Search NASA⌕ Search

SEARCH · Search NASA

Results for “deterministic processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

903 records · Page 51

Stochastic noise characteristics in matrix inversion tomosynthesis (MITS)

Matrix inversion tomosynthesis (MITS) uses known imaging geometry and linear systems theory to deterministically separate in-plane detail from residual tomographic blur in a set of conventional tomosynthesis (''shift-and-add'') planes. A previous investigation explored the effect of scan angle (ANG), number of projections (N), and number of reconstructed planes (NP) on the MITS impulse response and modulation transfer function characteristics, and concluded that ANG=20 deg., N=71, and NP=69 is the optimal MITS imaging technique for chest imaging on our prototype tomosynthesis system. This article examines the effect of ANG, N, and NP on the MITS exposure-normalized noise power spectra (ENNPS) and seeks to confirm that the imaging parameters selected previously by an analysis of the MITS impulse response also yield reasonable stochastic properties in MITS reconstructed planes. ENNPS curves were generated for experimentally acquired mean-subtracted projection images, conventional tomosynthesis planes, and MITS planes with varying combinations of the parameters ANG, N, and NP. Image data were collected using a prototype tomosynthesis system, with 11.4 cm acrylic placed near the image receptor to produce lung-equivalent beam hardening and scattered radiation. Ten identically acquired tomosynthesis data sets (realizations) were collected for each selected technique and used to generate ensemble mean images that were subtracted from individual image realizations prior to noise power spectra (NPS) estimation. NPS curves were normalized to account for differences in entrance exposure (as measured with an ion chamber), yielding estimates of the ENNPS for each technique. Results suggest that mid- and high-frequency noise in MITS planes is fairly equivalent in magnitude to noise in conventional tomosynthesis planes, but low-frequency noise is amplified in the most anterior and posterior reconstruction planes. Selecting the largest available number of projections (N=71) does not incur any appreciable additive electronic noise penalty compared to using fewer projections for roughly equivalent cumulative exposure. Stochastic noise is minimized by maximizing N and NP but increases with increasing ANG. The noise trend results for NP and ANG are contrary to what would be predicted by simply considering the MITS matrix conditioning and likely result from the interplay between noise correlation and the polarity of the MITS filters. From this study, the authors conclude that the previously determined optimal MITS imaging strategy based on impulse response considerations produces somewhat suboptimal stochastic noise characteristics, but is probably still the best technique for MITS imaging of the chest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian nonrigid registration method to enhance intraoperative target definition in image-guided prostate procedures through uncertainty characterization

Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.

60 APPLIED LIFE SCIENCES↗

Modified Closures in Monte Carlo Algorithms for Diffusive Binary Stochastic Media Transport Problems

In a stochastic medium, the material properties at a given spatial location are known only statistically. The most common approach to solving particle transport problems involving binary stochastic media (BSM) is to use the atomic mix approximation in which the transport problem is solved using homogenized (volume-averaged) material properties. A common deterministic model developed for solving BSM particle transport problems is the Levermore-Pomraning (LP) model. Zimmerman and Adams proposed a Monte Carlo algorithm (Algorithm A) that solves the LP equations and another Monte Carlo algorithm (Algorithm B) that locally preserves the sampled material realization; we refer to these Monte Carlo algorithms as the LP and LPLRP (LP local realization preserving) algorithms, respectively. One-dimensional (1D) planar geometry benchmark studies have shown that the LPLRP algorithm is often significantly more accurate than the LP algorithm for problems with an incident angular flux as well as for problems with an interior source. The LPLRP algorithm implementation in these benchmark comparisons made explicit use of the one-dimensional nature of the problem. The LP model is derived by assuming an 'upwind' closure in the coupling term relating the two materials in a binary stochastic medium. Su and Pomraning developed a modified form of this closure by considering the small correlation length limit and requiring the modified closure to produce the correct exponential decay for a source-free half-line albedo problem in rod geometry. They concluded that the modified closure is generally not inferior to the LP closure and in some cases is significantly better. Brantley investigated the use of the Su-Pomraning (SP) closure in the Monte Carlo LP algorithm (LP-SP) for the suite of benchmark problems and concluded that 1) the LP-SP algorithm was somewhat more accurate overall than the LP algorithm and somewhat less accurate overall than the LPLRP algorithm for an incident angular flux benchmark suite, and 2) the LP-SP algorithm was generally the least accurate of the algorithms for an interior source benchmark suite. Larsen et al. performed an asymptotic analysis of the transport equation in 1D planar geometry for the situation in which the physical system is 1) a random binary stochastic medium with material macroscopic total cross sections and mean slab width values of O(1) or smaller and 2) optically thick with weak absorption and sources at each spatial point and therefore globally diffusive. The asymptotic analysis demonstrates that, under these assumptions, the transport equation limits to the conventional diffusion equation with atomically-mixed (volume-averaged) material properties. Larsen et al. also demonstrate that, under these same assumptions, the LP equations asymptotically limit to an atomically-mixed diffusion equation with a diffusion coefficient that is too large, leading to an unphysical flattening of the ensemble-averaged scalar flux distribution. Vasques and Yadav recently performed an asymptotic analysis of an adjusted Levermore-Pomraning closure in which the Markovian transition functions are rescaled such that the equations asymptotically limit to the correct atomically-mixed diffusion equation; we refer to this model as LP-VY. In this paper, we demonstrate that the adjusted LP closure proposed by Vasques and Yadav is a special case of the SP closure obtained by assuming that the absorption cross sections in the two materials are equal. We further demonstrate that the Su-Pomraning closure has the correct asymptotic limit for the diffusive physical system and is therefore an appropriate closure for these problems. We also describe how to incorporate these various closures into the Monte Carlo LP and LPLRP particle transport algorithms, and we present numerical results comparing the accuracy of the Monte Carlo LP, LP-VY, LP-SP, LPLRP, and LPLRP-SP algorithms for the set of diffusive benchmark problems. We demonstrated that the SP closure has the correct asymptotic limit for the diffusive physical system under investigation in this paper and that the VY closure is a special case of the SP closure obtained by assuming equal absorption in the two materials. Both of these closures are readily implemented in the Monte Carlo LP and LPLRP algorithms for particle transport in BSM. Through numerical comparisons to a diffusive benchmark suite, we confirmed that 1) the LP and LPLRP algorithms do not limit to the appropriate diffusion solution and 2) the LP-VY, LP-SP, and LPLRP-SP algorithms limit to the appropriate diffusion solution and are of comparable accuracy. The LPLRP algorithm has been shown to be generally more accurate than the LP algorithm for non-diffusive problems. However, the numerical results in this paper indicate that the LPLRP algorithm does not limit to the correct diffusion equation for the asymptotic limit under consideration. The work in this paper demonstrates that the SP algorithm does limit to the correct diffusion equation for the asymptotic limit considered. Future work will investigate the possibility of whether the LPLRP-SP algorithm is accurate for both diffusive and non-diffusive problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗