Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Lunar surface - Identification of the dark mantling material in the Apollo 17 soil samples

Evidence indicates that Apollo 17 sample 74001, a soil consisting of very dark spheres, is composed almost entirely of the dark mantling material that covers a large region of the southeastern boundary of Mare Serenitatis. Other Apollo 17 samples contain only a component of this material. The underlying basalt in the Taurus-Littrow valley appears to be an extension of material forming the low-albedo ring around part of Mare Serenitatis and much of the surface of Mare Tranquillitatis. The surface of this basalt region is spectrally distinct from areas with dark mantling material. These results are derived from telescopic and laboratory measurements of the optical properties of lunar soil. Digital vidicon color images are used to map the extent of these material units in the Taurus-Littrow region.

Pieters, C.↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗

An Analysis of Nondestructive Evaluation Techniques for Polymer Matrix Composite Sandwich Materials

Structural sandwich materials composed of triaxially braided polymer matrix composite material face sheets sandwiching a foam core are being utilized for applications including aerospace components and recreational equipment. Since full scale components are being made from these sandwich materials, it is necessary to develop proper inspection practices for their manufacture and in-field use. Specifically, nondestructive evaluation (NDE) techniques need to be investigated for analysis of components made from these materials. Hockey blades made from sandwich materials and a flat sandwich sample were examined with multiple NDE techniques including thermographic, radiographic, and shearographic methods to investigate damage induced in the blades and flat panel components. Hockey blades used during actual play and a flat polymer matrix composite sandwich sample with damage inserted into the foam core were investigated with each technique. NDE images from the samples were presented and discussed. Structural elements within each blade were observed with radiographic imaging. Damaged regions and some structural elements of the hockey blades were identified with thermographic imaging. Structural elements, damaged regions, and other material variations were detected in the hockey blades with shearography. Each technique s advantages and disadvantages were considered in making recommendations for inspection of components made from these types of materials.

Cosgriff, Laura M.↗

Super‐Resolution Lifetime Imaging of Single Molecules Near Gold Bowtie Nanoparticles

Interactions between light and matter serve as the basis of many technologies, but the quality of these devices is inherently limited by the optical properties of their constituents. Plasmonic nanoparticles are a highly versatile and tunable platform for the enhancement of such optical properties. However, the near-field nature of these effects has made thorough study and understanding of these mechanisms difficult. In this work, we introduce a fully confocal technique combining photoswitching super-resolution microscopy with fluorescence lifetime imaging microscopy to study single-molecule decay rate enhancement. We demonstrate that the technique combines a spatial resolution better than 20 nm, and a 16 ps temporal resolution. Simultaneously, an autocorrelation measurement is also performed to confirm that the data indeed originates from single molecules. This work provides insight into the various mechanisms of plasmon-enhanced emission, and allows the study of the correlation between emission intensity and lifetime enhancement. This complicated relationship is shown to be dependent upon the relative influence of various radiative and nonradiative decay pathways. Here, we provide a platform for further study of emission mislocalization, the position-dependent prominence of different decay pathways, and the direct super-resolved measurement of the local density of states.

36 MATERIALS SCIENCE↗

Differential programming enabled functional imaging with Lorentz transmission electron microscopy

Abstract Lorentz transmission electron microscopy is an advanced characterization technique that enables the simultaneous imaging of both the microstructure and functional properties of materials. Information such as magnetization and electric potentials is carried by the phase of the electron wave, and is lost during image acquisition. Various methods have been proposed to retrieve the phase of the electron wavefunction using intensities of the acquired images, most of which work only in the small defocus limit. Imaging at strong defoci not only carries more quantitative phase information, but is essential to the study of weak magnetic and electrostatic fields at the nanoscale. In this work we develop a method based on differentiable programming to solve the inverse problem of phase retrieval. We show that our method maintains a high spatial resolution and robustness against noise even at the upper defocus limit of the microscope. More importantly, our proposed method can go beyond recovering just the phase information. We demonstrate this by retrieving the electron-optical parameters of the contrast transfer function alongside the electron exit wavefunction.

97 MATHEMATICS AND COMPUTING↗

Optical reflectance imaging reveals interlayer coupling in mechanically stacked MoS 2 and WS 2 bilayers

Optical reflectance imaging is a popular technique for characterizing 2D materials, thanks to its simplicity and speed of data acquisition. The use of this method for studying interlayer phenomena in stacked 2D layers has, however, remained limited. Here we demonstrate that optical imaging can reveal the nature of interlayer coupling in stacked MoS 2 and WS 2 bilayers through their observed reflectance contrast versus the substrate. Successful determination of interlayer coupling requires co-optimization of the illumination wavelength and the thickness of an underlying SiO 2 film. Our observations are supported by multilayer optical calculations together with an analysis of the effect of any interlayer gap. This approach promises quick characterization of constructed 2D material systems.

Nguyen, Vu↗

Understanding important features of deep learning models for segmentation of high-resolution transmission electron microscopy images

Cutting edge deep learning techniques allow for image segmentation with great speed and accuracy. However, application to problems in materials science is often difficult since these complex models may have difficultly learning meaningful image features that would enable extension to new datasets. In situ electron microscopy provides a clear platform for utilizing automated image analysis. In this work, we consider the case of studying coarsening dynamics in supported nanoparticles, which is important for understanding, for example, the degradation of industrial catalysts. By systematically studying dataset preparation, neural network architecture, and accuracy evaluation, we describe important considerations in applying deep learning to physical applications, where generalizable and convincing models are required. With a focus on unique challenges that arise in high-resolution images, we propose methods for optimizing performance of image segmentation using convolutional neural networks, critically examining the application of complex deep learning models in favor of motivating intentional process design.

36 MATERIALS SCIENCE↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Investigating the dielectric properties of barium titanate nanocomposites using transmission electron microscopy image processing

Abstract Barium titanate (BTO) is a ferroelectric perovskite material used in energy storage applications because of its high dielectric constant. A previous study showed that the dielectric constant for BTO nanoparticles drastically increases to over 15,000 at a particle size of 70 nm. This result is highly contested, but its implications to energy storage motivated our investigation into the dielectric constants of BTO nanoparticles that are incorporated into a polymer matrix. We developed a novel method of using image processing techniques on transmission electron microscope images of BTO-polymer nanocomposites. Data on the positions, shapes, sizes, and orientations of BTO nanoparticles were used to build more realistic computational models that simulate the dielectric behavior of the nanocomposites. Here, we investigate the relationship between regions of enhanced electric field and the composite dielectric constant.

36 MATERIALS SCIENCE↗

Experimental Study of the Fundamental Properties of Warm Dense Mixtures

The aim of the proposed research was to provide a multi-scale study of the properties of warm dense hydrocarbons, by studying the thermodynamic properties through the equation of state and the microscopic properties by x-ray scattering. Understanding the fundamental properties of warm dense mixtures is an intellectual challenge due to the complexity of the system. Unlike liquids or gases, where constituent particle interactions occur through collisions or bonding between valence electrons, in these strongly coupled systems the atoms will be partially ionized and compressed so tightly together that interactions between the inner core electrons can play a role in the systems chemistry. Advances in computational capabilities and development of new theoretical models have been used to predict the properties of mixtures but there is currently no experimental data of the fundamental interaction between the particles in mixtures to test these predictions against. The proposed research was to experimentally investigate the interaction of the different species in hydrocarbons by measuring the compressibility of substances with different carbon and hydrogen ratios and the complexity of the microscopic interactions through elastic and inelastic x-ray scattering. To study the bulk properties of warm dense hydrocarbons we established the Warm Dense Matter Research Laboratory (WDMRL) in the Institute for Shock Physics at Washington State University. The goal was for experiments in the WDMRL to determine shock loading conditions of interest in the hydrocarbon mixtures. We planned on using Hugoniot EOS measurements and a range of carbon and hydrogen concentrations to determine conditions when the EOS of the mixture varied significantly from that of the classical mixing model. Even though shock transit measurements through aluminum foils suggested pressures upto 400GPa, the experiments in the WDMRL were unsuccessful in getting usable shockwave compression data above 100GPa in polystyrene which was below the pressure of interest for hydrocarbon mixtures (>200GPa). To complete the project, we tested a technique using x-ray phase contrast imaging to map the location of tracer layers in a test sample of polycarbonate to record the material motion in dynamically compressed samples. A technique that will be useful for future warm dense matter experiments. These experiments used <200nm gold layers in polycarbonate samples to measure the material velocity and shock speed using x-ray phase contrast imaging. These results were compared to continuum surface measurements performed at ISP and show that the tracer layer technique can measure hydrodynamic properties accurately in dynamically compressed materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Transport and Imaging of Novel Phases of Moiré Quantum Matter

Moiré materials open an entirely new platform for exploring the interplay between band structure, interactions, symmetry and topology. Strong effects of interaction can result from antiferromagnetic correlations as is commonly found in high temperature superconductors. Alternatively, the effects of interactions can be strengthened by reducing the role of kinetic energy as is commonly done in quantum Hall systems. Interestingly, moiré materials are a new class of materials where both types of effects can be present simultaneously, even at zero magnetic field, leading to a plethora of new correlated topological phases. Here we plan to harness the expertise of our groups in synthesis, fabrication, and novel measurement techniques to unravel and elucidate some of the mysteries of moiré materials. Our goal in this proposal has been to deepen our understanding of correlated phases in moiré materials using a variety of experimental tool developed in the PI’s labs. We used thermodynamic probes based on local and global electrostatic sensing to provide direct information on compressibility, entropy, magnetization and topology. Revealing the fundamental principles of correlated topological matter may pave the way towards a new class of materials with superior electronic characteristics with possible application in quantum science, engineering and energy harvesting platforms.

36 MATERIALS SCIENCE↗

Scaling up the Single Transducer Thickness-Independent Ultrasonic Imaging Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.

Roth, Don J.↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Assessment of Dynamic Fracture in Ultra-High Performance Concrete Using Synchrotron X-ray Source

Ultra-high-performance concretes (UHPCs) retain higher ultimate (compressive) strengths and greater durability relative to traditional concrete materials. As a result, they are enabling construction materials for blast resistant structures, where a higher capacity for energy absorption is required. In past investigations, the strength of UHPCs was shown to retain a dependency on strain rate. Still, the failure mechanisms which govern this rate dependency have yet to be completely elucidated. In the current study, the dynamic fracture behavior of Cor-tuf UHPC was assessed, in-situ, using a Synchrotron X-ray source in phase contrast imaging (PCI) mode. Prior to testing, the material’s morphology was characterized using X-ray computed tomography (CT) and scanning electron microscopy (SEM). A polychromatic pulsed X-ray source, high-speed camera and Kolsky bar apparatus were used in tandem, to observe the transient failure modes. A pin was placed at the end of the incident bar to control the location of damage initiation, and tests were performed at a constant velocity of ~6 m/s. These test conditions were observed to yield cracks with median and/or cone like geometries. Despite the variation in the crack paths, a significant difference in peak load was not observed. The failure mode was also observed to depend on the microstructure of the concrete samples.

Kolsky bar↗

Spectral Classification of Similar Materials using the Tetracorder Algorithm: The Calcite-Epidote-Chlorite Problem

Recent work on automated spectral classification algorithms has sought to distinguish ever-more similar materials. From modest beginnings separating shade, soil, rock and vegetation to ambitious attempts to discriminate mineral types and specific plant species, the trend seems to be toward using increasingly subtle spectral differences to perform the classification. Rule-based expert systems exploiting the underlying physics of spectroscopy such as the US Geological Society Tetracorder system are now taking advantage of the high spectral resolution and dimensionality of current imaging spectrometer designs to discriminate spectrally similar materials. The current paper details recent efforts to discriminate three minerals having absorptions centered at the same wavelength, with encouraging results.

Dalton, J. Brad↗