challenged in separate experiments with a well-characterized mixture of volatile organic compounds (VOCs), and with ozone. All tests were performed at realistic pollutant levels in a 20-m 3 environmental stainless-steel chamber. Variables controlled and measured in this study included the chamber temperature, relative humidity, the composition and concentration of the challenge VOCs, and the concentrations of ozone. Potential formation of byproducts was also investigated to assess the overall performance.

47 OTHER INSTRUMENTATION↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

PACT Module Design Acceptance Criteria (Industry)

For the PACT center to both develop testing protocols and provide service to the metal halide perovskite (MHP) PV community, PACT will seek modules (mini and full-sized) for testing purposes. To ensure both safety and high-quality samples PACT publishes acceptance criteria to define the minimum characteristics of modules the center will accept for testing. These criteria help to ensure we are accepting technologies that are compatible with our technical facilities and testing equipment and can transition to large scale commercial manufacturing. This module design acceptance criteria document is for industry partners and is different from the acceptance criteria for research partners (academia, national laboratories) partners.

14 SOLAR ENERGY↗

PACT Module Design Acceptance Criteria (Research)

For the PACT center to both develop testing protocols and provide service to the metal halide perovskite (MHP) PV community, PACT will seek modules (mini and full-sized) for testing purposes. To ensure both safety and high-quality samples PACT publishes acceptance criteria to define the minimum characteristics of modules the center will accept for testing. These criteria help to ensure we are accepting technologies that are compatible with our technical facilities and testing equipment and can transition to large scale commercial manufacturing. This module design acceptance criteria document is for research partners (academia, national laboratories) and is different from the acceptance criteria for industry partners.

36 MATERIALS SCIENCE↗

PV Module BOM and Test Data

This dataset contains compiled results from annual PV Module Reliability Scorecards published by PV Evolution Labs – also known as PVEL. These scorecards show summary results of PV module testing performed by PVEL and name specific models of PV modules as "Top Performers" in various tests. Full details on testing, Top Performer status and other criteria for inclusion in Scorecards are documented in reports and online documentation available from https://www.modulescorecard.pvel.com. This dataset is not affiliated with PVEL and is intended only to simplify sorting and filtering Scorecard data and finding specific PV module models and Top Performer results. Note that data included in Scorecards has evolved over time, so not all data is available for all years, and testing protocols and Scorecard criteria have been changed over time.

14 SOLAR ENERGY↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗

Enterprise: a reduced-scale, flexible fuel, single-cylinder crosshead marine diesel research engine

A custom-built 1/10 scale, flexible-fuel, single-cylinder crosshead marine diesel research engine, dubbed the Enterprise, was designed and built as a platform for conducting marine lubricant research. The engine design was focused on maintaining lubricant boundary conditions similar those of full-scale engines. The Enterprise has a rated speed of 625 rpm to match the linear mean piston speed of full-scale marine engines with the reduced stroke and is capable of 18 bar brake mean effective pressure (BMEP). A high-swirl, uniflow-scavenged, two-stroke combustion system was designed to operate on either distillate diesel or heavy fuel oil (HFO). A hydraulic electronic unit injector (HEUI) fuel injection system with two injectors having customized three-hole nozzles provides fueling and is driven by the MAHLE Flexible ECU (MFE). Intake air boost is provided using a variable speed industrial air compressor along with closed-loop electronically controlled pressure regulation. Exhaust backpressure is also controlled electronically using an electro-pneumatic butterfly valve. A customized, miniaturized Hans Jensen Lubetronic cylinder lubrication system, which is capable of delivering 0.88 mg of cylinder oil per lubricator per injection to the ring pack at up to the maximum engine overspeed rating of 656 rpm, was commissioned for the Enterprise. Four independently temperature-controlled cooling zones are used to provide control of the liner temperature profile. The four coolant zones as well as the system oil and cylinder oil supplies are all controlled within 1°C for consistent thermal boundary conditions. The engine is instrumented with an in-cylinder pressure transducer as well as an inline torque transducer and numerous process temperature and pressure measurements to allow for detailed thermodynamic efficiency analysis, and experimental facilities allow for precise measurement of liner wear and characterization of deposits on the piston and rings. A radio telemetry system from IR Telemetrics is used to measure piston crown temperatures during engine operation. Engine design considerations and experimental facilities are described in detail, along with the results of a study investigating the impact of both system oil and cylinder oil viscosity on friction and efficiency. A test matrix was designed to compare base stock chemistries and viscosities for both system and cylinder oils. Experiments were completed using a fuel economy test protocol that was defined, consisting of repeating six speed/load operating conditions. An automated dynamometer control system was implemented to ensure repeatability of the test procedure. Preliminary testing indicated that the coolant, oil, and exhaust temperatures reach a steady state within 5 minutes of changing operating conditions. The system oil viscosity was found to have a significant impact on friction, with a reduction in viscosity from SAE 30 to SAE 20 resulting in over 6% reduction in friction mean effective pressure (FMEP) and over a 2% reduction in brake-specific fuel consumption (BSFC). Chemistry effects were also evident in the system and cylinder oils. Repeatability comparisons between the individual repetitions of each operating condition were used to ensure that results are statistically valid. For the initial cylinder oil viscosity experiments, observed changes were within the established/normal repeatability; ongoing experiments will determine whether improvements in boundary condition control will enable cylinder friction changes of this magnitude to be measured on this engine platform.

Kaul, Brian↗