Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A High-Voltage Silicon JFET for the HV-MUX in ATLAS ITk

We present a new kind of silicon device: a High-Voltage vertical JFET, initially conceived as a candidate for the High-Voltage Multiplexing switch in the ATLAS upgrade of the silicon microstrip Inner Tracker (ITk). It is based on a vertical structure, with the drain being the epitaxial layer. Both n-type and p-type HV-JFETs have been successfully fabricated in the silicon processing facility of Brookhaven National Laboratory. Probe station measurements of un-irradiated devices show low leakage currents and high breakdown voltages (up to 600V) in the OFF state, and high currents in the ON state, which satisfy the requirements for the switch, at least before irradiation. Proton and neutron irradiation are planned to test the suitability of this device at the radiation levels foreseen in the ITk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Some aspects of achieving an ultimate accuracy during insertion device magnetic measurements by a Hall probe

An extensive test of a new Senis 2-axis Hall probe was done at the Advanced Photon Source using the Undulator A device and calibration system. This new probe has clear advantages compared with previously used Bell and Sentron Hall probes: very stable zero offset (less than the noise of 0.026 G) and compensated planar Hall effect. It can be used with proper calibration even for first and second field integral measurements. A comparison with reference measurements by long stretched coil shows that the difference in the first field integral measurement results for a 2.4-m-long Undulator A device is between 17 G cm for the best of four Hall probes used for the test and 51 G cm for the worst of them for all gap ranges from 10.5 mm to 150 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determination methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Framework for Quantifying Lidar Uncertainty

As wind turbine sizes increase and wind energy expands to more complex and remote sites, remote sensing devices such as lidars are expected to play a key role in wind resource assessment and power performance testing. The switch to remote sensing devices represents a paradigm shift in the way the wind industry typically obtains and interprets measurement data for wind energy. For example, the measurement techniques and sources of uncertainty for a remote sensing device are vastly different from those associated with a cup anemometer on a meteorological tower. Current IEC standards discuss uncertainty due to mounting, calibration, and classification of the remote sensing device, among other parameters. Values of the uncertainty are typically given as a function of the mean wind speed measured by a reference device. However, real-world experience has shown that lidar performance is highly dependent on atmospheric conditions, such as wind shear, turbulence, and aerosol content. At present, these conditions are not directly incorporated into the estimated uncertainty of a lidar device. In this presentation, we propose the development of a new lidar uncertainty framework that adapts to current flow conditions and more accurately represents the actual uncertainty inherent in lidar measurements under different conditions. In this new framework, sources of uncertainty are identified for estimation of the line-of-sight wind speed and reconstruction of the three-dimensional wind field. These sources are then related to physical processes caused by the atmosphere and lidar operating conditions. The framework is applied to lidar data from an operational wind farm to assess the ability of the framework to predict errors in lidar-measured wind speed.

17 WIND ENERGY↗

X-pinch source of subnanosecond soft X-ray pulses based on small-sized low-inductance current generator

For the first time, the regime of a micrometer-size hot spot formation is impemented for an X-pinch in a plasma, which is fed from a current generator based on low-inductance capacitors and rapid current switches. The configurations of X-pinches, which can be used effectively as point sources of soft X-rays with this type of current generator, are determined. A prototype of a small-size radiation source for high-resolution point projection X-ray radiography has been constructed. The main parameters of X-pinch as a radiation source are analyzed and compared with X-pinch parameters in high-voltage setups with shaping lines. An analysis of the data on the operation of X-pinches in generators with different parameters has led to simple relations that can be used to select optimal initial X-pinch parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Charge-Coupled Devices to Characterize Neutron Events

Ultra-cold neutrons (UCNs) are free neutrons with less than 300 neV of kinetic energy. UCNs are useful for studying position-dependent quantum states, as they are only influenced by Earth’s gravity. Precise measurements of these quantum states can give great insight into dark matter, dark energy, and quantum gravity. We have been calibrating and testing a charge-coupled device (CCD) so that it can be coated with boron-10 to track the reaction products produced between the boron and UCNs. Additionally, we have been using a simulation software package called The Stopping and Range of Ions in Matter (SRIM), which uses Monte Carlo methods to track ions in a chosen target. This package is useful to find a correlation between incident ion angles and 2D variance of the CCD hit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in the pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will done on additional MLPE devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

14 SOLAR ENERGY↗

The Effect of Gamma Radiation Exposure on Active Silicon Photonic Device Performance Metrics

In this study, we test Si vertical junction disk modulators and waveguide-integrated Ge PIN photodiodes to see how the key performance metrics are affected by 60Co gamma radiation (total ionizing dose), a common proxy for simulating a mix of high energy ion particle flux. It is found that reverse bias dark current increases significantly for both devices after 1 Mrad(Si) exposure. Whereas the bandwidth of the Si disk modulator decreases by 6.5 % after 1 Mrad(Si) dose, the bandwidth of the Ge PIN photodiode appears to be unaffected. The increased sensitivity of the Si disk modulator bandwidth to gamma radiation is hypothesized to be caused by a decrease in the carrier concentration of the junction with a resulting increase in p-n junction RC time constant. The Ge PIN photodiode is relatively insensitive to the surface effects because the absorption happens away from the SiO2-Ge interface and the gamma radiation has a minimal effect on carrier mobility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Navy Wave Energy Test Site – Research Update

Navy Wave Energy Test Site – Research Update U.S. Marine Corps Base Hawaii, Kaneohe 30m, 60m, 80m berths in place, grid-connected First device deployed, second Feb 2016, third Sep 2016 HNEI role Acoustic, EMF, ecological, sediment transport measurements Independent device durability and performance analysis Site-dedicated support vessel/maintenance protocol development

16 TIDAL AND WAVE POWER↗

Influence of Electrode Interfaces on the Stability of Perovskite Solar Cells: Reduced Degradation Using MoO x /Al for Hole Collection

We investigated and characterized the stability of the power output from methylammonium lead iodide perovskite photovoltaic devices produced with various hole-collecting anode configurations consisting of Au, Ag, MoOx/Au, MoOx/Ag, and MoOx/Al. The unencapsulated devices were operated under constant illumination and constant load conditions in laboratory ambient with periodic current-voltage testing. Although the initial efficiencies of devices were comparable across these configurations, the stability of these devices varied significantly due to subtle differences in the electrode structure. Specifically, we found that devices with MoOx/Al electrodes are more stable than devices with more conventional, and more costly, Au and Ag electrodes. We demonstrate that a thin MoOx layer inhibits decomposition of the perovskite films under illumination in ambient laboratory conditions and greater improvements in device stability are achieved specifically with MoOx/Al electrodes. We investigated the role of the MoOx interlayer in the MoOx/Al electrodes by exploring the effect of relative humidity and the MoOx interlayer thickness on the perovskite solar cell stability.

14 SOLAR ENERGY↗

Status Report of the New Darmstadt Polarized Electron Injector

We present the status of the polarized injector for the superconducting Darmstadt electron linear accelerator S-DALINAC. An offline teststand of the source was built to test all components of the S-DALINAC polarized injector SPIN. The new electron source will deliver a 100 keV polarized beam and complement the present thermionic source operating at 250 kV. Results of the beam properties measurements will be introduced and an outlook on the upcoming installation of the new injector at the S-DALINAC will be given.

43 PARTICLE ACCELERATORS↗

Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

14 SOLAR ENERGY↗

Adverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015

Purpose: Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE) database, comparing these with non–radiation oncology devices. Methods and Materials: MAUDE data on RODs from 1991 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems) and 5 device problem categories (software, mechanical, electrical, user error, and dose delivery impact). Outcomes included whether the device was evaluated by the manufacturer, adverse event type, remedial action, problem code, device age, and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by the Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 4234 ROD and 4,985,698 other device adverse event reports. Adverse event reports increased over time, and events involving RODs peaked in 2011. Most ROD reports involved external beam therapy (50.8%), followed by brachytherapy (24.9%) and treatment planning systems (21.6%). The top problem types were software (30.4%), mechanical (20.9%), and user error (20.4%). RODs differed significantly from other devices in each outcome (P<.001). RODs were more likely to be evaluated by the manufacturer after an event (46.9% vs 33.0%) but less likely to be recalled (10.5% vs 37.9%) (P<.001). Device age and time since 510(k) approval were shorter among RODs (P<.001). Conclusions: Compared with other devices, RODs may experience adverse events sooner after manufacture and market approval. Close postmarket surveillance, improved software design, and manufacturer–user training may help mitigate these events.

07 ISOTOPE AND RADIATION SOURCES↗

DarkNESS Project Testing

This internship involved the design and assembly of a mechanical system for testing skipper-Charge Couple Devices (CCDs) for the DarkNESS project. Skipper-CCDs are highly-sensitive sensors with ultra-low readout noise that are deployed for direct detection of dark matter. DarkNESS is a CubeSat that aims to use skipper CCDs to search for dark matter decaying into X-rays. Currently, in the testing phase, the design process involved creating 3D models of mechanical adapters to operate a prototype space Multi Chip Module (sMCM) package in existing testing chambers in the CCD lab at Fermilab's IERC. The drawings were sent out to be machined, and while waiting to receive the finished adapters, we assembled a vacuum chamber for skipper-CCD testing and performed initial testing of a single CCD controlled by the space Low Threshold Acquisition (sLTA) board that will be employed on the CubeSat. The results showed that the testing conditions are optimal for data to start being taken and analyzed.

Akouedjinoude, Kodjo↗

Addressing Research and Development Gaps for Plasma-Material Interactions with Linear Plasma Devices

Plasma-material interactions in future fusion reactors have been identified as a knowledge gap to be dealt with before any next step device past ITER can be built. The challenges are manifold. They are related to power dissipation so that the heat fluxes to the plasma-facing components can be kept at technologically feasible levels; maximization of the lifetime of divertor plasma-facing components that allow for steadystate operation in a reactor to reach the neutron fluence required; the tritium inventory (storage) in the plasma-facing components, which can lead to potential safety concerns and reduction in the fuel efficiency; and it is related to the technology of the plasma-facing components itself, which should demonstrate structural integrity under the high temperatures and high neutron fluence. While the dissipation of power exhaust can and should be addressed in high power toroidal devices, the interaction of the plasma with the materials can be best addressed in dedicated linear devices due to their cost effectiveness and ability to address urgent research and development gaps more timely. However, new linear plasma devices are needed to investigate the PMI under fusion reactor conditions and test novel plasma-facing components. Existing linear devices are limited either in their flux, their reactor-relevant plasma transport regimes in front of the target, their fluence, or their ability to test material samples a priori exposed to high neutron fluence. The proposed Material Plasma Exposure eXperiment (MPEX) is meant to address those deficiencies and will be designed to fulfill the fusion reactor-relevant plasma parameters as well as the ability to expose a priori neutron activated materials to plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication and testing of a 4-node micro-pocket fission detector array for the Kansas State University TRIGA Mk. II research nuclear reactor

Advancements in nuclear reactor core modeling and computational capability have encouraged further development of in-core neutron sensors. Micro-Pocket Fission Detectors (MPFDs) have been fabricated and tested previously, but successful testing of these prior detectors was limited to single-node operation with specialized designs. Described in this work is a modular, four-node MPFD array fabricated and tested at Kansas State University (KSU). The four sensor nodes were equally spaced to span the length of the fuel-region of the KSU TRIGA Mk. II research nuclear reactor core. The encapsulated array was filled with argon gas, serving as an ionization medium in the small cavities of the MPFDs. The unified design improved device ruggedness and simplified construction over previous designs. A 0.315-in. (8-mm) penetration in the upper grid plate of the KSU TRIGA Mk. II research nuclear reactor was used to deploy the array between fuel elements in the core. The MPFD array was coupled to an electronic support system which has been developed to support pulse-mode operation. Neutron-induced pulses were observed on all four sensor channels. Stable device operation was confirmed by testing under steady-state reactor conditions. Each of the four sensors in the array responded to changes in reactor power between 10 kWth and full power (750 kWth). Reactor power transients were observed in real-time including positive transients with periods of 5, 15, and 30 s. Manual reactor power oscillations were observed in real-time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Microfabricated Devices and Ion Trapping Capabilities

Next generation ion traps will likely need to support tens if not hundreds of ions in order to achieve several logical qubits. As we scale to those sizes, the same problems we face now – rf dissipation, control I/O, and optical access – will only grow and become more complicated. While many of these challenges can potentially be solved with technology integration, independently researching the feasibility of that integration and other solutions may help reduce the time and risk in scaling up to larger traps, by testing on smaller less complex devices. We should also consider other fabrication techniques that may help scale to larger devices, such as: through-substrate-vias (TSVs), different metal coatings, exotic rf routing, on chip laser sources, or even a secondary macroscopic trap to reload ions from. To have these technologies ready for full scale integration when we need them, ion traps with some of these capabilities need to be produced now. Developing the rigorous fabrication methods for producing reliable traps takes time and experimentation. We propose developing larger ion traps and reliable integrated technology in conjunction to make both available faster.

36 MATERIALS SCIENCE↗

Evaluation of Light-Triggered Thyristors for Pulsed Power Applications

Lawrence Livermore National Laboratory has many needs for high reliability, high peak current, high di/dt switches. Solid-state switch technology offers the demonstrated advantage of reliability under a variety of conditions. Light-triggered switches operate with a reduced susceptibility to electromagnetic interference commonly found within pulsed power environments. Despite the advantages, commercially available solid-state switches are not typically designed for the often extreme pulsed power requirements. Testing was performed to bound the limits of devices for pulsed power applications beyond the manufacturers specified ratings. To test the applicability of recent commercial light-triggered solid-state designs, an adjustable high current switch test stand was assembled. Results from testing and subsequent selected implementations are presented.

42 ENGINEERING↗