Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Final Scientific/Technical Report for "Forward Angle Physics at CMS"

CMS will be used to study the reaction products from nuclear collisions of lead with lead at energies of 1100 TeV and also collisions between lighter elements. CMS is a huge detector array at the LHC (Large Hadron Collider), now under construction at CERN in Geneva, Switzerland. The emphasis in this work will be on the far-forward angles (close to the beam line) which has the highest density of products and for which the Univ. of Iowa group has made major contributions to the design and construction of the detectors (CMS-HF, CMS-ZDC). With a detailed knowledge of all of the forward detectors, this group is uniquely prepared to distinguish real physics from effects caused by peculiarities of the detectors. The work included finishing the detectors and getting them into operation and preparing to study data after the LHC restarts in 2010. The Iowa group also continued to develop improved detectors for use with upgrades to CMS and for other applications. The available energy is almost 30 times that from gold + gold at the present RHIC facility. The new energy regime will open a new window on hot and dense matter physics. The higher energy lengthens the lifetime of a quark gluon plasma and provides additional probes for studying this new form of matter. For example, there is abundant production of jets and heavy quarks with a large cross section for J/{Psi} and {Upsilon} production. The three states of the {Upsilon} are clearly resolved by CMS. The different 'melting' for members of the {Upsilon} family provides information about the nuclear medium. The much wider range of Q{sup 2} and x allow a major extension of the measurements at RHIC. This large increase in energy provides more than just an extension of RHIC results to higher energy. It is expected to reveal a wealth of new phenomena. This will be the first time that sufficient energy is available to produce in the laboratory the strange and poorly understood objects found in high-energy cosmic ray events. The largest system available in cosmic rays is iron on oxygen. Lead on lead is totally new. It is only possible to record a small fraction of the output of CMS. With its intimate knowledge of the forward detectors, the Iowa group needs to have a part in decisions about the selection of events to be saved. Otherwise, events that should have the highest priority may be discarded at the trigger level and lost forever.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absorbed XFEL Dose in the Components of the LCLS X-Ray Optics

There is great concern that the short, intense XFEL pulse of the LCLS will damage the optics that will be placed into the beam. We have analyzed the extent of the problem by considering the anticipated materials and position of the optical components in the beam path, calculated the absorbed dose as a function of photon energy, and compared these doses with the expected doses required (i) to observe rapid degradation due to thermal fatigue, (ii) to reach the melting temperature, or (iii) to actually melt the material. We list the materials that are anticipated to be placed into the Linac Coherent Light Source (LCLS) x-ray free electron laser (XFEL) beam line, their positions, and the absorbed dose, and compare this dose with anticipated damage thresholds.

43 PARTICLE ACCELERATORS↗

Top Quark Properties from CDF and D0

Recent results on top quark properties measured by the CDF and the D0 collaborations are presented, including the top quark charge using a b-jet charge algorithm and soft lepton tagger, spin-correlations in the helicity basis and in the beam line basis, theWboson helicity in top quark decay, the forward-backward charge asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent results from the MINERvA experiment

MINERvA is a dedicated neutrino-nucleus scattering experiment with multiple nuclear targets in the Neutrinos from the Main Injector (NuMI) beam line at Fermilab. MINERvA can provide high precision measurements of neutrino interaction cross sections in the 1 to 20 GeV energy range in support to current and future oscillation experiments. MINERvA can also provide information about the structure of protons and neutrons and about the dynamics affecting neutrino-nucleus interactions. The heart of the MINERvA detector is a fine-grained scintillating tracking cham-ber, surrounded by electromagnetic and hadronic calorimeters. Carbon, iron and lead targets are used to study the effect of the nuclear medium on neutrino-induced interactions. In conclusion, this document summarizes the most recent MINERvA results

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NO$v$A Test Beam Program

NO$\nu$A is a long-baseline off-axis beam neutrino experiment. By measuring $\nu_\mu$ disappearance and $\nu_e$ appearance at the 14 kiloton NO$\nu$A Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NO$\nu$A Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NO$\nu$A detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NO$\nu$A physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beam-line instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of cross section uncertainties on NOvA oscillation analyses

The NOvA experiment is an off-axis long-baseline neutrino oscillation experiment measuring $\nu_{\mu}$ disappearance and $\nu_{e}$ appearance in a $\nu_{\mu}$ beam originating at Fermilab. Oscillations are observed in the far detector relative to measurements made in the near detector, with a full simulation of the beam line and detectors being used to perform extrapolation between them. The neutrino simulation uses the GENIE event generator, which contains implementations of numerous theoretical neutrino interaction models applied to a variety of nuclear targets. However, recent data, recent reanalysis of extant data, and continued development of theoretical models have brought to light deficiencies in the default GENIE cross section model, which informs the predicted spectra used to infer oscillation parameters. We explore how uncertainties in this model, together with modifications to GENIE version 2.12.2 based on external information and NOvA Near Detector (ND) data, affect NOvA's oscillation parameter inferences. We also discuss how these uncertainties can be mitigated by judicious analysis design, including usage of the ND data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Simulations for Ion-Production and Back-Bombardment in GaAs Photo-guns

GaAs-based DC high voltage photo-guns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. Specifically, the operating lifetime is dominated by ion back-bombardment of the photocathode from ionized residual gas. While numerous experiments have been performed to characterize the operating lifetime under various conditions, detailed simulations of the ion back-bombardment mechanism that explains these experiments are lacking. Recently, a new user routine was implemented using the code General Particle Tracer (GPT) to simulate electron impact ionization of residual beam line gas and simultaneously track the incident electron, the ejected electron, and the newly formed ion. This new routine was benchmarked against analytical calculations and then applied to experiments performed at the CEBAF injector at the Thomas Jefferson National Accelerator Facility to study the effectiveness of limiting ions from entering the cathode-anode gap using a positively biased anode. These simulations were performed using detailed 3D field maps produced with CST Microwave Studio describing the photo-gun electrostatics. Discussion of the experiment and the application of this new GPT routine to model the experiments will be presented at the workshop.

Yoskowitz, Joshua↗

The Connection between the Presence of Melanoma and Changes in Fibre Diffraction Patterns

An accurate diagnosis of melanomas at an early stage correlates directly with a better prognosis. However the incidence of melanoma is still increasing along with the number of related deaths. Melanoma cells grow extremely fast, with the result that many patients present after metastasis has occurred, too late for effective treatment. This paper describes the changes in the fibre diffraction patterns of skin that indicate the presence of a melanoma. Identification of these changes would provide an alternative early low-cost, reliable diagnostic test which could be conducted on a regular basis in local radiology facilities using rotating anode X-ray generators or as a mass screening test using suitable small angle x-ray beam-lines at synchrotrons.

43 PARTICLE ACCELERATORS↗

Event Centroiding Applied to Energy-Resolved Neutron Imaging at LANSCE

The energy-dependence of the neutron cross section provides vastly different contrast mechanisms than polychromatic neutron radiography if neutron energies can be selected for imaging applications. In recent years, energy-resolved neutron imaging (ERNI) with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as for quantitative density measurements, was pioneered at the Flight Path 5 beam line at LANSCE and continues to be refined. In this work, we present event centroiding, i.e., the determination of the center-of-gravity of a detection event on an imaging detector to allow sub-pixel spatial resolution and apply it to the many frames collected for energy-resolved neutron imaging at a pulsed neutron source. While event centroiding was demonstrated at thermal neutron sources, it has not been applied to energy-resolved neutron imaging, where the energy resolution requires to be preserved, and we present a quantification of the possible resolution as a function of neutron energy. For the 55 μm pixel size of the detector used for this study, we found a resolution improvement from ~80 μm to ~22 μm using pixel centroiding while fully preserving the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

A MODEL OF WHITE DWARF PULSAR AR SCORPII

A 3.56 hr white dwarf (WD)–M dwarf (MD) close binary system, AR Scorpii, was recently reported to show pulsating emission in radio, IR, optical, and UV, with a 1.97 minute period, which suggests the existence of a WD with a rotation period of 1.95 minutes. We propose a model to explain the temporal and spectral characteristics of the system. The WD is a nearly perpendicular rotator, with both open field line beams sweeping the MD stellar wind periodically. A bow shock propagating into the stellar wind accelerates electrons in the wind. Synchrotron radiation of these shocked electrons can naturally account for the broadband (from radio to X-rays) spectral energy distribution of the system.

79 ASTRONOMY AND ASTROPHYSICS↗

The Elastic Analysis Facility's (EAF's) Contribution to the Future of Analysis at Multi-Experiment Institutions and Future Colliders

The Elastic Analysis Facility (EAF) hosted at Fermi National Accelerator Laboratory (Fermilab) is a platform being developed with the goal of providing a fast and efficient facility for physics analysis. As high-energy physics moves towards collecting larger datasets, such as those from the High-Luminosity LHC, the EAF strives to provide a powerful and adaptable framework for future colliders and multi-experiment institutions. Currently, the EAF supports several experiments including CMS, NOvA, and DUNE as well as serving accelerator physicists and beam line operations through integrated software and secure connections to Fermilab's computing resources. In addition, the EAF was designed with a user-friendly interface, intended to be more intuitive for emerging generations of physicists, that is still accessible for established styles of analysis. The EAF can also achieve better analysis efficiency due to the modernization of software and tools that can better utilize Fermilab's computing power. Furthermore, its design incorporates industry standards whenever possible, enhancing its sustainability and making it a possible template for other national or international laboratories and research facilities. Overall, the EAF is a forward-looking solution that will meet the evolving needs of particle physics, ensuring readiness for future colliders and multi-experiment research institutions.

Chavez, Elise [Wisconsin U., Madison]↗

Diffraction grating transmission efficiencies for XUV and soft X rays

The manufacture and properties of a grating intended for extrasolar X-ray studies are described. The manufacturing process uses a split laser beam exposing an interference pattern on the photoresist-coated glass plated with a nickel parting layer. The grating, supporting structure, and mounting frame are electrodeposited on the nickel parting layer, and the final product is lifted from the glass substrate by selective etching of the nickel. A model was derived which relates the number of counts received in a given order m as a function of photon wavenumber. A 4-deg beam line was used to measure the efficiencies of gold transmission gratings for diffraction of X-rays in the range of 45 to 275 eV. The experimental results are in good agreement with model calculations.

Schnopper, H. W.↗

Secondary gamma-ray production in a coded aperture mask

The application of the coded aperture mask to high energy gamma-ray astronomy will provide the capability of locating a cosmic gamma-ray point source with a precision of a few arc-minutes above 20 MeV. Recent tests using a mask in conjunction with drift chamber detectors have shown that the expected point spread function is achieved over an acceptance cone of 25 deg. A telescope employing this technique differs from a conventional telescope only in that the presence of the mask modifies the radiation field in the vicinity of the detection plane. In addition to reducing the primary photon flux incident on the detector by absorption in the mask elements, the mask will also be a secondary radiator of gamma-rays. The various background components in a CAMTRAC (Coded Aperture Mask Track Chamber) telescope are considered. Monte-Carlo calculations are compared with recent measurements obtained using a prototype instrument in a tagged photon beam line.

Owens, A.↗

Surface sensitive photoemission EXAFS: A new structural tool

A new technique for surface EXAFS has been developed. In this technique the absorption fine structure is observed by monitoring the photoelectrons emitted from core levels as a function of photon energy. The surface sensitivity is achieved by detecting elastic photoelectrons that escape to the vacuum from a few atomic layers near the surface. EXAFS from Mn 3p and F2s outer core levels in MnF2 were measured, the results were compared with transmission EXAFS from Mn ls core level and good agreement was found. This development is significant because: (1) almost all elements have suitable core levels of low binding energy; (2) since photopeaks from adjacent core levels do not cross as the photon energy is varied, the limitations imposed on other surface EXAFS techniques by this interference is removed. Auger electrons, which have fixed kinetic energies and so can cross photopeaks, will generally have low energies if they originate from outer core levels and be unlikely to appear in the EXAFS region of kinetic energies, i.e., in excess of about 50 eV; (3) VUV light is used, which greatly extends the usable range of photon energies; (4) more than one element in a solid may be studied with the same monochromator. The experiments were carried out on the VUV beam line U14A at NSLS.

Choudhary, K. M.↗

Multilayer diffraction at 104 keV

We have measured the diffraction peak of a W:Si synthetic multilayer reflector at 104 keV using the High Energy Bonse-Hart Camera at the X-17B hard X-ray wiggler beam line of the National Synchrotron Light Source at Brookhaven National Laboratory. The characteristics of the diffraction peak are described and compared to theory.

Krieger, Allen S.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with size on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. We have succeeded in producing silicon lenses with a geometry suitable for a 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics. Most recently, we have done several experiments to find the fundamental limits that the anisotropic etch process placed on the etched surface roughness.

Kaaret, Philip↗