Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Use of the target diagnostic control system in the National Ignition Facility

The extreme physics of targets shocked by NIF's 192-beam laser are observed by a diverse suite of diagnostics including optical backscatter, time-integrated, time resolved and gated X-ray sensors, laser velocity interferometry, and neutron time of flight. Diagnostics to diagnose fusion ignition implosion and neutron emissions have been developed. A Diagnostic Control System (DCS) for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost Window XP processor and Java application. Instruments are aggregated as needed in the supervisory system to form an integrated diagnostic. The Java framework provides data management, control services and operator GUI generation. During the past several years, over thirty-six diagnostics have been deployed using this architecture in support of the National Ignition Campaign (NIC). The DCS architecture facilitates the expected additions and upgrades to diagnostics as more experiments are performed. This paper presents the DCS architecture, framework and our experiences in using it during the NIC to operate, upgrade and maintain a large set of diagnostic instruments.

42 ENGINEERING↗

NASA astrophysics - Optical systems to explore the universe

Major and minor NASA astrophysical research efforts in the near-term are outlined, together with projections of direction for future projects. The Space Telescope is being readied for a 1986 launch and will feature an f/24, 2.4 m aperture, an MgF2 mirror with better than 1/60 wavelength accuracy and will be diffraction-limited in the UV. Pointing accuracy is designed to be 0.007 arcsec for 24 hr. Optical, spectrometric, and photometric equipment will be included. Around 1990, Shuttle-based missions will include an IR telescope and a subarcsec solar surface imaging device. A free-flying X-ray observatory (AXAF) is planned and will include a sensitivity that exceeds that of the HEAO-2 spacecraft by two orders of magnitude. Instruments are under development for higher resolution UV, gamma-ray, and IR studies. In-orbit interferometry is being studied and will depend on in-orbit assembly and servicing of stable structures with segmented optics.

Pellerin, C. J., Jr.↗

Signal-to-noise based local decorrelation compensation for speckle interferometry applications

Speckle-based interferometric techniques allow assessing the whole-field deformation induced on a specimen due to the application of load. These high sensitivity optical techniques yield fringe images generated by subtracting speckle patterns captured while the specimen undergoes deformation. The quality of the fringes, and in turn the accuracy of the deformation measurements, strongly depends on the speckle correlation. Specimen rigid body motion leads to speckle decorrelation that, in general, cannot be effectively counteracted by applying a global translation to the involved speckle patterns. In this paper, we propose a recorrelation procedure based on the application of locally evaluated translations. The proposed procedure implies dividing the field into several regions, applying a local translation, and calculating, in every region, the signal-to-noise ratio (SNR). Since the latter is a correlation indicator (the noise increases with the decorrelation) we argue that the proper translation is that which maximizes the locally evaluated SNR. The search of the proper local translations is, of course, an interactive process that can be facilitated by using a SNR optimization algorithm. The performance of the proposed recorrelation procedure was tested on two examples. First, the SNR optimization algorithm was applied to fringe images obtained by subtracting simulated speckle patterns. Next, it was applied to fringe images obtained by using a shearography optical setup from a specimen subjected to mechanical deformation. Our results show that the proposed SNR optimization method can significantly improve the reliability of measurements performed by using speckle-based techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-frequency optical-depth maps and the case for free-free absorption in two compact symmetric radio sources: The CSO candidate J1324 + 4048 and the CSO J0029 + 3457

We obtained dual-polarization very long baseline interferometry observations at six frequencies of the compact symmetric object J0029 + 3457 and the compact symmetric object candidate J1324 + 4048. By comparing the three lower-frequency maps with extrapolations of the high-frequency maps, we produced maps of the optical depth as a function of frequency. The morphology of the optical-depth maps of J1324 + 4048 is strikingly smooth, suggestive of a foreground screen of absorbing gas. The spectra at the intensity peaks fit a simple free-free absorption (FFA) model, with χ{sub ν}{sup 2}≈2, better than a simple synchrotron self-absorption model, in which χ{sub ν}{sup 2}≈3.5--5.5. We conclude that the case for FFA in J1324 + 4048 is strong. The optical-depth maps of J0029 + 3457 exhibit structure, but the morphology does not correlate with that in the intensity maps. The fit of the spectra at the peaks to a simple FFA model yields χ{sub ν}{sup 2}≈1, but because the turnover is gradual, the fit is relatively insensitive to the input parameters. We find that FFA by a thin amount of gas in J0029 + 3457 is likely but not definitive. One compact feature in J0029 + 3457 has an inverted spectrum even at the highest frequencies. We infer this to be the location of the core and estimate an upper limit to the magnetic field of order 3 Gauss at a radius of order 1 pc. In comparison with maps from observations at earlier epochs, no apparent growth in either J1324 + 4048 or J0029 + 3457 is apparent, with upper limits of 0.03 and 0.02 mas yr{sup –1}, corresponding to maximum linear separation speeds of 0.6c and 0.4c.

79 ASTRONOMY AND ASTROPHYSICS↗

Early science with the Korean VLBI network: evaluation of system performance

We report the very long baseline interferometry (VLBI) observing performance of the Korean VLBI Network (KVN). The KVN is the first millimeter-dedicated VLBI network in East Asia. The KVN consists of three 21 m radio telescopes with baseline lengths in a range of 305-476 km. The quasi-optical system equipped on the antennas allows simultaneous observations at 22, 43, 86, and 129 GHz. The first fringes of the KVN were obtained at 22 GHz on 2010 June 8. Test observations at 22 and 43 GHz on 2010 September 30 and 2011 April 4 confirmed that the full cycle of VLBI observations works according to specification: scheduling, antenna control system, data recording, correlation, post-correlation data processing, astrometry, geodesy, and imaging analysis. We found that decorrelation due to instability in the hardware at times up to 600 s is negligible. The atmosphere fluctuations at KVN baseline are partly coherent, which allows us to extend integration time under good winter weather conditions up to 600 s without significant loss of coherence. The post-fit residuals at KVN baselines do not exhibit systematic patterns, and the weighted rms of the residuals is 14.8 ps. The KVN is ready to image compact radio sources both in snapshot and full-track modes with residual noise in calibrated phases of less than 2 deg at 22 and 43 GHz and with dynamic ranges of ∼300 for snapshot mode and ∼1000 for full-track mode. With simultaneous multi-frequency observations, the KVN can be used to make parsec-scale spectral index maps of compact radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Investigations of laser-induced damages in fused silica optics using x-ray laser interferometric microscopy

A novel x-ray laser (XRL) application, aimed at understanding the microscopic effects involved in formation of laser-induced damage in optical materials exposed to high-power sub-ns laser pulses, is presented. Standard fused silica substrates with permanent damage threshold below 20 J/cm{sup 2}, when irradiated by 438 nm laser pulses, were probed in situ by a neonlike zinc XRL at 21.2 nm. The probing beamline employed a double Lloyd's mirror x-ray interferometer, used in conjunction with an imaging mirror to achieve magnification of {approx}8. In conjunction with an array of in situ optical diagnostics, the main question addressed is whether the damage on the rear surface of the beamsplitter is transient or permanent. The second issue, examined by both the x-ray interferometric microscopy and the optical diagnostics, is whether a local rear-surface modification is associated with nonlinear effects such as self-focusing or filamentation of the damaging laser beam in the bulk.

36 MATERIALS SCIENCE↗

Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited)

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7–14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Read-only optical storage medium

Photosensitive recording medium consists of thin-film silicone resin deposited on photoconductive substrate. Medium is useful for holographic interferometry studies.

Gange, R. A.↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

A Photonic Clockwork for Deployed Timing and Radar

We present an environmentally robust photonic RF/microwave clockwork with low size, weight, and power (SWaP) for next-generation, field-deployable timing and radar applications. Compared to microwave references, optical local oscillators offer superior fractional frequency stability and phase-noise performance. When transferred with high fidelity into the RF/microwave domain, this “optical advantage” promises unparalleled performance across both private-industry and government (e.g., defense and space-agency) applications including very-long-baseline interferometry (VLBI), alternative positioning, navigation, and timing (PNT), multi-static synthetic aperture radar (MSAR), and geodetic sensing. However, this potential has yet to be fully realized outside the metrology lab primarily due to the high-SWaP and excessive environmental susceptibility of both the optical reference itself as well as the optical frequency comb (OFC) required to transfer the optical stability into the RF/microwave domain. Here, we present two demonstrations of a low-SWaP, environmentally robust photonic clockwork used to make a high-fidelity optical-microwave link with the stability and phase-noise performance relevant to the applications described above. Additionally, operational-testing results of the OFC subsystem under application-relevant environmental conditions will be presented to show pathway to field deployment of this critical subsystem.

Guangning Yang↗

Readout of micromechanical cantilever sensor arrays by Fabry-Perot interferometry

The increasing use of micromechanical cantilevers in sensing applications causes a need for reliable readout techniques of micromechanical cantilever sensor (MCS) bending. Current optical beam deflection techniques suffer from drawbacks such as artifacts due to changes in the refraction index upon exchange of media. Here, an adaptation of the Fabry-Perot interferometer is presented that allows simultaneous determination of MCS bending and changes in the refraction index of media. Calibration of the instrument with liquids of known refraction index provides an avenue to direct measurement of bending with nanometer precision. Versatile construction of flow cells in combination with alignment features for substrate chips allows simultaneous measurement of two MCS situated either on the same, or on two different support chips. The performance of the instrument is demonstrate in several sensing applications, including adsorption experiments of alkanethioles on MCS gold surfaces, and measurement of humidity changes in air.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of an Infrared Reference Frame

The mission of the European Space Agency's Hipparcos satellite was to provide high precision astrometric and photometric data for over 100,000 stars and somewhat lower precision data on over a million additional stars. These observations were made in the optical band (340 - 850 nm) and resulted in median precisions of better than 1 milli-arcsec (mas) in position and parallax and I mas/yr in proper motion. The Hipparcos frame is inertial within an estimated uncertainty of +/- 0.25 mas/yr. The other important wavelength band for astrometry has been the radio band. A reference frame has been defined based on absolute Very Long Baseline Interferometry (VLBI) positions of several hundreds of radio sources. There have been a number of projects to refine the link between the optical and radio reference frames. In recent years there has been increasing interest in the astrometry of infrared sources. For example, stars with circumstellar shells can be observed in both the optical and radio (e.g. SiO maser emission). The infrared emission from such sources is dominated by thermal dust emission. The spatial distribution of radiation in the three bands is expected to be quite different. In 1982 we proposed a number of infrared-selected sources (S(sub 10 micron) greater than or approx. equal to 100 J(sub y)) for inclusion in the Hipparcos Input Catalog. Most of those sources were observed, and in Sutton (1997) we report the optical astrometric results (position, proper motion, and parallax) for 87 such sources. These sources were selected to have reasonable agreement between infrared and optical positions, and so may be used as primary standards for future infrared astrometry. They are well distributed across the sky, but exhibit some bias towards the galactic plane and the northern hemisphere. We have also obtained a set of 1480 secondary standards (unpublished) A comparison between optical positions and 86 GHz SiO maser positions for 10 sources indicates coincidence at the 0.15 arcsec level, consistent with current uncertainties in the SiO positions. Improved measurements of the SiO maser positions are needed. VLBI data show that SiO maser spots can be distributed in broken rings of radii 10 - 30 mas, presumably centered on the stellar position. However the SiO flux may be distributed asymmetrically, in which case the flux-weighted center of the SiO emission can be different from the stellar position. We have also published a related paper on phase fluctuations in millimeter interferometry (Sutton and Hueckstaedt 1996). Radiometric monitoring of emission from atmospheric water vapor may be a method for correcting for such fluctuations. This is relevant to positional determinations at centimeter and millimeter wavelengths. The integration of visible, infrared, and radio astrometry is one of our principal goals.

Sutton, Edmund C.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

A new multifunction acousto-optic signal processor

An acousto-optic architecture for simultaneously obtaining time integration correlation and high-speed power spectrum analysis was constructed using commercially available TeO2 modulators and photodiode detector-arrays. The correlator section of the processor uses coherent interferometry to attain maximum bandwidth and dynamic range while achieving a time-bandwidth product of 1 million. Two correllator outputs are achieved in this system configuration. One is optically filtered and magnified 2 : 1 to decrease the spatial frequency to a level where a 25-MHz bandwidth may be sampled by a 62-mm array with elements on 25-micro centers. The other output is magnified by a factor of 10 such that the center 4 microseconds of information is available for estimation of time-difference-of-arrival to within 10 ns. The Bragg cell spectrum-analyzer section, which also has two outputs, resolves a 25-MHz instantaneous bandwidth to 25 kHz and can determine discrete-frequency reception time to within 15 microseconds. A microprocessor combines spectrum analysis information with that obtained from the correlator.

Berg, N. J.↗

Extreme ultraviolet lithography: A few more pieces of the puzzle

The work described in this dissertation has improved three essential components of extreme ultraviolet (EUV) lithography: exposure tools, photoresist, and metrology. Exposure tools. A field-averaging illumination stage is presented that enables nonuniform, high-coherence sources to be used in applications where highly uniform illumination is required. In an EUV implementation, it is shown that the illuminator achieves a 6.5% peak-to-valley intensity variation across the entire design field of view. In addition, a design for a stand-alone EUV printing tool capable of delivering 15 nm half-pitch sinusoidal fringes with available sources, gratings and nano-positioning stages is presented. It is shown that the proposed design delivers a near zero line-edge-rougness (LER) aerial image, something extremely attractive for the application of resist testing. Photoresist. Two new methods of quantifying the deprotection blur of EUV photoresists are described and experimentally demonstrated. The deprotection blur, LER, and sensitivity parameters of several EUV photoresists are quantified simultaneously as base weight percent, photoacid generator (PAG) weight percent, and post-exposure bake (PEB) temperature are varied. Two surprising results are found: (1) changing base weight percent does not significantly affect the deprotection blur of EUV photoresist, and (2) increasing PAG weight percent can simultaneously reduce LER and E-size in EUV photoresist. The latter result motivates the development of an EUV exposure statistics model that includes the effects of photon shot noise, the PAG spatial distribution, and the changing of the PAG distribution during the exposure. In addition, a shot noise + deprotection blur model is used to show that as deprotection blur becomes large relative to the size of the printed feature, LER reduction from improved counting statistics becomes dominated by an increase in LER due to reduced deprotection contrast. Metrology. Finally, this dissertation describes MOSAIC, a new wavefront metrology that enables complete wavefront recovery from print or aerial image based measurements. This new technique, based on measuring the local focal length of the optic at sampled positions in the pupil, recovers the curvature of the aberration and uses the curvature to recover the aberration itself. In a modeled EUV implementation, MOSAIC is shown to recover the SEMATECH Berkeley MET wavefront with a 4.2% RMS error: a 4% improvement over the reported errors of the original lateral shearing interferometry wavefront measurement.

36 MATERIALS SCIENCE↗

Active optics for space astronomy.

Discussion of the segmented and deformable active optics approaches underlying some of the modern electrooptical techniques that are to be used in the design of future generations of giant-aperture orbital space telescopes. Combinations of laser interferometry and precise servomechanisms are shown to make possible the solution of such key problems of large monolithic mirrors in orbit as weight, thermal distortion, launchability, and material stability. The applicability of these active optics approaches to future giant-aperture space astronomy systems in the 200-inch to 400-inch diameter range is reviewed.

Wischnia, H. F.↗