Search NASASearch

SEARCH · Search NASA

Results for “Technology Demonstration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,296 records · Page 50

Electrochemical Deconstruction of Ortho-Phthalate Plasticizers and Recovery of Plasticizing Moieties

Electrochemical methods for the direct reduction of alkyl esters have been understudied but provide a potential advantage for addressing specific waste streams given that such strategies often require only a minimal chemical profile. One such waste stream that could benefit from electrochemical remediation is poly(vinyl chloride) (PVC) plastics. PVC recycling often faces challenges due to the complexity of such waste. Solvent-based recycling methods pose several advantages for addressing post-use PVC; however, such methods are complicated by the high amounts of toxic legacy plasticizers (ortho-phthalates) present in PVC. A potential solution to addressing such phthalates is to address them electrochemically, coupled with recovery of the resulting valuable products. Presented herein is an optimized electrochemical method for ester activation that is leveraged to separate and recover the aromatic and alkyl components of ortho-phthalate plasticizers. The resulting aliphatic alcohols may be reused to prepare other non-toxic plasticizers. This electro-degradation method is demonstrated on six phthalates that have been identified to pose health concerns in addition to plasticizers recovered from commercial samples of PVC.

di-(2-ethylhexyl) phthalate

Characterizing the subglacial environment of lower Thwaites Glacier using radar modeling

Understanding the spatial heterogeneity beneath Thwaites Glacier, West Antarctica, is vital to projecting its impact on future sea levels. Radar-echo sounding (RES) is commonly used to infer subglacial conditions, but these data can be challenging to interpret. We assess basal heterogeneity across Thwaites Glacier by comparing RES returns to a radar backscattering simulator for over 400 km of RES data. The modeled variations in bed returned power exhibited a strong correlation with actual RES data in 40% of our simulated flight segments, which we consider evidence for a relatively homogeneous glacier bed. Other sites (40%) demonstrated improved fit quality when hydrology or substrate transitions were introduced in the bed material model. The remaining simulated segments (20%) were diagnosed as having more complex basal heterogeneity. The spatial distribution of complex heterogeneity appears to coincide with asymmetric patterns in the RES specularity content, which has been interpreted in previous studies as a signature for channelized hydrology. Conversely, the homogeneous substrate locations coincide with areas of fast-moving ice in western Thwaites. Our simulation method can isolate power variations induced by material heterogeneity vs topography, which is an important limitation of existing RES analysis methods.

Antarctic glaciology

An Investigation Regarding the Effects of Volume Dynamics on Gas Turbine Engine Performance and Operability

This work explores the impact of adding volume dynamics to an electrified turbofan engine model. The zero-dimensional single-input single-output volume elements capture the physics of fluid compressibility of flow in the engine core gas path turbomachinery during transient operation with greater fidelity. Some background regarding the motivation for this effort is provided. A model of the volume element is developed from first principles. The baseline engine model is described and an explanation is given of the modifications made to incorporate the volume elements into the new model. Details of the simulated inputs, designed to elicit exaggerated dynamic responses and to facilitate comparison between the baseline and modified engine models, are explicated. The results of these simulations are presented and discussed, demonstrating that the transient performance and operability of the modified engine model, measured by parameters such as shaft speeds, thrust, and high-pressure compressor (HPC) stall margin, are impacted by the additional dynamics. Commentary is provided regarding potential explanations for the differences in behavior exhibited by the two models. Finally, suggestions are offered for future work that might improve the volume models developed in this effort and leverage the improved fidelity enabled by the modeling of turbomachinery volume dynamics.

Volume dynamics

Hematite Is a Mineralogical Marker of Ancient Climate Change on Mars

The ancient climate of Mars changed from warm to cold surface conditions. This climate transition is demonstrated by geomorphological evidence, but lacks suitable mineralogical indicators. We investigate the crystallographic properties of hematite (iron oxide) in Gale crater, measured by the Curiosity rover, and compare them to laboratory experiments. Hematite crystallite sizes are ~5 to ~65 nm in the oldest sedimentary rocks investigated by the rover (the Murray formation) and <10 nm in the younger overlying strata (Mirador and Carolyn Shoemaker formations). We attribute the larger crystallites in the Murray formation to post-depositional coarsening by groundwater in warm and wet conditions, which persisted for several million years. Hematite with small crystallites co-occurs with goethite (iron oxyhydroxide) in the overlying layers, consistent with colder and water- limited conditions.

Marek Szczerba

Tidal Tomography Reveals a Thermal Anomaly Beneath Mars’s Crustal Dichotomy

Mars undergoes seasonal tidal forcing as a result of its eccentric orbit and the tilt of its rotation axis relative to the Sun1. Response to this forcing produces temporal variations in the Martian gravity field and is sensitive to the internal structure of the planet2,3,4. Using tracking data from the Mars Global Surveyor (MGS), Mars Odyssey (ODY) and Mars Reconnaissance Orbiter (MRO) spacecraft5,6,7, we demonstrate that degree-3 components of the time-variable gravity field of Mars differ by up to 300% from predictions for a spherically symmetric planet8,9,10. These deviations can be explained if the effective shear modulus of the mantle varies by >20% over a roughly north–south pattern that closely aligns with the surface expression of the Martian crustal dichotomy11. On the basis of this correlation, we infer preservation of a 200–400 °C thermal anomaly in the present-day mantle below the southern highlands of Mars. This temperature variation could reflect regional mantle convection12,13 or insulation by the thick southern highlands crust of Mars that has persisted over several billion years14,15.

Mars

Strategic Melamine Coating on Lithium Metal for Li 3 N-Rich Solid Electrolyte Interphase and Improved Battery Cycling Stability

The practical applications of lithium (Li) metal batteries (LMBs) are limited by challenges such as dendrite formation and unstable solid electrolyte interphase (SEI), especially at higher C-rates. Here, this study introduces melamine-coated Li metal anodes (LMAs), forming a Li 3 N-rich SEI layer that improves ionic conductivity and mechanical stability. The optimized melamine-coated LMA demonstrated uniform coverage resulting in denser Li deposition, nearly doubled cycle life (~148 cycles at 0.5 C, 1C = 4.1 mA cm -2 ), compared to Bare-Li. These findings emphasize that coating materials-induced beneficial SEI components could lead to improvement of LMB performance.

Batteries

A survey of advanced battery systems for space applications

The results of a survey on advanced secondary battery systems for space applications are presented. Fifty-five battery experts from government, industry and universities participated in the survey by providing their opinions on the use of several battery types for six space missions, and their predictions of likely technological advances that would impact the development of these batteries. The results of the survey predict that only four battery types are likely to exceed a specific energy of 150 Wh/kg and meet the safety and reliability requirements for space applications within the next 15 years.

Attia, Alan I.

Effect of Composition Variation on Isothermal Rapid Curing Resins for Aerospace Applications

To meet the projected demand for single-aisle composite aircraft in 2040, the production rate of these aircraft will need to increase by four to six times what is currently achievable. A composite manufacturing process with the potential to enable the targeted rates is isothermal resin infusion where infusion and cure occur at the same temperature. However, presently there is not an accepted aerospace-grade resin that can support this isothermal infusion process and maintain acceptable resin properties. Therefore, resin development initiatives have designed anionic catalyzed epoxy systems capable of isothermal infusion and rapid cure at a temperature below 100 ˚C in one hour. High-performance aerospace properties are achieved after undergoing a freestanding post-cure. The resins facilitate faster, energy efficient production cycles by reducing the time and temperature required for cure and eliminating temperature ramps typically required of materials used in the aerospace industry. This work discusses several of the developed resin systems and the impact of varying composition on rheological, thermal, and mechanical properties. Carbon fiber composites were fabricated for one composition by resin transfer molding to demonstrate the potential of these isothermal, rapid cure systems for meeting industry needs.

resin transfer molding

Structure–Property Linkage in Alloys Using Graph Neural Network and Explainable Artificial Intelligence

Deep learning tools have recently shown significant potential for accelerating the prediction of microstructure–property linkage in materials. While deep neural networks like convolution neural networks (CNNs) can extract physics information from 3D microstructure images, they often require a large network architecture and substantial training time. In this research, we trained a graph neural network (GNN) using phase field generated microstructures of Ni-Al alloys to predict the evolution of mechanical properties. We found that a single GNN is capable of accurately predicting the strengthening of Ni-Al alloys with microstructures of varying sizes and dimensions, which cannot otherwise be done with a CNN. Additionally, GNN requires significantly less GPU utilization than CNN and offers more interpretable explanation of predictions using saliency analysis as features are manually defined in the graph. We also utilize explainable artificial intelligence tool Bayesian Inference to determine the coefficients in the power law equation that governs coarsening of precipitates. Overall, our work demonstrates the ability of the GNN to accurately and efficiently extract relevant information from material microstructures without having restrictions on microstructure size or dimension and offers an interpretable explanation.

Chemistry

Conformational Isomerization of Imide Anions Governs Solvation and Transport in Water-in-Salt Electrolytes

The behavior of highly concentrated electrolytes departs radically from the dilute-solution theory, yet the molecular origin of this transformation remains unresolved. Here, we identify the conformational isomerization of molecular ions as a decisive, previously unrecognized control parameter governing structure and transport in crowded aqueous electrolytes. Across a series of fluorosulfonimide anions, we show that increasing concentration drives a collective shift from extended transoid to compact cisoid conformers, revealed by small-angle X-ray scattering, vibrational spectroscopy, pulsed-field gradient NMR, and molecular dynamics simulations. This conformational transition triggers a collapse of the hydrogen-bonded water network and the emergence of densely packed ionic domains with confined water, producing a qualitative change in Li+ transport from solvent-mediated diffusion to network-confined hopping. Anion size and asymmetry systematically tune the onset of this transition, demonstrating that molecular geometry dictates mesoscale organization and dynamics in the ion-rich regime. Our results establish ion conformation, not merely composition or coordination, as a fundamental thermodynamic variable in concentrated solutions, providing a chemical framework that unifies solvation structure and transport in water-in-salt electrolytes and suggesting new principles for designing dense ionic media.

Nguyen, Huong TD

Artemis II Mission Performance of the Orion Active Thermal Control System

The Orion spacecraft has recently completed Artemis II, the first crewed mission around the moon in 54 years. This test flight demonstrated vehicle capability as the foundation for all future missions under the Artemis program. As a major system of Orion, the Active Thermal Control System (ATCS) successfully managed crew and vehicle heat loads to provide adequate cooling and thermal comfort for the duration of the Artemis II mission. Thermal control on the Orion vehicle is managed through two redundant cooling loops in the Crew Module (CM) that absorb heat loads from the cabin and Air Revitalization System (ARS) heat exchangers, the Liquid Cooling Garment (LCG) heat exchanger, and the avionics cold plates, and then transfer those heat loads to the Service Module (SM) radiator loops and/or the Phase Change Material (PCM) and ammonia boilers when required through thermal configuration or mission phase. During Artemis II, Orion did not necessitate any supplemental cooling from ammonia boilers until service module separation, allowing the maximum availability of ammonia cooling prior to entry. This presentation will provide an overview of the Orion ATCS major subsystems, highlight the performance during key mission phases, and comment on the applicability of the observed thermal response to future Artemis missions.

Ellie Thurston

Electronegativity-Guided Site Differentiation in High-Entropy Alloy for pH-universal Hydrogen Evolution Reactions

Enhancing the intrinsic activity of transition metal catalysts for the hydrogen evolution reaction (HER) remains a critical challenge in sustainable energy conversion. Herein, we report an electronegativity-guided site differentiation strategy in a single-phase CoNiCuMoW high-entropy alloy (HEA) via electrodeposition by incorporating high-electronegativity 4d/5d orbital transition metals (Mo, W) into the face-centered cubic (fcc) matrix (CoNiCu). The as-synthesized HEA demonstrates exceptional HER performance in all pH conditions, delivering an outstanding overpotential of 65 mV (alkaline), 28 mV (acidic), and 155 mV (neutral) at a current density of 100 mA cm−2, showing performance comparable to commercial Pt/C and has excellent long-term stability at high current density (1 A cm−2, 1000 h). X-Ray absorption spectroscopy (XAS) and density functional theory (DFT) calculations reveal that the incorporation of Mo/W simultaneously alters the local coordination environment and induces element-dependent charge redistribution, accompanied by a system-level d-band center downshift, thereby optimizing the hydrogen binding strength across multimetallic sites. Meanwhile, oxophilic Mo/W sites lower the water dissociation energy barrier. These synergistic effects collectively enable efficient and durable pH-universal HER performance.

Wu, Yutong

All-Polyester Multilayer Plastics (‘All-Polyester MLPs’): A Redesign for Inherently Recyclable Plastics

Multilayer plastics (MLPs) are widely used in modern packaging because they combine multiple functions such as oxygen and moisture barriers, mechanical strength, puncture resistance, and heat sealability into lightweight and cost-effective packaging solutions. These attributes are essential for food, beverage, pharmaceutical, and consumer goods packaging. However, conventional commercial MLPs typically consist of five to twelve layers made from chemically incompatible materials, including polyolefins, polyethylene terephthalate, nylon, ethylene-vinyl alcohol (EVOH), adhesives, and tie layers. This complexity makes MLPs extremely difficult to recycle. As a result, the vast majority of multilayer plastics (MLPs) are disposed of through landfilling or incineration. This disposal pathway perpetuates demand for virgin material production, thereby driving high industrial energy consumption, increasing greenhouse gas (GHG) emissions, and contributing to the long-term accumulation of plastic waste. The scope of work included: (1) Design and fabrication of all-polyester multilayer structures using commercially relevant processing methods; (2) Experimental validation of barrier, mechanical, and sealing performance; (3) Demonstration of both mechanical and chemical recycling pathways; and (4) Comprehensive techno-economic analysis (TEA) and life-cycle assessment (LCA) to quantify cost, energy, and environmental impacts.

36 MATERIALS SCIENCE

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Biochemical approaches for synthesis of performance-advantaged polymers from lignocellulosic biomass

Lignocellulose is an abundant renewable feedstock for production of sustainable fuels, chemicals, and materials. The structural complexity of lignocellulose provides key material properties and inspires the design of advanced materials. However, this same complexity also presents challenges for conversion of lignocellulosic biomass into new materials with consistent properties. Conventional physical and chemical strategies for valorization of biomass to new materials are often limited by the technical challenges of precisely manipulating complex feedstocks, sensitivity to feedstock variability, and associated costs. In contrast, biological approaches are capable of selectively manipulating complex architectures under mild conditions. Recent advances demonstrate the potential of biological and hybrid biochemical methods to tailor biomass-derived polymers and generate new materials. This review provides an overview of biological strategies to valorize lignocellulosic biomass into novel materials, highlighting approaches for in planta engineering, biochemical modification of natural biomass polymers, microbial funneling of deconstructed biomass, and direct biosynthesis of novel polymers. In combination, these approaches open new avenues for the synthesis of performance-advantaged materials from lignocellulosic biomass.

Qian, Liangyu [ORNL] (ORCID:0009000212029938)

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Cully Community Solar

This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.

14 SOLAR ENERGY

An attention-based neural ordinary differential equation framework for modeling inelastic processes

To preserve strictly conservative behavior as well as model the variety of dissipative behavior displayed by solid materials, we propose a significant enhancement to the internal state variable-neural ordinary differential equation (ISV-NODE) framework. In this data-driven, physics-constrained modeling framework internal states are inferred rather than prescribed. The ISV-NODE consists of: (a) a stress model dependent on observable deformation and inferred internal state, and (b) a model of the evolution of the internal states. The enhancements to ISV-NODE proposed in this work are multifold: (a) a partially input convex neural network stress potential provides polyconvexity in terms of observed strain while leaving the inferred state unconstrained, and (b) an internal state flow model uses common latent features to inform novel attention-based gating and drives the flow of internal state only in dissipative regimes. We demonstrated that this architecture can accurately model dissipative and conservative behavior across an isotropic, isothermal elastic-viscoelastic-elastoplastic spectrum with three exemplars, while maintaining fundamental principles by design.

97 MATHEMATICS AND COMPUTING