Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

On source radiation

The power output from given sources is usually ascertained via an energy flux integral over the normal directions to a remote (far field) surface; an alternative procedure, which utilizes an integral that specifies the direct rate of working by the source on the resultant field, is described and illustrated for both point and continuous source distribution. A comparison between the respective procedures is made in the analysis of sound radiated from a periodic dipole source whose axis performs a periodic plane angular movement about a fixed direction. Thus, adopting a conventional approach, Sretenskii (1956) characterizes the rotating dipole in terms of an infinite number of stationary ones along a pari of orthogonal directions in the plane, and through the far field representation of the latter, arrives at a series development for the instantaneous radiated power, whereas the local manner of power calculation dispenses with the equivalent infinite aggregate of sources and yields a compact analytical result.

Levine, H.↗

Radiation Chemistry and Photochemistry of Ionic Liquids

As our understanding of ionic liquids and their tunable properties has grown, it is possible to see many opportunities for ionic liquids to contribute to the sustainable use of energy. The potential safety and environmental benefits of ionic liquids, as compared to conventional solvents, have attracted interest in their use as processing media for the nuclear fuel cycle. Therefore, an understanding of the interactions of ionizing radiation and photons with ionic liquids is strongly needed. However, the radiation chemistry of ionic liquids is still a relatively unexplored topic although there has been a significant increase in the number of researchers in the field recently. This article provides a brief introduction to ionic liquids and their interesting properties, and recent advances in the radiation chemistry and photochemistry of ionic liquids. In this article, we will mainly focus on excess electron dynamics and radical reaction dynamics. Because solvation dynamics processes in ionic liquids are much slower than in molecular solvents, one of the distinguishing characteristics is that pre-solvated electrons play an important role in ionic liquid radiolysis. It will be also shown that the reaction dynamics of radical ions is significantly different from that observed in molecular solvents because of the Coulombic screening effects and electrostatic interactions in ionic liquids.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of quasi-collisional effects in laboratory and astrophysical plasmas

High-amplitude turbulence excited in plasmas at small-scales can leave imprint on the radiation produced by (accelerated) plasma particles -- mostly electrons in electron-ion plasmas and both electrons and positrons in lepton pair plasmas. Furthermore, turbulence is known to introduce "effective collisional" effects -- anomalous resistivity, dissipation, diffusion, etc. -- in the otherwise collisionless plasmas. These effective collisions affect radiation transfer and modify optical and magneto-optic effects -- the transmittance and reflectivity coefficients, Faraday rotation, etc. Note that the effective collisions considered in this project are not resonant wave-particle interactions, but much less conventional randomization of particles’ paths. Therefore, we colloquially refer them to as "quasi-collisions". The study of quasi-collisions on transport, radiative and optical properties of plasmas is the main focus of this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic particle injector for fast time response disruption mitigation in tokamaks

A novel, rapid time-response, disruption mitigation system referred to as the electromagnetic particle injector (EPI) is described. This method can accurately deliver the radiative payload to the plasma center on a <10 ms time scale, much faster, and deeper, than what can be achieved using conventional methods. The EPI system accelerates a sabot electromagnetically. The sabot is a metallic capsule that can be accelerated to desired velocities by an electromagnetic impeller. At the end of its acceleration, within 2 ms, the sabot will release a radiative payload, which is composed of low-z granules, or a shell pellet containing smaller pellets. The primary advantage of the EPI concept over gas propelled systems is its potential to meet short warning time scales, while accurately delivering the required particle size and materials at the velocities needed for achieving the required penetration depth in high power ITER-scale discharges for thermal and runaway current disruption mitigation. In conclusion, the present experimental tests from a prototype system have demonstrated the acceleration of a 3.2 g sabot to over 150 m s –1 within 1.5 ms, consistent with the calculations, giving some degree of confidence that larger ITER-scale injector can be developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Particle Injector for Fast Time Response Disruption Mitigation in Tokamaks

A novel, rapid time-response, disruption mitigation system referred to as the Electromagnetic Particle Injector (EPI) is described. This method can accurately deliver the radiative payload to the plasma center on a <10 ms time scale, much faster, and deeper, than what can be achieved using conventional methods. The EPI system accelerates a sabot electromagnetically. The sabot is a metallic capsule that can be accelerated to desired velocities by an electromagnetic impeller. At the end of its acceleration, within 2 ms, the sabot will release a radiative payload, which is composed of low-z granules, or a shell pellet containing smaller pellets. The primary advantage of the EPI concept over gas propelled systems is its potential to meet short warning time scales, while accurately delivering the required particle size and materials at the velocities needed for achieving the required penetration depth in high power ITER-scale discharges for thermal and runaway current disruption mitigation. The present experimental tests from a prototype system have demonstrated the acceleration of a 3.2 g sabot to over 150 m/s within 1.5 ms, consistent with the calculations, giving some degree of confidence that larger ITER-scale injector can be developed.

High velocity↗

Simultaneous reduction of radiation dose and scatter for CBCT by using collimators

Purpose: On-board cone-beam CT (CBCT) imaging has been widely available in radiotherapy clinic for target localization. However, the extra radiation dose from CBCT is always a concern for its frequent use. Additionally, the relatively large scatter in CBCT often degrades the image quality. By using collimators, some of the X-rays can be stopped from reaching the patient and the detectors, hence both the scatter and the patient doses are simultaneously reduced. The authors show in this work that the collimated CBCT data can be reconstructed without any noticeable artifacts for certain collimator blocking ratios and blocking patterns, and the focus of this work is to study the relationship between the image quality and these two collimator factors.Methods: A CBCT system with collimators was simulated following the typical geometry used in clinic. Different collimator designs were tested by varying the size and the number of the collimator slits, and at the same time, the ratio of transmitted beams to total beams was varied from 100% to 10%, resulting in hundreds of different simulation scenarios. Lung and pelvis phantoms created from patients CT images were used in the simulations, and an iterative reconstruction algorithm using the compressed sensing technique was adopted. The image quality was examined by root mean square errors (RMSEs) and compared with the conventional CBCT images.Results: The CBCT image quality increases as the amount of beams passing through the collimators increases, and decreases as the size of the collimator slits increases. With ultra-high resolution collimators, the RMSEs were comparable to the conventional CBCT image quality until the beam transmission rate is reduced below 25%.Conclusions: Collimators can reduce the scatters and radiation dose, however, the collimated CBCT image quality is strongly dependent on both the collimator blocking ratio and the blocking pattern. To achieve image quality comparable to the conventional CBCT, the amount of information and data format must be adequate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Probing Diffuse Polymer Brush Interfaces Using Resonant Soft X-ray Scattering

The success of a neutron or x-ray scattering experiment relies on sufficient signal from the system being studied. The intensity of scattered radiation depends on instrument resolution, the structure of the scattering elements, and the interaction between the incident radiation and the sample—so-called ‘scattering contrast’. The contrast depends on the square of the difference in the scattering length densities (SLDs) for each component, and each SLD depends on the atoms and radiation involved (eq. 1). For neutrons, the scattering lengths bi are specific to the type of nuclei involved. For conventional x-ray scattering, b i depends on the electron density and thus the atomic number Z.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An enriched finite element model with q-refinement for radiative boundary layers in glass cooling

Radiative cooling in glass manufacturing is simulated using the partition of unity finite element method. The governing equations consist of a semi-linear transient heat equation for the temperature field and a stationary simplified P{sub 1} approximation for the radiation in non-grey semitransparent media. To integrate the coupled equations in time we consider a linearly implicit scheme in the finite element framework. A class of hyperbolic enrichment functions is proposed to resolve boundary layers near the enclosure walls. Using an industrial electromagnetic spectrum, the proposed method shows an immense reduction in the number of degrees of freedom required to achieve a certain accuracy compared to the conventional h-version finite element method. Furthermore the method shows a stable behaviour in treating the boundary layers which is shown by studying the solution close to the domain boundaries. The time integration choice is essential to implement a q-refinement procedure introduced in the current study. The enrichment is refined with respect to the steepness of the solution gradient near the domain boundary in the first few time steps and is shown to lead to a further significant reduction on top of what is already achieved with the enrichment. The performance of the proposed method is analysed for glass annealing in two enclosures where the simplified P{sub 1} approximation solution with the partition of unity method, the conventional finite element method and the finite difference method are compared to each other and to the full radiative heat transfer as well as the canonical Rosseland model.

97 MATHEMATICS AND COMPUTING↗

WE-D-BRE-04: Modeling Optimal Concurrent Chemotherapy Schedules

Purpose: Concurrent chemo-radiation therapy (CCRT) has become a more common cancer treatment option with a better tumor control rate for several tumor sites, including head and neck and lung cancer. In this work, possible optimal chemotherapy schedules were investigated by implementing chemotherapy cell-kill into a tumor response model of RT. Methods: The chemotherapy effect has been added into a published model (Jeong et al., PMB (2013) 58:4897), in which the tumor response to RT can be simulated with the effects of hypoxia and proliferation. Based on the two-compartment pharmacokinetic model, the temporal concentration of chemotherapy agent was estimated. Log cell-kill was assumed and the cell-kill constant was estimated from the observed increase in local control due to concurrent chemotherapy. For a simplified two cycle CCRT regime, several different starting times and intervals were simulated with conventional RT regime (2Gy/fx, 5fx/wk). The effectiveness of CCRT was evaluated in terms of reduction in radiation dose required for 50% of control to find the optimal chemotherapy schedule. Results: Assuming the typical slope of dose response curve (γ50=2), the observed 10% increase in local control rate was evaluated to be equivalent to an extra RT dose of about 4 Gy, from which the cell-kill rate of chemotherapy was derived to be about 0.35. Best response was obtained when chemotherapy was started at about 3 weeks after RT began. As the interval between two cycles decreases, the efficacy of chemotherapy increases with broader range of optimal starting times. Conclusion: The effect of chemotherapy has been implemented into the resource-conservation tumor response model to investigate CCRT. The results suggest that the concurrent chemotherapy might be more effective when delayed for about 3 weeks, due to lower tumor burden and a larger fraction of proliferating cells after reoxygenation.

60 APPLIED LIFE SCIENCES↗

Changes in Tropical Clouds and Atmospheric Circulation Associated with Rapid Adjustment Induced by Increased Atmospheric CO2 – A Multiscale Modeling Framework Study

The radiative heating increase due to increased CO2 concentration is the primary source for the rapid adjustment of atmospheric circulation and clouds. In this study, we investigate the rapid adjustment resulting from doubling of CO2 and its physical mechanism using a multiscale modeling framework (MMF). The MMF includes an advanced higher-order turbulence closure in its cloud-resolving model component and simulates realistic shallow and deep cloud climatology and boundary layer turbulence. The rapid adjustment over the tropics is characterized by 1) reduced ascent and descent strengths over the ocean, 2) increased lower tropospheric stability (LTS) over the subsidence region, 3) shoaling of planetary boundary layers over the ocean, 4) increased deep convection over lands and shift of cloud coverage from the ocean to lands, and 5) reduced sensible (SH) and latent heat (LH) fluxes over the oceanic deep convective regions. Unlike conventional general circulation models and another MMF, a reduction in the global-mean shortwave cloud radiative cooling is not simulated, due to the increase in low clouds at lower altitudes over the ocean, resulting from reduced cloud-top entrainment due to strengthened inversion. Changes in regional circulation play a key role in cloud changes and shift of cloud coverage to lands. Weaker energy transport resulting from water vapor and cloud CO2 masking effects reduces the upward motion and convective clouds in the oceanic regions. The ocean-land transports are linked to the partitioning of surface SH and LH fluxes that increases humidity over lands and enhances deep convection over the tropical lands.

Xu, Kuan-Man↗

PET/CT in radiation oncology

PET/CT is an effective tool for the diagnosis, staging and restaging of cancer patients. It combines the complementary information of functional PET images and anatomical CT images in one imaging session. Conventional stand-alone PET has been replaced by PET/CT for improved patient comfort, patient throughput, and most importantly the proven clinical outcome of PET/CT over that of PET and that of separate PET and CT. There are over two thousand PET/CT scanners installed worldwide since 2001. Oncology is the main application for PET/CT. Fluorine-18 deoxyglucose is the choice of radiopharmaceutical in PET for imaging the glucose uptake in tissues, correlated with an increased rate of glycolysis in many tumor cells. New molecular targeted agents are being developed to improve the accuracy of targeting different disease states and assessing therapeutic response. Over 50% of cancer patients receive radiation therapy (RT) in the course of their disease treatment. Clinical data have demonstrated that the information provided by PET/CT often changes patient management of the patient and/or modifies the RT plan from conventional CT simulation. The application of PET/CT in RT is growing and will become increasingly important. Continuing improvement of PET/CT instrumentation will also make it easier for radiation oncologists to integrate PET/CT in RT. The purpose of this article is to provide a review of the current PET/CT technology, to project the future development of PET and CT for PET/CT, and to discuss some issues in adopting PET/CT in RT and potential improvements in PET/CT simulation of the thorax in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nondestructive evaluation of nuclear-grade graphite

The material of choice for the core of the high-temperature gas-cooled reactors being developed by the U.S. Department of Energy's Next Generation Nuclear Plant Program is graphite. Graphite is a composite material whose properties are highly dependent on the base material and manufacturing methods. In addition to the material variations intrinsic to the manufacturing process, graphite will also undergo changes in material properties resulting from radiation damage and possible oxidation within the reactor. Idaho National Laboratory is presently evaluating the viability of conventional nondestructive evaluation techniques to characterize the material variations inherent to manufacturing and in-service degradation. Approaches of interest include x-ray radiography, eddy currents, and ultrasonics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IFNgamma-inducible CXCL10/CXCR3 axis alters the sensitivity of HEp-2 cells to ionizing radiation

Highlights: • IFNgamma/CXCL10/CXCR3 are necessary for effective IR-induced HEp-2 cell killing. • Local IR showed fewer effects on tumor burden in mice carrying CXCL10-KO xenografts. • Loss of CXCL10 showed blockage in the G0/G1 phase when exposed to a moderate dose of IR. Radiotherapy is a conventional approach for anti-cancer treatment, killing tumor cells through damaging cellular DNA. While increasing studies have demonstrated that tumors generated the tolerance to radiation and tumor immune system was found to be correlated to radiotherapy resistance. Therefore, it is critical to identify potential immune factors associated with the efficacy of radiotherapy. Here in this study, we evaluated the sensitivities of different tumor cells to radiation and determined HEp-2 cells as the radio-resistant tumor cells for further investigation. IFNgamma as a key regulator of host immune response showed the potential to sensitize tumors to ionizing radiation (IR). Besides, IFNgamma-induced CXC chemokine ligand 10 (CXCL10) was found to be necessary for effective IR-induced killing of cultured HEp-2 cells. Increased clonogenic survival was observed in CXCL10-depleted HEp-2 cells and CXCL10-KO cells. Additionally, the loss of CXCL10 in HEp-2 cells showed less progression of the G0/G1 phase to G2/M when exposed to IR (8 Gy). Local IR (20 Gy) to nude mice bearing HEp-2 tumors significantly reduced tumor burden, while fewer effects on tumor burden in mice carrying CXCL10-KO tumors were observed. We furtherly evaluated the possible roles the chemokine receptor CXCR3 plays in mediating the sensitivity of cultured HEp-2 cells to IR. Altered expression of CXCR3 in HEp-2 cells affected IR-induced killing of HEp-2 cells. Our data suggest the IFNgamma-activated CXCL10/CXCR3 axis may contribute to the effective radiation-induced killing of HEp-2 cells in vitro.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Polyolefin-Based Aerogels

An organic polybutadiene (PB) rubberbased aerogel insulation material was developed that will provide superior thermal insulation and inherent radiation protection, exhibiting the flexibility, resiliency, toughness, and durability typical of the parent polymer, yet with the low density and superior insulation properties associated with the aerogels. The rubbery behaviors of the PB rubber-based aerogels are able to overcome the weak and brittle nature of conventional inorganic and organic aerogel insulation materials. Additionally, with higher content of hydrogen in their structure, the PB rubber aerogels will also provide inherently better radiation protection than those of inorganic and carbon aerogels. Since PB rubber aerogels also exhibit good hydrophobicity due to their hydrocarbon molecular structure, they will provide better performance reliability and durability as well as simpler, more economic, and environmentally friendly production over the conventional silica or other inorganic-based aerogels, which require chemical treatment to make them hydrophobic. Inorganic aerogels such as silica aerogels demonstrate many unusual and useful properties. There are several strategies to overcoming the drawbacks associated with the weakness and brittleness of silica aerogels. Development of the flexible fiber-reinforced silica aerogel composite blanket has proven one promising approach, providing a conveniently fielded form factor that is relatively robust toward handling in industrial environments compared to silica aerogel monoliths. However, the flexible silica aerogel composites still have a brittle, dusty character that may be undesirable, or even intolerable, in certain applications. Although the cross-linked organic aerogels such as resorcinol-formaldehyde (RF), polyisocyanurate, and cellulose aerogels show very high impact strength, they are also very brittle with little elongation (i.e., less rubbery). Also, silica and carbon aerogels are less efficient radiation shielding materials due to their lower content of hydrogen element. The present invention relates to maleinized polybutadiene (or polybutadiene adducted with maleic anhydride)- based aerogel monoliths and composites, and the methods for preparation. Hereafter, they are collectively referred to as polybutadiene aerogels. Specifically, the polybutadiene aerogels of the present invention are prepared by mixing a maleinized polybutadiene resin, a hardener containing a maleic anhydride reactive group, and a catalyst in a suitable solvent, and maintaining the mixture in a quiescent state for a sufficient period of time to form a polymeric gel. After aging at elevated temperatures for a period of time to provide uniformly stronger wet gels, the micro porous maleinized polybutadiene- based aerogel is then obtained by removing interstitial solvent by supercritical drying. The mesoporous maleinized polybutadiene-based aerogels contain an open-pore structure, which provides inherently hydrophobic, flexible, nearly unbreakable, less dusty aerogels with excellent thermal and physical properties. The materials can be used as thermal and acoustic insulation, radiation shielding, and vibration-damping materials. The organic PB-based rubber aerogels are very flexible, no-dust, and hydrophobic organics that demonstrated the following ranges of typical properties: densities of 0.08 to 0.255 grams per cubic centimeters, shrinkage factor (raerogel/rtarget) = 1.2 to 2.84, and thermal conductivity values of 20.0 to 35.0 mW/m-K.

Lee, Je Kyun↗

Preoperative Short-Course Concurrent Chemoradiation Therapy Followed by Delayed Surgery for Locally Advanced Rectal Cancer: A Phase 2 Multicenter Study (KROG 10-01)

Purpose: A prospective phase 2 multicenter trial was performed to investigate the efficacy and safety of preoperative short-course concurrent chemoradiation therapy (CRT) followed by delayed surgery for patients with locally advanced rectal cancer. Methods and Materials: Seventy-three patients with cT3-4 rectal cancer were enrolled. Radiation therapy of 25 Gy in 5 fractions was delivered over 5 consecutive days using helical tomotherapy. Concurrent chemotherapy was administered on the same 5 days with intravenous bolus injection of 5-fluorouracil (400 mg/m{sup 2}/day) and leucovorin (20 mg/m{sup 2}/day). After 4 to 8 weeks, total mesorectal excision was performed. The primary endpoint was the pathologic downstaging (ypStage 0-I) rate, and secondary endpoints included tumor regression grade, tumor volume reduction rate, and toxicity. Results: Seventy-one patients completed the planned preoperative CRT and surgery. Downstaging occurred in 20 (28.2%) patients, including 1 (1.4%) with a pathologic complete response. Favorable tumor regression (grade 4-3) was observed in 4 (5.6%) patients, and the mean tumor volume reduction rate was 62.5 ± 21.3%. Severe (grade ≥3) treatment toxicities were reported in 27 (38%) patients from CRT until 3 months after surgery. Conclusions: Preoperative short-course concurrent CRT followed by delayed surgery for patients with locally advanced rectal cancer demonstrated poor pathologic responses compared with conventional long-course CRT, and it yielded considerable toxicities despite the use of an advanced radiation therapy technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation characteristics of femtosecond laser-induced plasma channel Vee antenna

A virtual reconfigurable plasma Vee antenna consisting of a set of laser plasma filaments produced by femtosecond laser pulses in air is investigated in this paper. The calculation results show that radiation pattern becomes more complex and gain shows initially rapid rise but gradually saturate as the leg length increases, but the pattern and gain are not seriously affected by the plasma conductivity; particularly, the gain of the Vee antenna with plasma conductivity σ = 100S/m can reach about 80% of that of a copper antenna. Radiation efficiency of the antenna has shown a strong dependence on radius of the antenna leg, and an efficiency of 65%, considered to have a proper performance, can be obtained with the channel radius of about 10 mm. Apex angle variation can lead to significant change of the radiation pattern and influence the gain; the best apex angle corresponding to maximal gain and good directivity for the third resonance antenna leg length is found to be at 74° at 600 MHz and σ = 100 S/m. The calculation has shown that at terawatt laser power level, the plasma channel conductivity is close to that of conventional plasma antenna, and peak gain of the Vee antenna is more than 8 dB with a good directivity. In addition, the radiation pattern of special Vee antennas with apex angle 180°-dipole antennas, for first and third resonance leg lengths, is compared and underneath physics of the difference is given. The laser-induced plasma channel antenna is especially suitable for achieving good directivity and gain, which has advantage over conventional plasma antenna with gas discharge tube or metal antenna.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An in vivo dose verification method for SBRT–VMAT delivery using the EPID

Purpose: Radiation treatments have become increasingly more complex with the development of volumetric modulated arc therapy (VMAT) and the use of stereotactic body radiation therapy (SBRT). SBRT involves the delivery of substantially larger doses over fewer fractions than conventional therapy. SBRT–VMAT treatments will strongly benefit from in vivo patient dose verification, as any errors in delivery can be more detrimental to the radiobiology of the patient as compared to conventional therapy. Electronic portal imaging devices (EPIDs) are available on most commercial linear accelerators (Linacs) and their documented use for dosimetry makes them valuable tools for patient dose verification. In this work, the authors customize and validate a physics-based model which utilizes on-treatment EPID images to reconstruct the 3D dose delivered to the patient during SBRT–VMAT delivery. Methods: The SBRT Linac head, including jaws, multileaf collimators, and flattening filter, were modeled using Monte Carlo methods and verified with measured data. The simulation provides energy spectrum data that are used by their “forward” model to then accurately predict fluence generated by a SBRT beam at a plane above the patient. This fluence is then transported through the patient and then the dose to the phosphor layer in the EPID is calculated. Their “inverse” model back-projects the EPID measured focal fluence to a plane upstream of the patient and recombines it with the extra-focal fluence predicted by the forward model. This estimate of total delivered fluence is then forward projected onto the patient’s density matrix and a collapsed cone convolution algorithm calculates the dose delivered to the patient. The model was tested by reconstructing the dose for two prostate, three lung, and two spine SBRT–VMAT treatment fractions delivered to an anthropomorphic phantom. It was further validated against actual patient data for a lung and spine SBRT–VMAT plan. The results were verified with the treatment planning system (TPS) (ECLIPSE AAA) dose calculation. Results: The SBRT–VMAT reconstruction model performed very well when compared to the TPS. A stringent 2%/2 mm χ-comparison calculation gave pass rates better than 91% for the prostate plans, 88% for the lung plans, and 86% for the spine plans for voxels containing 80% or more of the prescribed dose. Patient data were 86% for the lung and 95% for the spine. A 3%/3 mm χ-comparison was also performed and gave pass rates better than 93% for all plan types. Conclusions: The authors have customized and validated a robust, physics-based model that calculates the delivered dose to a patient for SBRT–VMAT delivery using on-treatment EPID images. The accuracy of the results indicates that this approach is suitable for clinical implementation. Future work will incorporate this model into both offline and real-time clinical adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Scanning and Defocusing Properties of Microstrip Reflectarray Antennas

A symmetric reflectarray, consisting of variable-size square patch elements with a commonly used mathematical model for the horn in the form of a cosine function, has been designed using the transmit mode technique for different f/D ratios with 10 dB edge taper. Subsequently, the antennas were analyzed for the radiation pattern and gain. The infinite array model was used to determine the reflection phase of each patch element in the design and analysis codes. By displacing the feed laterally, the scan characteristics were obtained, such as the beam deviation factor, gain loss, and pattern degradation. The properties of reflect arrays were compared to those of the conventional paraboloidal reflectors. The same procedure was used to study the scan properties of offset reflectarrays. There is no cross-polarized radiation in the principal planes for a symmetric system. Cross-polarized radiation exists in non-principal planes off broadside in symmetric systems, with greater levels for larger values of subtended angles. Such cross-polarized radiation level increases with subtended angle just as cross-polarization level increases with decreasing values of f/D ratios for symmetric paraboloids in non-principal planes. Pattern distortions and gain loss were found to be more severe in the case of a microstrip reflectarray compared to the conventional parabolic reflector. The scan performance of the reflect arrays was found to improve with f/D ratios as is true for paraboloids. In general, scanning by means of displaced feed is limited to a few beam - widths in reflectarrays. Feed displacement in the axial direction of a symmetric reflectarray was investigated and compared to that of paraboloids. The gain loss due to the defocused feed of a reflectarray was found to be nearly the same as that of a paraboloid of the same subtended angle for larger values of f/D, and for displacements away from the antenna. The gain loss of an axially defocused reflectarray was found to be greater than that of a paraboloid for displacements closer to the antenna, especially for smaller values of f/D. In general, the performance of a defocused reflectarray was found to be poorer than that of a comparable paraboloid reflector.

Rengarajan, Sembiam↗