Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Structural and luminescence studies of Ho{sup 3+}-doped zinc-aluminium-sodium-phosphate (ZANP) glasses

Trivalent holmium doped zinc-aluminium-sodium-phosphate (ZANP) glasses were prepared by conventional melt-quenching technique and characterized for their structural and luminescence properties. The amorphous nature, elemental analysis and thermal stability of the glasses were studied by using X-ray diffraction, energy dispersive spectrum and differential scanning calorimetry analysis, respectively. The absorption and fluorescence spectra have been recorded at room temperature. Based on the absorption spectra, the Judd-Ofelt parameters and radiative parameters such as spontaneous transition probabilities (A{sub R}), branching ratios (β{sub R}), radiative lifetimes (τ{sub R}) were calculated and discussed. From the emission spectra emission peak positions (λ{sub P}), effective bandwidths (Δλ{sub eff}) and stimulated emission cross-sections (σ{sub P}) were calculated for the observed emission transitions,{sup 5}S{sub 2} ({sup 5}F{sub 4}→{sup 5}I{sub 8}) and {sup 5}F{sub 5}→{sup 5}I{sub 8} in all the glass samples. The stimulated emission cross-section is higher for ZANPHo10 glass matrix and so it may be useful for laser excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conformational changes in matrix-isolated 6-methoxyindole: Effects of the thermal and infrared light excitations

Conformational changes induced thermally or upon infrared excitation of matrix-isolated 6-methoxyindole were investigated. Narrowband near-infrared excitation of the first overtone of the N–H stretching vibration of each one of the two identified conformers is found to induce a selective large-scale conversion of the pumped conformer into the other one. This easily controllable bidirectional process consists in the intramolecular reorientation of the methoxy group and allowed a full assignment of the infrared spectra of the two conformers. Matrices with different conformational compositions prepared by narrow-band irradiations were subsequently used to investigate the effects of both thermal and broadband infrared excitations on the conformational mixtures. Particular attention is given to the influence of the matrix medium (Ar vs. Xe) and conformational effects of exposition of the sample to the spectrometer light source during the measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a scanning time of flight microscope and its application to the study of charge transport in phase separated structured organic semiconductors

We describe a tool for studying the two-dimensional spatial variation in electronic properties of organic semiconductors: the scanning time-of-flight microscope (STOFm). The STOFm simultaneously measures the transmittance of polarized light and time-of-flight current transients with a pixel size <30 μm, making it especially valuable for studies of the correlations of structure with charge generation and transport in liquid crystalline organic semiconductors (LC OSCs). Adapting a previously developed photopolymerization technique, we characterize the instrument using patterned samples of a LC OSC bounded by a non-semiconducting polymer matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated Markov Chain Monte Carlo (MCMC) analysis of primordial non-Gaussianity (f{sub NL}) in the recent CMB data

We have made a Markov Chain Monte Carlo (MCMC) analysis of primordial non-Gaussianity (f{sub NL}) using the WMAP bispectrum and power spectrum. In our analysis, we have simultaneously constrained f{sub NL} and cosmological parameters so that the uncertainties of cosmological parameters can properly propagate into the f{sub NL} estimation. Investigating the parameter likelihoods deduced from MCMC samples, we find slight deviation from Gaussian shape, which makes a Fisher matrix estimation less accurate. Therefore, we have estimated the confidence interval of f{sub NL} by exploring the parameter likelihood without using the Fisher matrix. We find that the best-fit values of our analysis make a good agreement with other results, but the confidence interval is slightly different.

79 ASTRONOMY AND ASTROPHYSICS↗

BAO from angular clustering: optimization and mitigation of theoretical systematics

Here, we study the methodology and potential theoretical systematics of measuring Baryon Acoustic Oscillations (BAO) using the angular correlation functions in tomographic bins. We calibrate and optimize the pipeline for the Dark Energy Survey Year 1 dataset using 1800 mocks. We compare the BAO fitting results obtained with three estimators: the Maximum Likelihood Estimator (MLE), Profile Likelihood, and Markov Chain Monte Carlo. The fit results from the MLE are the least biased and their derived 1-$\sigma$ error bar are closest to the Gaussian distribution value after removing the extreme mocks with non-detected BAO signal. We show that incorrect assumptions in constructing the template, such as mismatches from the cosmology of the mocks or the underlying photo-$z$ errors, can lead to BAO angular shifts. We find that MLE is the method that best traces this systematic biases, allowing to recover the true angular distance values. In a real survey analysis, it may happen that the final data sample properties are slightly different from those of the mock catalog. We show that the effect on the mock covariance due to the sample differences can be corrected with the help of the Gaussian covariance matrix or more effectively using the eigenmode expansion of the mock covariance. In the eigenmode expansion, the eigenmodes are provided by some proxy covariance matrix. The eigenmode expansion is significantly less susceptible to statistical fluctuations relative to the direct measurements of the covariance matrix because of the number of free parameters is substantially reduced

79 ASTRONOMY AND ASTROPHYSICS↗

Vapor Sensing Using Conjugated Molecule‐Linked Au Nanoparticles in a Silica Matrix

Cross‐linked assemblies of nanoparticles are of great value as chemiresistor‐type sensors. Herein, we report a simple method to fabricate a chemiresistor‐type sensor that minimizes the swelling transduction mechanism while optimizing the change in dielectric response. Sensors prepared with this methodology showed enhanced chemoselectivity for phosphonates which are useful surrogates for chemical weapons. Chemoselective sensors were fabricated using an aqueous solution of gold nanoparticles that were then cross‐linked in the presence of the silica precursor, tetraethyl orthosilicate with the α ‐, ω ‐dithiolate (which is derived from the in situ deprotection of 1,4‐di(Phenylethynyl‐4 ′ ,4 ″ ‐diacetylthio)‐benzene ( 1 ) with wet triethylamine). The cross‐linked nanoparticles and silica matrix were drop coated onto interdigitated electrodes having 8 μ m spacing. Samples were exposed to a series of analytes including dimethyl methylphosphonate (DMMP), octane, and toluene. A limit of detection was obtained for each analyte. Sensors assembled in this fashion were more sensitive to dimethyl methylphosphonate than to octane by a factor of 1000.

Dirk, Shawn M.↗

Preparation of Nuclear Data Libraries for Web Release [Slides] and Tutorial for Generating Correlated Random Samples and Propagation of Uncertainty [Slides]

The first presentation discuses moving distribution of nuclear data to an online platform which allows ore frequent nuclear data updates, greater ease of acquiring nuclear data, and user flexibility in what nuclear data to download. The second presentation illustrates uncertainties without correlation, uncertainties without correlation with negative samples, uncertainties with correlation, uncertainties with a χ-like constraint, uncertainties with a Σ tot -like constraint, sampling using different distributions, and dealing with negative eigenvalues in a covariance matrix.

42 ENGINEERING↗

Task 2 INL Updated Test Matrix and Updated Milestones

Test plan for FY20 work on ASNF work. Current Status and Proposed Test Matrix: Corrosion testing has been delayed due to iron contamination of corroded samples – investigations as to the source of this is underway and plans for mitigation for the next round in place. Completed pristine Al1100 coupon irradiations under argon and nitrogen atmospheres of various relative humidities were undertaken and reported in December 2019. This work contributed to Milestone 2.6 and Milestone 2.8. The agreed total absorbed doses for this work were 250, 500, 750, and 1000 kGy. However, the new proposed work to be undertaken at SRNL includes total doses of 50 and 100 kGy. Additional total gamma doses will also include pre-corroded samples, so thorough comparisons can be made. Samples in helium head spaces will be prioritized.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structures of immiscible Al-In alloys solidified under microgravity conditions

Four samples of the immiscible Al-In system having monotectic and hypermonotectic compositions were solidified under microgravity during the NASA-SPAR IX flight of January 20th, 1981. The experimental thermal and physico-chemical conditions actually achieved have been analysed. Radiographic and metallographic observations of the samples show a non-regular dispersed primary phase inside the monotectic matrix. These observations are commented on the basis of capillarity and solidification aspects.

Potard, C.↗

Sm-Nd age of the Fiskenaesset Anorthosite Complex, West Greenland

A Sm-Nd isotopic study on samples from the Fiskenaesset Anorthosite Complex in West Greenland was conducted to estimate the age of crystallization of the complex. A five-point isochron, including data for whole-rock samples of anorthosite, metagabbro, metaperidotite, and separates of calcic plagioclase and mafic matrix from a coarse megacrystic leucogabbro, corresponds to an age of 2.86 + or - 0.05 Ga, with initial sigma(Nd) of +2.9 + or - 0.4. This implies a relatively short time interval, on the order of 70 Ma, during which anorthosite formation, tonalite emplacement, and high-grade metamorphism took place.

Ashwal, Lewis D.↗

Computational aspects of chemically reacting flows

An implicit, time-dependent approach is taken to solve the inviscid conservative equations in a vertex-based finite-volume formulation. The convective fluxes are estimated by a modified Riemann solver, and higher-order accuracy is obtained by means of the MUSCL. Implicit techniques are adopted to deal with the equation stiffness as a result of the clustered grid and chemical source term. The real-gas Roe matrix and the ADI and LU schemes have been tested on the sample problems: hypersonic flow over blunt configurations, such as the forebody of a double ellipse, and the near wake of a conic aerobrake. Temperature distribution and standoff distance are validated against the shock-fitting, central-differencing results. Equilibrium temperature may be recovered by artificially increasing the chemical rates at the wall. The present method satisfactorily resolves the flow structure, including the strong expansion behind the flat base. The relative merits and performance of the real-gas TVD and implicit schemes are discussed briefly.

Li, C. P.↗

Processing and testing of high toughness silicon nitride ceramics

High toughness silicon nitride ceramics were processed with the addition of small quantities of beta-Si3N4 whiskers in a commercially available alpha-Si3N4 powder. These whiskers grew preferentially during sintering resulting in large, elongated beta-grains, which acted to toughen the matrix by crack deflection and grain pullout. The fracture toughness of these samples seeded with beta-Si3N4 whiskers ranged from 8.7 to 9.5 MPa m(exp 0.5) depending on the sintering additives.

Tikare, Veena↗

Surface characterization of LDEF materials

The NASA Long Duration Exposure Facility (LDEF), a passive experimental satellite, was placed into low-Earth orbit by the Shuttle Challenger in Apr. 1984. The LDEF spent an unprecedented 69 months in space. The flight and recovery of the LDEF provided a wealth of information on the longterm space environmental effects of a variety of materials exposed to the low-Earth orbit environment. Surface characterization of LDEF materials included polymers, composites, thermal control paints, and aluminum. X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), scanning electron microscopy (SEM), and contact angle analysis were used to document changes in both the surface composition and surface chemistry of these materials. Detailed XPS analysis of the polymer systems, such as Kapton, polyimide polysiloxane copolymers, and fluorinated ethylene propylene thermal blankets on the backside of the LDEF revealed significant changes in both the surface composition and surface chemistry as a result of exposure to the low-Earth orbit environment. Polymer systems such as Kapton, polyimide polysiloxane copolymers, and polysulfone showed a common trend of decreasing carbon content and increasing oxygen content with respect to the control sample. Carbon 1s curve fit XPS analysis of the composite samples, in conjunction with SEM photomicrographs, revealed significant ablation of the polymer matrix resin to expose the carbon fibers of the composite during exposure to the space environment. Surface characterization of anodized aluminum tray clamps, which were located at regular intervals over the entire LDEF frame, provided the first results to evaluate the extent of contamination with respect to position on the LDEF. The XPS results clearly showed that the amount and state of both silicon and fluorine contamination were directly dependent upon the position of the tray clamp on the LDEF.

Wightman, J. P.↗

Liquidus Temperatures and Solidification Behavior in the Copper-Niobium System

The copper-niobium phase diagram has been under active debate; thus, a corroboratory experimental study is needed. In this investigation, the melts of Cu-Nb alloys at compositions ranging from 5 lo 86 wt% Nb were processed in different environments and solidified at relatively low rates of 50-75 C/s to determine liquidus temperatures and to study solidification behavior. For all samples processed under very clean conditions, only Nb dendrites in a Cu matrix were observed; while in the presents of oxygen impurities, the alloys containing 5-35 wt% Nb exhibited microstructure of Nb-rich spheroids and Nb dendrites in the Cu matrix. The results obtained from clean conditions are in fair agreement with the Cu-Nb phase diagram having an S-shaped, near-horizontal appearances of the liquidus. The formation of Nb-rich droplets at slow cooling rates is discussed in terms of a stable liquid miscibility gap induced by oxygen.

Li, D.↗

Liquidus Temperatures and Solidification Behavior in the Copper-Niobium System

The copper-niobium phase diagram has been under active debate; thus, a corroboratory experimental study is needed. In this investigation, the melts of Cu-Nb alloys at compositions ranging from 5 to 86 wt pct Nb were processed in different environments and solidified at relatively low cooling rates of 50 to 75 C/s to determine liquidus temperatures and to study solidification behavior. For all samples processed under very clean conditions, only Nb dendrites in a Cu matrix were observed; while in the presence of oxygen impurities the alloys containing 5 to 35 wt pct Nb exhibited microstructure of Nb-rich spheroids and Nb dendrites in the Cu matrix. The results obtained from clean conditions are in fair agreement with the Cu-Nb phase diagram having an S-shaped, near-horizontal appearance of the liquidus. The formation of Nb- rich droplets at slow cooling rates is discussed in terms of a stable liquid miscibility gap induced by oxygen.

Li, D.↗

Laboratory Infrared Spectra of Polycyclic Aromatic Nitrogen Heterocycles: Quinoline, and Phenanthridine in Solid Argon and H2O

Polycyclic aromatic hydrocarbons (PAHs) are common throughout the universe. Their detection and identification are based on telescopic infrared (IR) spectra compared with laboratory data. Polycyclic Aromatic Nitrogen Heterocycles (PANHs) are heterocyclic aromatics i.e., PAHs with carbon atoms replaced by a nitrogen atom. These molecules should be present in the interstellar medium, but have received relatively little attention. We present mid-IR spectra of two PANHs, quinoline (C9H7N), and phenanthridine (C13H9N) isolated in solid argon and frozen in solid H2O at 12 K, conditions yielding data directly comparable to astronomical observations. In contrast to simple PAHs, that do not interact strongly with solid H2O, the nitrogen atoms in PANHs are potentially capable of hydrogen bonding with H2O. Whereas the IR spectrum of phenanthridine in H2O is similar to that of the same compound isolated in an argon matrix, quinoline absorptions shift up to 16 cm(sup -1) (0.072 mm) between argon and H2O. Thus, astronomers will not always be able to rely on IR band positions of matrix isolated PANHs to correctly interpret the absorptions of PANHs frozen in H2O ice grains. Furthermore, our data suggest that relative band areas also vary, so determining column densities to better than a factor of 3 will require knowledge of the matrix in which the PANH is embedded and laboratory studies of relevant samples.

Bernstein, M. P.↗

The Mid-Infrared Absorption Spectra of Neutral PAHs in Dense Interstellar Clouds

Polycyclic aromatic hydrocarbons (PAHs) are common throughout the universe and are expected to be present in dense interstellar clouds. In these environments, some P.4Hs may be present in the gas phase, but most should be frozen into ice mantles or adsorbed onto dust grains and their spectral features are expected to be seen in absorption. Here we extend our previous work on the infrared spectral properties of the small PAH naphthalene (C10H8) in several media to include the full mid-infrared laboratory spectra of 11 other PAHs and related aromatic species frozen in H2O ices. These include the molecules 1,2-dihydronaphthalene, anthracene, 9,1O-dihydroanthracene, phenanthrene, pyrene, benzo[e]pyrene, perylene, benzo(k)fluoranthene, pentacene, benzo[ghi]perylene, and coronene. These results demonstrate that PAHs and related molecules, as a class, show the same spectral behaviors as naphthalene when incorporated into H2O-rich matrices. When compared to the spectra of these same molecules isolated in inert matrices (e.g., Ar or N2), the absorption bands produced when they are frozen in H2O matrices are broader (factors of 3-10), show small position shifts in either direction (usually < 4/cm, always < 10/cm), and show variable changes in relative band strengths (typically factors of 1-3). There is no evidence of systematic increases or decreases in the absolute strengths of the bands of these molecules when they are incorporated in H2O matrices. In H2O-rich ices, their absorption bands are relatively insensitive to concentration over the range of 10 < H2O/PAH < 200): The absorption bands of these molecules are also insensitive to temperature over the 10 K < T < 125 K range, although the spectra can show dramatic changes as the ices are warmed through the temperature range in which amorphous H2O ice converts to its cubic and hexagonal crystalline forms (T > 125 Kj. Given the small observed band shifts cause by H2O, the current database of spectra from Ar matrix-isolated neutral PAHs and related molecules should be useful for the search for these species in dense clouds on the basis of observed absorption band positions. Furthermore, these data permit determination of column densities to better than a factor of 3 for PAHs in dense clouds. Column density determination of detected aromatics to better than a factor of 3 will, however, require good knowledge about the nature of the matrix in which the PAH is embedded and laboratory studies of relevant samples.

Bernstein, M. P.↗