Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

A High-resolution Regional Wave Resource Characterization For The U.S. West Coast

Objectives/Scope: Wave resource characterization is a critical step for wave energy converter deployment in the coastal ocean and relies on long-term, high-resolution wave datasets. This study presents a detailed modeling study of the wave resource along the U.S. West Coast (Washington, Oregon, and California), a coastal region that was identified with high wave energy potential in earlier studies. Methods, Procedures, Process: The wave hindcast covers a 32-year period from 1979 to 2010 and is based on a multi-resolution, unstructured-grid SWAN model framework. Model configuration closely follows and meets the requirements recommended by the International Electrotechnical Commission Technical Specification (IEC TS) for wave energy resource assessment and characterization (Class 2 - feasibility study). The model domain covers the entire U.S. Exclusive Economic Zone (EEZ) in the West Coast and has a spatial resolution varying from ~300 m in the nearshore region (20 km from the shoreline) to ~2500 m within the EEZ and ~5000 m at the open boundary, which extends beyond the EEZ. The model was forced by hourly 2-D wave spectra produced by a two-way nested WaveWatch III model, which covers the global ocean domain and the broader U.S. West Coast region domain with spatial resolutions of 0.5 degree and 10 arc-minutes, respectively. Both wave models are forced by hourly, 0.5-degree wind forcing obtained from NCEP’s Climate Forecast System Reanalysis (CFSR) product. Results, Observations, Conclusions: The standard model output for the SWAN model includes 3-hourly output for the six IEC wave resource parameters (e.g., omnidirectional wave power) at each grid point and hourly 2-D spectra at more than 50 NDBC buoys. Extensive model validation was achieved by comparing the six model-predicted IEC parameters with those derived from field observations at representative NDBC buoys. The error statistics indicated the model’s satisfactory performance. Further analyses were conducted to systematically evaluate the temporal and spatial distributions of wave energy potential and wave climate along the U.S. West Coast. Results suggest that Washington and Oregon coasts have similar nearshore wave resource, which is significantly higher than resources in Southern California. Strong seasonal variations are also observed, e.g., high wave energy tends to occur in the winter months. In summary, this study produced the first high-resolution, comprehensive dataset on wave energy distribution along the U.S. West Coast. Novel/Additive Information: The results are being used by the National Renewable Energy Laboratory to update the MHK Atlas, which was originally derived from NOAA’s 4-arc-minute WaveWatch III model output. In addition, the monthly averaged wave energy climatology dataset can be readily shared to support a variety of research and application efforts within the EEZ of the U.S. West Coast.

Wang, Taiping↗

High-Resolution Infrared Spectroscopy with Synchrotron Sources

Most applications of synchrotron radiation lie in the ultraviolet and X-ray region, but it also serves as a valuable continuum source of infrared (IR) light which is much brighter (i.e. more highly directional) than that from normal thermal sources. The synchrotron brightness advantage was originally exploited for high spatial resolution spectroscopy of condensed-phase samples. But it is also valuable for high spectral resolution of gas-phase samples, particularly in the difficult far-IR (terahertz) range (1/{lambda} {approx} 10-1000 cm{sup -1}). Essentially, the synchrotron replaces the usual thermal source in a Fourier transform IR spectrometer, giving a increase of up to two (or even more) orders of magnitude in signal at very high-resolution. Following up on pioneering work in Sweden (MAX-lab) and France (LURE), a number of new facilities have recently been constructed for high-resolution gas-phase IR spectroscopy. In the present paper, this new field is reviewed. The advantages and difficulties associated with synchrotron IR spectroscopy are outlined, current and new facilities are described, and past, present, and future spectroscopic results are summarized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time and position resolution of the scintillator strips for a muon system at future colliders

In this study, prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution energy analyzer for broad ion beam characterization

Characterization of the ion energy distribution function (IEDF) of low energy high current density ion beams by conventional retarding field and deflection type energy analyzers is limited due to finite ion beam emittance and beam space charge spreading inside the analyzer. These deficiencies are, to a large extent, overcome with the recent development of the variable-focusing retarding field energy analyzer (RFEA), which has a cylindrical focusing electrode preceding the planar retarding grid. The principal concept of this analyzer is conversion of a divergent charged particle beam into a quasiparallel beam before analyzing it by the planar retarding field. This allows analysis of the beam particle total kinetic energy distribution with greatly improved energy resolution. Whereas this concept was first applied to analyze 5-10 keV pulsed electron beams, the present authors have adapted it to analyze the energy distribution of a low energy ({<=}1 KeV) broad ion beam. In this paper we describe the RFEA design, which was modified from the original, mainly as required by the specifics of broad ion beam energy analysis, and the device experimental characterization and modeling results. Among the modifications, an orifice electrode placed in front of the RFEA provides better spatial resolution of the broad ion beam ion optics emission region and reduces the beam plasma density in the vicinity of analyzer entry. An electron repeller grid placed in front of the RFEA collector was found critical for suppressing secondary electrons, both those incoming to the collector and those released from its surface, and improved energy spectrum measurement repeatability and accuracy. The use of finer mesh single- and double-grid retarding structures reduces the retarding grid lens effect and improves the analyzer energy resolution and accuracy of the measured spectrum mean energy. However, additional analyzer component and configuration improvements did not further change the analyzed IEDF shape or mean energy value. This led us to conclude that the optimized analyzer construction provides an energy resolution considerably narrower than the investigated ion beam energy spectrum full width at half maximum, and the derived energy spectrum is an objective and accurate representation of the analyzed broad ion beam energy distribution characteristics. A quantitative study of the focusing voltage and retarding grid field effects based on the experimental data and modeling results have supported this conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study of high-resolution coherent diffraction microscopy using synchrotron x rays focused by Kirkpatrick-Baez mirrors

High-flux coherent x rays are necessary for the improvement of the spatial resolution in coherent x-ray diffraction microscopy (CXDM). In this study, high-resolution CXDM using Kirkpatrick-Baez (KB) mirrors is proposed, and the mirrors are designed for experiments of the transmission scheme at SPring-8. Both the photon density and spatial coherence of synchrotron x rays focused by the KB mirrors are investigated by wave optical simulation. The KB mirrors can produce nearly diffraction-limited two-dimensional focusing x rays of approx1 mum in size at 8 keV. When the sample size is less than approx1 mum, the sample can be illuminated with full coherent x rays by adjusting the cross-slit size set between the source and the mirrors. From the estimated photon density at the sample position, the feasibility of CXDM with a sub-1-nm spatial resolution is suggested. The present ultraprecise figuring process enables us to fabricate mirrors for carrying out high-resolution CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

36 MATERIALS SCIENCE↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HIGH-RESOLUTION SURVEY OF H I ABSORPTION TOWARD THE CENTRAL 200 pc OF THE GALACTIC CENTER

We present an H I absorption survey of the central 250 pc of the Galaxy. Very Large Array observations were made at 21 cm in the DnC and CnB configurations and have a resolution of {approx}15'' (0.6 pc at the Galactic center (GC) distance) and a velocity resolution of {approx}2.5 km s{sup -1}. This study provides H I data with high spatial resolution, comparable with the many high-resolution observations which have been made of GC sources over the past 10 years. Here we present an overview of the H I absorption toward {approx}40 well-known continuum sources and a detailed comparison of the ionized, atomic, and molecular components of the interstellar medium for the Sgr B, Radio Arc, and Sgr C regions. In these well-known regions, the atomic gas appears to be closely correlated in both velocity and distribution to the ionized and molecular gas, indicating that it resides in photodissociation regions related to the H II regions in the GC. Toward the majority of the radio continuum sources, H I absorption by the 3 kpc arm is detected, constraining these sources to lie beyond a 5 kpc distance in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Areal density and spatial resolution of high energy electron radiography

Ultrafast imaging tools are of great importance for determining the dynamic density distribution in high energy density (HED) matter. In this work, we designed a high energy electron radiography (HEER) system based on a linear electron accelerator to evaluate its capability for imaging HED matter. 40 MeV electron beams were used to image an aluminum target to study the density resolution and spatial resolution of HEER. The results demonstrate a spatial resolution of tens of micrometers. The interaction of the beams with the target and the beam transport of the transmitted electrons are further simulated with EGS5 and PARMELA codes, with the results showing good agreement with the experimental resolution. Furthermore, the experiment can be improved by adding an aperture at the Fourier plane.

areal density resolution↗

Deep Hierarchical Super Resolution for Scientific Data

We present a novel technique for hierarchical super resolution (SR) with neural networks (NNs), which upscales volumetric data represented with an octree data structure to a high-resolution uniform gridwith minimal seam artifacts on octree node boundaries. Our method uses existing state-of-the-art SR models and adds flexibility to upscale input data with varying levels of detail across the domain, instead of only uniform grid data that are supported in previous approaches.The key is to use a hierarchy of SR NNs, each trained to perform 2x SR between two levels of detail, with a hierarchical SR algorithm that minimizes seam artifacts by starting from the coarsest level of detail and working up.We show that our hierarchical approach outperforms baseline interpolation and hierarchical upscaling methods, and demonstrate the usefulness of our proposed approach across three use cases including data reduction using hierarchical downsampling+SR instead of uniform downsampling+SR, computation savings for hierarchical finite-time Lyapunov exponent field calculation, and super-resolving low-resolution simulation results for a high-resolution approximation visualization.

97 MATHEMATICS AND COMPUTING↗

High-resolution whole-brain DCE-MRI using constrained reconstruction: Prospective clinical evaluation in brain tumor patients

Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm{sup 3}, FOV 22 × 22 × 4.2 cm{sup 3}, and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm{sup 3}, and broader coverage 22 × 22 × 19 cm{sup 3}. Temporal resolution was 5 s for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.

60 APPLIED LIFE SCIENCES↗

The Effect of Gamma-ray Detector Energy Resolution on the Ability to Identify Radioactive Sources

This report describes the results of an initial study on radiation detector spectral resolution, along with the underlying methodology used. The study was done as part of an ongoing effort in Detection Modeling and Operational Analysis (DMOA) for the DNDO System Architecture Directorate. The study objective was to assess the impact of energy resolution on radionuclide identification capability, measured by the ability to reliably discriminate between spectra associated with 'threats' (defined as fissile materials) and radioactive 'non-threats' that might be present in the normal stream of commerce. Although numerous factors must be considered in deciding which detector technology is appropriate for a specific application, spectral resolution is a critical one for homeland security applications in which a broad range of non-threat sources are present and very low false-alarm rates are required. In this study, we have proposed a metric for quantifying discrimination capability, and have shown how this metric depends on resolution. In future work we will consider other important factors, such as efficiency and volume, and the relative frequency of spectra known to be discrimination challenges in practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Annealing as grown large volume CZT single crystals increased spectral resolution

The spectroscopic performance of current large-volume Cadmium 10% Zinc Telluride, Cd{sub 0.9}Zn{sub 0.1}Te, (CZT) detectors is impaired by cumulative effect of tellurium precipitates (secondary phases) presented in CZT single-crystal grown by low-pressure Bridgman techniques(1). This statistical effect may limit the energy resolution of large-volume CZT detectors (typically 2-5% at 662 keV for 12-mm thick devices). The stochastic nature of the interaction prevents the use of any electronic or digital charge correction techniques without a significant reduction in the detector efficiency. This volume constraint hampers the utility of CZT since the detectors are inefficient at detecting photons >1MeV and/or in low fluency situations. During the project, seven runs CZT ingots have been grown, in these ingots the indium dopant concentrations have been changed in the range between 0.5ppm to 6ppm. The I-R mapping imaging method has been employed to study the Te-precipitates. The Teprecipitates in as-grown CZT wafers, and after annealing wafers have been systematically studied by using I-R mapping system (home installed, resolution of 1.5 {micro}m). We employed our I-R standard annealing CZT (Zn=4%) procedure or two-steps annealing into radiation CZT (Zn=10%), we achieved the 'non'-Te precipitates (size < 1 {micro}m) CZT n+-type with resistivity > 10{sup 9-10} {Omega}-cm. We believe that the Te-precipitates are the p-type defects, its reducing number causes the CZT became n+-type, therefore we varied or reduced the indium dapant concentration during the growth and changed the Te-precipitates size and density by using different Cd-temperature and different annealing procedures. We have made the comparisons among Te-precipitates size, density and Indium dopant concentrations, and we found that the CZT with smaller size of Te-precipitates is suitable for radiation uses but non-Te precipitates is impossible to be used in the radiation detectors, because the CZT would became un-dopant or 'intrinsic' with non radiation affection (we have studied before). We used 3 weeks annealing time for 3-5 mm thickness CZT wafres, if the thickness increased to 10-15mm, the annealing time would be increased to many months, which is very unpractical and very difficult to control the CZT property. We have obtained as-grown CZT by using adding the extra Cd before growth, which showed the smaller size of Te-precipitates and excellent radiation performance. These CZT has very high {micro}{tau}(e) >1 x 10{sup -2}cm{sup 2}/V, {rho} > 2 x 10{sup 10} {Omega}-cm, and the thickness could be up to 80-100mm. The energy resolution of the detector (thickness>10mm) at 662 keV is about 1.2% without any correction (2) and according to Aquila, the 0.5-0.8% resolution at 662 keV would be expected by using appropriated electronic correction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Photocell Readouts in the Development of High Resolution Scintillator Systems

Photomultiplier-based scintillator spectrometers are the systems of choice for a multitude of X-ray and gamma radiation measurement applications. Despite widespread use, they have numerous shortcomings. The most serious is the relatively poor energy resolution that makes isotope identification problematic particularly in the case of trace quantities. Energy resolution in scintillator/photomultiplier tube (PMT) spectrometers is governed by a combination of the crystal intrinsic resolution that includes non-linearity effects, photomultiplier statistics, and the variability in the probability of a scintillation photon generating a photoelectron at the photocathode. It is evident that energy resolution in these systems is linked to both the physics of light generation in the scintillator, as well as the characteristics of the PMT. PMTs also present design problems especially in the case of handheld and portable instruments due to their considerable weight and volume. Additionally, PMTs require well-regulated high voltage and are vulnerable to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards sub-10 nm resolution zone plates using the overlaynanofabrication processes

Soft x-ray zone plate microscopy has proven to be a valuable imaging technique for nanoscale studies. It complements nano-analytic techniques such as electron and scanning probe microscopies. One of its key features is high spatial resolution. We developed an overlay nanofabrication process which allows zone plates of sub-20 nm zone widths to be fabricated. Zone plates of 15 nm outer zones were successfully realized using this process, and sub-15 nm resolution was achieved with these zone plates. We extend the overlay process to fabricating zone plates of 12 nm outer zones, which is expected to achieve 10 nm resolution. In addition, we have identified a pathway to realizing sub-10 nm resolution, high efficiency zone plates with tilted zones using the overlay process.

36 MATERIALS SCIENCE↗

X-ray streak camera temporal resolution improvement using a longitudinal time-dependent field

X-ray streak cameras (XSC) have been known to be one of the fastest detectors forultrafast X-ray science. A number of applications in material science, biochemistry, accelerator physics, require sub-picosecond resolution to study new phenomena. Inthis paper, we report on a new method which can potentially improve the temporal resolution of a streak camera down to 100 femtoseconds. This method uses a time-dependent acceleration field to lengthen the photoelectron bunch, significantlyimproving the time resolution as well as reducing the time dispersion caused byinitial energy spread and the effects fromthe space charge forces. A computer simulation of an XSC using this method shows significant improvement in the resolution.

43 PARTICLE ACCELERATORS↗

Spatial resolution limits for synchrotron-based infrared spectromicroscopy

Detailed spatial resolution tests were performed on beamline 1.4.4 at the Advanced Light Source synchrotron facility in Berkeley, CA. The high-brightness synchrotron source is coupled at this beamline to a Thermo-Electron Continumum XL infrared microscope. Two types of resolution tests in both the mid-IR (using a KBr beamsplitter and an MCT-A* detector) and in the near-IR (using a CaF2 beamsplitter and an InGaAS detector) were performed and compared to a simple diffraction-limited spot size model. At the shorter wavelengths in the near-IR the experimental results begin to deviate from only diffraction-limited. The entire data set is fit using a combined diffraction-limit and demagnified electron beam source size model. This description experimentally verifies how the physical electron beam size of the synchrotron source demagnified to the sample stage on the endstation begins to dominate the focussed spot size and therefore spatial resolution at higher energies. We discuss how different facilities, beamlines, and microscopes will affect the achievable spatial resolution.

43 PARTICLE ACCELERATORS↗

CeBr3 as a High-Resolution Gamma-Ray Detector

Lanthanum halide (LaBr3:Ce) scintillators have been well-documented as high-resolution gamma-ray detectors that are operated at room temperature. These scintillators have better resolution (<3% at 662 keV) relative to sodium iodide (NaI(Tl)) scintillators (7% at 662 keV), but the naturally occurring radioactive isotope 138La causes self-activity in the crystal that occludes portions of the gamma-ray spectrum. This selfactivity limits the use of LaBr3:Ce in high-sensitivity applications. Cerium, the dopant in the LaBr3:Ce matrix possesses useful scintillation properties, and its selfactivity is on the order of 3750 times less than La; however, Ce has not been fully characterized as the chief component in a scintillation detector. This work investigated Ce as the key scintillation matrix component in a scintillation detector with the hypothesis that CeBr3 promises energy resolution comparable or superior to LaBr3:Ce. The researchers involved with this work believe that CeBr3 may be the answer to obtaining high-temperature, high-resolution spectra with greater sensitivity than LaBr3:Ce.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗