Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Joule-Thomson effect and internal convection heat transfer in turbulent He II flow

The temperature rise in highly turbulent He II flowing in tubing was measured in the temperature range 1.6-2.1 K. The effect of internal convection heat transport on the predicted temperature profiles is calculated from the two-fluid model with mutual friction. The model predictions are in good agreement with the measurements, provided that the pressure gradient term is retained in the expression for internal convection heat flow.

Walstrom, P. L.↗

Grossite-Rich Refractory Inclusions in Carbonaceous Chondrites: Evidence for Early Generation of Different O-Isotope Reservoirs in the Protoplanetary Disk and O-Isotope Exchange During Fluid-Rock Interaction

The oxygen isotopic composition of the Sun inferred from the measurements of the solar wind returned by the Genesis spacecraft is O-16-enriched (△O-17 = -28.4±3.6‰) relative to the whole-rock O-isotope compositions of chondrites and achondrites, and chondrule phenocrysts, which all plot close to the terrestrial fractionation line (△O-17 ∼ ±5‰). Vast majority of refractory inclusions (CAIs and AOAs) in carbonaceous chondrites of petrologic types 2-3.0 are iso-topically uniform and have solar-like △O-17. In contrast, CAIs and AOAs in metamorphosed CV and CO chondrites are isotopically heterogeneous with melilite, anorthite, perovskite, Zr- and Sc-rich oxides and silicates, and occasionally Al, Ti-diopside being O-16-depleted relative to hibonite, spinel, Al-diopside, and forsterite. The timing of generation of different O-isotope reservoirs and the nature of O-isotope heterogeneity in refractory inclusions in CO3 and CV3 chondrites are poorly known. Grossite (CaAl4O7) is one of the first minerals predicted to condense from a gas of solar composition and therefore it could have recorded isotopic compositions of reservoirs during the earliest stages of the Solar System evolution. Here we report on O-isotope compositions of grossite-rich CAIs in CH3 and CO3 chondrites measured in situ with the UH Cameca ims-1280. For analytical procedures see [9].

A N Krot↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 150,000 psi) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Elastohydrodynamic film thickness model for heavily loaded contacts

An empirical elastohydrodynamic (EHD) film thickness formula for predicting the minimum film thickness occurring within heavily loaded contacts (maximum Hertz stresses above 1.04 GN/sq m (150,000 psi)) was developed. The formula was based upon X-ray film thickness measurements made with synthetic paraffinic, fluorocarbon, Type II ester, and polyphenyl ether fluids covering a wide range of test conditions. Comparisons were made between predictions from an isothermal EHD theory and the test data. The deduced relationship was found to adequately reflect the high-load dependence exhibited by the measured data. The effects of contact geometry, material, and lubricant properties on the form of the empirical model are also discussed.

Loewenthal, S. H.↗

Microgravity Emissions Laboratory Testing of the Light Microscopy Module Control Box Fan

The Microgravity Emissions Laboratory (MEL) was developed at the NASA Glenn Research Center for the characterization, simulation, and verification of the International Space Station (ISS) microgravity environment. This Glenn lab was developed in support of the Fluids and Combustion Facility (FCF). The MEL is a six-degrees-of-freedom inertial measurement system that can characterize the inertial response forces (emissions) of components, subrack payloads, or rack-level payloads down to 10 7g. The inertial force output data generated from the steady-state or transient operations of the test article are used with finite element analysis, statistical energy analysis, and other analysis tools to predict the on-orbit environment at specific science or rack interface locations. Customers of the MEL have used benefits in isolation performance testing in defining available attenuation during the engineering hardware design phase of their experiment s development. The Light Microscopy Module (LMM) Control Box (LCB) fan was tested in the MEL in June and July of 2002. The LMM is planned as a remotely controllable on-orbit microscope subrack facility that will be accommodated in an FCF Fluids Integrated Rack on the ISS. The disturbances measured in the MEL test resulted from operation of the air-circulation fan within the LCB. The objectives of the testing were (1) to identify an isolator to be added to the LCB fan assembly to reduce fan-speed harmonics and (2) to identify the fan-disturbance forcing functions for use in rack-response analysis of the LMM and Fluids Integrated Rack facility. This report describes the MEL, the testing process, and the results from ground-based MEL LCB fan testing.

McNelis, Anne M.↗

Some new results concerning the dynamic behavior of annular turbulent seals

The dynamic characteristics of annular turbulent seals applied in high pressure turbopumps can be described by stiffness, damping, and inertia coefficients. An improved procedure is presented for determining these parameters by using measurements made with newly developed test equipment. The dynamic system seal, consisting of the fluid between the cylindrical surfaces of the rotating shaft and the housing, is excited by test forces (input), and the relative motion between the surfaces (output) is measured. Transformation of the input and output time signals into the frequency domain leads to frequency response functions. An analytical model, depending on the seal parameters, is fitted to the measured data in order to identify the dynamic coefficients. Some new results are reported that show the dependencies of these coefficients with respect to the axial and radial Reynolds numbers and the geometrical data of the seal.

Massmann, H.↗

Hypersonic Magneto-Fluid-Dynamic Compression in Cylindrical Inlet

Hypersonic magneto-fluid-dynamic interaction has been successfully performed as a virtual leading-edge strake and a virtual cowl of a cylindrical inlet. In a side-by-side experimental and computational study, the magnitude of the induced compression was found to be depended on configuration and electrode placement. To better understand the interacting phenomenon the present investigation is focused on a direct current discharge at the leading edge of a cylindrical inlet for which validating experimental data is available. The present computational result is obtained by solving the magneto-fluid-dynamics equations at the low magnetic Reynolds number limit and using a nonequilibrium weakly ionized gas model based on the drift-diffusion theory. The numerical simulation provides a detailed description of the intriguing physics. After validation with experimental measurements, the computed results further quantify the effectiveness of a magnet-fluid-dynamic compression for a hypersonic cylindrical inlet. At a minuscule power input to a direct current surface discharge of 8.14 watts per square centimeter of electrode area produces an additional compression of 6.7 percent for a constant cross-section cylindrical inlet.

Shang, Joseph S.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using "Braslet-M" Occlusion Cuffs

BACKGROUND: The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, nasal congestion, and headache. This experiment examined the responses to modified Valsalva and Mueller maneuvers as measured by cardiac and vascular ultrasound in a baseline microgravity steady state, and under the influence of thigh occlusion cuffs (Braslet cuffs). METHODS: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 46 days after launch (mean SD; 33 - 185). 27 cardiac and vascular parameters were obtained under three respiratory conditions (baseline, Valsalva, and Mueller) before and after tightening of the Braslet cuffs for a total of 162 data points per session. The quality of cardiac and vascular ultrasound examinations was assured through remote monitoring and guidance by Investigators from the NASA Telescience Center in Houston, TX, USA. RESULTS: Fourteen of the 81 measured conditions were significantly different with Braslet application and were apparently related to cardiac preload reduction or increase in the venous volume sequestered in the lower extremity. These changes represented 10 of the 27 parameters measured. In secondary analysis, 7 of the 27 parameters were found to respond differently to respiratory maneuvers depending on the presence or absence of thigh compression, with a total of 11 differences. CONCLUSIONS: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts proportionate measurable effects on cardiac performance in microgravity. Ultrasound techniques measuring the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an effective tool in determining the volume status of a cardiac or hemodynamically compromised patient in microgravity.

Hamilton, D. R.↗

Parametric performance of extruded axial grooved heat pipes from 100 to 300 K

Extensive performance data derived from tests with an aluminum axial grooved extruded heat pipe is presented for oxygen, methane, ethane, and ammonia as working fluids. The effects of operating temperature, fluid inventory, heat flux, and elevation on the transport capability and the evaporator and condenser film coefficients are measured and compared to theory. The data correlation indicates that, in addition to the viscous pressure drop of the fluid, a vapor induced liquid pressure drop must be taken into account at temperatures near or below the normal boiling point of the fluid. Methane, ethane, and ammonia are all suitable working fluids for this groove geometry; however, oxygen, because of its low static height, is at best marginal in the 100-120 K range.

Schlitt, K. R.↗

NASA Fluid Lensing & MiDAR: Next-Generation Remote Sensing Technologies for Aquatic Remote Sensing

We present two recent instrument technology developments at NASA, Fluid Lensing and MiDAR, and their application to remote sensing of Earth's aquatic systems. Fluid Lensing is the first remote sensing technology capable of imaging through ocean waves in 3D at sub-cm resolutions. MiDAR is a next-generation active hyperspectral remote sensing and optical communications instrument capable of active fluid lensing. Fluid Lensing has been used to provide 3D multispectral imagery of shallow marine systems from unmanned aerial vehicles (UAVs, or drones), including coral reefs in American Samoa and stromatolite reefs in Hamelin Pool, Western Australia. MiDAR is being deployed on aircraft and underwater remotely operated vehicles (ROVs) to enable a new method for remote sensing of living and nonliving structures in extreme environments. MiDAR images targets with high-intensity narrowband structured optical radiation to measure an objectâ€"TM"s non-linear spectral reflectance, image through fluid interfaces such as ocean waves with active fluid lensing, and simultaneously transmit high-bandwidth data. As an active instrument, MiDAR is capable of remotely sensing reflectance at the centimeter (cm) spatial scale with a signal-to-noise ratio (SNR) multiple orders of magnitude higher than passive airborne and spaceborne remote sensing systems with significantly reduced integration time. This allows for rapid video-frame-rate hyperspectral sensing into the far ultraviolet and VNIR wavelengths. Previously, MiDAR was developed into a TRL 2 laboratory instrument capable of imaging in thirty-two narrowband channels across the VNIR spectrum (400-950nm). Recently, MiDAR UV was raised to TRL4 and expanded to include five ultraviolet bands from 280-400nm, permitting UV remote sensing capabilities in UV A, B, and C bands and enabling mineral identification and stimulated fluorescence measurements of organic proteins and compounds, such as green fluorescent proteins in terrestrial and aquatic organics.

fluid lensing↗

Effects of Shrouded Stator Cavity Flows on Multistage Axial Compressor Aerodynamic Performance

Experiments were performed on a low-speed multistage axial-flow compressor to assess the effects of shrouded stator cavity flows on aerodynamic performance. Five configurations, which involved changes in seal-tooth leakage rates and/or elimination of the shrouded stator cavities, were tested. Data collected enabled differences in overall individual stage and the third stage blade element performance parameters to be compared. The results show conclusively that seal-tooth leakage ran have a large impact on compressor aerodynamic performance while the presence of the shrouded stator cavities alone seemed to have little influence. Overall performance data revealed that for every 1% increase in the seal-tooth clearance to blade-height ratio the pressure rise dropped up to 3% while efficiency was reduced by 1 to 1.5 points. These observed efficiency penalty slopes are comparable to those commonly reported for rotor and cantilevered stator tip clearance variations. Therefore, it appears that in order to correctly predict overall performance it is equally important to account for the effects of seal-tooth leakage as it is to include the influence of tip clearance flows. Third stage blade element performance data suggested that the performance degradation observed when leakage was increased was brought about in two distinct ways. First, increasing seal-tooth leakage directly spoiled the near hub performance of the stator row in which leakage occurred. Second, the altered stator exit now conditions caused by increased leakage impaired the performance of the next downstream stage by decreasing the work input of the downstream rotor and increasing total pressure loss of the downstream stator. These trends caused downstream stages to progressively perform worse. Other measurements were acquired to determine spatial and temporal flow field variations within the up-and-downstream shrouded stator cavities. Flow within the cavities involved low momentum fluid traveling primarily in the circumferential direction at about 40% of the hub wheel speed. Measurements indicated that the flow within both cavities was much more complex than first envisioned. A vortical flow structure in the meridional plane, similar to a driven cavity, existed within the upstream cavity Furthermore, other spatial and temporal variations in Row properties existed. the most prominent being caused by the upstream potential influence of the downstream blade. This influence caused the fluid within cavities near the leading edges of either stator blades in space or rotor blades in time to be driven radially inward relative to fluid near blade mid-pitch. This influence also produced large unsteady velocity fluctuations in the downstream cavity because of the passing of the downstream rotor blade.

Wellborn, Steven R.↗

Evaluation of a hybrid hydrostatic bearing for cryogenic turbopump application

A hybrid hydrostatic bearing was designed to operate in liquid hydrogen at speeds to 80,000 rpm and radial loads to 440 n (100 lbf). The bearing assembly consisted of a pair of 20-mm angular-contact ball bearings encased in a journal, which was in turn supported by a fluid film of liquid hydrogen. The size and operating conditions of the bearing were selected to be compatible with the operating requirements of an advanced technology turbopump. Several test parameters were varied to characterize the bearing's steady-state operation. The rotation of the tester shaft was varied between 0 and 80,000 rpm. Bearing inlet fluid pressure was varied between 2.07 and 4.48 MPa (300 and 650 psia), while the fluid sump pressure was independently varied between 0.34 and 2.07 MPa (50 and 300 psia). The maximum radial load applied to the bearing was 440 N (110 lbf). Measured hybrid-hydrostatic-bearing stiffness was 1.5 times greater than predicted, while the fluid flow rate through the bearing was 35 to 65 percent less than predicted. Under two-phase fluid conditions, the stiffness was even greater and the flow rate was less. The optimal pressure ratio for the bearing should be between 0.2 and 0.55 depending on the balance desired between bearing efficiency and stiffness. Startup and shutdown cyclic tests were conducted to demonstrate the ability of the hybrid-hydrostatic-bearing assembly to survive at least a 300-firing-duty cycle. For a typical cycle, the shaft was accelerated to 50,000 rpm in 1.8 sec. The bearing operated for 337 start-stop cycles without failure.

Spica, P. W.↗

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing↗

Fluid and protein shifts after postural changes in humans

The effects of head-up, one-step, slow-graded, and rapid-graded tilt positions on blood density (BD), plasma density (PD), and erythrocyte density (ED) in male and female subjects are evaluated using a mass density detection method. The preparation of the samples and procedures for density and hematocrit measurements are described. The formula for calculating the density and volume of fluid shifted between intravascular and extravascular compartments is derived. The data reveal that ED does not change with varying tilt positions; however, PD and BD increase linearly with increasing angles of tilt, thereby resembling the time course of hemodilution and hemoconcentration.

Hinghofer-Szalkay, H.↗

Clinopyroxene REE distribution coefficients for shergottites The REE content of the Shergotty melt

Rare-earth element (REE) distribution coefficients were measured between synthetic pyroxenes and melts similar in composition to the Shergotty intercumulus fluid. REE-doped synthetic glass samples were analyzed by means of an automated microbeam electron microprobe. The coefficients were found to exhibit a strong positive correlation with pyroxene wollastonite content. Using distribution coefficients measured for the natural phase compositions, REE abundances for the Shergotty intercumulus melt were computed.

Mckay, G.↗

Raman Temperature and Density Measurements in Supersonic Jets

Prediction of flow-field properties in supersonic jets using computational fluid dynamics (CFD) code predictions has become routine; however, obtaining accurate solutions becomes more challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are significant. Benchmark sets of flow field property data are required in order to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of temperatures and turbulent heat flux is important. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering (SRS) spectroscopy and Background Oriented Schlieren (BOS) have been previously used to acquire measurements of the mean and root mean square (rms) velocities, the mean and rms gas temperatures and density gradients in subsonic jet flows and film cooling flows. In this work, the ability to measure density is added to the list of measurands available using the acquired Raman spectra. The suite of measurement techniques are now applied to supersonic jet flows. The computation of the local gas pressure in the potential core of an over-expanded jet is demonstrated using the Raman measured gas temperature and density. Additionally, a unique density feature in temperature matched, perfectly expanded jet flow shear layers identified using BOS was verified using the Raman measurement technique. These non-intrusive flow measurements are compared against RANS predictions of the supersonic jet flow properties as a means of assessing their prediction accuracy.

Raman Spectroscopy↗

Inflight Parachute Measurement Challenge

The Purpose of the Inflight Parachute Measurement Challenge is to solicit potential measurement solutions that can result in successful parachute loading assumption validation, along with validation of Fluid-Structure Interaction (FSI) simulations. A parachute system contains many components which see various loading conditions including tension and aerodynamic pressure forces. While measurements can be made in wind tunnels, significant limitations exist as compared to flight testing which include scaling, dynamic pressure time history, and cluster behavior. Traditional flight test instrumentation is difficult due the flexible nature of parachute components, packing requirements, and high forces and chaos during deployment. The Objectives of this challenge are to (1) describe the anatomy and behavior of parachute systems, (2) identify measurements of particular interest to the parachute design and analysis community, (3) identify additional uses of measurements such as FSI validation.

Daum, Jared↗