Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Interferometry

The following recommended programs are reviewed: (1) infrared and optical interferometry (a ground-based and space programs); (2) compensation for the atmosphere with adaptive optics (a program for development and implementation of adaptive optics); and (3) gravitational waves (high frequency gravitational wave sources (LIGO), low frequency gravitational wave sources (LAGOS), a gravitational wave observatory program, laser gravitational wave observatory in space, and technology development during the 1990's). Prospects for international collaboration and related issues are also discussed.

Ridgway, Stephen↗

SIM Configuration Evolution

The Space Interferometry Mission (SIM) is a space-based 10 m baseline Michelson interferometer. Planned for launch in 2005 aboard a Delta III launch vehicle, or equivalent, its primary objective is to measure the positions of stars and other celestial objects with an unprecedented accuracy of 4 micro arc seconds. With such an instrument, tremendous advancement can be expected in our understanding of stellar and galactic dynamics. Using triangulation from opposite sides of the orbit around the sun (i.e. by using parallax) one can measure the distance to any observable object in our galaxy. By directly measuring the orbital wobble of nearby stars, the mass and orbit of planets can be determined over a wide range of parameters. The distribution of velocity within nearby galaxies will be measurable. Observations of these and other objects will improve the calibration of distance estimators by more than an order of magnitude. This will permit a much better determination of the Hubble Constant as well as improving our overall understanding of the evolution of the universe. SIM has undergone several transformations, especially over the past year and a half since the start of Phase A. During this phase of a project, it is desirable to perform system-level trade studies, so the substantial evolution of the design that has occurred is quite appropriate. Part of the trade-off process has addressed two major underlying architectures: SIM Classic; and Son of SIM. The difference between these two architectures is related to the overall arrangement of the optical elements and the associated metrology system. Several different configurations have been developed for each architecture. Each configuration is the result of design choices that are influenced by many competing considerations. Some of the more important aspects will be discussed. The Space Interferometry Mission has some extremely challenging goals: millikelvin thermal stability, nanometer stabilization of optics, picometer measurement of wavefront, and others. In order to meet these goals, a significant amount of technological development is required. Although there has been a program operating for about a decade developing technologies specifically to address the challenges of space-based interferometry, there still remains a tremendous effort to achieve the incredible accuracy required of SIM. The projected viability of some of these areas has influenced design choices during the evolution of the many configurations that have been developed. For instance, the perceived complexity of the IR laser metrology system used to measure and control the positions of key optical elements was the strongest discriminator between the two architectures, and led to a decision to select SOS rather than Classic in early 1998. More recently, an appreciation of the sensitivity to beam-walk within the SOS architecture is forcing a reconsideration of that decision. At the time of submission of this abstract, there is some hope that a full-aperture metrology system may alleviate this issue. In addition to describing the current configuration of SIM, the influence of a few selected areas on the evolution of the configuration will be discussed.

Aaron, Kim M.↗

Single-shot spatiotemporal measurements of ultrashort THz waveforms using temporal electric-field cross correlation

A new single-shot technique based on linear spectral interferometry between a temporally short reader pulse and a temporally long probe pulse is demonstrated for measuring the spatiotemporal phase and amplitude of an optical probe for use as an ultrafast diagnostic. The probe spatiotemporal field information is recovered, with a resolution set by the duration of the reader pulse, by applying a single Fourier transform operation to the interferogram image, without need of any reference data. The technique was used in conjunction with electro-optic sampling to measure waveforms of coherent, ultrashort THz pulses emitted by electron bunches from a laser-plasma accelerator with sub-50fs resolution. The presence of strong spatiotemporal coupling in the THz waveforms and of complex temporal electron-bunch structure was determined.

43 PARTICLE ACCELERATORS↗

Wire, hybrid, and laser-cut X-pinches as Talbot–Lau backlighters for electron density diagnostics

Talbot–Lau x-ray deflectometry (TXD) enables refraction-based imaging for high-energy-density physics experiments, and thus, it has been studied and developed with the goal of diagnosing plasmas relevant to inertial confinement and magnetic liner inertial fusion. X-pinches, known for reliably generating fast (~1 ns), small (~1 µm) x-ray sources, were driven on the compact current driver generator for ablation structure and implosion studies (~200 kA, 150 ns) as a potential backlighter source for TXD. Considering that different X-pinch configurations have characteristic advantages and drawbacks as x-ray generating loads, three distinct copper X-pinch configurations were studied: the wire X-pinch, the hybrid X-pinch, and the laser-cut X-pinch. Furthermore, the Cu K-shell emission from each configuration was characterized and analyzed regarding the specific backlighter requirements for an 8 keV TXD system: spatial and temporal resolution, number of sources, time of emission, spectrum, and reproducibility. Recommendations for future experimental improvements and applications are presented. The electron density of static objects was retrieved from Moiré images obtained through TXD. This allowed to calculate the mass density of static samples within 4% of the expected value for laser-cut X-pinches, which were found to be the optimal X-pinch configuration for TXD due to their high reproducibility, small source size (≤5 µm), short duration (~1 ns), and up to 106 W peak power near 8 keV photon energy. Plasma loads were imaged through TXD for the first-time using laser-cut X-pinch backlighting. Experimental images were compared with simulations from the x-ray wave-front propagation code, demonstrating that TXD can be a powerful x-ray refraction-based diagnostic for dense Z-pinch loads. Future plans for Talbot–Lau interferometry diagnostics in the pulsed-power environment are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Applications of laser speckles in a holographic nondestructive test system

The grainy or speckle phenomenon of laser light is caused by two inherent characteristics of the laser - the coherence and monochromaticity of the radiation. Recent development have shown that this phenomenon can be used to measure minute surface displacements, surface strains, or vibrations of a body. The present paper deals with two techniques employing the speckle effect. One is called speckle beam holographic interferometry, and the other speckle photographic interferometry. A major advantage of the first technique is the elimination of the stringent vibration isolation requirement in existing holographic nondestructive test systems. The advantage of the second technique is that the resulting photographic data are sensitive only to the in-plane components of the surface variations. The basic principles and practical limitations of these techniques are discussed.

Liu, H.-K.↗

Quantum noise limits to matter-wave interferometry

We derive the quantum limits for an atomic interferometer in which the atoms obey either Bose-Einstein or Fermi-Dirac statistics. It is found that the limiting quantum noise is due to the uncertainty associated with the particle sorting between the two branches of the interferometer. As an example, the quantum-limited sensitivity of a matter-wave gyroscope is calculated and compared with that of laser gyroscopes.

Scully, Marlan O.↗

Baseline Monitoring for Astrometry in Interferometry

One of the science goals of NASA's Navigator program is ground-based narrow-angle astrometry for extra-solar planet detection, which could be done as part of the proposed Outrigger Telescopes Project. The narrow-angle measurement process, which would use the outrigger telescopes, starts with the determination of the conventional interferometer astrometric baseline, determined from wide-angle astrometry of Hipparcos stars. A baseline monitor system would be employed at each outrigger telescope. This system monitors the pivot point of each telescope - the end point of the astrometric baseline - to measure telescope imperfections that would cause the baseline to vary with telescope rotation. The baseline monitor includes azimuth and elevation cameras that monitor runout along the azimuth and elevation axes of the telescopes. In conjunction with the baseline monitor system, a pivot monitor camera in the dual-star module is used to register the laser metrology corner-cube reflector to the telescope pivot, tying the narrow-angle baseline, which applies to the narrow-angle astrometric measurement, to the wide-angle baseline. In this paper we present the proposed designs for the baseline monitor and pivot-point camera.

pivot point↗

High data rate atom interferometric device

A light-pulse atomic interferometry (LPAI) apparatus is provided. The LPAI apparatus comprises a vessel, two sets of magnetic coils configured to magnetically confine an atomic vapor in two respective magneto-optical traps (MOTs) within the vessel when activated, and an optical system configured to irradiate the atomic vapor within the vessel with laser radiation that, when suitably tuned, can launch atoms previously confined in each of the MOTs toward the other MOT. In embodiments, the magnetic coils are configured to produce a magnetic field that is non-zero at the midpoint between the traps. In embodiments, the time-of-flight of the launched atoms from one MOT to the other is 12 ms or less. In embodiments, the MOTs are situated approximately 36 mm apart. In embodiments, the apparatus is configured to activate the magnetic coils according to a particular temporal magnetic field gradient profile.

47 OTHER INSTRUMENTATION↗

Holography on the NASA Space Shuttle

The SL-3 flight on the Space Shuttle will carry a 25 mW He-Ne laser holographic recorder for recording the solution growth of triglycine sulfate (TGS) crystals under low-zero gravity conditions. Three hundred holograms (two orthogonal views) will be taken (on SO-253 film) of each growth experiment. Processing and analysis (i.e., reconstructed imagery, holographic schlieren, reverse reference beam microscopy, and stored beam interferometry) of the holographic records will be done at NASA/MSFC. Other uses of the recorder on the Shuttle have been proposed.

Wuerker, R. F.↗

X-ray Moiré deflectometry using synthetic reference images

Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, the method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A study of the relationship between lithium ion transport and structure and dynamic behavior in polyethylene oxide-melt/LiClO 4 battery electrolytes.

An experimental study of the canonical SPE (“solid” polymer electrolyte) for rechargeable “rocking chair” lithium/polymer batteries, viz. LiClO4 dissolved in molten poly(ethylene oxide) (PEO), was carried out under DOE grant FG02-04ER15573. In this study, an improved understanding was obtained of the relationship between lithium ion transport and polymer behavior in these SPEs. Among other applications, these sturdy temperature-tolerant and powerful light-weight batteries would be used in electric and electric-hybrid vehicles to reduce greenhouse gas emissions, to store unused electrical energy for peak demand loads and as compact, light-weight energy sources for aircraft and spacecraft. During the period of the grant, the American/Canadian partnership company “Avestor” fabricated and successfully demonstrated a telecommunications application of shoe-box sized batteries and representatives from Avestor visited our research lab at UNLV. They found our results interesting and relevant to their work and invited us to visit Avestor and present a talk about our efforts at UNLV. Unfortunately Avestor (who was scheduled to build a battery production facility in Apex, Nevada just North of Las Vegas) folded before the visit could be made. In the grant work, two well characterized PEO samples having molar masses distinctly below and distinctly above the melt entanglement molar mass were used and three laser light scattering techniques employed as the principal noninvasive methods of investigating liquid poly(ethylene oxide) (PEO)/LiClO4 SPEs. These investigations considered the effects of temperature, dissolved salt concentration and scattering wavevector on SPE behavior. Classical or “static” light scattering and the dynamic light scattering techniques of photon correlation spectroscopy (PCS) and Fabry-Perot interferometry (FPI) were used to study SPE static, low frequency and high frequency dynamic behaviors, respectively. Static measurements provided information about system structure while low frequency results provided information about slower (0.1-10s) more global behavior and high frequency results provided information about faster (~10-11s) more local behavior. In addition, viscometry, rheometry and thermal analysis provided vital complementary results. It was found that liquid PEO/lithium salt solutions for both PEO molar masses are random transient physical networks with measureable network and intra-network relaxation times using PCS and FPI. Thus novel and informative results addressing both large scale and small scale behavior were obtained. For example, the high sensitivity of liquid PEO electrolytes to the presence of presumably undesirable trace amounts of residual water and/or methanol was clearly evident in PCS measurements. In “unentangled” melts the activation energies for diffusive relaxation in liquid PEO/lithium salt electrolytes measured using PCS and the activation energies for viscous flow in these systems determined by viscometry were identical while thermal analyses detected no phase transitions for these systems. These results reinforced an earlier assumption that the liquid PEO/LiClO4 system is a liquid polymer “bimorph” (to our knowledge the first of its kind to be reported) with the network comprising one form of the polymer while the second form corresponds to that of a viscous damping liquid. At a given temperature, FPI characteristic relaxation times for local, between-chain motions were consistent with PCS results so that increases with increasing salt concentration were accompanied by increases in the elastic modulus and corresponding increases in system stiffness. Note that corresponding decreases in polymer segmental mobility are accompanied by reduced ion diffusivity. For entangled melts, PCS network relaxations were again observed and these systems were also considered to be bimorphs even though diffusion activation energies were distinctly larger than viscous flow activation energies - a difference attributed to the effects of entanglement. Moreover, SLS measurements revealed entangled melts to be “percolation gels” with a measured fractal dimension of about 2 and static correlation lengths that increased gradually from about 500 nm to about 700 nm with increasing salt concentration. Meanwhile, rheological measurements found these polymer/salt melts to behave simply as liquids. FPI measurements have not yet been made on these entangled PEO melts.

25 ENERGY STORAGE↗

NASA Tech Briefs, April 2010

Topics covered include: Active and Passive Hybrid Sensor; Quick-Response Thermal Actuator for Use as a Heat Switch; System for Hydrogen Sensing; Method for Detecting Perlite Compaction in Large Cryogenic Tanks; Using Thin-Film Thermometers as Heaters in Thermal Control Applications; Directional Spherical Cherenkov Detector; AlGaN Ultraviolet Detectors for Dual-Band UV Detection; K-Band Traveling-Wave Tube Amplifier; Simplified Load-Following Control for a Fuel Cell System; Modified Phase-meter for a Heterodyne Laser Interferometer; Loosely Coupled GPS-Aided Inertial Navigation System for Range Safety; Sideband-Separating, Millimeter-Wave Heterodyne Receiver; Coaxial Propellant Injectors With Faceplate Annulus Control; Adaptable Diffraction Gratings With Wavefront Transformation; Optimizing a Laser Process for Making Carbon Nanotubes; Thermogravimetric Analysis of Single-Wall Carbon Nanotubes; Robotic Arm Comprising Two Bending Segments; Magnetostrictive Brake; Low-Friction, Low-Profile, High-Moment Two-Axis Joint; Foil Gas Thrust Bearings for High-Speed Turbomachinery; Miniature Multi-Axis Mechanism for Hand Controllers; Digitally Enhanced Heterodyne Interferometry; Focusing Light Beams To Improve Atomic-Vapor Optical Buffers; Landmark Detection in Orbital Images Using Salience Histograms; Efficient Bit-to-Symbol Likelihood Mappings; Capacity Maximizing Constellations; Natural-Language Parser for PBEM; Policy Process Editor for P(sup 3)BM Software; A Quality System Database; Trajectory Optimization: OTIS 4; and Computer Software Configuration Item-Specific Flight Software Image Transfer Script Generator.

Source record↗

Mission Analysis for Laser Interferometer Space Antenna (LISA)

The interplanetary orbits of three pairs of spaceprobes carrying laser interferometer antennae are designed such that their miutual distances, i.e., the lengths of the interferometer arms remain nearly constant. The pairs move relative to each other in an equilateral triangle.

LISA interferometry interferometer↗

Entanglement-enhanced matter-wave interferometry in a high-finesse cavity

An ensemble of atoms can operate as a quantum sensor by placing atoms in a superposition of two different states. Upon measurement of the sensor, each atom is individually projected into one of the two states. Creating quantum correlations between the atoms, that is entangling them, could lead to resolutions surpassing the standard quantum limit set by projections of individual atoms. Large amounts of entanglement involving the internal degrees of freedom of laser-cooled atomic ensembles have been generated in collective cavity quantum-electrodynamics systems, in which many atoms simultaneously interact with a single optical cavity mode. Here we report a matter-wave interferometer in a cavity quantum-electrodynamics system of 700 atoms that are entangled in their external degrees of freedom. In our system, each individual atom falls freely under gravity and simultaneously traverses two paths through space while entangled with the other atoms. In this work, we demonstrate both quantum non-demolition measurements and cavity-mediated spin interactions for generating squeezed momentum states with directly observed sensitivity $3.4^{+1.1}_{–0.9}$dB and $2.5^{+0.6}_{–0.6}$dB below the standard quantum limit, respectively. We successfully inject an entangled state into a Mach–Zehnder light-pulse interferometer with directly observed sensitivity $1.7^{+0.5}_{–0.5}$dB below the standard quantum limit. The combination of particle delocalization and entanglement in our approach may influence developments of enhanced inertial sensors, searches for new physics, particles and fields, future advanced gravitational wave detectors and accessing beyond mean-field quantum many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

TMS XTRRA experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory [1,2] provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

36 MATERIALS SCIENCE↗