Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Dynamic testing of a two-dimensional box truss beam

Testing to determine the effects of joint freeplay and pretensioning of diagonal members on the dynamic characteristics of a two-dimensional box truss beam was conducted. The test article was ten bays of planar truss suspended by long wires at each joint. Each bay measured 2 meters per side. Pins of varying size were used to simulate various joint freeplay conditions. Single-point random excitation was the primary method of test. The rational fraction polynomial method was used to extract modal characteristics from test data. A finite element model of the test article was generated from which modal characteristics were predicted. These were compared with those obtained from tests. With the exception of the fundamental mode, correlation of theoretical and experimental results was poor, caused by the resonant coupling of local truss member bending modes with global truss beam modes. This coupling introduced many modes in the frequency range of interest whose frequencies were sensitive to joint boundary conditions. It was concluded that local/global coupling must be avoided in the frequency range where accurate modal characteristics are required.

White, Charles W.↗

Whole Module Offgas Test Report: Space-X Dragon Module

Between 7 April and 11 April 2012 a chemist from the JSC Toxicology Group acquired samples of air in 500 ml evacuated canisters from the sealed Dragon Module at the Space-X facility at KSC. Three samples were taken of facility air (two before the test and one after the test), and a total of 9 samples were taken from the sealed module in triplicate at the following times: 0 hours, 48 hours, and 96 hours. The module contained 470 kg, which was 100% of the mass to be launched. Analytical data contained in the Toxicology Group Report (attached) show that the ambient facility air was clean except for almost 9 milligrams per cubic meter of isopropanol (IPA) in the sample taken at the end of the test. Space-X must ensure that IPA is not introduced into the module before it is sealed for launch. Other minor contaminants in the ambient air included the following: perfluoro(2-methyl)pentane and hexamethylcyclotrisiloxane. The first-acquired samples of each triplicate from the module were not analyzed. Analyses of pairs of samples that were taken during the test show excellent agreement between the pairs and a linear increase in the T-values during the 4 days of the test (figure below). The rate of increase averaged 0.124 T units per day. If the time from last purge of the module on the ground to crew first entry on orbit is 10 days, then the T value at first entry should be less than 1.2 units, which is well below the criterion of 3.0 for consideration of additional protection of the crew from offgas products. The primary contributors were as follows: trimethylsilanol (0.057), fluorotrimethylsilane (0.047), acetaldehyde (0.004), hexamethylcyclopentasiloxane (0.003), and toluene (0.002).

James, John T.↗

An investigation of a sterile access technique for the repair and adjustment of sterile spacecraft

A description is presented of a unique system for the sterilization and sterile repair of spacecraft and the results of a test program designed to assess the biological integrity and engineering reliability of the system. This trailer-mounted system, designated the model assembly sterilizer for testing (MAST), is capable of the dry-heat sterilization of spacecraft and/or components less than 2.3 meters in diameter at temperatures up to 433 K and the steam sterilization of components less than 0.724 meter in diameter. Sterile access to spacecraft is provided by two tunnel suits, called the bioisolator suit systems (BISS), which are contiguous with the walls of the sterilization chambers. The test program was designed primarily to verify the biological and engineering reliability of the MAST system by processing simulated space hardware. Each test cycle simulated the initial sterilization of a spacecraft, sterile repair of a failed component, removal of the spacecraft from the MAST for mating with the bus, and a sterile recycle repair.

Farmer, F. H.↗

Effect of nose shape and tail length on supersonic stability characteristics of a projectile

The effect of nose shape and tail length on the static stability of a fin-stabilized projectile has been investigated in the Langley Unitary Plan with tunnel at angles of attack to about 12 deg for a Mach number range from 1.5 to 2.5. The tests were made at a constant Reynolds number of 6.56 x 1,000,000 per meter. The results of the investigation showed that nose shape had no effect on the static stability. Increasing the tail length resulted in a progressively stabilizing tendency. However, only the 1.5-caliber-tail-length configuration was stable over the test angle-of-attack range at Mach number 1.5. This configuration was marginally stable or unstable at the higher Mach numbers, and the shorter configurations were unstable at all Mach numbers for either part of or the entire test angle-of-attack range.

Sawyer, W. C.↗

Test of LOX compatibility for asphalt and concrete runway materials

A literature survey and a telephone canvass of producers and users of LOX is reported which yielded one report of an accident resulting from a LOX spill on asphalt, one discussion of hazardous conditions, and an unreferenced mention of an incident. Laboratory tests using standard LOX impact apparatus yielded reactions with both old and new alphalt, but none with concrete. In the final test, using a larger sample of asphalt, the reaction caused extensive damage to equipment. Initial field experiments using 2-meter square asphalt slabs covered with LOX, conducted during rainy weather, achieved no reaction with plummets, and limited reaction with a blasting cap as a reaction initiator. In a final plummet-initiated test on a dry slab, a violent reaction, which appeared to have propagated over the entire slab surface, destroyed the plummet fixture and threw fragments as far as 48 meters.

Moyers, C. V.↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Real-world Measurement-based Phase Identification in Power Distribution Feeders with a Novel Reliability Criteria Assessment

This paper is concerned with solving the phase identification problem in a real-world smart grid project; where there is only a few smart meters available on each of the five power distribution feeders in the test site in Riverside, CA. The main idea is to develop and use two reliability criteria that can identify the most reliable components in a broken-down phase identification analysis; thereby significantly improving the accuracy of phase identification. The proposed method consists of three steps. The results from field implementation reveal the accuracy and consistency of the proposed method in practice, in correctly and reliability identifying the phase connectivity.

Phase identification Data-driven method Sliding wi↗

Modeling laser wakefield accelerator experiments with ultrafast particle-in-cell simulations in boosted frames

The development of new laser systems at the 10 Petawatt range will push laser wakefield accelerators to novel regimes, for which theoretical scalings predict the possibility to accelerate electron bunches up to tens of GeVs in meter-scale plasmas. Numerical simulations will play a crucial role in testing, probing, and optimizing the physical parameters and the setup of future experiments. Fully kinetic simulations are computationally very demanding, pushing the limits of today's supercomputers. In this paper, the recent developments in the OSIRIS framework [R. A. Fonseca et al., Lect. Notes Comput. Sci. 2331, 342 (2002)] are described, in particular the boosted frame scheme, which leads to a dramatic change in the computational resources required to model laser wakefield accelerators. Results from one-to-one modeling of the next generation of laser systems are discussed, including the confirmation of electron bunch acceleration to the energy frontier.

43 PARTICLE ACCELERATORS↗

Brayton Solar Power Conversion System

This report contains the results of work performed in on Phase 1 and Phase 2 related to the Brayton Solar Power Conversion System project. The SolarCAT (Solar Compressed Air Turbine) is dish-engine module with compressed air energy storage. It generates 200-kWe peak power, employing a 320 sq. meter dish. Designed for multi-MW arrays, the power plant provides utility load-profile shaping as well as efficient solar power conversion. At the discretion of the utility operator, the gas turbine also operates on a wide range of fuels (bio and fossil) to supplement solar power or provide non-solar operation. A brief description of the principal subassemblies follows: • The “engine” is a compact turbo-alternator operating with only air serving as the working fluid, the lubricant, and the coolant. The turbo-alternator has been designed to be maintenance-free for the 20-year (60,000 hour) life. • The solar receiver is a tubular design incorporating mature heat exchanger design practices. ORNL has been instrumental in evaluating materials for this application. • The tracking solar concentrator (Dish) was developed and installed at Southwest Solar Technologies, by private funding. The unit constructed for Phase 2 has a collection area of approximately 320 sq meters. The critical subassemblies of the system have been fabricated and tested in Phase 2 of this program. Each subsystem was purpose-built for this new power generation system. This included a special turbo-alternator system built with air bearings, a very compact recuperator, a hybrid combustor, and a solar receiver fully integrated for installation on the SST dish. The receiver was tested alone on the dish. The extensive testing of the turbomachinery, dish and receiver conducted on this program has overcome common development issues. Furthermore, the team has worked exceptionally hard to prove the performance and cost basis of the system. Reliable subsystems have been checked-out and are ready to be move into the complete engine-dish module in Phase 3. In parallel, several economically-driven component upgrades have been identified which improve efficiency and lower cost. The project was terminated prior at the end of Phase 2, to installing the special purpose recuperated turbo-alternator on the dish.

14 SOLAR ENERGY↗

Recovery Act - An Interdisciplinary Program for Education and Outreach in Transportation Electrification

1) How the project adds to the education of engineering students in the area of vehicle electrification: This project created and implemented a significant interdisciplinary curriculum in HEV engineering that includes courses focused on the major components (engines, battery cells, e-machines, and power electronics). The new curriculum, rather uniquely, features two new classes and two new labs that emphasize a vehicle level integration of a hybrid electric powertrain that parallels the vehicle development process used by the OEMs - commercial grade software is used to design a hybrid electric vehicle, hardware-in-the-loop testing is performed on each component until the entire powertrain is optimized, the calibration is flashed to a vehicle, ride-and-drives are executed including on board data acquisition. In addition, nine existing courses were modified by adding HEV material to the courses. 2) The educational effectiveness and economic feasibility of the new curriculum: The new courses are offered at both the undergraduate and graduate levels. They are listed across the college in mechanical, chemical, electrical, and materials science and engineering. They are offered both on campus and to distance learning students. Students across the college of engineering and at all degree levels are integrating these courses into their degree programs. Over the three year project the course enrollments on-campus has totaled 1,249. The distance learning enrollments has totaled 315. With such robust enrollments we absolutely expect that these courses will be in the curriculum for the long run. 3) How the project is otherwise of benefit to the public: One outcome of the project is the construction of the Michigan Tech Mobile Lab. Two complete HEV dynamometer test cells, and four work stations are installed in the 16.2 meter Mobile Laboratory and hauled by a class 8 truck. The Mobile Lab is used to teach the university courses. It is also used to deliver short courses to industry, K-12 outreach, and public education. In 2012 the Mobile Lab participated in 22 outreach events, locally, throughout Michigan, and including events in Washington DC, Illinois, and Wisconsin. The Mobile Lab is a hit wherever it goes. In 2013 we will partner with the US Army TARDEC and be featured in their Green Warrior Convoy, a ten city tour starting in Detroit and finishing in Washington DC.

33 ADVANCED PROPULSION SYSTEMS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LA100 Equity Strategies. Chapter 8: Equitable Rooftop Solar Access and Benefits

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on analysis of customer-sited rooftop solar and storage as a means to reduce electricity bills for low- and moderate-income (LMI) households, multifamily building residents, and renters, who traditionally lack access to bill savings from rooftop solar. Specifically, NREL modeled customer-sited solar and storage adoption using the Distributed Generation Market Demand (dGen™)1 model through 2035 and developed scenarios to identify programs or policies that could support equitable access to bill savings from rooftop solar or solar-plus-storage. Scenarios tested include a direct-install program for LMI customers, net metering for LMI customers, and equitable distribution of benefits from installing solar between owners and renters of renter-occupied buildings. Research was guided by input from the community engagement process, and equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

High-temperature strength of refractory-metal wires and consideration for composite applications

Tensile and stress-rupture tests were conducted on wires of W-Hf-C, W-Re-Hf-C, ASTAR 811C (a tantalum alloy), and B-88 (a columbium alloy) at room temperature, 1093 C (2000 F), and 1204 C (2200 F). Metallographic examinations were also made of the wire microstructure after testing. Ultimate tensile strength values up to 2170 meganewtons per square meter (314000 psi) at 1093 C (2000 F) and 1940 meganewtons per square meter (281 000 psi) at 1204 C (2200 F) were obtained for W-Re-Hf-C wire. The best strength values obtained for a 100-hour rupture life were, 1410 meganewtons per square meter (205 000 psi) at 1093 C (2000 F) and 910 meganewtons per square meter (132 000 psi) at 1240 C (2200 F) for W-Re-Hf-C wire. The properties obtained suggested that the wires studied showed promise as potential fiber reinforcement in the 1093 to 1204 C (2000 to 2200 F) temperature range.

Petrasek, D. W.↗

Effective thermal conductivities of four metal ceramic composite coatings in hydrogen-oxygen rocket firings

An experimental investigation was conducted to determine the effective conductivities of four plasma-arc-sprayed, metal-ceramic gradated coatings on hydrogen-oxygen thrust chambers. The effective thermal conductivities were not a function of pressure or oxidant-to-fuel ratio. The various materials that made up these composites do not seem to affect the thermal conductivity values as much as the differences in the thermal conductivities of the parent materials would lead one to expect. Contact resistance evolving from the spraying process seems to be the controlling factor. The thermal conductivities of all the composites tested fell in the range of 0.75 to 7.5 watts per meter kelvin.

Schacht, R. L.↗

Wind-tunnel calibration and requirements for in-flight use of fixed hemispherical head angle-of-attack and angle-of-sideslip sensors

Wind-tunnel tests were conducted with three different fixed pressure-measuring hemispherical head sensor configurations which were strut-mounted on a nose boom. The tests were performed at free-stream Mach numbers from 0.2 to 3.6. The boom-angle-of-attack range was -6 to 15 deg, and the angle-of-sideslip range was -6 to 6 deg. The test Reynolds numbers were from 3.28 million to 65.6 million per meter. The results were used to obtain angle-of-attack and angle-of-sideslip calibration curves for the configurations. Signal outputs from the hemispherical head sensor had to be specially processed to obtain accurate real-time angle-of-attack and angle-of-sideslip measurements for pilot displays or aircraft systems. Use of the fixed sensors in flight showed them to be rugged and reliable and suitable for use in a high temperature environment.

Montoya, E. J.↗

Selected Hydrologic Applications of LANDSAT-2 Data: an Evaluation

The author has identified the following significant results. Estimates of soil moisture were obtained from visible, near-IR gamma ray and microwave data. Attempts using GOES thermal-IR were unsuccessful due to resolutions (8 km). Microwaves were the most effective at soil moisture estimates, with and without vegetative cover. Gamma rays provided only one value for the test site, produced by many data points obtained from overlapping 150 meter diameter circles. Even though the resulting averaged value was near the averaged field moisture value, this method suffers from atmospheric contaminants, the need to fly at low altitudes, and the necessity of prior calibration of a given site. Visible and near-IR relationships are present for bare fields but appear to be limited to soil moisture levels between 5 and 20%. The densely vegetated alfalfa fields correlated with near-IR reflectance only; soil moisture values from wheat fields showed no relation to either or near-IR MSS data.

Wiesnet, D. R.↗

Ice/frost detection using millimeter wave radiometry

A series of ice detection tests was performed on the shuttle external tank (ET) and on ET target samples using a 35/95 GHz instrumentation radiometer. Ice was formed using liquid nitrogen and water spray inside a test enclosure containing ET spray on foam insulation samples. During cryogenic fueling operations prior to the shuttle orbiter engine firing tests, ice was formed with freon and water over a one meter square section of the ET LOX tank. Data analysis was performed on the ice signatures, collected by the radiometer, using Georgia Tech computing facilities. Data analysis technique developed include: ice signature images of scanned ET target; pixel temperature contour plots; time correlation of target data with ice present versus no ice formation; and ice signature radiometric temperature statistical data, i.e., mean, variance, and standard deviation.

Gagliano, J. A.↗

Raman lidar for the remote measurement of subsurface ocean parameters

The Raman lidar technique was developed for the remote measurement of temperature and salinity profiles. A temperature accuracy of 0.5 degrees Centigrade is attainable in a practical field system for depths of up to 3 diffuse attentuation lengths, which can be 100 meters or more in the open ocean. In this paper field test results are reviewed and performance specifications for typical Raman lidar systems are presented.

Leonard, D. A.↗