Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Designing Advanced Electrolytes for High-Voltage High-Capacity Disordered Rocksalt Cathodes

Lithium (Li)-excess transition metal oxide materials which crystallize in the cation-disordered rock salt (DRX) structure are promising cathodes for realizing low-cost, high-energy-density Li batteries. However, the state-of-the-art electrolytes for Li-ion batteries cannot meet the high-voltage stability requirement for high-voltage DRX cathodes, thus new electrolytes are urgently demanded. It has been reported that the solvation structures and properties of the electrolytes critically influence the performance and stability of the batteries. In this study, the structure–property relationships of various electrolytes with different solvent-to-diluent ratios are systematically investigated through a combination of theoretical calculations and experimental tests and analyses. This approach guides the development of electrolytes with unique solvation structures and characteristics, exhibiting high voltage stability, and enhancing the formation of stable electrode/electrolyte interphases. These electrolytes enable the realization of Li||Li 1.094 Mn 0.676 Ti 0.228 O 2 (LMTO) DRX cells with improved performance compared to the conventional electrolyte. Specifically, Li||LMTO cells with the optimized advanced controlled-solvation electrolyte deliver higher specific capacity and longer cycle life compared to cells with the conventional electrolyte. Additionally, the investigation into the structure–property relationship provides a foundational basis for designing advanced electrolytes, which are crucial for the stable cycling of emerging high-voltage cathodes.

25 ENERGY STORAGE↗

A Three-Stage Enhanced Reactive Power and Voltage Optimization Method for High Penetration of Solar

This paper presents a three-stage enhanced volt/var optimization method to stabilize voltage fluctuations in transmission networks by optimizing the usage of reactive power control devices. In contrast with existing volt/var optimization algorithms, the proposed method optimizes the voltage profiles of the system, while keeping the voltage and real power output of the generators as close to the original scheduling values as possible. This allows the method to accommodate realistic power system operation and market scenarios, in which the original generation dispatch schedule will not be affected. The proposed method was tested and validated on a modified IEEE 118-bus system with photovoltaic data.

photovoltaic, Volt/Var Control, indexes, simulatio↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Single-crystal NMC622 from combustion-assisted solid-state synthesis: Tunable particle size, voltage-dependent stability, and Li-ion diffusion

Cost-effective and scalable synthesis of single-crystal lithium–metal-oxide cathodes with controlled size and morphology remains challenging for advancing high-performance lithium-ion batteries. Here, we demonstrate a solution combustion–assisted solid-state method for producing single-crystal NMC622 with tunable particle size at various lithium stoichiometries. Structural and electronic characteristics were probed using synchrotron-XANES, EXAFS, XRD and XPS, confirming well-defined coordination environments and phase purity up to Li ≈ 1.3. The electrochemical behavior of LixNMC (x = 1.0 and 1.3) single crystals was evaluated across 2.8–4.3 V and 2.8–4.7 V windows to elucidate the effects of lithium content and operating voltage. At 2.8–4.3V, Li1.3NMC exhibits higher initial capacity due to its larger lithium inventory, while Li1.0NMC shows superior long-term retention driven by its larger crystal size and reduced structural distortion. Increasing the cutoff voltage to 4.7 V enhances the initial capacity of both compositions by 17–25%, but long-term capacity retention ultimately converges to values comparable to those at 4.3 V due to voltage-induced degradation, where Li+ diffusion constant remains lying ranging from 10−12 –10−11 cm2s−1. Overall, this study establishes a scalable combustion-assisted route for synthesizing tunable single-crystal NMC622 and highlights the interplay between lithium stoichiometry, particle size, and voltage window in governing cathode stability.

Roy, Subrata C [Jackson State University]↗

Simultaneous Stabilization of LiNi 0.76 Mn 0.14 Co 0.10 O 2 Cathode and Lithium Metal Anode by Lithium Bis(oxalato)borate as Additive

Abstract The long‐term cycling performance, rate capability, and voltage stability of lithium (Li) metal batteries with LiNi 0.76 Mn 0.14 Co 0.10 O 2 (NMC76) cathodes is greatly enhanced by lithium bis(oxalato)borate (LiBOB) additive in the LiPF 6 ‐based electrolyte. With 2 % LiBOB in the electrolyte, a Li∥NMC76 cell is able to achieve a high capacity retention of 96.8 % after 200 cycles at C/3 rate (1 C=200 mA g −1 ), which is the best result reported for a Ni‐rich NMC cathode coupled with Li metal anode. The significantly enhanced electrochemical performance can be ascribed to the stabilization of both the NMC76 cathode/electrolyte and Li‐metal‐anode/electrolyte interfaces. The LiBOB‐containing electrolyte not only facilitates the formation of a more compact solid–electrolyte interphase on the Li metal surface, it also forms a enhanced cathode electrolyte interface layer, which efficiently prevents the corrosion of the cathode interface and mitigates the formation of the disordered rock‐salt phase after cycling. The fundamental findings of this work highlight the importance of recognizing the dual effects of electrolyte additives in simultaneously stabilizing both cathode and anode interfaces, so as to enhance the long‐term cycle life of high‐energy‐density battery systems.

Zhao, Wengao↗

Deciphering Chemical/Electrochemical Compatibility of Li 3 InCl 6 in 5.2 V High-Voltage LiCoO 2 All-Solid-State Batteries

Large interfacial resistance is a widely recognized impediment to the advancement of high-voltage, all-solid-state batteries. However, a comprehensive understanding of the fundamental cause behind the interfacial resistance between solid electrolytes and typical layered oxide cathodes has not yet been achieved. Here, we investigated the high-voltage stability of Li 3 InCl 6 and elucidated the underlying interfacial electrochemical reactions between LiCoO 2 and Li 3 InCl 6 . Further, the pairing of Li 3 InCl 6 with LiCoO 2 exhibited a superior capacity retention of 73.6% even at 5.2 V, much higher than 28.2% charged at 4.6 V in lithium-ion batteries after 70 cycles. The enhanced high-voltage stability of ASSBs is attributed to the stable interface formed between LiCoO 2 and Li 3 InCl 6 and the reinforced surface and bulk structure stability. On the other hand, the ultrahigh voltage still causes the partial decomposition of Li 3 InCl 6 and generates interfacial compounds such as InClO and cobalt and indium chlorides/oxides.

25 ENERGY STORAGE↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

LiF dissolution by anion-binding-agent in LiCF x battery systems: Lower ohmic and interfacial resistance.

In this paper we will discuss our preliminary thermal and electrochemical data aimed at developing a robust nonflammable Li-CFx cell capable of wide temperature operation. To accomplish this goal, we are evaluating a thermally stable solvent comprised of an anion binding agent (ABA) and lithium fluoride (LiF), typically at a 1:1 molar ratio. In conventional carbonate based electrolytes, ABA is soluble while LiF remains insoluble. However, the neutral ABA solubilizes LiF and forms a salt complex represented as Li+(ABAF-). We are exploiting this unique feature and apply this strategy to CFx chemistry to improve cell performance, due to the CFx cell chemistry generating LiF as discharge product. Continuous solvation of the salt mixture during discharge allows for utilization of electrolytes initially containing sub stoichiometric amount of LiF. The practical benefits are reduced cell weight, mitigation of electrode fouling, and consequently better low temperature performance. Electrolytes containing dimethyl methyl phosphonate (DMMP), 1M tris(pentafluorophenyl) borane (TPFB) and varying concentrations of LiF (1M; 0.5M and 0.1M) were prepared and characterized for ionic conductivity and voltage stability. In general, ionic conductivity decreases with decreasing LiF concentration. The room temperature conductivity for the DMMP 1M TPFB:1M LiF is ~ 9mS/cm and ~3mS/cm for the 1M TPFB:0.1M LiF. Unlike the conductivity, the electrochemical voltage stability did not vary substantially with LiF concentration and the electrolytes showed a stable voltage window in the range 0-3.5V vs. Li + /Li, which is substantially wider than the Li-CFx cell voltage. Flammability measurement performed at our thermal abuse facility demonstrated that the electrolyte was nonflammable. Discharge performance of CFx materials obtained from several vendors was evaluated in 2032 coin cells at room temperature. Experimental results demonstrate a reduction in ohmic resistance and interfacial resistance during discharge for a cell containing lower concentrations of added LiF compared to ABA. These observations are a direct demonstration that the unbound ABA in the electrolyte dissolves the LiF generated in the discharge reaction.

25 ENERGY STORAGE↗

Artificial cathode electrolyte interphase for improving high voltage cycling stability of thick electrode with Co-free 5 V spinel oxides

Spinel-type cathode LiNi 0.5 Mn 1.5 O 4 (LNMO) has intrigued the transportation industry due to its high operating voltage and total elimination of the expensive cobalt element. However, LNMO cathode with high mass loading (> 3 mAh/cm 2 in areal capacity) has suffered from excessive capacity degradation upon long cycling. Here, a robust Al 2 O 3 surface layer is introduced to the thick LNMO electrode via atomic layer deposition (ALD). The capacity retention in full cells with the graphite anode is improved from 46.3% to 75.3% after 300 cycles with cutoff voltage up to 4.85 V, while enabling average Coulombic efficiency of 99.9% during the cycling. The post-mortem analyses reveal that the Al 2 O 3 surface layer would convert to Al-O-F /Al-F species upon cycling, offering stable interphase to protect the cathode material. Furthermore, these results demonstrate the significance of surface modification enabling high voltage cathode for next-generation LIBs.

25 ENERGY STORAGE↗

A Solar-assisted Voltage Optimization Method for Transmission Solar Network Power System

This paper proposes a new formulation and solution algorithm that uses transmission level solar inverters to address the security-constrained optimal power flow (SCOPF) problem. The goal is to stabilize voltage fluctuations in transmission networks in base case and contingency scenarios, by using bulk solar power plant with a minimal number of post-contingency corrections. To achieve this goal, a two-stage volt/var optimization method is proposed to first correct all voltage violations with the volt-var alternating current optimal power flow (ACOPF) algorithm for a base case. Then a linearized SCOPF volt-var control algorithm is proposed to identify the corrective actions for all potential voltage violations in all contingency scenarios. The proposed method was tested and validated on a modified IEEE 118-bus system with solar photovoltaic (PV) data.

Photovoltaic, Volt/Var Control↗

Machine Learning-based Cyber-Physical Anomaly Detection in Wide Area Voltage Control Systems

Wide-area voltage control systems (WAVCS) are widely deployed in power grid to improve the voltage stability in transmission system using Flexible AC Transmission System (FACTS) devices. The WAVCS relies on wide-area measurement and control signals for closed-loop control of FACTS devices to improve the transient voltage stability in power grid in real-time. Since the WAVCS utilizes a cyber-layer communication during its normal operation, they are susceptible to cyber attacks from adversaries which can lead to a voltage collapse if the attacks go undetected and unmitigated. This paper proposes a supervised machine learning (ML)-based anomaly detection algorithm for detecting various stealthy cyber attacks in the context of WAVCS cybersecurity. In particular, a fuzzy logic-based wide-area controller, as proposed by the Bonneville Power Administration (BPA), is implemented on the Kundur’s four machine two-area system that is integrated with a static var compensator (SVC) to improve voltage profile on sensitive buses. Later, different types of data integrity attacks, including pulse and ramp attacks, are considered on the wide-area measurement and control signals to analyze the performance of the proposed anomaly detector. Our experimental evaluation shows a promising performance with a high true-positive rate (more than 99%) and low false-negative rate (less than 1%) while exhibiting a small prediction time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigations on the low voltage cathodoluminescence stability and surface chemical behaviour using Auger and X-ray photoelectron spectroscopy on LiSrBO{sub 3}:Sm{sup 3+} phosphor

Highlights: {yields} Stable orange-red cathodoluminescence observed from LiSrBO{sub 3}:Sm{sup 3+} phosphor. {yields} In situ Auger electron spectroscopy, while monitoring the CL output reduction, reveals surface concentration modification of Li, Sr, B and O atoms. {yields} X-ray photoelectron spectroscopy confirms the formation of SrO{sub 2} layer due to the electron stimulated surface chemical reactions (ESSCRs). This layer is possibly contributing to the surface chemical stability and prevents further degradation. -- Abstract: Orange-red emissive LiSrBO{sub 3}:Sm{sup 3+} phosphors were synthesized through the solid-state reaction method. Under UV radiation (221 nm) and low-voltage electron beam (2 keV, 12 mA/cm{sup 2}) excitation, the Sm{sup 3+} doped LiSrBO{sub 3} phosphor shows emission corresponding to the characteristic {sup 4}G{sub 5/2}-{sup 6}H{sub 7/2} transitions of Sm{sup 3+} with the strongest emission at 601 nm. A high stability of cathodoluminescence (CL) emission during prolong electron bombardment with low-energy electrons was observed. Surface sensitive diagnostic tools such as Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) were used to study the surface chemistry. AES results revealed modifications in the surface concentrations of Li, Sr, B, O and C on the surface of the LiSrBO{sub 3}:Sm{sup 3+} phosphor as indicated by the changes in their Auger peak to peak heights (APPH) as a function of electron dose. Observed changes in the high resolution XPS spectra of the LiSrBO{sub 3}:Sm{sup 3+} surface irradiated with the low energy electron beam provide evidence of compositional and structural changes as a result of the electron beam stimulated surface chemical reactions (ESSCRs). Additional SrO{sub 2} was identified by XPS on the phosphor surface after it received an electron dose of 300 C/cm{sup 2} together with the increase in the concentrations of chemical species containing the B-C-O bonding. The new surface chemical species formed during electron beam bombardment are possibly responsible for the stability of the CL in the LiSrBO{sub 3}:Sm{sup 3+} phosphor.

36 MATERIALS SCIENCE↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing Gaussian Assumption of PMU Measurement Error Using Field Data

Gaussian PMU measurement noise has been assumed for many power system applications, such as state estimation, oscillatory modes monitoring, voltage stability analysis, to cite a few. This letter proposes a simple yet effective approach to validate this assumption by using the stability property of a probability distribution and the concept of redundant measurement. Extensive results using field PMU data from WECC system reveal that the Gaussian assumption is questionable.

Wang, Shaobu (ORCID:0000000236073573)↗