Fast and Scalable Synthesis of LiNi 0.5 Mn 1.5 O 4 Cathode by Sol–Gel-Assisted Microwave Sintering

High-voltage spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) is a promising cathode material for high-energy-density and high-power-density lithium-ion batteries (LIBs). The high cost of the currently available LIBs needs to be addressed urgently for wide application in the transport sector (electric vehicles, buses) and large-scale energy storage systems (ESS). Of significance, herein, novel fast and scalable microwave-assisted synthesis of LNMO is reported, which leads to a production cost cut. X-ray diffraction (XRD) analysis confirms the formation of the desired phase with high crystallinity. Field emission scanning (FE-SEM) and transmission electron microscopy (TEM) analyses indicate that the synthesized phase is of nanometric size (50–150 nm) due to an extremely short sintering time (20 min). The material synthesized at 750 °C shows a higher initial discharge capacity (130 mA h g -1 ) than that synthesized at 650 °C (115 mA h g -1 ). The materials heat treated at higher temperatures show better electrochemical performance in terms of initial capacity, rate capability, and improved cycling. The improved electrochemical performance of LNMO at 750 °C is attributed to the formation of a stable crystal structure, low charge transfer resistance at the electrode/electrolyte interface, high electrical conductivity due to the presence of a disorder structure, and improved ionic diffusivity.

25 ENERGY STORAGE↗

Controlling Covalency and Anion Redox Potentials through Anion Substitution in Li-Rich Chalcogenides

Development of next-generation battery technologies is imperative in the pursuit of a clean energy future. Toward that end, battery chemistries capable of multielectron redox processes are at the forefront of studies on Li-based systems to increase the gravimetric capacity of the cathode. Multielectron processes rely either on the iterative redox of transition metal cations or redox involving both the transition metal cations and the anionic framework. Targeting coupled cation and anion redox to achieve multielectron charge storage is difficult, however, because the structure–property relationships that govern reversibility are poorly understood. In an effort to develop fundamental understanding of anion redox, we have developed a materials family that displays tunable anion redox over a range of potentials that are dependent on a systematic modification of the stoichiometry. We report anion redox in the chalcogenide solid solution Li 2 FeS 2–y Se y , wherein the mixing of the sulfide and selenide anions yields a controllable shift in the high voltage oxidation plateau. Electrochemical measurements indicate that reversible multielectron redox occurs across the solid solution. X-ray absorption spectroscopy supports the oxidation of both iron and selenium at high states of charge, while Raman spectroscopy indicates the formation of Se–Se dimers in Li 2 FeSe 2 upon Li deintercalation, providing insight into the charge mechanism of the Li-rich iron chalcogenides. Anion substitution presents direct control over the functional properties of multielectron redox materials for next generation battery technologies.

25 ENERGY STORAGE↗

Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using wellestablished Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Zhang, Zhengqiao (ORCID:0009000742521735)↗

Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm

Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection coordination concerns, particularly where they are utilized in an unbalanced manner or where loading among phases is unbalanced. Digital relays such as the SEL-751 (produced by Schweitzer Engineering Laboratories, Pullman, WA, USA) series have the capability of being set on a per-phase basis. This capability is underutilized in common practice. Additionally, in optimization algorithms for determining relay settings, the time-overcurrent characteristics (TOCs) of relays are generally not treated as variables and are assigned before running the optimization algorithm. In this paper, TOC options themselves are treated as discrete variables to be considered in the optimization algorithm. A mixed integer nonlinear programming problem (MINLP) is set up where the goal is to minimize relay operating times. A genetic algorithm (GA) approach is implemented in MATLAB where two cases are considered. In the first case, the TOC and Time dial setting (TDS) of each relay is set on a three-phase basis. In the second case, per-phase settings are considered. Relay TDSs and TOCs are both considered as simultaneous discrete control variables. Despite the stochastic nature of using per-phase settings for unbalanced systems is found to generally allow for shorter operating times. However, for relatively balanced systems, it is best to use three-phase settings if computation time is of importance.

Matthews, Ronald C.↗

Interface-engineered (CrMnTiZnCo) 3 O 4 @polypyrrole nano-hybrids for superior lithium storage

High-entropy oxides (HEO) have emerged as promising anode materials for lithium-ion batteries (LIBs) due to their high theoretical specific capacity. However, their practical application is hindered by several challenges, including significant volume expansion, electrode pulverization, and substantial irreversible capacity loss during initial cycles. To address these limitations, this study designed a novel core-shell composite material, denoted as HEO@PPy, which consists of a (CrMnTiZnCo) 3 O 4 -based HEO core and a polypyrrole (PPy) shell. This composite demonstrates remarkable electrochemical performance: it maintains a specific capacity of 1090.1 mAh/g after 100 cycles at 100 mA/g and retains 521.8 mAh/g after 1000 cycles at 1 A/g, highlighting its superior cycling stability. Furthermore, it exhibits excellent rate capability, delivering a capacity of 372.1 mAh/g even at a high current density of 5 A/g. These findings confirm that the strategic compositional and structural design of HEOs, combined with hybridization with conductive polymers like PPy, provides a viable pathway for developing advanced anode materials for next-generation, high-performance lithium-ion batteries.

25 ENERGY STORAGE↗

Self-supported MoO 2 /MoS 2 nano-sheets embedded in a carbon cloth as a binder-free substrate for high-energy lithium–sulfur batteries

As one of the most prospective candidates for next-generation rechargeable batteries, lithium-sulfur (Li-S) batteries currently still encounter great challenges associated with the low conductivity, severe shuttle effects, and sluggish redox kinetics. Herein, a self-supported sulfur host is fabricated by an in-situ growth of MoO 2 /MoS 2 nano-sheets on a carbon cloth (CC). First, carbon cloth serves as a good template for the morphology-controlled synthesis of nanostructured materials, which not only alleviates the agglomeration of MoO2/MoS2, but also enhances the flexibility and mechanical strengthen of the hybrid architecture as a free-standing host. Second, the polysulfide-trapping ability can be greatly enhanced by both physical and chemical adsorption from the MoO 2 /MoS 2 -anchored carbon cloth. Moreover, the partially sulfurized MoO 2 /MoS 2 nano-sheets integrate the benefits of conductive MoO 2 and sulfiphilic MoS 2 , thus facilitating fast charge transfer and redox kinetics of polysulfide conversion. As a result, these attributes enable the host to hold a high sulfur loading (up to 7.6 mg cm -2 ), which exceeds most of the reported carbon cloth-related cathode work in the literature. Furthermore, the Li-S cells can achieve a high peak capacity of 1350 mA h g -1 , excellent rate capability (C/20 - 2C rate), impressive areal capacity (up to 6.3 mA h cm -2 ), and a high capacity retention of 85% after 100 cycles.

25 ENERGY STORAGE↗

Transactive Energy Rationing in Islanded Electric Power Systems

Extreme weather events, many of which are climate change related, are occurring with increasing frequency and intensity and causing catastrophic outages. One of the major modern-day concerns of utilities is dealing with such extreme outages and consequently, its repercussions on the lives of people in society and social aspects. Traditionally, operators have been using rolling blackouts as a contingency plan to serve critical loads during such events when electricity supply is scarce. However, such blackouts practices are executed on a last-minute mandatory basis, depriving customers having low-capacity high priority loads (i.e. refrigeration, water, telecommunication, etc) that should also be serviced if at all possible. Historically, policymakers have often adopted quota-based regulatory actions or rationing for other commodities (such as gasoline, butter, sugar) to handle scarcity situations. Motivated from such quota based systems, our contribution presented in this work is an alternative transactive rationing mechanism that would provide some minimum level of service to all of the customers and serve the critical loads using market-based control during such scarcity-based contingencies. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on two real-life use cases having feeder-level and microgrid-level configurations respectively. The simulation results clearly demonstrate the capability of the rationing scheme to serve customers’ high-priority loads through prolonged outages even during extreme scarcity scenarios.

42 ENGINEERING↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Hydro-battery Hybrids – A Case for Holistic Assessment of Hybrid Energy Systems

With increasing penetration of renewable energy resources like solar and wind, the flexibility offered by the hydropower generation facilities would be instrumental in providing grid reliability. However, hydropower’s capabilities are often constrained to meet asset management targets and environmental flow requirements. To meet these necessary requisites while simultaneously being able to utilize hydropower’s full potential, hydro plus battery hybrids offer a logical solution. However it is often challenging to make the case for economic feasibility of hydro-battery hybrids at the required scale of battery storage. To that end, this paper proposes a multi-objective optimization framework to maximize advantages of hydro-battery hybrid systems from three different avenues: new market opportunities, environmental benefits and machine wear and fatigue. Using an illustrative case study of a peaking plant, we simulate hydropower operations for with and without 120 MWh of battery storage for four different simulated flow patterns ranging from peaking operations to run-of-the-river operations and two intermediate flow patterns in between. The results demonstrate that hybridizing the hydropower plant can potentially generate additional revenue while simultaneously enable more environmental friendly operations and reduce the overall machine wear and tear.

Chalishazar, Vishvas H.↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

Overview of System Integration Analysis Activities for Integrated Waste Management

Spent nuclear fuel (SNF) generated by the current fleet of commercial nuclear reactors is being stored at reactor sites in spent fuel pools (SFPs) and in dry independent spent fuel storage installations (ISFSIs). The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Waste Management (IWM) program is examining a suite of IWM system options and conducting supporting analyses to enable future informed choices. The IWM program is currently organized into the following four major areas: (1) IWM facilities and equipment concepts and development, (2) transportation capability analysis and support, (3) information technology solutions and support, and (4) system integration analysis and support. This paper focuses on the activities ongoing in the IWM system integration analysis and support area. Two main research activities in this area are: data and tools development, validation, and maintenance; and special studies, analyses, and assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Damaged Fuel in the United States - 20325

Throughout the history of commercial nuclear power plant operations in the U.S., many fuel assemblies have lost the capability to perform all of their desired functions. Since they can no longer be handled, stored, or transported in accordance with established regulations, they are classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in damaged fuel cans to be used in conjunction with storage and/or transportation systems. These systems have a limited number of slots that can be filled with damaged fuel cans. A damaged fuel can is generally a stainless-steel container that confines damaged spent nuclear fuel (SNF) and is closed at one end by mesh endpoints that allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of extreme caution, a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S. because relevant regulations do not specify exactly how to classify damaged fuel. Instead, these regulations license/certify packages that specify approved contents. Damaged fuel must be included among the approved contents to be considered acceptable. In many cases, damaged SNF is encapsulated in damaged fuel cans to ensure it can confine gross fuel particles, debris, and/or damaged assemblies to known volumes within loaded casks. A damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was published by the U.S. Energy Information Administration (EIA), which used data from U.S. reactors compiled from 1968 to June 30, 2013, to produce Form GC-859, 'Nuclear Fuel Data Survey.' According to this form, there were 136,821 boiling water reactor (BWR) SNF assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies, for a combined total of 241,468. Of these, 4,521 were classified as failed. Some were also disassembled and the fuel rods or pieces of fuel rods combined to make consolidated assemblies. These consolidated assemblies may include damaged fuel or were perhaps consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing 0 - 264 entire fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in each damaged fuel can. In addition to the consolidated assemblies, 2,391 un-canistered fuel rod pieces exist, which were removed from 494 assemblies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Experimental Aging and Lifetime Prediction in Grid Applications for Large-Format Commercial Li-Ion Batteries

Due to the growth of electric vehicle and stationary energy storage markets, the production and use of lithium-ion batteries has grown exponentially in recent years. For many of these applications, large-format lithium-ion batteries are being utilized, as large cells have less inactive material relative to their energy capacity and require fewer electrical connections to assemble into packs. And especially for stationary energy storage systems, where energy delivered is the only revenue source, the economics of these battery systems is highly dependent on cell lifetime. However, testing of large-format lithium-ion batteries is time consuming and requires high current channels and large testing chambers, making information on the performance of commercial, large-format lithium-ion batteries hard to come by. Here, accelerated aging test data from four commercial large-format lithium-ion batteries is reported. These batteries span both NMC-Gr and LFP-Gr cell chemistries, pouch and prismatic formats, and a range of cell designs with varying power capabilities. Accelerated aging test results are analyzed to examine both cell performance, in terms of efficiency and thermal response under load, as well as cell lifetime. Cell thermal response is characterized by measuring temperature during cycle aging, which is used to calculated a normalized thermal resistance value that may help estimate both cell cooling needs or to help extrapolate aging test results to different thermal environments. Cell lifetime is evaluated qualitatively, considering simply the average calendar and cycle life across a range of conditions, as well as quantitatively, using statistical modeling and machine-learning methods to identify predictive aging models from the accelerated aging data. These predictive aging models are then used to investigate cell sensitivities to stressors, such as cycling temperature, voltage window, and C-rate, as well as to predict cell lifetime in various stationary storage applications. Results from this work show that cell lifetime and sensitivity to aging conditions varies substantially across commercial cells, necessitating testing for specific cell formats to make quantitative lifetime predictions. That being said, all commercial cells tested here are predicted to reach at least 10-year lifetimes for stationary storage applications. Based on the aging test results and modeling, some cells are expected to be relatively insensitive to temperature and use-case, making them suited for simple use cases with little or no thermal management and simple controls, while the lifetime of other cells could be extended to 20+ years if operated with thermal management and degradation-aware controls.

battery↗

A Fast‐Charging and High‐Temperature All‐Organic Rechargeable Potassium Battery

Abstract Developing fast‐charging, high‐temperature, and sustainable batteries is critical for the large‐scale deployment of energy storage devices in electric vehicles, grid‐scale electrical energy storage, and high temperature regions. Here, a transition metal‐free all‐organic rechargeable potassium battery (RPB) based on abundant and sustainable organic electrode materials (OEMs) and potassium resources for fast‐charging and high‐temperature applications is demonstrated. N‐doped graphene and a 2.8 m potassium hexafluorophosphate (KPF 6 ) in diethylene glycol dimethyl ether (DEGDME) electrolyte are employed to mitigate the dissolution of OEMs, enhance the electrode conductivity, accommodate large volume change, and form stable solid electrolyte interphase in the all‐organic RPB. At room temperature, the RPB delivers a high specific capacity of 188.1 mAh g −1 at 50 mA g −1 and superior cycle life of 6000 and 50000 cycles at 1 and 5 A g −1 , respectively, demonstrating an ultra‐stable and fast‐charging all‐organic battery. The impressive performance at room temperature is extended to high temperatures, where the high‐mass‐loading (6.5 mg cm −2 ) all‐organic RPB exhibits high‐rate capability up to 2 A g −1 and a long lifetime of 500 cycles at 70–100 °C, demonstrating a superb fast‐charging and high‐temperature battery. The cell configuration demonstrated in this work shows great promise for practical applications of sustainable batteries at extreme conditions.

25 ENERGY STORAGE↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

CU-BENs: A structural modeling finite element library

The present work discusses capabilities within the finite element library CU-BENs. CU-BENs focuses on applying the finite element method to structural mechanics problems encountered within the context of inverse problems and partitioned fluid–structure interaction; thus element formulations are primarily of a structural type — truss, frame, and triangular discrete Kirchhoff theory shells. CU-BENs defaults to the skyline sparse storage scheme for the system matrix, but also supports other storage schemes when using external libraries such as LAPACK and UMFPACK. CU-BENs includes built-in nonlinear solution strategies, such as the Newton Raphson method and modified spherical arc length method, that are available within static analyses as well within the context of transient dynamic analyses involving a generalized-α implementation of the Newmark implicit time integration scheme.