Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Signal Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Analog Nonvolatile Computer Memory Circuits

In nonvolatile random-access memory (RAM) circuits of a proposed type, digital data would be stored in analog form in ferroelectric field-effect transistors (FFETs). This type of memory circuit would offer advantages over prior volatile and nonvolatile types: In a conventional complementary metal oxide/semiconductor static RAM, six transistors must be used to store one bit, and storage is volatile in that data are lost when power is turned off. In a conventional dynamic RAM, three transistors must be used to store one bit, and the stored bit must be refreshed every few milliseconds. In contrast, in a RAM according to the proposal, data would be retained when power was turned off, each memory cell would contain only two FFETs, and the cell could store multiple bits (the exact number of bits depending on the specific design). Conventional flash memory circuits afford nonvolatile storage, but they operate at reading and writing times of the order of thousands of conventional computer memory reading and writing times and, hence, are suitable for use only as off-line storage devices. In addition, flash memories cease to function after limited numbers of writing cycles. The proposed memory circuits would not be subject to either of these limitations. Prior developmental nonvolatile ferroelectric memories are limited to one bit per cell, whereas, as stated above, the proposed memories would not be so limited. The design of a memory circuit according to the proposal must reflect the fact that FFET storage is only partly nonvolatile, in that the signal stored in an FFET decays gradually over time. (Retention times of some advanced FFETs exceed ten years.) Instead of storing a single bit of data as either a positively or negatively saturated state in a ferroelectric device, each memory cell according to the proposal would store two values. The two FFETs in each cell would be denoted the storage FFET and the control FFET. The storage FFET would store an analog signal value, between the positive and negative FFET saturation values. This signal value would represent a numerical value of interest corresponding to multiple bits: for example, if the memory circuit were designed to distinguish among 16 different analog values, then each cell could store 4 bits. Simultaneously with writing the signal value in the storage FFET, a negative saturation signal value would be stored in the control FFET. The decay of this control-FFET signal from the saturation value would serve as a model of the decay, for use in regenerating the numerical value of interest from its decaying analog signal value. The memory circuit would include addressing, reading, and writing circuitry that would have features in common with the corresponding parts of other memory circuits, but would also have several distinctive features. The writing circuitry would include a digital-to-analog converter (DAC); the reading circuitry would include an analog-to-digital converter (ADC). For writing a numerical value of interest in a given cell, that cell would be addressed, the saturation value would be written in the control FFET in that cell, and the non-saturation analog value representing the numerical value of interest would be generated by use of the DAC and stored in the storage FFET in that cell. For reading the numerical value of interest stored in a given cell, the cell would be addressed, the ADC would convert the decaying control and storage analog signal values to digital values, and an associated fast digital processing circuit would regenerate the numerical value from digital values.

MacLeod, Todd↗

Investigating Np(VI) Nitrate Speciation Control through Temperature and Optical Spectroscopy

Numerous areas of nuclear processing, such as radioisotope production, nuclear waste remediation, and separations, depend upon the speciation of f-elements in the solution state. However, fundamental knowledge of the actinides─particularly Np─lags behind most of the elements on the periodic table. Despite the importance of Np(VI) chemistry in separations and nuclear processing, its speciation in HNO 3 remains uncertain. This work addresses some of these gaps by investigating the effect of HNO 3 concentration and temperature on the spectra and speciation of the Np(VI) nitrate system. Six samples of Np in 1 to 10 M HNO 3 were prepared and treated with (NH 4 ) 2 [Ce(NO 3 ) 6 ] to stabilize the hexavalent oxidation state. The absorbance spectrum of the 10 M HNO 3 is drastically different from the spectra of the other samples; the 10 M spectrum indicates coordination of nitrate ligands to the Np(VI)O 2 2+ ion to form a complex with high symmetry. Additionally, absorbance spectra were recorded over the temperature range of 15 to 40 °C, and systematic increases and decreases in certain spectral features of the ultraviolet–visible (UV–vis)–near-infrared (NIR) spectra are present in the spectra. The difference in spectral features suggests that Np(VI) nitrate speciation depends on temperature. Dilution studies of this sample were monitored with UV–vis–NIR and Raman spectroscopies. Spectral data indicate the presence of multiple complexes with different symmetries, including a high-symmetry complex with an inversion center. As samples are diluted and aquo ligands replace nitrate ligands bound to the Np(VI) neptunyl cation, changes in spectroscopic signals indicate a decrease in the high-symmetry nitrate complex and an increase in the lower-symmetry aquo complex. Additionally, the Raman band associated with the Np(VI)O 2 2+ symmetric stretch broadens with dilution and is fitted with two peaks. These peaks are assigned to Np(VI) aquo and nitrato complexes, indicating that this vibrational mode is sensitive to the coordination environment of the Np(VI) neptunyl cation and that contributions from these two Np(VI) complexes can be distinguished. This unique experimental data could be used to advance computational models describing the electronic transitions of complex actinyl ions.

Absorption↗

Video Guidance Sensor and Time-of-Flight Rangefinder

A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The additional timing and control signals generated by the FPGA would cause the VGS to alternate between an imaging (direction-finding) mode and a time-of-flight (range-finding mode) and would govern operation in the range-finding mode.

Bryan, Thomas↗

Predicting chatter using machine learning and acoustic signals from low-cost microphones

Machining chatter is a phenomenon resulting from self-oscillation between a machining tool and workpiece. This self-oscillation results in variation on the machined product that reduces the ability to meet desired specifications. Chatter is a widely studied topic as it directly relates to the quality of machined products. Here, this study details the application of a Random Forest (RF) classifier with Recursive Feature Elimination (RFE) to machining audio collected by a single microphone during down-milling operations. This approach allows straightforward feature elimination that results in an easily understood set of analyzed dimensions. Stability is predicted solely based on the classification output of the RF classifier. Our approach proves highly predictive with consistent machining setup and a small sample set. We also review transferability between machining setups and present key findings. Our RF approach demonstrates the ability to analyze and classify chatter through a low-cost approach with limited training data required. The motivation for using a single microphone is to enable detection on machines without other sensors, such as accelerometers, present in the machining setup. The value of the in-process sensor and chatter classifier is highlighted because the machining setup included asymmetric dynamics that reduced the accuracy of the traditional analytical stability solution. We see a natural progression to deploying this audio-only methodology with real-time processing and classification using either a laptop or smartphone. This progression will allow visual indicators during the machining process that can alert machinists of progression into unstable machining processes.

42 ENGINEERING↗

Hybrid Oscillator-Qubit Quantum Processors: Instruction Set Architectures, Abstract Machine Models, and Applications

This tutorial offers a pedagogical guide to hybrid quantum processors that integrate discrete-variable (DV) qubits and continuous-variable (CV) oscillators. Aimed at computer scientists, engineers, and physicists, it provides an overview of the experimental, algorithmic, and architectural aspects of this novel and rapidly developing hardware model. Experimental realizations of this model include superconducting, trapped-ion, and neutral-atom platforms. By combining DV and CV components, hybrid oscillator-qubit processors enable a powerful new paradigm that offers complementary strengths for quantum control, error correction, computation, and simulation. Working toward the goal of a full-stack system connecting applications to CV-DV hardware, we define and formulate abstract machine models and instruction set architectures. These essential abstractions enable codesign of hardware and software, and resource estimation for exploring the potential of current and future hardware for computational and simulation tasks. Using these abstractions, we present both new and existing examples that illustrate the benefits of hybrid CV-DV processors relative to traditional DV-only hardware in computation as well as quantum simulation of physical models. Examples include algorithms for transferring states between DV and CV systems, performing the quantum Fourier transform, and simulation of lattice gauge theories. Relative to qubit-only hardware, the bosonic degrees of freedom natively available in hybrid architectures can substantially reduce the circuit complexity of simulations for physical models containing bosons. A key technique is the extension of quantum signal processing ideas to CV-DV systems. This work is intended to serve as a timely and comprehensive guide to this relatively unexplored yet promising approach to quantum computation and to provide a road map to guide future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ground-based Network and Supersite Measurements for Studying Aerosol Properties and Aerosol-Cloud Interactions

From radiometric principles, it is expected that the retrieved properties of extensive aerosols and clouds from reflected/emitted measurements by satellite (and/or aircraft) should be consistent with those retrieved from transmitted/emitted radiance observed at the surface. Although space-borne remote sensing observations contain large spatial domain, they are often plagued by contamination of surface signatures. Thus, ground-based in-situ and remote-sensing measurements, where signals come directly from atmospheric constituents, the sun, and the Earth-atmosphere interactions, provide additional information content for comparisons that confirm quantitatively the usefulness of the integrated surface, aircraft, and satellite datasets. The development and deployment of AERONET (AErosol RObotic NETwork) sunphotometer network and SMART-COMMIT (Surface-sensing Measurements for Atmospheric Radiative Transfer - Chemical, Optical & Microphysical Measurements of In-situ Troposphere) mobile supersite are aimed for the optimal utilization of collocated ground-based observations as constraints to yield higher fidelity satellite retrievals and to determine any sampling bias due to target conditions. To characterize the regional natural and anthropogenic aerosols, AERONET is an internationally federated network of unique sunphotometry that contains more than 250 permanent sites worldwide. Since 1993, there are more than 480 million aerosol optical depth observations and about 15 sites have continuous records longer than 10 years for annual/seasonal trend analyses. To quantify the energetics of the surface-atmosphere system and the atmospheric processes, SMART-COMMIT instrument into three categories: flux radiometer, radiance sensor and in-situ probe. Through participation in many satellite remote-sensing/retrieval and validation projects over eight years, SMART-COMMIT have gradually refine( and been proven vital for field deployment. In this paper, we will demonstrate the capability of AERONET SMART-COMMIT in current Asian Monsoon Year-2008 campaigns that are designed and being executed to study the compelling variability in temporal scale of both anthropogenic and natural aerosols (e.g., airborne dust, smoke, mega-city pollutant). Feedback mechanisms between aerosol radiative effects and monsoon dynamics have been recently proposed, however there is a lack of consensus on whether aerosol forcing would be more likely to enhance or reduce the strength of the monsoon circulation. We envision robust approaches which well-collocated ground-based measurements and space-borne observations will greatly advance our understanding of absorbing aerosols (e.g., "Global Dimming" vs. "Elevated Heat-Pump" effects) on aerosol cloud water cycle interactions.

Tsay, Si-Chee↗

Deep learning-based spatio-temporal fusion for high-fidelity ultra-high-speed X-ray radiography

Full-field ultra-high-speed (UHS) X-ray imaging experiments have been well established to characterize various processes and phenomena. However, the potential of UHS experiments through the joint acquisition of X-ray videos with distinct configurations has not been fully exploited. In this paper, we investigate the use of a deep learning-based spatio-temporal fusion (STF) framework to fuse two complementary sequences of X-ray images and reconstruct the target image sequence with high spatial resolution, high frame rate and high fidelity. We applied a transfer learning strategy to train the model and compared the peak signal-to-noise ratio (PSNR), average absolute difference (AAD) and structural similarity (SSIM) of the proposed framework on two independent X-ray data sets with those obtained from a baseline deep learning model, a Bayesian fusion framework and the bicubic interpolation method. The proposed framework outperformed the other methods with various configurations of the input frame separations and image noise levels. With three subsequent images from the low-resolution (LR) sequence of a four times lower spatial resolution and another two images from the high-resolution (HR) sequence of a 20 times lower frame rate, the proposed approach achieved average PSNRs of 37.57 dB and 35.15 dB, respectively. When coupled with the appropriate combination of high-speed cameras, the proposed approach will enhance the performance and therefore the scientific value of UHS X-ray imaging experiments.

deep learning↗

MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

NASA Discipline Cardiopulmonary↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Lidar Observations of Atmospheric CO2 Column During 2014 Summer Flight Campaigns

Advanced knowledge in atmospheric CO2 is critical in reducing large uncertainties in predictions of the Earth' future climate. Thus, Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) from space was recommended by the U.S. National Research Council to NASA. As part of the preparation for the ASCENDS mission, NASA Langley Research Center (LaRC) and Exelis, Inc. have been collaborating in development and demonstration of the Intensity-Modulated Continuous-Wave (IM-CW) lidar approach for measuring atmospheric CO2 column from space. Airborne laser absorption lidars such as the Multi-Functional Fiber Laser Lidar (MFLL) and ASCENDS CarbonHawk Experiment Simulator (ACES) operating in the 1.57 micron CO2 absorption band have been developed and tested to obtain precise atmospheric CO2 column measurements using integrated path differential absorption technique and to evaluate the potential of the space ASCENDS mission. This presentation reports the results of our lidar atmospheric CO2 column measurements from 2014 summer flight campaign. Analysis shows that for the 27 Aug OCO-2 under flight over northern California forest regions, significant variations of CO2 column approximately 2 ppm) in the lower troposphere have been observed, which may be a challenge for space measurements owing to complicated topographic condition, heterogeneity of surface reflection and difference in vegetation evapotranspiration. Compared to the observed 2011 summer CO2 drawdown (about 8 ppm) over mid-west, 2014 summer drawdown in the same region measured was much weak (approximately 3 ppm). The observed drawdown difference could be the results of the changes in both meteorological states and the phases of growing seasons. Individual lidar CO2 column measurements of 0.1-s integration were within 1-2 ppm of the CO2 estimates obtained from on-board in-situ sensors. For weak surface reflection conditions such as ocean surfaces, the 1- s integrated signal-to-noise ratio (SNR) of lidar measurements at 11 km altitude reached 376, which was equivalent to a 10-s CO2 error 0.33 ppm. For the entire processed 2014 summer flight campaign data, the mean differences between lidar remote sensed and in-situ estimated CO2 values were about -0.013 ppm. These results indicate that current laser absorption lidar approach could meet space measurement requirements for CO2 science goals.

Lin, Bing↗

Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

NASA Discipline Cardiopulmonary↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗

CryoCart Restoration and Vacuum Pipe Construction

Propulsion systems that utilize hypergolic propellants have been used to power space vehicles since the beginning of the space program. Liquid methane and oxygen propulsion systems have emerged as an alternative and have proven to be more environmentally friendly. The incorporation of liquid methane/liquid oxygen (LOX) into the propulsion system has demonstrated an increase in engine performance, as well as a reduction in the volume, size and complexity of the system. Consequently, reducing the total mass of the vehicle which is a crucial aspect that is considered when planning space missions to both the Moon and Mars [1]. Project Morpheus has made significant advancements in liquid oxygen/liquid methane propulsion system technologies by incorporating a LOX/methane propulsion system to a vertical test bed. The vehicle consisted of a 5,000 lb main engine and four 20 lb remote control system (RCS) engines that utilize liquid methane/LOX as its propellant [1]. The vehicle completed successful flight testing at Kennedy Space Center in 2014 which marked the completion of the Morpheus project. Subsequent projects utilizing Morpheus' vertical test bed have been developed to make further advancements. One of the subsequent projects consisted of the addition of a smaller 2,000 lb main engine and a cold helium heat exchanger which would make it possible for a pressurant tank systems to be send to Mars or the Moon by significantly decreasing the overall mass and volume of the pressurant tank. The hot fire tests of the integrated system with the smaller main engine and cold helium heat exchanger were successful at sea level, but further studies are being conducted to better understand how the vertical test bed will behave under thermal-vacuum conditions. For this reason, the integrated vehicle will be taken to Plum Brook to be tested in a chamber capable of simulating these conditions. To ensure that the vehicle will function properly under vacuum conditions, testing will be first completed at the component level. During this process, the igniter of the main engine and the RCS thrusters will be tested under a vacuum. To complete the testing of the components, the test setup first needed to be finalized. The CryoCart is being used to feed the propellants to the test article. The CryoCart is a movable test set-up that was developed in 2009 to provide a mobile platform for testing oxygen/methane systems with hot-fire capability up to 100 lbf. The CryoCart consists of three different systems: Oxygen, Methane, and liquid Nitrogen. The Oxygen and Methane systems are placed into two different carts while the liquid nitrogen system is mainly located in the methane cart. Over the years, the CryoCart has been utilized for different projects and has undergone deterioration. For this reason, a new phase has been developed to rebuild it to working conditions once again. During my internship, I was aiding in the construction and restoration of the CryoCart. In the initial stages of the process, I updated the fluid and electrical schematics for the oxygen, methane, and test article systems. The original CryoCart consisted of an electrical panel that utilized electromechanical relays and a terminal to drive the igniter power and signal, as well as the main fuel and oxygen valves. This electrical panel connected to the CryoCart through various wire harnesses that could be found exiting from the CryoCart. First, it was determined how these harnesses connected to the electromechanical relays so that they worked correctly. Once the electrical system was understood, an alternative for the electromechanical relays and the Molex connectors used throughout the system was sought since these components can often prove to be unreliable. Solid State relays and MIL connectors were purchased to serve as replacements. Upon arrival of the parts, crimping and wiring was completed to install the new solid state relays and MIL connectors. During the replacement of the relays and connectors, system checks of the electrical system were ran to ensure that the system was working correctly. While completing system checks, the pressure transducers that were not functioning properly were also replaced and any issue with the wiring or signal was addressed. Once the electrical components were replaced, the restoration of the fluid system began. Parts of the tubing in the CryoCart had to be rebuild and often consisted of sizing, cutting, bending, filing, and sanding the tubing to prepare it to be flared. Many components had to be proof-tested to bring their certifications up to date, and several components had to be replaced. Various flex hoses, valves, and fittings were send to the Clean Lab because they were new, dirty, or had gone through proof-testing. Once they arrived from the cleaning lab they had to be put back to the system and leak checks and functional tests were conducted. In the Nitrogen system, the copper tubing located in the Oxygen cart was rebuild and Aerogel insulation was added to this section. A new gaseous nitrogen system was added to the CryoCart to purge the vacuum tube which will serve as the test chamber. Once the CryoCart was completed, construction of parts of the vacuum tube began. A flange was manufactured with welded fittings to hold the line of the vacuum pump as well as some extra fittings which will serve as extra inlets used to introduce fluid lines to the vacuum tube. Stress analysis was ran in this flange to ensure that it would not fail under vacuum conditions. The fluid lines leading from the air side of the vacuum to the test article were also constructed and added to the mount that had already been manufactured. Three different sets of tubing were constructed to accommodate the seven different RCS thruster and the main engine igniter that are going to be tested. Full electrical system checks were completed to ensure that all the wire harnesses and valves were functioning. Upon the completion of the CryoCart and the vacuum tube, hot fire testing for the RCS thrusters and the main engine igniter are going to begin. During this time any issues encountered with the engines or igniter will be addressed to ensure that the components function under vacuum conditions. After successful completion of testing, the vertical test bed, Morpheus, will be rebuilt and prepared to be sent to Plum Brook. In Plum Brook, the vehicle will be tested in the thermal-vacuum chamber to demonstrate that integrated lox-methane propulsion system operation in space-like conditions. This internship has allowed me the opportunity to gain valuable hands on experience and to develop skills that will aid in my education as well as in the workforce, while at the same time helping me determine that I would like to further pursue a career in propulsion engineering.

Chaidez, Mariana↗

Prediction Skill of the MJO Teleconnection Signals in the NASA GEOS Subseasonal Reforecasts

Tropical-extratropical teleconnections are considered key to advancing subseasonal prediction. The Madden Julian oscillation (MJO), characterized by large scale convective envelopes propagating along the tropical Indo-Pacific sector, is known to modulate midlatitude circulation and associated weather patterns. Although there is a general consensus on the MJO's influence on the midlatitude circulation, which is thought to be due to modulations of the North Atlantic Oscillation (NAO) and the Pacific North America (PNA) pattern, relatively less is known about the predictability of these teleconnection signals in dynamical forecast models. The composite evolution of the midlatitude circulation anomalies and associated wave train structure as the delayed response to tropical heating are reported in many studies that have examined reanalyses and long model simulations. However, it is yet to be determined whether they lend any beneficial subseasonal forecast skill, especially to weekly mean surface temperature and precipitation over North America. Investigating useful predictable signals from the MJO teleconnections is also complicated by the fact that the MJO is a moving heat source with an approximate periodicity of 30-60 days, and that the structure and amplitude of the midlatitude response can be sensitive to the longitudinal positioning of the heating anomaly as well as the propagation speed of the MJO. The objective of this study is to investigate the impact of MJO teleconnections on forecast accuracy at 2-3 week lead over North America, with an emphasis on the above-mentioned lesser known aspects of these teleconnections. To this end, we utilize a suite of subseasonal reforecasts performed with the latest NASA GEOS-5 seasonal-to-subseasonal (S2S) system. These reforecasts were performed as part of the NOAA SubX project, wherein the NASA GEOS-5 atmosphere-ocean coupled model was run at degree horizontal resolution, initialized every 5 days for the period 1999-2016. The GEOS-5 model shows skillful predictions of the MJO, with the correlation coefficient based on the real-time multivariate MJO (RMM) index staying at or above 0.5 up to forecast lead 26-36 days. The system is thus a useful tool for investigating MJO teleconnection processes.

Achuthavarier, Deepthi↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Editorial special issue: Advancing foundational sun-induced chlorophyll fluorescence science

The first research on the possibilities offered by chlorophyll-a fluorescence to track the daily course of CO 2 assimilation by leaves dates back to the last century (Kautsky and Hirsch, 1931). In the second half of the XXth Century, the development of the field of active fluorescence, which relies mainly on the pulse amplitude modulation (PAM) fluorimetry technique, allowed the unraveling of the relationship between the yield of chlorophyll-a fluorescence and photochemistry (linear electron transport), which is modulated by a third process known as non-photochemical quenching (Genty et al., 1989). Since then, active fluorescence has been regularly used in ecophysiology, forestry, and crop sciences to understand the plant response to stress (Schreiber, 2004). Since the beginning of the 2000s, the development of portable field spectrometers allows for measuring passive sun-induced fluorescence (SIF) at strong solar or telluric absorption features, which do not rely on the use of artificial excitation light (e.g., Meroni and Colombo, 2006; Meroni et al., 2009; Perez-Priego et al., 2005). Since then, the field has rapidly evolved, and now fluorescence is measurable with automated field spectrometers in the field (Grossmann et al., 2018; Gu et al., 2019b; Rossini et al., 2010), airborne platforms (Rascher et al., 2015; Zarco-Tejada et al., 2000), and satellites (Guanter et al., 2012; Sun et al., 2018). These advances offer the potential to couple ecosystem-scale measurements of CO 2 fluxes and SIF to probe new aspects related to ecosystem structural impacts on SIF andphotosynthesis processes at different time-scales and on different ecosystems (e.g., Damm et al., 2010; Magney et al., 2019; Porcar-Castell et al., 2021). While SIF has been proven as a good proxy of gross primary productivity (GPP), mainly across large spatial and temporal gradients, a series of studies showed that different factors could confound this relationship, namely different canopy structures (e.g., Dechant et al., 2020; Migliavacca et al., 2017), stress conditions (e.g., Martini et al., 2022; Wieneke et al., 2018; Wohlfahrt et al., 2018), nutritional conditions (Cendrero-Mateo et al., 2015; Martini et al., 2019), species-specific differences (e.g., Van Wittenberghe et al., 2013) and light regimes (e.g., Liu and Liu, 2018). At the same time, the modeling of SIF developed rapidly (Gu et al., 2019a; Han et al., 2022; Han et al., 2021; van der Tol et al., 2014; van der Tol et al., 2009) and with an increasing degree of realism, offering the possibility to retrieve important vegetation parameters from remote sensing (Pacheco-Labrador et al., 2019; Verrelst et al., 2015; Verrelst et al., 2016; Zhang et al., 2014). Excellent and comprehensive reviews of the field are by (Mohammed et al., 2019; Porcar-Castell et al., 2021; Porcar-Castell et al., 2014; Sun et al., 2023a; Sun et al., 2023b). Despite the exponential increase in the number of publications in the field, significant progress is still needed. Here, this special issue aims to report foundational SIF science, including theoretical modeling and measurement-based research that is urgently needed to unleash the full potential of SIF for physiological and ecological applications at scales spanning from leaf to globe. The 14 articles collected in this special issue reported on the following specific aspects: first, technical capabilities enabling spectrally resolved SIF observations and their inter-comparability in space and time; second, theoretical developments in SIF-photosynthesis relationships to correctly interpret the signal and extract mechanistic information on vegetation structure and function; third, evaluation of the potential of SIF to track process beyond photosynthesis, such as transpiration; fourth, large scale-applications of SIF observations; and finally, upscaling fluorescence from leaf to canopy scales.

54 ENVIRONMENTAL SCIENCES↗