Search NASA⌕ Search

SEARCH · Search NASA

Results for “code comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Development and Application of Preliminary TOGA Model for CO 2 -EOR with Comparison to Resistivity Data

A new TOUGH code, TOGA (Transport of Oil, Gas, Aqueous), is used to model enhanced oil recovery (EOR) from a South Texas field where a combination of water, CO 2 , and WAG (water-alternating-gas) injection wells are located in the down-dip region of a fault block, with oil and natural gas production occurring from wells located up-dip. The reservoir is composed of interlayered sands and shales at a depth of about 2000 m. TOGA considers three fluid phases (oil, gas, and aqueous), and multiple components. Oil field data including compositional analysis of stock-tank oil, gas-oil ratio, and gas gravity are used to determine the composition of oil and gas phases. Initial conditions for aqueous saturation are determined from a depth to surface resistivity survey conducted prior to the onset of CO 2 injection and Archie’s Law. Simulation results after several years of EOR operations are then converted back to resistivity maps and compared to images created by time-lapse depth-to-surface resistivity surveys. These surveys show a strong increase in resistivity, interpreted as the replacement of aqueous phase by injected CO 2 . In contrast, preliminary TOGA results show that injected CO 2 displaced more oil than water, suggesting that the three-phase relative permeability curves used to describe the interference of fluid phases need to be modified. Limited information on the composition of produced fluids provides another data set for comparison with model results. Model variations including using different relative permeability curve parameters and WAG cycle durations yielded improved model matches to the field data. The practical simplifications needed to simulate an actual operating oil field and the limited amount of field operation data available preclude using the present model to get an accurate history match or to make detailed predictions. Rather, the modeling is intended to illustrate the general trends occurring during CO 2 -EOR and to indicate where more detailed information is needed.

02 PETROLEUM↗

Modelling the nonlinear plasma response to externally applied three-dimensional fields with the Stepped Pressure Equilibrium Code

Small-amplitude, symmetry-breaking magnetic field perturbations, including resonant magnetic perturbations (RMPs) and error fields, can profoundly impact plasma properties in both tokamaks and stellarators. In this work, we perform the first comparison between the Stepped Pressure Equilibrium Code (SPEC) (a comparatively fast and efficient equilibrium code based on energy-minimisation principles) and M3D-C 1 (a high-fidelity albeit computationally expensive initial-value extended-magnetohydro-dynamic (MHD) code) to assess the conditions under which SPEC can be used to model the nonlinear, non-ideal plasma response to an externally applied (m = 2,n = 1) RMP field in an experimentally relevant geometry. We find that SPEC is able to capture the plasma response in the weakly nonlinear regime – meaning perturbation amplitudes below the threshold for break up of the separatrix and onset of secondary magnetic island formation – when around half of the total toroidal flux is enclosed in the volume containing the q = 2 resonant surface. Further, the observed dependence of SPEC solutions on input parameters, including toroidal flux and the number of volumes into which the plasma is partitioned, indicates that additional exploration of the underlying Multi-Region Relaxed MHD physics model is needed to constrain the choice of parameters. Nonetheless, this work suggests promising applications of SPEC to optimisation and fusion plasma design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sci—Thur AM: YIS - 03: irtGPUMCD: a new GPU-calculated dosimetry code for {sup 177}Lu-octreotate radionuclide therapy of neuroendocrine tumors

In peptide receptor radionuclide therapy (PRRT), huge inter-patient variability in absorbed radiation doses per administered activity mandates the utilization of individualized dosimetry to evaluate therapeutic efficacy and toxicity. We created a reliable GPU-calculated dosimetry code (irtGPUMCD) and assessed {sup 177}Lu-octreotate renal dosimetry in eight patients (4 cycles of approximately 7.4 GBq). irtGPUMCD was derived from a brachytherapy dosimetry code (bGPUMCD), which was adapted to {sup 177}Lu PRRT dosimetry. Serial quantitative single-photon emission computed tomography (SPECT) images were obtained from three SPECT/CT acquisitions performed at 4, 24 and 72 hours after {sup 177}Lu-octreotate administration, and registered with non-rigid deformation of CT volumes, to obtain {sup 177}Lu-octreotate 4D quantitative biodistribution. Local energy deposition from the β disintegrations was assumed. Using Monte Carlo gamma photon transportation, irtGPUMCD computed dose rate at each time point. Average kidney absorbed dose was obtained from 1-cm{sup 3} VOI dose rate samples on each cortex, subjected to a biexponential curve fit. Integration of the latter time-dose rate curve yielded the renal absorbed dose. The mean renal dose per administered activity was 0.48 ± 0.13 Gy/GBq (range: 0.30–0.71 Gy/GBq). Comparison to another PRRT dosimetry code (VRAK: Voxelized Registration and Kinetics) showed fair accordance with irtGPUMCD (11.4 ± 6.8 %, range: 3.3–26.2%). These results suggest the possibility to use the irtGPUMCD code in order to personalize administered activity in PRRT. This could allow improving clinical outcomes by maximizing per-cycle tumor doses, without exceeding the tolerable renal dose.

60 APPLIED LIFE SCIENCES↗

An Experimental Comparison of Cyclic Variations in Diesel–Natural Gas and POMDME–Natural Gas Dual Fuel Combustion

Abstract Cyclic variations in internal combustion engines are caused by various factors, including combustion mixture stratification, in-cylinder flows, local fluctuations in air-fuel ratio, etc. Cyclic variations have a profound impact on engine performance and emissions. In this study, cyclic variations in dual fuel combustion are analyzed, comparing diesel–natural gas (NG) and polyoxymethylene dimethyl ether (POMDME)-NG dual fuel combustion. Cyclic variability was initially quantified using the coefficient of variation of gross indicated mean effective pressure (IMEPg) computed from experimental cylinder pressure data. The cases analyzed in this study had a coefficient of variation (COV) of IMEPg greater than or around 5%, which was the lower limit of onset of instability for this engine. Experiments were performed at two fixed start of injection (SOI) of high-cetane fuel: 310 CAD and 350 CAD. For all experiments, a constant load of 5 bar IMEPg was maintained, and the intake boost pressure and rail pressure were fixed at 1.5 bar and 500 bar, respectively. For each case, 1000 cycles of cylinder pressure data were recorded, filtered, and processed using an in-house heat release analysis code for each cycle. A comparison between individual cycles and the “ensemble averaged cycle” was made for both diesel–NG and POMDME–NG combustion. For the early SOI of 310 CAD, the peak cylinder pressure fluctuations of individual cycle were found to be ± 15 bar for both fuel combinations, compared to the ensemble averaged cycle, and < 1/10th of the cycles had an IMEPg lower than 0.05 bar of the ensemble averaged cycle. However, the peak pressure fluctuations were found to be lower for POMDME–NG (±3 bar) than diesel–NG dual fuel combustion at 350 CAD SOI, indicating lower cyclic variations. The higher reactivity of POMDME helped reduce fluctuations in combustion phasing at the retarded SOI. The presence of cycles of deterioration and cycles of recovery were also observed with diesel–NG combustion for 310 CAD SOI, and the scatter in the IMEPg return map was similar for both fuel combinations. The IMEPg return map for POMDME–NG combustion was less scattered at the 350 CAD SOI.

Engineering↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilities of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilities are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL_4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow calculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilites of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilites are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow claculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation of the STAT7 Code

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from highly enriched uranium fuel to low- enriched uranium fuel. The key capabilities of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilities are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow calculations are involved. This problem can be corrected in a later version of the code. However, it does not affect the application of STAT7 as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-784: Using MLC Log Files for Daily IMRT Delivery Verification

Purpose: To verify daily intensity modulated radiation therapy (IMRT) treatments using multi-leaf collimator (MLC) log files. Methods: The MLC log files from a NovalisTX Varian linear accelerator were used in this study. The MLC files were recorded daily for all patients undergoing IMRT or volumetric modulated arc therapy (VMAT). The first record of each patient was used as reference and all records for subsequent days were compared against the reference. An in house MATLAB software code was used for the comparisons. Each MLC log file was converted to a fluence map (FM) and a gamma index (γ) analysis was used for the evaluation of each daily delivery for every patient. The tolerance for the gamma index was set to 2% dose difference and 2mm distance to agreement while points with signal of 10% or lower of the maximum value were excluded from the comparisons. Results: The γ between each of the reference FMs and the consecutive daily fraction FMs had an average value of 99.1% (ranged from 98.2 to 100.0%). The FM images were reconstructed at various resolutions in order to study the effect of the resolution on the γ and at the same time reduce the time for processing the images. We found that the comparison of images with the highest resolution (768×1024) yielded on average a lower γ (99.1%) than the ones with low resolution (192×256) (γ 99.5%). Conclusion: We developed an in-house software that allows us to monitor the quality of daily IMRT and VMAT treatment deliveries using information from the MLC log files of the linear accelerator. The information can be analyzed and evaluated as early as after the completion of each daily treatment. Such tool can be valuable to assess the effect of MLC positioning on plan quality, especially in the context of adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Implementation and validation of a wake model for vortex-surface interactions in low speed forward flight

The wake model was implemented using a VAX 750 and a Microvax II workstation. Online graphics capability using a DISSPLA graphics package. The rotor model used by Beddoes was significantly extended to include azimuthal variations due to forward flight and a simplified scheme for locating critical points where vortex elements are placed. A test case was obtained for validation of the predictions of induced velocity. Comparison of the results indicates that the code requires some more features before satisfactory predictions can be made over the whole rotor disk. Specifically, shed vorticity due to the azimuthal variation of blade loading must be incorporated into the model. Interactions between vortices shed from the four blades of the model rotor must be included. The Scully code for calculating the velocity field is being modified in parallel with these efforts to enable comparison with experimental data. To date, some comparisons with flow visualization data obtained at Georgia Tech were performed and show good agreement for the isolated rotor case. Comparison of time-resolved velocity data obtained at Georgia Tech also shows good agreement. Modifications are being implemented to enable generation of time-averaged results for comparison with NASA data.

Komerath, Narayanan M.↗

Cross-Validation of Computational and Experimental Distributed Surface Pressures on the Space Launch System

This paper presents a new workflow for comparing experimental pressure-sensitive paint (PSP) data to computational fluid dynamic (CFD) simulations by way of mapping data from corresponding grids utilizing interpolation methods. In addition to generating quantitative and qualitative point-to-point comparisons between PSP and CFD data, this workflow extracts sectional loading data from both grids and generates lineload comparison charts for corresponding PSP and CFD runs. Experimental PSP data presented in this paper were taken from a 2016 NASA Ames Research Center Unitary Plan Wind Tunnel 11- by 11-Foot Transonic WindTunnel Facility test of the NASA Space Launch System. CFD simulation data for comparison purposes were generated using the FUN3D code. Overall, interpolation onto PSP grids versus CFD grids yields comparable surface pressure fields. However, lineload comparisons are easier to make on the CFD grid-mapped data due to the grid topology and the current capabilities of the lineload analysis tools at NASA Langley Research Center. This workflow is written using contemporary software (Python, Tecplot, PyTecplot), is compatible with existing tools at NASA Langley, and is developed to be adaptable depending on the situation.

SLS↗

Understanding the anomalous dispersion of doubly-ionized carbon plasmas near 47 nm

Over the last several years we have predicted and observed plasmas with an index of refraction greater than one in the soft X-ray regime. These plasmas are usually a few times ionized and have ranged from low-Z carbon plasmas to mid-Z tin plasmas. Our main calculational tool has been the average atom code. We have recently observed C{sup 2+} plasmas with an index of refraction greater than one at a wavelength of 46.9 nm (26.44 eV). In this paper we compare the average atom method, AVATOMKG, against two more detailed methods, OPAL and CAK, for calculating the index of refraction for the carbon plasmas and discuss the different approximations used. We present experimental measurements of carbon plasmas that display this anomalous dispersion phenomenon. It is shown that the average atom calculation is a good approximation when the strongest lines dominate the dispersion. However, when weaker lines make a significant contribution, the more detailed calculations such as OPAL and CAK are essential. During the next decade X-ray free electron lasers and other X-ray sources will be available to probe a wider variety of plasmas at higher densities and shorter wavelengths so understanding the index of refraction in plasmas will be even more essential. With the advent of tunable X-ray lasers the frequency dependent interferometer measurements of the index of refraction may enable us to determine the absorption coefficients and line-shapes and make detailed comparisons against our atomic physics codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methodology comparison for gamma-heating calculations in material-testing reactors

The Jules Horowitz Reactor (JHR) is a Material-Testing Reactor (MTR) under construction in the south of France at CEA Cadarache (French Alternative Energies and Atomic Energy Commission). It will typically host about 20 simultaneous irradiation experiments in the core and in the beryllium reflector. These experiments will help us better understand the complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuels. Gamma heating, i.e. photon energy deposition, is mainly responsible for temperature rise in non-fuelled zones of nuclear reactors, including JHR internal structures and irradiation devices. As temperature is a key parameter for physical models describing the behavior of material, accurate control of temperature, and hence gamma heating, is required in irradiation devices and samples in order to perform an advanced suitable analysis of future experimental results. From a broader point of view, JHR global attractiveness as a MTR depends on its ability to monitor experimental parameters with high accuracy, including gamma heating. Strict control of temperature levels is also necessary in terms of safety. As JHR structures are warmed up by gamma heating, they must be appropriately cooled down to prevent creep deformation or melting. Cooling-power sizing is based on calculated levels of gamma heating in the JHR. Due to these safety concerns, accurate calculation of gamma heating with well-controlled bias and associated uncertainty as low as possible is all the more important. There are two main kinds of calculation bias: bias coming from nuclear data on the one hand and bias coming from physical approximations assumed by computer codes and by general calculation route on the other hand. The former must be determined by comparison between calculation and experimental data; the latter by calculation comparisons between codes and between methodologies. In this presentation, we focus on this latter kind of bias. Nuclear heating is represented by the physical quantity called absorbed dose (energy deposition induced by particle-matter interactions, divided by mass). Its calculation with Monte Carlo codes is possible but computationally expensive as it requires transport simulation of charged particles, along with neutrons and photons. For that reason, the calculation of another physical quantity, called KERMA, is often preferred, as KERMA calculation with Monte Carlo codes only requires transport of neutral particles. However, KERMA is only an estimator of the absorbed dose and many conditions must be fulfilled for KERMA to be equal to absorbed dose, including so-called condition of electronic equilibrium. Also, Monte Carlo computations of absorbed dose still present some physical approximations, even though there is only a limited number of them. Some of these approximations are linked to the way how Monte Carlo codes apprehend the transport simulation of charged particles and the productive and destructive interactions between photons, electrons and positrons. There exists a huge variety of electromagnetic shower models which tackle this topic. Differences in the implementation of these models can lead to discrepancies in calculated values of absorbed dose between different Monte Carlo codes. The magnitude of order of such potential discrepancies should be quantified for JHR gamma-heating calculations. We consequently present a two-pronged plan. In a first phase, we intend to perform compared absorbed dose / KERMA Monte Carlo calculations in the JHR. This way, we will study the presence or absence of electronic equilibrium in the different JHR structures and experimental devices and we will give recommendations for the choice of KERMA or absorbed dose when calculating gamma heating in the JHR. In a second phase, we intend to perform compared TRIPOLI4 / MCNP absorbed dose calculations in a simplified JHR-representative geometry. For this comparison, we will use the same nuclear data library for both codes (the European library JEFF3.1.1 and photon library EPDL97) so as to isolate the effects from electromagnetic shower models on absorbed dose calculation. This way, we hope to get insightful feedback on these models and their implementation in Monte Carlo codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Code Benchmark of Depressurized Conduction Cooldown Transient in the High Temperature Test Facility

This paper presents results from modeling of a depressurized conduction cooldown (DCC) transient at the High Temperature Test Facility (HTTF) as part of the OECD-NEA Thermal Hydraulics Code Validation Benchmark for High-Temperature Gas-Cooled Reactors using HTTF Data . This paper briefly describes the benchmark and the models being used. It then presents a comparison of steady state and transient results based on the Problem 2 Exercise 1A and 1B definitions. We compare block and helium temperature distributions, mass flow distribution, and energy balance in steady state. All models show comparable mass flow distributions and energy balances. The temperatures within the core and outer regions are comparable in all models too, but inner reflector temperatures can vary significantly. Despite that, we find that the models are in good agreement for the full-power steady state. In the DCC, we look at block temperature at the core midplane and RCCS water exit temperature. The INL and ANL models are found to be in excellent agreement with one another on block temperature over time, while the agreement when the KAERI and NRG models are added into consideration is good. Differences in the transient heat removal from the RCCS cause the differences in block temperature over time in these models. The CNL models show similar trends to the INL, ANL, KAERI, and NRG models, but the temperatures are high because the volumes used in calculating the average temperature include the heater rods in the CNL models only. The HUN-REN model shows results that suggest significantly lower heat removal in the RCCS which merit further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Off-design computer code for calculating the aerodynamic performance of axial-flow fans and compressors

An off-design axial-flow compressor code is presented and is available from COSMIC for predicting the aerodynamic performance maps of fans and compressors. Steady axisymmetric flow is assumed and the aerodynamic solution reduces to solving the two-dimensional flow field in the meridional plane. A streamline curvature method is used for calculating this flow-field outside the blade rows. This code allows for bleed flows and the first five stators can be reset for each rotational speed, capabilities which are necessary for large multistage compressors. The accuracy of the off-design performance predictions depend upon the validity of the flow loss and deviation correlation models. These empirical correlations for the flow loss and deviation are used to model the real flow effects and the off-design code will compute through small reverse flow regions. The input to this off-design code is fully described and a user's example case for a two-stage fan is included with complete input and output data sets. Also, a comparison of the off-design code predictions with experimental data is included which generally shows good agreement.

Schmidt, James F.↗

Comparison of a NuScale SMR conceptual core design using CASMO5/simulate5 and MCNP5

A key issue during the initial start-ups of new Small Modular Reactors (SMRs) is the lack of operational data for reactor model validation. To help better understand the accuracy of the reactor analysis codes CASMO5 and SIMULATE5, higher order comparisons to MCNP5 have been performed. These comparisons are for an initial core conceptual design of the NuScale reactor. The data have been evaluated at Hot Zero Power (HZP) conditions. Comparisons of core reactivity, fuel temperature coefficient (FTC), and moderator temperature coefficients (MTC) have been performed. Comparison results show good agreement between CASMO5/SIMULATE5 and MCNP5 for the conceptual initial core design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High speed simulation of flexible multibody dynamics

A multiflexible body dynamics code intended for fast turnaround control design trades is described. Nonlinear rigid body dynamics and linearized flexible dynamics combine to provide efficient solution of the equations of motion. Comparison with results from the DISCOS code provide verification of accuracy.

Jacot, A. D.↗

Implementation of Depletion Architecture in the MAMMOTH Reactor Physics Application

Nuclear fuel experiments conducted at the Transient Reactor Test Facility (TREAT) will be analyzed with the MAMMOTH reactor physics application, currently under development at Idaho National Laboratory. MAMMOTH natively couples with the BISON, RELAP-7, and Rattlesnake applications within the MOOSE framework. The methods currently implemented allow for simulating the irradiation of fuel from the beginning of life in a nuclear reactor until it is placed in TREAT for fuel testing using the same finite element mesh throughout the analysis thereby retaining a very high level of resolution and fidelity. The calculation of the isotopic distribution in fuel requires the solution to the decay and transmutation equations coupled to the neutron transport equation. This work focuses on two significant improvements to the MAMMOTH micro-depletion capability. First, the depletion architecture within MAMMOTH is modified to improve the flexibility and speed of burnup calculations. The results of various benchmark tests demonstrate the accuracy of the modified implementation. The second improvement involves the expansion of the data functionality. MAMMOTH can now read the decay data files used by the Oak Ridge Isotope Generation (ORIGEN) code, thus enabling access to data of more than 1,600 isotopes. Comparison of ORIGEN and MAMMOTH for a selected benchmark problem was performed. Both codes yield very similar results, with differences of 0.03% that can be attributed to differences in precision between the two codes. Future work will focus on comparisons between MAMMOTH and ORIGEN for more complex problems.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗