Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

TH-E-202-02: The Use of Hypoxia PET Imaging for Radiotherapy

PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.

60 APPLIED LIFE SCIENCES↗

TH-E-202-03: PET for Tumor Response Evaluation

PET/CT is a very important imaging tool in the management of oncology patients. PET/CT has been applied for treatment planning and response evaluation in radiation therapy. This educational session will discuss: Pitfalls and remedies in PET/CT imaging for RT planning The use of hypoxia PET imaging for radiotherapy PET for tumor response evaluation The first presentation will address the issue of mis-registration between the CT and PET images in the thorax and the abdomen. We will discuss the challenges of respiratory gating and introduce an average CT technique to improve the registration for dose calculation and image-guidance in radiation therapy. The second presentation will discuss the use of hypoxia PET Imaging for radiation therapy. We will discuss various hypoxia radiotracers, the choice of clinical acquisition protocol (in particular a single late static acquisition versus a dynamic acquisition), and the compartmental modeling with different transfer rate constants explained. We will demonstrate applications of hypoxia imaging for dose escalation/de-escalation in clinical trials. The last presentation will discuss the use of PET/CT for tumor response evaluation. We will discuss anatomic response assessment vs. metabolic response assessment, visual evaluation and semi-quantitative evaluation, and limitations of current PET/CT assessment. We will summarize clinical trials using PET response in guiding adaptive radiotherapy. Finally, we will summarize recent advancements in PET/CT radiomics and non-FDG PET tracers for response assessment. Learning Objectives: Identify the causes of mis-registration of CT and PET images in PET/CT, and review the strategies to remedy the issue. Understand the basics of PET imaging of tumor hypoxia (radiotracers, how PET measures the hypoxia selective uptake, imaging protocols, applications in chemo-radiation therapy). Understand the basics of dynamic PET imaging, compartmental modeling and parametric images. Understand the basics of using FDG PET/CT for tumor response evaluation. Learn about recent advancement in PET/CT radiomics and non-FDG PET tracers for response assessment. This work was supported in part by the National Cancer Institute Grants R01CA172638.; W. Lu, This work was supported in part by the National Cancer Institute Grants R01CA172638.

60 APPLIED LIFE SCIENCES↗

Methodolgy For Evaluation Of Technology Impacts In Space Electric Power Systems

The Analysis and Management branch of the Power and Propulsion Office at NASA Glenn Research Center is responsible for performing complex analyses of the space power and In-Space propulsion products developed by GRC. This work quantifies the benefits of the advanced technologies to support on-going advocacy efforts. The Power and Propulsion Office is committed to understanding how the advancement in space technologies could benefit future NASA missions. They support many diverse projects and missions throughout NASA as well as industry and academia. The area of work that we are concentrating on is space technology investment strategies. Our goal is to develop a Monte-Carlo based tool to investigate technology impacts in space electric power systems. The framework is being developed at this stage, which will be used to set up a computer simulation of a space electric power system (EPS). The outcome is expected to be a probabilistic assessment of critical technologies and potential development issues. We are developing methods for integrating existing spreadsheet-based tools into the simulation tool. Also, work is being done on defining interface protocols to enable rapid integration of future tools. Monte Carlo-based simulation programs for statistical modeling of the EPS Model. I decided to learn and evaluate Palisade's @Risk and Risk Optimizer software, and utilize it's capabilities for the Electric Power System (EPS) model. I also looked at similar software packages (JMP, SPSS, Crystal Ball, VenSim, Analytica) available from other suppliers and evaluated them. The second task was to develop the framework for the tool, in which we had to define technology characteristics using weighing factors and probability distributions. Also we had to define the simulation space and add hard and soft constraints to the model. The third task is to incorporate (preliminary) cost factors into the model. A final task is developing a cross-platform solution of this framework.

Holda, Julie↗

A Thermogravimetric Temperature-Programmed Thermal Redox Protocol for Rapid Screening of Metal Oxides for Solar Thermochemical Hydrogen Production

As combinatorial and computational methods accelerate the identification of potentially suitable thermochemically-active oxides for use in solar thermochemical hydrogen production (STCH), the onus shifts to quickly evaluating predicted performance. Traditionally, this has required an experimental setup capable of directly carrying out a two-stage thermochemical water-splitting process. But this can be a difficult endeavor, as most off-the-shelf equipment cannot adequately deal simultaneously with the high temperatures, varying oxygen partial pressures, and high H 2 O partial pressures required; achieving sufficient temporal sensitivity to accurately quantify the kinetics is also a major challenge. However, as proposed here, a less complicated experiment can be used as a first screening for thermochemical water splitting potential. Temperature-Programmed Thermal Redox (TPTR) using thermogravimetry evaluates the thermal reduction behavior of materials. This technique does not require water splitting or CO 2 -splitting analogs but can nonetheless predict water-splitting performance. Three figures of merit are obtained from the TPTR experiment: reduction onset temperature, extent of reduction, and extent of recovery upon reoxidation. These metrics can collectively be used to determine if a material is capable of thermochemical water-splitting, and, to good approximation, predict whether the thermodynamics are favorable for use under more challenging high-conversion conditions. This paper discusses the pros and cons of using TPTR and proposes a protocol for use within the STCH community.

08 HYDROGEN↗

SU-E-J-06: A Feasibility Study On Clinical Implementation of 4D-CBCT in Lung Cancer Treatment

Purpose: Four-dimensional cone-beam CT (4D-CBCT) is a novel imaging technique to setup patients with pulmonary lesions in radiation therapy. This paper is to perform a feasibility study on the implementation of 4D-CBCT as image guidance for (1) SBRT and (2) Low Modulation (Low-Mod) IMRT in lung cancer treatment. Methods: Image artifacts and observers variability are evaluated by analyzing the 4D-CT QA phantom and patient 4D image data. There are two 4D-CBCT image artifacts: (1) Spatial artifact caused by the patient irregular breathing pattern will generate blurring and anatomy gap/overlap; (2) Cone beam scattering and hardening artifact will affect the image spatial and contrast resolution. The couch shift varies between 1mm to 3mm from different observers during the 4D-CBCT registration. Breath training is highly recommended to improve the respiratory regularity during CT simulation and treatment, especially for SBRT. Elekta XVI 4.5 Symmetry protocol is adopted in the patient 4DCBCT scanning and intensity-based registration. Physician adjustments on the auto-registration are involved prior to the treatment. Physician peer review on 4D-CBCT image acquisition and registration is also recommended to reduce the inter-observer variability. The average 4D-CT in reference volume coordinates is exported to MIM Vista 5.6.2 to manually fuse to the planning CT for further evaluation. Results: (1) SBRT: 4DCBCT is performed in dry-run and in each treatment fraction. Image registration and couch shift are reviewed by another physician on the 1st fraction before the treatment starts. (2) Low-Mod IMRT: 4D-CBCT is performed and peer reviewed on weekly basis. Conclusion: 4D-CBCT in SBRT dry-run can discover the ITV discrepancies caused by the low quality 4D-CT simulation. 4D-CBCT during SBRT and Low-Mod IMRT treatment provides physicians more confidence to target lung tumor and capability to evaluate inter-fractional ITV changes. More advanced 4D-CBCT scan protocol and reconstruction algorithm may be needed in the future.

60 APPLIED LIFE SCIENCES↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

Blunt Chest Trauma: A Radiologic Approach and Review

Blunt chest trauma, a frequent component of trauma admissions, is the second leading cause of death in motor-vehicle accidents. Additionally, it may be associated with significant morbidity in those who survive. Radiography, ultrasonography, and computed tomography (CT) have a widespread role in evaluating blunt chest trauma, importantly aiding in the diagnosis and management of injury. Herein, we discuss the most common salient injuries, imaging protocol considerations and imaging findings associated with acute blunt chest trauma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sequencing of Local Therapy Affects the Pattern of Treatment Failure and Survival in Children With Atypical Teratoid Rhabdoid Tumors of the Central Nervous System

Purpose: To assess the pattern of treatment failure associated with current therapeutic paradigms for childhood atypical teratoid rhabdoid tumors (AT/RT). Methods and Materials: Pediatric patients with AT/RT of the central nervous system treated at our institution between 1987 and 2007 were retrospectively evaluated. Overall survival (OS), progression-free survival, and cumulative incidence of local failure were correlated with age, sex, tumor location, extent of disease, and extent of surgical resection. Radiotherapy (RT) sequencing, chemotherapy, dose, timing, and volume administered after resection were also evaluated. Results: Thirty-one patients at a median age of 2.3 years at diagnosis (range, 0.45-16.87 years) were enrolled into protocols that included risk- and age-stratified RT. Craniospinal irradiation with focal tumor bed boost (median dose, 54 Gy) was administered to 18 patients. Gross total resection was achieved in 16. Ten patients presented with metastases at diagnosis. RT was delayed more than 3 months in 20 patients and between 1 and 3 months in 4; 7 patients received immediate postoperative irradiation preceding high-dose alkylator-based chemotherapy. At a median follow-up of 48 months, the cumulative incidence of local treatment failure was 37.5% {+-} 9%; progression-free survival was 33.2% {+-} 10%; and OS was 53.5% {+-} 10%. Children receiving delayed RT ({>=}1 month postoperatively) were more likely to experience local failure (hazard ratio [HR] 1.23, p = 0.007); the development of distant metastases before RT increased the risk of progression (HR 3.49, p = 0.006); and any evidence of disease progressionbefore RT decreased OS (HR 20.78, p = 0.004). Disease progression occurred in 52% (11/21) of children with initially localized tumors who underwent gross total resection, and the progression rate increased proportionally with increasing delay from surgery to RT. Conclusions: Delayed RT is associated with a higher rate of local and metastatic disease progression in children with AT/RT. Current treatment regimens for pediatric patients with AT/RT are distinctly age stratified; novel protocols investigating RT volumes and sequencing are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Intensity UV Exposure for the Rapid Screening of Silicon Photovoltaic Architectures

Advanced Si photovoltaic architectures incorporate different materials and processing pathways that influence degradation modes. Ultraviolet-induced degradation (UVID) is an understudied degradation mode for advanced cell architectures and is of increasing concern to industry due to growing adoption of UV-transparent encapsulation and bifacial technologies. In order to adopt new and evolving technologies confidently, novel component materials and processing techniques must be evaluated and designed for long-term stability, in addition to the conventional design focus on efficiency. In this work, a study protocol framework is presented for the rapid screening of unencapsulated devices against UVID. Unencapsulated passivated emitter rear contact (PERC) and tunnel oxide passivated contact (TOPCon) devices were aged under different UV irradiance intensities and measured via conventional nondestructive electrical characterization methods to assess performance degradation. Based on the results, protocol efficacy and recommendations for further study are discussed. As a result, this work is part of a broader effort to develop rapid screening processes that cut across architectures and exposure conditions to aid module manufacturers in vetting new materials choices for long-term stability.

Accelerated exposure↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials: Preprint

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International ElectrotechnicalCommission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sandsubstrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). Thetest procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

SU-E-T-661: Quantitative MRI Assessment of a Novel Direction-Modulated Brachytherapy Tandem Applicator for Cervical Cancer

Purpose: To quantitatively evaluate the MR image quality of a novel direction modulated brachytherapy (DMBT) tandem applicator for cervical cancer, using the clinical MRI scanning protocol for image guided brachytherapy. Methods: The tungsten alloy-based applicator was placed in a water phantom and clinical imaging protocol was performed. Axial images were acquired using 2D turbo-spin echo (TSE) T2-weighted sequence on a 1.5T GE 450w MR scanner and an 8-channel body coil. As multi-channel receiver coil was used, inhomogeneities in the B1 receive field must be considered before performing the quantification process. Therefore the applicator was removed from the phantom and the whole imaging session was performed again for the water phantom with the same parameters. Images from the two scans were then subtracted, resulting in a difference image that only shows the applicator with its surrounding magnetic susceptibility dipole artifact. Line profiles were drawn and plotted on the difference image at various angles and locations along the tandem. Full width at half maximum (FWHM) was measured at all the line profiles to quantify the extent of the artifact. Additionally, the extent of the artifact along the diameter of the tandem was measured at various angles and locations. Results: After removing the background inhomogeneities of the receiver coil, FWHM of the tandem measured 5.75 ± 0.35 mm (the physical tandem diameter is 5.4 mm). The average extent of the artifacts along the diameter of the tandem measured is 2.14 ± 0.56 mm. In contrast to CT imaging of the same applicator (not shown here), the tandem can be easily identified without additional correction algorithms. Conclusion: This work demonstrated that the novel DMBT tandem applicator has minimal susceptibility artifact in T2-weighted images employed in clinical practice for MRI-guided brachytherapy of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm may very well be warranted.

60 APPLIED LIFE SCIENCES↗

BEopt™ (Building Energy Optimization Tool) [SWR-05-41]

The BEopt™ (Building Energy Optimization Tool) software provides capabilities to evaluate residential building designs and identify cost-optimal efficiency packages at various levels of whole-house energy savings along the path to zero net energy. BEopt can be used to analyze both new construction and existing home retrofits, as well as single-family detached and multi-family buildings, through evaluation of single building designs, parametric sweeps, and cost-based optimizations. BEopt provides detailed simulation-based analysis based on specific house characteristics, such as size, architecture, occupancy, vintage, location, and utility rates. Discrete envelope and equipment options, reflecting realistic construction materials and practices, are evaluated. BEopt uses EnergyPlus, the Department of Energy's flagship simulation engine. Simulation assumptions are based on the Building America Housing Simulation Protocols. The sequential search optimization technique used by BEopt: Finds minimum-cost building designs at different target energy-savings levels, Identifies multiple near-optimal designs along the path, allowing for equivalent solutions based on builder or contractor preference. BEopt has been developed by the National Renewable Energy Laboratory in support of the U. S. Department of Energy Building America program goal to develop market-ready energy solutions for new and existing homes.

Christensen, Craig↗

Concrete mixture characterization. Cementitious barriers partnership

This report summarizes the characterization study performed on two concrete mixtures used for radioactive waste storage. Both mixtures were prepared with approximately 425 kg of binder. The testing protocol mostly focused on determining the transport properties of the mixtures; volume of permeable voids (porosity), diffusion coefficients, and water permeability were evaluated. Tests were performed after different curing durations. In order to obtain data on the statistical distribution of transport properties, the measurements after 2 years of curing were performed on 10+ samples. Overall, both mixtures exhibited very low tortuosities and permeabilities, a direct consequence of their low water-to-binder ratio and the use of supplementary cementitious materials. The data generated on 2-year old samples showed that porosity, tortuosity and permeability follow a normal distribution. Chloride ponding tests were also performed on test samples. They showed limited chloride ingress, in line with measured transport properties. These test results also showed that both materials react differently with chloride, a consequence of the differences in the binder chemical compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report for Industrial Base Cybersecurity Initiative (IBCI) Project (FY2019)

Information security issues impact all manufacturing sectors and are particularly troublesome when designs for advanced weapons systems are lost via attacks that propagate through the relatively unprotected lower tiers of the nation's supply chains. The US Manufacturing Industrial Base (MIB) consists of suppliers and distributors that range in size from large prime contractors with extensive cybersecurity resources to small shops with little or no in-house information technology capabilities. The acquisition and maintenance of the technologies, systems, and financial resources needed to assure secure collaborations can be an overwhelming challenge for many manufacturers yet the cost of poor cybersecurity practices can lead to the compromise of national security information worth hundreds of millions of dollars. The Department of Defense Manufacturing Industrial Base Policy organization and the Department of Energy, Energy Efficiency and Renewable Energy Advanced Manufacturing Office have chartered the Los Alamos National Laboratory (LANL) and the Oak Ridge Y-12 National Security Complex (Y-12) to design, develop, and demonstrate a Manufacturing Threat Evaluation Wargaming System (MTEWS). The MTEWS concept is based on the use of a virtual model of the computer networks and cybersecurity protocols used across the MIB that will be continuously updated to reflect the dynamic threat environment. The MTEWS cyber-physical test range will demonstrate a prototype wargaming system that analyzes the impact of new and existing cybersecurity threats while also providing the information needed to sustain the integrity of the MIB supply chains. A long-term goal is the establishment of an enduring national manufacturing operations center that proactively responds to the continuously changing attacks that threaten the MIB and US national security. LANL and Y-12 have formed an Industrial Base Cybersecurity Initiative Team (IBCI), consisting of partners from the public, private and academic sectors, that is developing the MTEWS. To date, most of the project tasks have been centered on the technologies required to create a representative model of the MIB because this is a foundational element for the entire project. Modeling activities at the University of North Carolina at Charlotte (UNC Charlotte) have demonstrated a VMware-based prototype system that can accommodate a network model with up to 350 nodes and includes features such as the option to incorporate network scanning information when building the model and the ability to down select the elements of duplicative networks to a statistically significant subset that avoids redundantly duplicating network configurations. Broad Ordering Agreements have been established with UNC Charlotte and the University of West Florida (UWF) that support a variety of cybersecurity for manufacturing tasks and wide-spread endorsement has been received from government, industry and academia sectors concerning the IBCI goals and technical direction.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Prioritizing Off-Gas Metrics: A Guide for Comparable Off-Gas Capture Testing

The Material Recovery and Waste Form Development (MRWFD) off-gas team had a workshop, hosted by Idaho National Laboratory (INL), to align goals and expectations for off-gas research. The workshop included team members from four national laboratories. The workshop focused on defining distinct R&D phases with specific metrics, outlining standard test and measurement protocols for Iodine and Krypton/Xenon sorbents, brainstorming approaches to future disruptive technologies, and recognizing parameters with more inherent risk, requiring more rigorous evaluation. This report will serve as a guide for future off-gas work. Its purpose is to foster efficient collaboration across diverse research facilities and invite direct comparison of materials and results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Federal Facility Agreement and Consent Order: Nevada National Security Site Use Restriction Management Plan with ROTC 1

This Use Restriction Management Plan (URMP) provides the information needed to create, modify, and manage use restrictions (URs) for sites on the Nevada National Security Site (NNSS), and sites accessed through the NNSS main gate, that were closed using the corrective action alternative (CAA) of closure in place under the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). (Note: This pertains to those FFACO sites not managed by the U.S. Department of Energy [DOE], Legacy Management.) The closure in place alternative is used for sites closed with residual contamination at levels requiring corrective action as determined using the FFACO process. The URs contain and control all requirements for long-term monitoring. This URMP also serves as the single repository of the URs implemented under the FFACO that identify use restricted areas and contain the current requirements for inspections, maintenance, and monitoring of the UR. The requirements in these URs replace all requirements listed in previous documentation. This consolidates post-closure monitoring requirements into a single source that ensures completeness and consistency of UR requirements and information. Standardized UR forms were developed to clearly document post-closure requirements that are consistent with current protocols and to ensure consistent information is contained in the URs. Standard notification, summary, and site controls statements were developed for all URs with provisions to insert site-specific options in the text. Current protocols for Industrial Sites and Soils URs are defined in this document and in the Soils Risk-Based Corrective Action (RBCA) Evaluation Process (DOE/EMNV, 2018). The standardized UR forms that have been approved to date are listed in Appendix A. Additional UR forms will be added once the review and approval process has been completed.

54 ENVIRONMENTAL SCIENCES↗

Medical experiment M-171 - Results from the second manned Skylab mission

Preflight, inflight, and postflight exercise response tests were conducted on the astronauts of the second Skylab mission as part of an evaluation of physiological adaptation to long-term weightlessness. The flight phase of this mission was 59 days in duration. An exercise protocol was designed around a bicycle ergometer which was used to apply work loads approximating 25, 50, and 75% of each crewman's measured maximum aerobic capacity. Respiratory gas exchange, heart rate, and blood pressure were measured during all tests; cardiac output was measured at selected times during preflight and postflight tests. Data obtained both at rest and during exercise in flight showed no consistent changes which would indicate a degraded physical work capacity. In fact, heart rate during exercise actually decreased for all crewmen in flight. This response indicated improved physical fitness in flight relative to preflight. The postflight period of readaptation to 1 G was characterized by a marked tachycardia, during which time stroke volume was decreased. This response returned to normal within 5-day postflight.

Rummel, J. A.↗