Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray diffraction grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Highly efficient ultra-low blaze angle multilayer grating

We have developed an advanced process for blaze angle reduction of x-ray gratings for the soft, tender, and EUV spectral ranges. The process is based on planarization of an anisotropically etched Si blazed grating followed by a chemically selective plasma etch. This provides a way to adjust the blaze angle to any lower value with high accuracy. Here we demonstrate the reduction of the blaze angle to an extremely low value of 0.04°±0.004°. For a 100 lines/mm grating with a Mo/Si multilayer coating, the grating exhibits diffraction efficiency of 58% in the 1 st diffraction order at a wavelength of 13.3 nm. This technique will be applicable to a wide range of uses of high efficiency gratings for synchrotron sources, as well as for Free Electron Lasers (FEL).

42 ENGINEERING↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Study of SXR/EUV radiation of exploded foils and wires with spectral, spatial and temporal resolution simultaneously on KING electric discharge facility.

The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Encoding the complete electric field of an ultraviolet ultrashort laser pulse in a near-infrared nonlinear-optical signal

We introduce a variation on the cross-correlation frequency-resolved optical gating (XFROG) technique that uses a near-infrared (NIR) nonlinear-optical signal to characterize pulses in the ultraviolet (UV). Using a transient-grating XFROG beam geometry, we create a grating using two copies of the unknown UV pulse and diffract a NIR reference pulse from it. We show that, by varying the delay between the UV pulses creating the grating, the UV pulse intensity-and-phase information can be encoded into a NIR signal. We also implemented a modified generalized-projections phase-retrieval algorithm for retrieving the UV pulses from these spectrograms. We performed proof-of-principle measurements of chirped pulses and double pulses, all at 400 nm. This approach should be extendable deeper into the UV and potentially even into the extreme UV or x-ray range.

47 OTHER INSTRUMENTATION↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Revealing Nanoscale Energy Flow Using Ultrafast THz to X-ray Beams (Final Technical Report)

We developed novel spectroscopic methods and made use of them to study energy flow and material properties on nanometer length scales and ultrafast time scales. Access to short length scales was provided through the use of light beams with short wavelengths (EUV through hard x-ray spectral ranges) and/or fabricated structural elements with nanometer dimensions. Recent advances in tabletop high harmonic generation of extreme ultraviolet (EUV) pulses were exploited to measure thermal transport and acoustic vibrations using time-resolved diffraction from photoexcited periodic nanostructures, revealing new physics that arises at length scales of tens to hundreds of nm. The tabletop EUV sources as well as the FERMI free electron laser at FERMI-Elettra in Trieste were used to generate as well as measure nanoscale thermoelastic responses without the need for patterned nanostructures, with the short length scale coming from optical interference patterns formed by crossing pairs of beams in transient grating experiments. We also used EUV and optical sources to excite and monitor ultrahigh-frequency acoustic waves (coherent phonons) at ultraflat interfaces and multilayer structures, extending our measurements of the highest-frequency coherent acoustic waves observed to date. Our measurements of acoustic properties allowed direct calculation of thermal conductivities which can be compared with our measurements of thermal transport and with first-principles calculations. Terahertz-frequency acoustic measurements can also be used to reveal complex relaxation dynamics in glass-forming liquids and partially disordered solids. Acoustic measurements were used to investigate the confinement effect in ultrathin liquid layers and to characterize mechanical properties of ultrathin solid layers. The methods we developed have broad fundamental applications and may also enable new practical metrology for use in nanoelectronics, just as earlier methods we developed have found commercial applications in microelectronics metrology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Review of rigorous coupled-wave analysis and of homogeneous effective medium approximations for high spatial-frequency surface-relief gratings

A review of the rigorous coupled-wave analysis as applied to the diffraction of electro-magnetic waves by gratings is presented. The analysis is valid for any polarization, angle of incidence, and conical diffraction. Cascaded and/or multiplexed gratings as well as material anisotropy can be incorporated under the same formalism. Small period rectangular groove gratings can also be modeled using approximately equivalent uniaxial homogeneous layers (effective media). The ordinary and extraordinary refractive indices of these layers depend on the gratings filling factor, the refractive indices of the substrate and superstrate, and the ratio of the freespace wavelength to grating period. Comparisons of the homogeneous effective medium approximations with the rigorous coupled-wave analysis are presented. Antireflection designs (single-layer or multilayer) using the effective medium models are presented and compared. These ultra-short period antireflection gratings can also be used to produce soft x-rays. Comparisons of the rigorous coupled-wave analysis with experimental results on soft x-ray generation by gratings are also included.

Glytsis, Elias N.↗

One-dimensional neutron diffraction from layered graphite: Reciprocal space structure and grating behavior

In this work we report observations of one-dimensional neutron diffraction from highly oriented pyrolytic graphite (HOPG), where the scattering angle varies continuously with incident angle following classical grating-like behavior. The 2D polycrystalline structure of HOPG—with highly aligned layers along the 𝑐 axis but random in-plane rotations—creates planes of scattering intensity in reciprocal space at 𝑄 𝑐 =𝑛⁢(2⁢𝜋/𝑑) where 𝑑=3.35Å is the interlayer spacing. As the Ewald sphere sweeps through reciprocal space during sample rotation, it continuously intersects these planes, producing the observed angular dispersion. We observe both first-order (𝑛=1) and second-order (𝑛=2) diffraction at conventional scattering angles (25°–70°), with peak positions that remain temperature-independent between 10 K and 294 K and follow quantitative agreement with momentum conservation 𝑄 𝑐 =𝑘⁢[sin⁡𝜓−sin⁡𝜓 𝑓 ]=𝑛⁢(2⁢𝜋/𝑑). X-ray diffraction under similar conditions shows no comparable behavior, confirming that sharp nuclear-vacuum contrast is essential. While diffraction intensities are weak (∼10 −6 of Bragg peaks), the observations demonstrate how the interplay of atomic-scale periodicity, nuclear contrast, and structural disorder enables observation of continuous diffraction curves at thermal neutron wavelengths, illustrating how HOPG's unique microstructure determines its scattering properties beyond conventional Bragg diffraction.

2-dimensional systems↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

NH3-SCR on Cu, Fe and Cu+Fe exchanged Beta and SSZ-13 catalysts: hydrothermal aging and propylene poisoning effects

Cu, Fe and Cu+Fe ion exchanged Beta and SSZ-13 catalysts were prepared by solution ion exchange using commercial NH4/Beta, and NH4/SSZ-13 that was prepared in-house. To study hydrothermal aging effects, Beta supported catalysts were aged hydrothermally at 700 C and SSZ-13 supported catalysts were aged at 750 C. In order to reveal the effects of Fe addition in the co-exchanged catalysts, these catalysts were characterized by means of powder X-ray diffraction (XRD), N2 adsorption-desorption, electron paramagnetic resonance (EPR), 27Al-nuclear magnetic resonance (27Al-NMR) and propylene coking followed with temperature programmed reaction (TPR), and further tested with standard NH3-SCR with and without the presence of propylene. Collectively, the catalyst characterizations and reaction testing indicated minor beneficial effects of Fe addition in Cu,Fe/Beta, where NH3-SCR activity, N2 selectivity and hydrothermal stability were all slightly improved. In contrast, Fe addition did not show apparent beneficial effects in low-temperature SCR for the Cu,Fe/SSZ-13 case. At elevated reaction temperatures, however, the presence of Fe indeed considerably improved NO conversion and N2 selectivity for the hydrothermally aged Cu,Fe/SSZ-13 catalyst in the presence of propylene. The authors from Pacific Northwest National Laboratory (PNNL) gratefully acknowledge the US Department of Energy (DOE), Energy Efficiency and Renewable Energy, Vehicle Technologies Office for the support of this work. The research described in this paper was performed in the Environmental Molecular Sciences Laboratory (EMSL), a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at PNNL. PNNL is operated for the US DOE by Battelle. The authors from East China University of Science and Technology acknowledge support from National Basic Research Program of China (2013CB933200), National Natural Science Foundation of China (21577035, 21577034), Commission of Science and Technology of Shanghai Municipality (15DZ1205305) and 111 Project (B08021). Aiyong Wang also gratefully acknowledges the China Scholarship Council for a Joint-Training Scholarship Program with PNNL.

Wang, Aiyong↗

Hybrid method simulations of a soft x-ray beamline

A wavefront propagation analysis of a soft X-ray beamline using the HYBRID method is reported. All elements of the beamline: the energy dependence of the insertion device emission, the beamline mirrors and their measured figure errors, the variable-line-spacing grating and its measured figure error, and several exit slit settings, are included in the simulations. The analysis of the propagated undulator radiation through the beamline at two slightly different deflection parameter values demonstrates that, within the beamline angular acceptance and when the monochromator is tuned to the same energy, the flux is higher when the undulator is tuned to slightly higher energy than that of the monochromator. The energy resolution determined from the FWHM of the energy bandwidth transmitted through the exit slit is narrower when the undulator is tuned to higher energy than the monochromator. This is not the case when the resolution is based on the standard deviation of the transmitted energy band. The diffraction effects due to the exit slit size and their consequence on the spot size at the sample position are investigated for a few photon energies.

beamline↗

Advanced optical instruments technology

The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

Shao, Mike↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Fabricating Radial Groove Gratings Using Projection Photolithography

Projection photolithography has been used as a fabrication method for radial grove gratings. Use of photolithographic method for diffraction grating fabrication represents the most significant breakthrough in grating technology in the last 60 years, since the introduction of holographic written gratings. Unlike traditional methods utilized for grating fabrication, this method has the advantage of producing complex diffractive groove contours that can be designed at pixel-by-pixel level, with pixel size currently at the level of 45 45 nm. Typical placement accuracy of the grating pixels is 10 nm over 30 nm. It is far superior to holographic, mechanically ruled or direct e-beam written gratings and results in high spatial coherence and low spectral cross-talk. Due to the smooth surface produced by reactive ion etch, such gratings have a low level of randomly scattered light. Also, due to high fidelity and good surface roughness, this method is ideally suited for fabrication of radial groove gratings. The projection mask is created using a laser writer. A single crystal silicon wafer is coated with photoresist, and then the projection mask, with its layer of photoresist, is exposed for patterning in a stepper or scanner. To develop the photoresist, the fabricator either removes the exposed areas (positive resist) of the unexposed areas (negative resist). Next, the patterned and developed photoresist silicon substrate is subjected to reactive ion etching. After this step, the substrate is cleaned. The projection mask is fabricated according to electronic design files that may be generated in GDS file format using any suitable CAD (computer-aided design) or other software program. Radial groove gratings in off-axis grazing angle of incidence mount are of special interest for x-ray spectroscopy, as they allow achieving higher spectral resolution for the same grating area and have lower alignment tolerances than traditional in-plane grating scheme. This is especially critical for NASA Constellation- X project that will utilize hundreds of gratings all of which need to be precisely aligned for x-ray observation of space.

Iazikov, Dmitri↗

Study of VUV radiation of hybrid and standard X-pinches on KING electric discharge facility

The radiative characteristics of standard and hybrid X-pinches are studied in VUV range on the small-size KING electric discharge facility (200 kA, 190 ns, 45 kV) for the same initial conditions. In this work, studies were performed for different X-pinch materials. A comparative analysis of the VUV spectra was performed and the output energy of soft x-rays and VUV radiation was measured for standard and hybrid X-pinches.

bright spot↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗