Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility bills”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

DSO+T: Expanded Study Results DSO+T Study: Volume 5

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. This report volume provides a detailed set of results for the DSO+T study extending results presented in Volumes 1, 2, and 4. The engineering and economic performance of the transactive energy scheme is presented for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

Study of extraterrestrial disposal of radioactive wastes. Part 3: Preliminary feasibility screening study of space disposal of the actinide radioactive wastes with 1 percent and 0.1 percent fission product contamination

A preliminary study was conducted of the feasibility of space disposal of the actinide class of radioactive waste material. This waste was assumed to contain 1 and 0.1 percent residual fission products, since it may not be feasible to completely separate the actinides. The actinides are a small fraction of the total waste but they remain radioactive much longer than the other wastes and must be isolated from human encounter for tens of thousands of years. Results indicate that space disposal is promising but more study is required, particularly in the area of safety. The minimum cost of space transportation would increase the consumer electric utility bill by the order of 1 percent for earth escape and 3 percent for solar escape. The waste package in this phase of the study was designed for normal operating conditions only; the design of next phase of the study will include provisions for accident safety. The number of shuttle launches per year required to dispose of all U.S. generated actinide waste with 0.1 percent residual fission products varies between 3 and 15 in 1985 and between 25 and 110 by 2000. The lower values assume earth escape (solar orbit) and the higher values are for escape from the solar system.

Hyland, R. E.↗

Energy conservation and the residential and commercial sector

A detailed analysis of energy conservation actions relevant to the residential and commercial sector has led to the conclusion that the potential for savings is great. The task will not be easy, however, since many of the actions require significant life style changes that are difficult to accomplish. Furthermore, many of the conservation actions cited as instant solutions to the energy crisis are those with only mid to long term potential, such as solar energy or heat pumps. Three significant conservation approaches are viable: adjusting price structure, mandating actions, and educating consumers. The first two appear to be the most feasible. But they are not without a price. Higher utility bills adversely affect the poor and the elderly on fixed incomes. Likewise, strict mandatory measures can be quite distasteful. But the effect of alternatives, such as voluntary savings accomplished through education processes, is minimal in a nation without a true conservation ethic.

Source record↗

Radiation Insulation

An aluminized polymer film is a highly effective radiation barrier for both manned and unmanned spacecraft. Variations of this space-devised material are also used as an energy conservation technique for homes and offices. One commercial company, Tech 2000 (formerly Buckeye Radiant Barrier), markets 'Super R' Radiant Barrier, which finds its origins in the Apollo Mission programs. The material is placed between wall studs and exterior facing before siding or in new roof installation, between roof support and roof sheathing. Successful retrofit installations have included schools and shrink wrap ovens. The radiant barrier blocks 95 percent of radiant energy, thus retaining summer heat and blocking winter cold. Suppliers claim utility bill reductions of 20 percent or more.

Source record↗

ePROJECT BUILDER: PROMOTING WIDER ADOPTION OF ENERGY SAVINGS PERFORMANCE CONTRACTS THROUGH STANDARDIZATION AND TRANSPARENCY

The United States Federal Government has been conducting guaranteed savings energy savings performance contracts for over 20 years and now relies on ESPC for the majority of its energy efficiency work. Along with a related financed project type, these deals resulted in $4.2 billion of project investment in the five years ending in 2016, a pace that has even accelerated since. Measurement and verification (M&V) on the projects is the key to assuring savings realization and persistence. Perceived as a weakness or burdensome added cost in the early years of the program, M&V has become a strength. All energy conservation measures (ECMs) have some form of measurement – defined as a measured baseline establishment followed by at least one measurement of the main energy-saving parameter taken in the performance period for each ECM. The government’s in-house energy consulting office, the Federal Energy Management Program (FEMP), now recommends measurement of these “Option A” M&V ECMs throughout the contract term, usually annually. Moreover, a significantly higher percentage of projects are now characterized by more ambitious M&V, including Option B (all parameter measurement) for most generation (including renewable) and some efficiency measures, and more frequent Option C (whole facility utility bill analysis) for “deep retrofit” projects with multiple, interactive ECMs. Coincident with this progress in M&V has been a much greater embracing of ESPC by the federal agencies, resulting in the enormous rate of projects now executed. This paper traces the evolution of M&V in federal ESPC and argues that the heightened credibility of the savings has contributed significantly to the procurement vehicle’s long-term viability. This focus on savings integrity via M&V has been learned over two decades for U.S. federal ESPC, but countries with developing ESPC markets would be wise to emphasize it as their markets emerge, allowing them to avoid some of the “growing pains” experienced in the U.S.

Earni, Shankar↗

M&V in ESPC: The U.S. Federal Experience and Implications for Developing ESPC Markets

The United States Federal Government has been conducting guaranteed savings energy savings performance contracts for over 20 years and now relies on ESPC for the majority of its energy efficiency work. Along with a related financed project type, these deals resulted in $4.2 billion of project investment in the five years ending in 2016, a pace that has even accelerated since. Measurement and verification (M&V) on the projects is the key to assuring savings realization and persistence. Perceived as a weakness or burdensome added cost in the early years of the program, M&V has become a strength. All energy conservation measures (ECMs) have some form of measurement – defined as a measured baseline establishment followed by at least one measurement of the main energy-saving parameter taken in the performance period for each ECM. The government’s in-house energy consulting office, the Federal Energy Management Program (FEMP), now recommends measurement of these “Option A” M&V ECMs throughout the contract term, usually annually. Moreover, a significantly higher percentage of projects are now characterized by more ambitious M&V, including Option B (all parameter measurement) for most generation (including renewable) and some efficiency measures, and more frequent Option C (whole facility utility bill analysis) for “deep retrofit” projects with multiple, interactive ECMs. Coincident with this progress in M&V has been a much greater embracing of ESPC by the federal agencies, resulting in the enormous rate of projects now executed. This paper traces the evolution of M&V in federal ESPC and argues that the heightened credibility of the savings has contributed significantly to the procurement vehicle’s long-term viability. This focus on savings integrity via M&V has been learned over two decades for U.S. federal ESPC, but countries with developing ESPC markets would be wise to emphasize it as their markets emerge, allowing them to avoid some of the “growing pains” experienced in the U.S.

Coleman, Philip↗

M&V in ESPC: The U.S. Federal Experience and Implications for Developing ESPC Markets

The United States Federal Government has been conducting guaranteed savings energy savings performance contracts for over 20 years and now relies on ESPC for the majority of its energy efficiency work. Along with a related financed project type, these deals resulted in $4.2 billion of project investment in the five years ending in 2016, a pace that has even accelerated since.Measurement and verification (M&V) on the projects is the key to assuring savings realization and persistence. Perceived as a weakness or burdensome added cost in the early years of the program, M&V has become a strength. All energy conservation measures (ECMs) have some form of measurement – defined as a measured baseline establishment followed by at least one measurement of the main energy-saving parameter for a given ECM taken in the performance period. The government’s in-house energy consulting office, the Federal Energy Management Program (FEMP), now recommends measurement of these “Option A” M&V ECMs throughout the contract term, usually annually. Moreover, a significantly higher percentage of projects are now characterized by more ambitious M&V, including Option B (all parameter measurement) for most generation (including renewable) and some efficiency measures, and more frequent Option C (whole facility utility bill analysis) for “deep retrofit” projects with multiple, interactive ECMs. Coincident with this progress in M&V has been a much greater embracing of ESPC by the federal agencies, resulting in the enormous rate of projects now executed. This paper traces the evolution of M&V in federal ESPC and argues that the heightened credibility of the estimated (and guaranteed) savings has contributed significantly to the procurement vehicle’s long-term viability. This focus on savings integrity via M&V has been learned over two decades for U.S. federal ESPC, but countries with developing ESPC markets would be wise to emphasize it as their markets emerge, allowing them to avoid some of the “growing pains” experienced in the U.S.

Coleman, Philip↗

Monitoring Based Commissioning: Step-by-Step Approach to Implementation in Chiller Plants

Chilled water systems consume a significant portion of the energy in manufacturing, and inefficient operation could significantly influence utility bills and the environmental footprint of a facility. One way to ensure long-term energy-efficient plant operation is to ensure that chilled water system equipment, such as chillers, cooling towers, and pumps, are running at their best. Periodic operational assessments help to meet efficiency objectives for cooling plants. However, occasional set point and operational changes resulting from short-term fluctuations cause the plant operation to deviate from optimal. These changes accumulate over time, and operational efficiency deteriorates. Significant energy efficiency improvement potential in chilled water systems can be achieved by operational changes alone. Recent developments in information technology and the industrial internet of things data processing ability have overcome traditional problems and given rise to a new paradigm: monitoring-based commissioning (MBCx). Commissioning platforms and fault detection and diagnostics capabilities have evolved over time and presented more sophisticated abilities to efficiently control process cooling plants. The typical architectures of the MBCx process and a detailed approach to implement the process for chilled water systems are presented. A case study highlighting the energy-and cost-savings potential of MBCx systems is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Consumer Guide to Residential Renewable Energy

Learn how installing residential renewable energy systems, such as geothermal heat pumps and wind or solar energy systems, can save energy, lower utility bills, and earn homeowners money. This fact sheet from Energy Saver includes information on how to start planning to install renewable energy systems at home.

residential renewable energy, geothermal heat pump↗

Onsite Energy Techno-Economic Analysis Using REopt

Since 2019, the National Renewable Energy Laboratory (NREL) has collaborated with IEDO's Combined Heat and Power (CHP) Deployment Program and the CHP Technical Assistance Partnerships (TAPs) to expand the capabilities of NREL's publicly available REopt® tool for techno-economic analysis of on-site energy. As a result, capabilities to analyze heating and cooling loads and serve those loads with CHP were added to the REopt tool in 2021. Currently, NREL is using REopt to evaluate the economics and feasibility of deploying distributed energy resources at sites of 3-5 manufacturers. The analysis is based on location, site-specific load data, customized utility bill analysis, and other criteria such as resilience needs and decarbonization targets. The objectives of the current effort are to (1) assist manufacturers with analyzing on-site energy options, including CHP, solar photovoltaics (PV), wind, and battery storage, (2) validate the capabilities and use of REopt to provide technical assistance to manufacturers, and (3) publish case studies showcasing the engagement, key takeaways, and lessons learned. Future work is expected to include additional REopt capabilities for evaluating other technologies to reduce scope 1 emissions, such as electrifying process heating loads, using carbon-free fuels, and other clean heat strategies.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Solar Consolidated Billing: An Exploration of Implementation and Alternatives

The report presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.

14 SOLAR ENERGY↗

Community Solar Consolidated Billing: An Exploration of Implementation and Alternatives [Slides]

This presentation is an abridged version of the report it is based on that presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.

14 SOLAR ENERGY↗

Alternative Approaches to Traditional Net Energy Metering

Most jurisdictions in the United States originally implemented net energy metering (NEM) tariffs to support the deployment and interconnection of distributed generation (DG) resources (e.g., rooftop solar photovoltaic systems). Since then, NEM has proven effective in promoting adoption of DG resources. Recently, due to concerns about sufficient recovery of utilities’ revenue requirements and cost-shifting, there is increasing interest in—or statutory requirements to pursue—alternative compensation approaches, especially in U.S. states and territories with robust growth in distributed solar. Recent increases in other forms of distributed energy resources (DERs) that can potentially send power to the distribution grid (e.g., distributed battery energy storage system (BESS)) are further driving compensation reforms. This brief provides an overview of design elements associated with alternative approaches to traditional NEM, summarizes common arguments for and against them, and identifies implementation issues that utilities may need to address. Although this brief may be most useful in jurisdictions that are interested in or required to move beyond NEM, it is also applicable to those jurisdictions that have already done so—and are looking to further implement reforms to their existing compensation mechanisms. In the broadest sense, there are three primary tariff-related components when interconnecting a DER onto the local utility’s distribution system (adapted from Zinaman et al., 2017): 1. Metering and Billing Arrangements: How utilities measure and bill electricity consumption and production. 2. DER Export Tariff Design: The structure under which utilities compensate customers for electricity they export to the grid. 3. Consumption Tariff Design: The structure under which customers pay for electricity they consume from the grid. When implementing changes to any of these primary tariff-related components, there are likely implications for a utility’s metering system, billing system, and other technology systems. Where applicable, this brief explicitly identifies such implementation challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗