Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A comparative study on the frequency effects of the electrical characteristics of the pulsed dielectric barrier discharge in He/O{sub 2} and in Ar/O{sub 2} at atmospheric pressure

In this work, a comparative study on the frequency effects of the electrical characteristics of the pulsed dielectric barrier discharges in He/O{sub 2} and in Ar/O{sub 2} at atmospheric pressure has been performed by means of the numerical simulation based on a 1-D fluid model at frequencies below 100 kHz. The frequency dependences of the characteristic quantities of the discharges in the two gases have been systematically calculated and analyzed under the oxygen concentrations below 2%. The characteristic quantities include the discharge current density, the averaged electron density, the electric field, and the averaged electron temperature. Especially, the frequency effects on the averaged particle densities of the reactive species have also been calculated. This work gives the following significant results. For the two gases, there are two bipolar discharges in one period of applied voltage pulse under the considered frequency range and oxygen concentrations, as occurred in the pure noble gases. The frequency affects the two discharges in He/O{sub 2}, but in Ar/O{sub 2}, it induces a strong effect only on the first discharge. For the first discharge in each gas, there is a characteristic frequency at which the characteristic quantities reach their respective minimum, and this frequency appears earlier for Ar/O{sub 2}. For the second discharge in Ar/O{sub 2}, the averaged electron density presents a slight variation with the frequency. In addition, the discharge in Ar/O{sub 2} is strong and the averaged electron temperature is low, compared to those in He/O{sub 2.} The total averaged particle density of the reactive species in Ar/O{sub 2} is larger than those in He/O{sub 2} by about one order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coaxial Cables for Martian Extreme Temperature Environments

Work was conducted to validate the use of the rover external flexible coaxial cabling for space under the extreme environments to be encountered during the Mars Science Laboratory (MSL) mission. The antennas must survive all ground operations plus the nominal 670-Martian-day mission that includes summer and winter seasons of the Mars environment. Successful development of processes established coaxial cable hardware fatigue limits, which were well beyond the expected in-flight exposures. In keeping with traditional qualification philosophy, this was accomplished by subjecting flight-representative coaxial cables to temperature cycling of the same depth as expected in-flight, but for three times the expected number of in-flight thermal cycles. Insertion loss and return loss tests were performed on the coaxial cables during the thermal chamber breaks. A vector network analyzer was calibrated and operated over the operational frequency range 7.145 to 8.450 GHz. Even though some of the exposed cables function only at UHF frequencies (approximately 400 MHz), the testing was more sensitive, and extending the test range down to 400 MHz would have cost frequency resolution. The Gore flexible coaxial cables, which were the subject of these tests, proved to be robust and displayed no sign of degradation due to the 3X exposure to the punishing Mars surface operations cycles.

Ramesham, Rajeshuni↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent anisotropic magnetoresistance and spin-torque-driven vortex dynamics in a single microdisk

Spin-orbit-torque-driven dynamics have recently gained interest in the field of magnetism due to the reduced requirement of current densities and an increase in efficiency, as well as the ease of implementation of different devices and materials. From a practical point of view, the low-frequency dynamics below 1GHz is particularly interesting since dynamics associated with magnetic domains lie in this frequency range. While spin-torque excitation of high-frequency modes has been extensively studied, the intermediate low-frequency dynamics have received less attention, although spin torques could potentially be used for both manipulation of the spin texture and the excitation of dynamics. In this paper, we demonstrate that it is possible to drive magnetic vortex dynamics in a single microdisk by spin-Hall torque at varying temperatures and relate the results to transport properties. We find that the gyrotropic mode of the core couples to the low-frequency microwave signal and produces a measurable voltage. The dynamic measurements are in agreement with magnetic transport measurements and are supported by micromagnetic simulations. Our results open the door for integrating magnetic vortex devices in spintronic applications.

36 MATERIALS SCIENCE↗

Spectral function of the Holstein polaron at finite temperature

Here we compute the Holstein polaron spectral function on a one-dimensional ring using the finite-temperature T Lanczos method. With increasing T additional features in the spectral function emerge even at temperatures below the phonon frequency. We observe a substantial spread of the spectral weight towards lower frequencies and the broadening of the quasiparticle (QP) peak. In the weak-coupling regime the QP peak merges with the continuum in the high-T limit. In the strong-coupling regime the main features of the low-T spectral function remain detectable up to the highest T used in our calculations. The effective polaron mass shows a nonmonotonic behavior as a function of T at small phonon frequency but increases with T at larger frequencies. The self-energy remains k independent even at elevated T in the frequency range corresponding to the polaron band, while at higher frequencies it develops a distinguishable k dependence. Analytical expressions for the first few frequency moments are derived, and they agree well with those extracted from numerical calculations in a wide-T regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stimulated Emission of Signal Photons from Dark Matter Waves

The manipulation of quantum states of light has resulted in significant advancements in both dark matter searches and gravitational wave detectors. Current dark matter searches operating in the microwave frequency range use nearly quantum-limited amplifiers. Future high frequency searches will use photon counting techniques to evade the standard quantum limit. We present a signal enhancement technique that utilizes a superconducting qubit to prepare a superconducting microwave cavity in a nonclassical Fock state and stimulate the emission of a photon from a dark matter wave. By initializing the cavity in an | n = 4 ⟩ Fock state, we demonstrate a quantum enhancement technique that increases the signal photon rate and hence also the dark matter scan rate each by a factor of 2.78. Using this technique, we conduct a dark photon search in a band around 5.965 GHz ( 24.67 μ eV ), where the kinetic mixing angle ε ≥ 4.35 × 10 − 13 is excluded at the 90% confidence level. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simcenter TestLab Error in uploading reference profiles

Our team exports data from Matlab to a Simcenter TestLab formatted .mat file. The .mat file is then uploaded as a reference profile for Environmental Random Control vibration testing. Operations are applied to the data before export that introduce floating point errors. We are experiencing errors uploading the generated reference profiles if the frequency values have a certain level of floating point error (1 Hz vs 1.000000000000001 Hz). I generated some test cases of reference profiles that were giving us trouble, and outlined the errors we were seeing. Two different errors, depending on how the control frequency range is defined. Error is fixed by copy/pasting the frequency column in the Profile Editor.

97 MATHEMATICS AND COMPUTING↗

The millimeter and submillimeter laboratory spectrum of methyl formate in its ground symmetric torsional state

Over 200 rotational lines of methyl formate in its ground (v sub t = 0), symmetric (A) torsional state have been measured in the frequency range 140-550 GHz. Analysis of these and lower frequency transitions permits accurate prediction (below 0.1 MHz) of over 10,000 transitions at frequencies below 600 GHz with angular momentum J lower than 50. The measured spectral lines have permitted identification of over 100 new methyl formate lines in Orion.

Plummer, G. M.↗

Measured and calculated acoustic attenuation rates of tuned resonator arrays for two surface impedance distribution models with flow

An experiment was performed to validate two analytical models for predicting low frequency attenuation of duct liner configurations built from an array of seven resonators that could be individually tuned via adjustable cavity depths. These analytical models had previously been developed for high frequency aero-engine inlet duct liner design. In the low frequency application, the liner surface impedance distribution is unavoidably spatially varying by virtue of available fabrication techniques. The characteristic length of this spatial variation may be a significant fraction of the acoustic wavelength. Comparison of measured and predicted attenuation rates and transmission losses for both modal decomposition and finite element propagation models were in good to excellent agreement for a test frequency range that included the first and second cavity resonance frequencies. This was true for either of two surface impedance distribution modeling procedures used to simplify the impedance boundary conditions. In the presence of mean flow, measurements revealed a fine scale structure of acoustic hot spots in the attenuation and phase profiles. These details were accurately predicted by the finite element model. Since no impedance changes due to mean flow were assumed, it is concluded that this fine scale structure was due to convective effects of the mean flow interacting with the surface impedance nonuniformities.

Parrott, Tony L.↗

Proton beam generation of whistler waves in the earth's foreshock

It is shown that proton beams, often observed upstream of the earth's bow shock and associated with the generation of low-frequency hydromagnetic fluctuations, are also capable of generating whistler waves. The waves can be excited by an instability driven by two-temperature streaming Maxwellian proton distributions which have T (perpendicular)/T(parallel) much greater than 1. It can also be excited by gyrating proton beam distributions. These distributions generate whistler waves with frequencies ranging from 10 to 100 times the proton cyclotron frequency (in the solar wind reference frame) and provide another mechanism for generating the '1-Hz' waves often seen in the earth's foreshock.

Wong, H. K.↗

Crossflow-vortex instability and transition on a 45 deg swept wing

A crossflow vortex experiment on a 45 deg swept wing is currently being conducted in the Arizona State University Unsteady Wind Tunnel. The experimental apparatus is designed to produce crossflow-dominated transition by simulating infinite swept wing flow using contoured end liners in a closed throat wind tunnel. Stationary fixed-wavelength crossflow vortices are observed at several chord Reynolds numbers. The vortex wavelength which is fixed for a given Reynolds number varies with Reynolds number approximately as predicted by linear stability theory, but with the predicted wavelengths about 30 percent larger than the observed wavelengths. Travelling waves are observed both in the frequency range predicted by linear stability theory and at higher frequencies. These higher frequency waves may be harmonics of the primary crossflow waves generated by a nonlinear parametric resonance phenomena.

Dagenhart, J. Ray↗

Control of Jovian Radio Emission by Ganymede

Galileo has been in orbit around Jupiter since December 1995. We present the results of a survey of the data for the frequency range 3.2 MHz to 5.6 MHz, the low-frequency decametric (DAM) emissions. While the control of a portion of the radio emission by the moon Io is well-known, we report that a small but significant portion of low-frequency DAM emission is seen to be correlated with the orbital phase of Ganymede. This result is in agreement with other recent results indicating a significant interaction of the magnetosphere of Ganymede with that of Jupiter.

Menietti, J. D.↗

Fluidization and drying of biomass particles in a vibrating fluidized bed with pulsed gas flow

Fluidization of biomass particles in the absence of inert bed materials has been tested in a pulsed fluidized bed with vibration, with the pulsation frequency ranging from 033 to 6.67 Hz. Intermittent fluidization at 033 Hz and apparently 'normal' fluidization at 6.67 Hz with regular bubble patterns were observed. Pulsation has proven to be effective in overcoming the bridging of irregular biomass particles induced by strong inter-particle forces. The vibration is only effective when the pulsation is inadequate, either at too low a frequency or too low in amplitude. We dried biomass in order to quantify the effectiveness of gas pulsation for fluidized bed dryers and torrefiers in terms of gas-solid contact efficiency and heat and mass transfer rates. Furthermore, the effects of gas flow rate, bed temperature, pulsation frequency and vibration intensity on drying performance have been systematically investigated. While higher temperature and gas flow rate are favored in drying, there exists an optimal range of pulsation frequency between 0.75 Hz and 1.5 Hz where gas-solid contact is enhanced in both the constant rate drying and falling rate drying periods.

09 BIOMASS FUELS↗

Nuclear magnetic resonance study of Li and H diffusion in the high-temperature solid phase of LiBH{sub 4}

In order to study the atomic jump motions in the high-temperature solid phase of LiBH{sub 4}, we have measured the {sup 1}H and {sup 11}B nuclear magnetic resonance (NMR) spectra and the {sup 1}H, {sup 7}Li and {sup 11}B spin-lattice relaxation rates in this compound over the resonance frequency range of 14-34.4 MHz. In the temperature range 384-500 K, all the spin-lattice relaxation data are satisfactorily described in terms of a thermally activated jump motion of Li ions with the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV. The observed frequency dependences of the spin-lattice relaxation rates in this temperature range exclude a presence of any distributions of the Li jump rate or any other jump processes on the frequency scale of 10{sup 7}-10{sup 10} s{sup -1}. The strong narrowing of the {sup 1}H and {sup 11}B NMR lines above 440 K is consistent with the onset of diffusive motion of the BH{sub 4} tetrahedra. - Graphical abstract: The measured spin-lattice relaxation rates of {sup 1}H (a), {sup 7}Li (b) and {sup 11}B (c) as functions of the inverse temperature for the high-temperature solid phase of LiBH{sub 4}. The curves show the simultaneous Bloembergen-Purcell-Pound fits to the data with the fixed parameters of Li diffusion (the pre-exponential factor tau{sub 0}=1.1x10{sup -15} s and the activation energy E{sub a}=0.56 eV). This plot indicates that all the relaxation data for different nuclei and at different resonance frequencies are governed by a single Li jump process. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural and transport properties of NdCrO{sub 3} nanoceramics

Reitveld refinement of the room temperature powder X-ray diffraction profile of NdCrO{sub 3} (NCO) nanoceramics synthesized by sol-gel processing shows orthorhombic Pnma (D{sub 2h}{sup 16}) space group symmetry. The refined lattice parameters are a = 5.482(3) A, b = 7.689(4) A and c = 5.416(3) A. Transmission electron microscopy (TEM) of NCO shows that the average particle size is around 70 nm. The electrical transport property of NCO is investigated by both conductivity and electric modulus formalism. The electrical data is taken by a LCR meter in a temperature range from 303 K to 573 K and in a frequency range from 42 Hz to 1.1 MHz. The ac conductivity follows a power law. The Cole-Cole plot of impedance at 303 K shows grain effect.

36 MATERIALS SCIENCE↗

600-GHz Electronically Tunable Vector Measurement System

A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

Dengler, Robert↗