Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Volt-per-Ångstrom terahertz fields from X-ray free-electron lasers

The electron linear accelerators driving modern X-ray free-electron lasers can emit intense, tunable, quasi-monochromatic terahertz (THz) transients with peak electric fields of V Å -1 and peak magnetic fields in excess of 10 T when a purpose-built, compact, superconducting THz undulator is implemented. New research avenues such as X-ray movies of THz-driven mode-selective chemistry come into reach by making dual use of the ultra-short GeV electron bunches, possible by a rather minor extension of the infrastructure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A versatile X-ray phase retarder for lock-in XMCD measurements

X-ray magnetic circular dichroism (XMCD) is a technique commonly used to probe magnetic properties of materials with element and orbital selectivity, which requires the use of circularly polarized (CP) X-rays. It is possible to accomplish XMCD experiments with fixed CP and alternating the magnetic field orientation, but most reliable data are obtained when alternating the magnetization orientation and the polarization between right and left helicities. A versatile strategy has been developed to perform XMCD experiments using a hard X-ray quarter-wave plate, at both polychromatic dispersive and conventional monochromatic optics, in combination with synchronous data acquisition. The switching frequency waveform is fed into a lock-in amplifier to detect and amplify the XMCD signal. The results on a reference sample demonstrate an improvement in data quality and acquisition time. The instrumentation successfully generated 98% of CP X-rays switching the beam helicity at 13 Hz, with the possibility of faster helicity switching once it is installed at the new Brazilian fourth-generation source, SIRIUS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The New Structural Materials Science Beamlines BL8A and 8B at Photon Factory

BL8A and 8B are new beamlines for structural materials science at Photon Factory. The primary characteristics of both beamlines are similar. The incident beam is monochromatized by the Si(111) double-flat crystal monochromator and focused at the sample position by a Rh-coated bent cylindrical quartz mirror. The Weissenberg-camera-type imaging-plate (IP) diffractometers were installed. The X-ray diffraction experiments for structural studies of strongly correlated materials, such as transition metals, molecular conductors, endohedral fullerenes, nano-materials, etc, are conducted at these stations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved imaging of atoms and molecules in laser-produced uranium plasmas

Gas-phase oxidation of uranium (U), plume chemistry, and its impact on optical emission features of the uranium plasma are investigated. Plasmas were produced via nanosecond laser ablation of a natural uranium target in a chamber where uranium oxidation was controlled by varying the oxygen partial pressure within argon cover gas. Monochromatic imaging of uranium atoms and monoxide molecules was performed using narrowband optical filters, which clearly reveals the spatio-temporal evolution of these species in the plasma. Uranium oxides are found to be formed at the plasma edges, where lower temperatures favor molecular recombination. Segregation between the distribution of uranium atoms and monoxide species is observed at later times of plasma evolution, and is more apparent at lower oxygen partial pressures. At higher oxygen partial pressures, significant variation in plume morphology is noticed for UO species, which is attributed to higher rate of oxide (UxOy) formation at the plume edges. The monochromatic images of U atoms and molecules and corresponding spectral features at various oxygen partial pressures presented here provide a unique insight into gas-phase, high-temperature uranium oxidation, and its chemistry and have implications for a wide range of nuclear applications, from stand-off detection of radioisotopes to forensics and safeguards.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of bent-crystal x-ray microscopes for high energy density physics research

We present calculations for the field of view (FOV), image fluence, image monochromaticity, spectral acceptance, and image aberrations for spherical crystal microscopes, which are used as self-emission imaging or backlighter systems at large-scale high energy density physics facilities. Our analytic results are benchmarked with ray-tracing calculations as well as with experimental measurements from the 6.151 keV backlighter system at Sandia National Laboratories. Furthermore, the analytic expressions can be used for x-ray source positions anywhere between the Rowland circle and object plane. We discovered that this enables quick optimization of the performance of proposed but untested, bent-crystal microscope systems to find the best compromise between FOV, image fluence, and spatial resolution for a particular application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-Intensity High-order Harmonics Generated from Low-Density Plasma

We study the generation of high-order harmonics from lowly ionized plasma, using the 10 TW, 10 Hz laser of the Advanced Laser Light Source (ALLS). We perform detailed studies on the enhancement of a single order of the high-order harmonic spectrum generated in plasma using the fundamental and second harmonic of the ALLS beam line. We observe quasi-monochromatic harmonics for various targets, including Mn, Cr, Sn, and In. We identify most of the ionic/neutral transitions responsible for the enhancement, which all have strong oscillator strengths. We demonstrate intensity enhancements of the 13th, 17th, 29th, and 33rd harmonics from these targets using the 800 nm pump laser and varying its chirp. We also characterized the attosecond nature of such plasma harmonics, measuring attosecond pulse trains with 360 as duration for chromium plasma, using the technique of 'Reconstruction of Attosecond Beating by Interference of Two-photon Transitions'(RABBIT). These results show that plasma harmonics are intense source of ultrashort coherent soft x-rays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isotope-selective radiography and material assay using high-brilliance, quasi-monochromatic, high-energy photons

We demonstrate the possibility to directly detect microgram amounts of the isotope 7 Li using a quasi-monochromatic high-energy photon beam. The isotope selective detection is based on a witness scatterer absorbing and re-emitting photons via nuclear resonance fluorescence. This enables the detection of isotopes with microgram accuracy at long distances from the actual sample. Further, we demonstrate that the technique can deliver quantitative information without specific knowledge of the photon flux and no spectral capabilities or knowledge of the resonance fluorescence cross section. Detection of low-atomic-weight isotopes screened by heavy shielding is also shown. The techniques described are applicable to all next-generation, ultrahigh brilliance, laser-Compton light sources currently under construction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulations of Ultra-High Energy Resolution Gamma Detectors for Nuclear Safeguards

Ultra-high energy resolution superconducting gamma-ray detectors can improve the accuracy of non-destructive analysis for unknown radioactive materials. These detectors offer an order of magnitude improvement in resolution over conventional high purity germanium detectors. The increase in resolution reduces errors from line overlap and allows for the identification of weaker gamma-rays by increasing the magnitude of the peaks above the background. In order to optimize the detector geometry and to understand the spectral response function Geant4, a Monte Carlo simulation package coded in C++, was used to model the detectors. Using a 1 mm{sup 3} Sn absorber and a monochromatic gamma source, different absorber geometries were tested. The simulation was expanded to include the Cu block behind the absorber and four layers of shielding required for detector operation at 0.1 K. The energy spectrum was modeled for an Am-241 and a Cs-137 source, including scattering events in the shielding, and the results were compared to experimental data. For both sources the main spectral features such as the photopeak, the Compton continuum, the escape x-rays and the backscatter peak were identified. Finally, the low energy response of a Pu-239 source was modeled to assess the feasibility of Pu-239 detection in spent fuel. This modeling of superconducting detectors can serve as a guide to optimize the configuration in future spectrometer designs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cationic Dependence of X-ray Induced Damage in Strontium and Barium Nitrate

The response of solids to x-ray irradiation is not well understood, in part, because the interactions between x-rays and molecules in solids depend on the intra- and/or inter-molecular electronic properties of the material. Our previous work demonstrated that x-ray induced damage of certain ionic salts depends on the irradiating photon energy, especially when irradiated with photons of energy near the cation’s K-edge. To advance understanding of the cationic dependence of x-ray photochemistry, we present studies of x-ray induced damage of barium nitrate and strontium nitrate. Polycrystalline samples of barium and strontium nitrate were irradiated with high flux monochromatic synchrotron x-rays at selected energies near the K-edge of the respective cations. The damage processes were studied with powder x-ray diffraction, and irradiation products, NO 2 and O 2 , were characterized via Raman spectroscopy. Our results demonstrate that irradiating barium and strontium nitrate with photons of energy greater than the K-edge of the cation promotes high rate of decomposition compared to that observed when irradiating with photons of energy below the K-edge. Additionally, differences in x-ray induced damage between the two compounds are examined and discussed, and evidence of the diffusion of irradiation products is presented.

36 MATERIALS SCIENCE↗

Physical conditions for UO formation in laser-produced uranium plumes

Laser-induced plasma spectroscopy is a powerful method for elemental detection and analysis, however the broadening and merging of densely packed spectral lines can make it especially challenging for studying high-Z elements such as uranium and other actinides. In order to understand the processes occurring in laser-induced plasma, it is necessary to evaluate the variation of its thermodynamic parameters. We performed spatiotemporal diagnostics of uranium species in plasma plumes produced by nanosecond near-infrared laser pulses in low- pressure environment. Spatially- and temporally-resolved emission spectroscopy experiments are supported by modeling of uranium emission and its persistence in the plume. Saha-Eggert equation as well as Boltzmann diagrams generated from numerous U I transitions are used to infer temperature. We report the rst measurements of uranium Stark broadening parameters for U I 499.01 nm and U II 500.82 nm transitions. The Stark widths of selected U transitions were measured by comparing their linewidths with the broadening of O I 777.19 nm line. Electron density was found to be on the order of 1016 cm??3, while the temperature was found to be in the range of 3000{8000 K. In addition to enhancing the fundamental understanding of high-Z plasmas under reduced-pressure environments, the knowledge of Stark broadening parameters could improve modeling capabilities and analytical performance of techniques that rely on emission plasma spectroscopy.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Ultra-precision fabrication of 500 mm long and laterally graded Ru/C multilayer mirrors for X-ray light sources

X-ray mirrors are needed for beam shaping and monochromatization at advanced research light sources, for instance, free-electron lasers and synchrotron sources. Such mirrors consist of a substrate and a coating. The shape accuracy of the substrate and the layer precision of the coating are the crucial parameters that determine the beam properties required for various applications. In principal, the selection of the layer materials determines the mirror reflectivity. A single layer mirror offers high reflectivity in the range of total external reflection, whereas the reflectivity is reduced considerably above the critical angle. A periodic multilayer can enhance the reflectivity at higher angles due to Bragg reflection. Here, the selection of a suitable combination of layer materials is essential to achieve a high flux at distinct photon energies, which is often required for applications such as microtomography, diffraction, or protein crystallography. This contribution presents the current development of a Ru/C multilayer mirror prepared by magnetron sputtering with a sputtering facility that was designed in-house at the Helmholtz-Zentrum Geesthacht. The deposition conditions were optimized in order to achieve ultra-high precision and high flux in future mirrors. Input for the improved deposition parameters came from investigations by transmission electron microscopy. The X-ray optical properties were investigated by means of X-ray reflectometry using Cu- and Mo-radiation. The change of the multilayer d-spacing over the mirror dimensions and the variation of the Bragg angles were determined. The results demonstrate the ability to precisely control the variation in thickness over the whole mirror length of 500 mm thus achieving picometer-precision in the meter-range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Region Extent Assessment with X-rays (AREA-X)

The development of semiconductor sensors for new particle tracking detectors places increasing limits on sensor characteristics such as uniformity, size and shape of inefficient areas and size of active compared to inactive sensor areas. Accurately assessing these relatively subtle effects requires either measurements in particle beams or the modification of samples to be used in dedicated laser test setups. Active Region Extent Assessment with X-rays (AREA-X) has been developed as an alternative method for the fast, efficient and precise study of the active area of a semiconductor sensor. It uses a monochromatic, micro-focused X-ray beam with a 10–20 keV energy range as provided by several synchrotron beam lines and uses the photo current induced in the sensor to measure the depth of the responsive sensor volume. It can be used to study local inhomogeneities or inefficiencies, the overall extent of the active sensor volume and its shape and its localised application, which makes the need to gather statistics over a large area unnecessary, allowing for fast readout, which enables studies of the sensor behaviour at a range of external parameters, e.g. temperature or applied bias voltage. This paper presents the measurement concept and technical setup of the measurement, results from initial measurements as well as capabilities and limitations of the method.

47 OTHER INSTRUMENTATION↗

Fermi LAT Search for Photon Lines from 30 to 200 GeV

Dark matter (DM) particle annihilation or decay can produce monochromatic {gamma}-rays readily distinguishable from astrophysical sources. {gamma}-ray line limits from 30 GeV to 200 GeV obtained from 11 months of Fermi Large Area Space Telescope data from 20-300 GeV are presented using a selection based on requirements for a {gamma}-ray line analysis, and integrated over most of the sky. We obtain {gamma}-ray line flux upper limits in the range 0.6-4.5 x 10{sup -9} cm{sup -2}s{sup -1}, and give corresponding DM annihilation cross-section and decay lifetime limits. Theoretical implications are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoneutron reaction cross section measurements on Mo 94 and Zr 90 relevant to the p -process nucleosynthesis

The photodisintegration cross sections for the 94 Mo(γ,n) and 90 Zr(γ,n) reactions have been experimentally investigated with quasi-monochromatic photon beams at the High Intensity γ-ray Source (HIγS) facility of the Triangle Universities Nuclear Laboratory (TUNL). The energy dependence of the photoneutron reaction cross sections was measured with high precision from the respective neutron emission thresholds up to 13.5 MeV. Here, these measurements contribute to a broader investigation of nuclear reactions relevant to the understanding of the p-process nucleosynthesis. The results are compared with the predictions of Hauser-Feshbach statistical model calculations using two different models for the dipole γ-ray strength function. Lastly, the resulting 94 Mo(γ,n) and 90 Zr(γ,n) photoneutron stellar reaction rates as a function of temperature in the typical range of interest for the p-process nucleosynthesis show how sensitive the photoneutron stellar reaction rate can be to the experimental data in the vicinity of the neutron threshold.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Depth-resolved ultra-violet spectroscopic photo current-voltage measurements for the analysis of AlGaN/GaN high electron mobility transistor epilayer deposited on Si

We have demonstrated that the depth-dependent defect distribution of the deep level traps in the AlGaN/GaN high electron mobility transistor (HEMT) epi-structures can be analyzed by using the depth-resolved ultra-violet (UV) spectroscopic photo current-voltage (IV) (DR-UV-SPIV). It is of great importance to analyze deep level defects in the AlGaN/GaN HEMT structure, since it is recognized that deep level defects are the main source for causing current collapse phenomena leading to reduced device reliability. The AlGaN/GaN HEMT epi-layers were grown on a 6 in. Si wafer by metal-organic chemical vapor deposition. The DR-UV-SPIV measurement was performed using a monochromatized UV light illumination from a Xe lamp. The key strength of the DR-UV-SPIV is its ability to provide information on the depth-dependent electrically active defect distribution along the epi-layer growth direction. The DR-UV-SPIV data showed variations in the depth-dependent defect distribution across the wafer. As a result, rapid feedback on the depth-dependent electrical homogeneity of the electrically active defect distribution in the AlGaN/GaN HEMT epi-structure grown on a Si wafer with minimal sample preparation can be elucidated from the DR-UV-SPIV in combination with our previously demonstrated spectroscopic photo-IV measurement with the sub-bandgap excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗