SEARCH · Search NASA
Results for “electrode processing”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development of electrodes for the NASA iron/chromium
This program was directed primarily to the development of the negative (Cr3+/Cr2+) electrode for the NASA chromous/ferric Redox battery. The investigation of the effects of substrate processing and gold/lead catalyzation parameters on electrochemical performance were continued. In addition, the effects of reactant cross-mixing, acidity level, and temperature were examined for both Redox couples. Finally, the performance of optimized electrodes was tested in system hardware (1/3 square foot single cell). The major findings are discussed: (1) The recommended processing temperature for the carbon felt, as a substrate for the negative electrode, is 1650 to 1750 C, (2) The recommended gold catalyzation procedure is essentially the published NASA procedure (NASA TM-82724, Nov. 1981) based on deposition from aqueous methanol solution, with the imposition of a few controls such as temperature (25 C) and precatalyzation pH of the felt (7), (3) Experimental observations of the gold catalyzation process and subsequent electron microscopy indicate that the gold is deposited from the colloidal state, induced by contact of the solution with the carbon felt, (4) Electrodeposited lead appears to be present as a thin uniform layer over the entire surface of the carbon fibers, rather than an discrete particles, and (5) Cross-mixing of reactants (Fe-2+ in negative electrode solution or Cr-3+ in the positive electrode solution) did not appear to produce significant interference at either electrode.
Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint
Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.
Multi-channel front-end ASIC for a 3D position-sensitive detector
Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.
Device and Container for Reheating and Sterilization
Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.
Adaptive Process Controls and Ultrasonics for High Temperature PEM MEA Manufacture
The purpose of this 5-year DOE-sponsored project was to address major process bottlenecks associated with fuel cell manufacturing. New technologies were developed to significantly reduce pressing cycle time for high temperature PEM membrane electrode assembly (MEA) through the use of novel, robust ultrasonic (U/S) bonding processes along with low temperature (<100°C) PEM MEAs. In addition, greater manufacturing uniformity and performance was achieved through (a) an investigation into the causes of excessive variation in ultrasonically and thermally bonded MEAs using more diagnostics applied during the entire fabrication and cell build process, and (b) development of rapid, yet simple quality control measurement techniques for use by industry.
Cathode Electrolyte Diagnostics Based on Scanning Probe Microscopy
Various processes lead to degradation of cathodes in lithium-ion batteries. Questions remain regarding mechanisms of many of these processes. Probe microscopy methods including scanning electrochemical microscopy (SECM) are capable of directly probing processes at the cathode/electrolyte interface. SECM uses a small electrode to perform rapid electrochemical analysis of transient species generated at an active cathode/electrolyte interface. This paper discusses the background of the SECM instrument and its application to lithium-ion battery research. We also describe the application of SECM methods to the study of cathode degradation processes observed in lithium-ion batteries. Specifically, we focus on characterizing the dissolution of manganese from LiMn2O4 (LMO) based on recent debate in the literature. We describe experiments to observe and characterize the electrochemical properties of manganese complexes emerging from degrading LMO electrode materials.
Carbon Nanostructures in Biological Sensors for Space and Terrestrial Applications
Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.
Carbon Nanomaterials for Biosensing Applications
Biosensing devices comprised of carbon nanotubes and nanofibers have been developed for astronaut crew point-of-care. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using carbon nanotube and carbon nanofiber electrodes for biomedical applications. First, a 3x3 electrode device, with each electrode containing 40,000 carbon nanofiber nanoelectrodes was fabricated on silicon using traditional microfabrication processing. The device was demonstrated as a multiplexed immunosensor for simultaneous, label-free detection of cardiac troponin-I, C-reactive protein and myoglobin. Antibodies specific to cardiac troponin-I, C-reactive protein and myoglobin were covalently bound to the CNF surface and were characterized using electrochemical impedance spectroscopy and differential pulse voltammetry. Each step of the modification process resulted in changes in resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific cardiac protein. The real-time label free detection of the three cardiac markers from pure components and mixtures was demonstrated with high sensitivity, down to 0.2 ng/mL, and good selectivity. Detection in human blood serum did not present false positives from non-specific protein adsorption. More recently, this detection scheme has been applied to inkjet printed carbon nanotube electrodes on Kapton and paper. Printed devices have several unique advantages including simple and inexpensive fabrication. The results demonstrate that these sensors can serve a miniaturized, low cost device for detection of proteins in complex mixtures making this platform a good candidate for early stage diagnosis of myocardial infarction. Future inkjet printed devices can be fabricated have the added advantage in their suitability to be manufactured in an in-space, microgravity environment.
Carbon electrode for desalination purpose in capacitive deionization
Carbon electrodes for desalination purpose have been successfully synthesized using activated carbon powder (BET surface area=700 – 1400 m{sup 2}/g), carbon black and polyvinyl alcohol (PVA) binder by cross-linking method with glutaric acid (GA) at 120 °C. The electrochemical properties of the carbon electrodes were analyzed using electrical impedance spectroscopy (EIS) and cyclic voltammetry (CV) whilst the physical properties were observed with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDX). In order to assess the desalting performance, salt removal experiments were performed by constructing a capacitive deionization unit cell with five pairs of carbon electrodes. For each pair consisted of two parallel carbon electrodes separated by a spacer. Desalination and regeneration processes were also observed in the salt-removal experiments. The salt-removal experiments were carried out in single-pass mode using a solution with 0.1 M NaCl at a flow rate of 10 mL/min. A voltage of 3 V was applied to the cell for 60 minutes for both processes in desalination and regeneration. The result showed that the percentage value of the salt-removal was achieved at 20%.
Surface Nanostructuring of Steel in Electrospark Alloying with WC-Based Electrodes
The change in cathode mass and anode erosion during electrospark alloying is investigated, with different process kinetics. With increase in pulse length, the efficiency of deep electrospark alloying increases up to some limit determined by the electrode composition.
MRT 7365: Power flow physics and key physics phenomena
The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.
Electric Field Effects on Fiber Alignment Using an Auxiliary Electrode during Electrospinning
This viewgraph presentation reviews auxiliary and electric field effects on fiber alignment during the process of electrospinning. The contents include: 1) Electrospinning Overview; 2) Experimental Set-up; 3) Jet Exit; 4) Auxiliary Electrode Effects; 5) Electrospinning High Speed Video; 6) Effect of Auxiliary Electrode Position; 7) Micro & Nano Fibers Produced; 8) Micro and Nano Fibrous Mats; 9) Field Effect on Fiber Distribution; 10) Modeling; 11) Calculated trajectories: 5, 10, 15 & 20cm electrode spacing; 12) Off Axis Auxiliary Electrode; 13) Field Strength Effects; and 14) Potential Applications.
The Effect of Strong Acid Functional Groups on Electrode Rise Potential in Capacitive Mixing by Double Layer Expansion
Explore the source record for details and available documents.
Oxide derived Cu nanofibril assembly for enhanced nonenzymatic glucose sensing
In this report, we have prepared copper nanofibril assembly via thermal oxidation followed by electrochemical reduction processes, exhibiting superior glucose detection ability. The morphological analysis evidenced the formation of rough islands or nanofibril structure on the Cu surface depending on initial thermal oxidation temperature. The glucose detection performance was investigated by performing cyclic voltammetry and chronoamperometry with varying glucose concentration. A high sensitivity (4131.57 μA mM – 1 cm – 2 ), low detection limit (1.41 μM), wider linear range (0–3.9 mM) and long–term stability (30 days) have been recorded for electrode thermally oxidized at 400 °C followed by electrochemical reduction process (rCu_400). The sensitivity is almost three times higher in comparison to the planner Cu surface. This significantly enhanced glucose sensing ability rCu_400 has been attributed to the nanofibril morphology, origination of Cu (111) facet and formation of a stable oxide layer evidenced by scanning electron microscopy, X-ray diffraction and energy dispersive spectroscopy analysis. Despite higher sensitivity, rCu_400 electrode does not show any response to the chloride ion, dopamine, ascorbic acid and uric acid. Finally, these results indicate that the Cu nanofibril structure prepared via simple oxidation/reduction process can be an excellent candidate to be used as an electrode for glucose sensing application.
Toward Active-Matrix Lab-On-A-Chip: Programmable Electrofluidic control Enaled by Arrayed Oxide Thin Film Transistors
Agile micro- and nano-fluidic control is critical to numerous life science and chemical science synthesis as well as kinetic and thermodynamic studies. To this end, we have demonstrated the use of thin film transistor arrays as an active matrix addressing method to control an electrofluidic array. Because the active matrix method minimizes the number of control lines necessary (m + n lines for the m x n element array), the active matrix addressing method integrated with an electrofluidic platform can be a significant breakthrough for complex electrofluidic arrays (increased size or resolution) with enhanced function, agility and programmability. An amorphous indium gallium zinc oxide (a-IGZO) semiconductor active layer is used because of its high mobility of 1-15 cm{sup 2} V{sup -1} s{sup -1}, low-temperature processing and transparency for potential spectroscopy and imaging. Several electrofluidic functionalities are demonstrated using a simple 2 x 5 electrode array connected to a 2 x 5 IGZO thin film transistor array with the semiconductor channel width of 50 {mu}m and mobility of 6.3 cm{sup 2} V{sup -1} s{sup -1}. Additionally, using the TFT device characteristics, active matrix addressing schemes are discussed as the geometry of the electrode array can be tailored to act as a storage capacitor element. Finally, requisite material and device parameters are discussed in context with a VGA scale active matrix addressed electrofluidic platform.
A generalized multi-dimensional mathematical model for charging and discharging processes in a supercapacitor
A generalized three dimensional computational model based on unied formulation of electrode- electrolyte-electrode system of a electric double layer supercapacitor has been developed. The model accounts for charge transport across the solid-liquid system. This formulation based on volume averaging process is a widely used concept for the multiphase ow equations ([28] [36]) and is analogous to porous media theory typically employed for electrochemical systems [22] [39] [12]. This formulation is extended to the electrochemical equations for a supercapacitor in a consistent fashion, which allows for a single-domain approach with no need for explicit interfacial boundary conditions as previously employed ([38]). In this model it is easy to introduce the spatio-temporal variations, anisotropies of physical properties and it is also conducive for introducing any upscaled parameters from lower length{scale simulations and experiments. Due to the irregular geometric congurations including porous electrode, the charge transport and subsequent performance characteristics of the super-capacitor can be easily captured in higher dimensions. A generalized model of this nature also provides insight into the applicability of 1D models ([38]) and where multidimensional eects need to be considered. In addition, simple sensitivity analysis on key input parameters is performed in order to ascertain the dependence of the charge and discharge processes on these parameters. Finally, we demonstarted how this new formulation can be applied to non-planar supercapacitors
Hierarchical Electrode Architectures for Electrical Energy Storage & Conversion
The integration and stability of electrocatalytic nanostructures, which represent one level of porosity in a hierarchical structural scheme when combined with a three-dimensional support scaffold, has been studied using a combination of synthetic processes, characterization techniques, and computational methods. Dendritic platinum nanostructures have been covalently linked to common electrode surfaces using a newly developed chemical route; a chemical route equally applicable to a range of metals, oxides, and semiconductive materials. Characterization of the resulting bound nanostructure system confirms successful binding, while electrochemistry and microscopy demonstrate the viability of these electroactive particles. Scanning tunneling microscopy has been used to image and validate the short-term stability of several electrode-bound platinum dendritic sheet structures toward Oswald ripening. Kinetic Monte Carlo methods have been applied to develop an understanding of the stability of the basic nano-scale porous platinum sheets as they transform from an initial dendrite to hole containing sheets. Alternate synthetic strategies were pursued to grow dendritic platinum structures directly onto subunits (graphitic particles) of the electrode scaffold. A two-step photocatalytic seeding process proved successful at generating desirable nano-scale porous structures. Growth in-place is an alternate strategy to the covalent linking of the electrocatalytic nanostructures.