Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Broadband Fourier-Transform-Detected EPR at W-Band

This manuscript reports development of wideband Fourier transform (FT) electron paramagnetic resonance (EPR) detection capability at the uniquely high frequency of 94 GHz. Here, this technique is based on the HiPER spectrometer developed at the University of St. Andrews, into which we have integrated an arbitrary waveform generator (AWG) that is used to modulate the output from a solid-state multiplier chain prior to amplification, generating up to 1 kW microwave power with 1 GHz bandwidth. Benchmark experiments are presented for a standard TEMPOL radical, which comprises a 500 MHz broad EPR spectrum at 94 GHz. Using a single frequency-swept microwave pulse, efficient inversion of this spectrum is demonstrated, enabling frequency-dependent studies of the magnetization relaxation in the time-domain, again via broadband echo detection. From these measurements, an anisotropy in the spin–lattice relaxation time, T 1 , can be determined with ease for TEMPOL. In addition, we implement the FT detection scheme for multi-dimensional (electron–electron double resonance, or ELDOR) experiments, demonstrating the full capabilities of the HiPER spectrometer. As an example, we present FT-detected version of the ELDOR-detected nuclear magnetic resonance technique for the TEMPOL radical. We also describe potential applications of the new instrumentation for studies of gadolinium qubits.

36 MATERIALS SCIENCE↗

Isolation Standard Measures: A Set of Validated and Feasible Measurements Ensuring Comparability Across Isolation and Confinement Studies

Isolation and confinement studies have been essential to the preparation of crewed long-duration space missions, acting as analogues that facilitate the study of psychological and physiological responses to isolation and confinement. They also serve as opportunities for the development, testing, and validation of countermeasures and coping methods to handle the challenges that arise in such scenarios. Due to the small sample sizes in combination with high inter-individual variability, single isolation campaigns are not always sufficient for obtaining statistically significant scientific findings. To address this issue and improve comparability between different studies, the need for standardized measures to be collected in all future isolation and confinement studies was identified. Additionally, these measures should also be shown to be generally valid, reliable, feasible and acceptable in analogue and spaceflight environments. Standard measures in isolation and confinement studies allow for more direct comparisons of results and synthesis of data across isolation and confinement studies as well as provide an important step toward standard measures in spaceflight. An international expert group with representatives from different space agencies worldwide was brought together to define a core set of standard measures for isolation and confinement studies. This paper provides an overview of the expert group’s recommendations for international standard measures for future isolation and confinement studies, along with subsequent updates coordinated by the International Countermeasures Working Group (ICMWG), which was established as a sub-Working Group under the International Space Life Sciences Working Group (ISLSWG). Additional experts were consulted by the ICMWG partner agencies as required. The collection of the described set of isolation standard measures will provide data on the following parameters: sleep, mood, psychological state, psychophysiology, cognitive performance, stress and the immune system, general health and well-being, team measures, nutritional measures, and environmental conditions. For each measure, recommendations were made about duration and frequency of administration, along with specific implementation recommendations in relation to the duration of the isolation study. The set of isolation standard measures will be reassessed every two years at a minimum to ensure they are up to date and reflect the current state-of-the-art.

Isolation↗

A Spectral Atlas of the Nu(sub 12) Fundamental of (13)C(12)CH6 in the 12 Micron Region

The recent discovery of the minor isotopomer of ethane, (13)C(12)CH6, in the planetary atmospheres of Jupiter and Neptune, added ethane to the molecules which can be used to determine isotopic (12)C(12)C ratios for the jovian planets. The increased spectral resolution and coverage of the IR and far-IR instruments to be carried on the Cassini mission to Saturn and Titan may enable the detection of the minor isotopomer. Accurate frequency and cross-section measurements of the nu(sub 12) fundamental under controlled laboratory condition are important to interpret current and future planetary spectra. High resolution spectra of the minor isotopomer (13)C(12)CH6 have been recorded in the 12.2 micron region using the Kitt Peak Fourier Transform (FTS) and the Goddard Tunable Diode Laser spectrometer (TDL). In a global fit to 19 molecular constants in a symmetric top Hamiltonian, transition frequencies of the nu(sub 12) fundamental ranging up to J=35 and K=20 have been determined with a standard deviation of less than 0.0005 cm(exp -1). From selected line intensity measurements, a vibrational dipole moment for the nu(sub 12) fundamental has been derived. Observed and calculated spectra covering the region from 740 cm(exp -1) and to 910 cm(exp -1) are presented. A compilation of transition frequencies, line intensities, and lower state energies are included for general use in the astronomical community.

Weber, Mark↗

Finite difference time domain modeling of steady state scattering from jet engines with moving turbine blades

The approach chosen to model steady state scattering from jet engines with moving turbine blades is based upon the Finite Difference Time Domain (FDTD) method. The FDTD method is a numerical electromagnetic program based upon the direct solution in the time domain of Maxwell's time dependent curl equations throughout a volume. One of the strengths of this method is the ability to model objects with complicated shape and/or material composition. General time domain functions may be used as source excitations. For example, a plane wave excitation may be specified as a pulse containing many frequencies and at any incidence angle to the scatterer. A best fit to the scatterer is accomplished using cubical cells in the standard cartesian implementation of the FDTD method. The material composition of the scatterer is determined by specifying its electrical properties at each cell on the scatterer. Thus, the FDTD method is a suitable choice for problems with complex geometries evaluated at multiple frequencies. It is assumed that the reader is familiar with the FDTD method.

Ryan, Deirdre A.↗

Radar backscattering from snow facies of the Greenland ice sheet: Results from the AIRSAR 1991 campaign

In June 1991, the NASA/JPL airborne SAR (AIRSAR) acquired C- (lambda = 5.6cm), L- (lambda = 24cm), and P- (lambda = 68m) band polarimetric SAR data over the Greenland ice sheet. These data are processed using version 3.55 of the AIRSAR processor which provides radiometrically and polarimetrically calibrated images. The internal calibration of the AIRSAR data is cross-checked using the radar response from corner reflectors deployed prior to flight in one of the scenes. In addition, a quantitative assessment of the noise power level at various frequencies and polarizations is made in all the scenes. Synoptic SAR data corresponding to a swath width of about 12 by 50 km in length (compared to the standard 12 x 12 km size of high-resolution scenes) are also processed and calibrated to study transitions in radar backscatter as a function of snow facies at selected frequencies and polarizations. The snow facies on the Greenland ice sheet are traditionally categorized based on differences in melting regime during the summer months. The interior of Greenland corresponds to the dry snow zone where terrain elevation is the highest and no snow melt occurs. The lowest elevation boundary of the dry snow zone is known traditionally as the dry snow line. Beneath it is the percolation zone where melting occurs in the summer and water percolates through the snow freezing at depth to form massive ice lenses and ice pipes. At the downslope margin of this zone is the wet snow line. Below it, the wet snow zone corresponds to the lowest elevations where snow remains at the end of the summer. Ablation produces enough meltwater to create areas of snow saturated with water, together with ponds and lakes. The lowest altitude zone of ablation sees enough summer melt to remove all traces of seasonal snow accumulation, such that the surface comprises bare glacier ice.

Rignot, Eric↗

Traveling-Wave Tube Amplifier Model to Predict High-Order Modulation Intersymbol Interference

Demands for increased data rates in satellite communications necessitate higher order modulation schemes, larger system bandwidth, and minimum distortion of the modulated signal as it is passed through the traveling wave tube amplifier (TWTA). One type of distortion that the TWTA contributes to is intersymbol interference (ISI), and this becomes particularly disruptive with wide-band, complex modulation schemes. It is suspected that in addition to the dispersion of the TWT, frequency dependent reflections due to mismatches within the TWT are a significant contributor to ISI. To experimentally investigate the effect of these mismatches within the physical TWT on ISI would be prohibitively expensive, as it would require manufacturing numerous amplifiers in addition to the acquisition of the required digital hardware. In an attempt to develop a more accurate model to correlate IS1 with the TWTA and the operational signal, a fully three-dimensional (3D), time-dependent, TWT interaction model has been developed using the electromagnetic particle-in-cell (PIC) code MAFIA (solution of Maxwell's equations by the Finite-Integration-Algorithm). The model includes a user defined slow-wave circuit with a spatially tapered region of loss to implement a sever, and spatially varied geometry (such as helical pitch) to implement a phase velocity taper. The model also includes user defined input/output coupling and an electron beam contained by solenoidal, electrostatic, or periodic permanent magnet (PPM) focusing allowing standard or novel TWTs to be investigated. This model comprehensively takes into account the effects of frequency dependent nonlinear distortions (MAM and AMPM); gain ripple due to frequency dependent reflections at the input/output coupling, severs, and mismatches from dynamic pitch variations; drive induced oscillations; harmonic generation; intermodulation products; and backward waves.

Kory, Carol L.↗

Research and development for a ground-based hydrogen-maser system

The results of a joint experiment aimed primarily at the determination of the frequency of the H(1) hyperfine transition are reported. The transition frequency value for Cs-133 hyperfine transition is found. The result is the mean of two independent evaluations against the cesium reference, which differ by 0.002 Hz. The one-sigma uncertainty of the value nu sub H is also estimated to be 0.002 Hz. One evaluation is based on wall shift experiments at Harvard University; the other is a result of new wall shift measurement using many storage bulbs of different sizes at the National Bureau of Standards. The experimental procedures and the applied corrections are described. Results for the wall shift and for the frequency of hydrogen are compared with previously published values, and error limits of the experiments are discussed.

Source record↗

Electronic Model of a Ferroelectric Field Effect Transistor

A pair of electronic models has been developed of a Ferroelectric Field Effect transistor. These models can be used in standard electrical circuit simulation programs to simulate the main characteristics of the FFET. The models use the Schmitt trigger circuit as a basis for their design. One model uses bipolar junction transistors and one uses MOSFET's. Each model has the main characteristics of the FFET, which are the current hysterisis with different gate voltages and decay of the drain current when the gate voltage is off. The drain current from each model has similar values to an actual FFET that was measured experimentally. T'he input and o Output resistance in the models are also similar to that of the FFET. The models are valid for all frequencies below RF levels. No attempt was made to model the high frequency characteristics of the FFET. Each model can be used to design circuits using FFET's with standard electrical simulation packages. These circuits can be used in designing non-volatile memory circuits and logic circuits and is compatible with all SPICE based circuit analysis programs. The models consist of only standard electrical components, such as BJT's, MOSFET's, diodes, resistors, and capacitors. Each model is compared to the experimental data measured from an actual FFET.

MacLeod, Todd C.↗

Evaluations of Risks from the Lunar and Mars Radiation Environments

Protecting astronauts from the space radiation environments requires accurate projections of radiation in future space missions. Characterization of the ionizing radiation environment is challenging because the interplanetary plasma and radiation fields are modulated by solar disturbances and the radiation doses received by astronauts in interplanetary space are likewise influenced. The galactic cosmic radiation (GCR) flux for the next solar cycle was estimated as a function of interplanetary deceleration potential, which has been derived from GCR flux and Climax neutron monitor rate measurements over the last 4 decades. For the chaotic nature of solar particle event (SPE) occurrence, the mean frequency of SPE at any given proton fluence threshold during a defined mission duration was obtained from a Poisson process model using proton fluence measurements of SPEs during the past 5 solar cycles (19-23). Analytic energy spectra of 34 historically large SPEs were constructed over broad energy ranges extending to GeV. Using an integrated space radiation model (which includes the transport codes HZETRN [1] and BRYNTRN [2], and the quantum nuclear interaction model QMSFRG[3]), the propagation and interaction properties of the energetic nucleons through various media were predicted. Risk assessment from GCR and SPE was evaluated at the specific organs inside a typical spacecraft using CAM [4] model. The representative risk level at each event size and their standard deviation were obtained from the analysis of 34 SPEs. Risks from different event sizes and their frequency of occurrences in a specified mission period were evaluated for the concern of acute health effects especially during extra-vehicular activities (EVA). The results will be useful for the development of an integrated strategy of optimizing radiation protection on the lunar and Mars missions. Keywords: Space Radiation Environments; Galactic Cosmic Radiation; Solar Particle Event; Radiation Risk; Risk Analysis; Radiation Protection.

Kim, Myung-Hee↗

Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation

Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.

VISUAL ACUITY↗

Evaluation of simulation motion fidelity criteria in the vertical and directional axes

An evaluation of existing motion fidelity criteria was conducted on the NASA Ames Vertical Motion Simulator. Experienced test pilots flew single-axis repositioning tasks in both the vertical and the directional axes. Using a first-order approximation of a hovering helicopter, tasks were flown with variations only in the filters that attenuate the commands to the simulator motion system. These filters had second-order high-pass characteristics, and the variations were made in the filter gain and natural frequency. The variations spanned motion response characteristics from nearly full math-model motion to fixed-base. Between configurations, pilots recalibrated their motion response perception by flying the task with full motion. Pilots subjectively rated the motion fidelity of subsequent configurations relative to this full motion case, which was considered the standard for comparison. The results suggested that the existing vertical-axis criterion was accurate for combinations of gain and natural frequency changes. However, if only the gain or the natural frequency was changed, the rated motion fidelity was better than the criterion predicted. In the vertical axis, the objective and subjective results indicated that a larger gain reduction was tolerated than the existing criterion allowed. The limited data collected in the yaw axis revealed that pilots had difficulty in distinguishing among the variations in the pure yaw motion cues.

Schroeder, Jeffery A.↗

The Use of Additional GPS Frequencies to Independently Determine Tropospheric Water Vapor Profiles

It is well known that the currently employed L1 and L2 GPS/MET frequencies (1.2 - 1.6) Ghz) do not allow for the separation of water vapor and density (or temperature) from active microwave occultation measurements in regions of the troposphere warmer than 240 K Therefore, additional information must be used, from other types of measurements and weather analyses, to recover water vapor (and temperature) profiles. Thus in data sparse regions, these inferred profiles can be subject to larger errors than would result in data rich regions. The use of properly selected additional GPS frequencies enables a direct, independent measurement of the absorption associated with the water vapor profile, which may then be used in the standard GPS/MET retrievals to obtain a more accurate determination of atmospheric temperature throughout the water vapor layer. This study looks at the use of microwave crosslinks in the region of the 22 Ghz water vapor absorption line for this purpose. An added advantage of using 22 Ghz frequencies is that they are only negligibly affected by the ionosphere in contrast to the large effect at the GPS frequencies. The retrieval algorithm uses both amplitude and phase measurements to obtain profiles of atmospheric pressure, temperature and water water vapor pressure with a vertical resolution of 1 km or better. This technique also provides the cloud liquid water content along the ray path, which is in itself an important element in climate monitoring. Advantages of this method include the ability to make measurements in the presence of clouds and the use of techniques and technology proven through the GPS/MET experiment and several of NASA's planetary exploration missions. Simulations demonstrating this method will be presented for both clear and cloudy sky conditions.

Herman, B.M.↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advances in Secure 5G Network for a Nationwide Drone Corridor

Recent research has validated the proposal to add a separate set of antennas for 5G coverage in the air, while the conventional set of antennas continues to provide coverage on the ground, for a nationwide drone corridor for 5G cellular drones. More importantly, this drone corridor can be made secure and reliable by adapting the drone trajectories to avoid interference and security attacks, and with advanced precoding and physical layer security. Energy efficiency can also be improved with low-resolution massive multiple-input multiple-output (MIMO) systems that utilize low resolution digital to analog converters. This paper describes additional research findings to further support the creation of this nationwide drone corridor. We design optimal drone trajectory within the drone corridor to improve safety for pedestrians and vehicles on the ground. We derive the optimum antenna uptilt angle to minimize outage probability for a given drone corridor. We also study the placement of intelligent reflector surfaces in an urban drone corridor in order to improve the multi-path scattering and hence the spatial multiplexing gains for serving drones. We calculate trajectories to maximize data rate in the presence of smart interference when drones are used as relays and each drone may be deployed in the paths of data flows from multiple BSs to multiple UEs. Next we demonstrate how the use of the additional set of antennas along with the 3GPP standard based subframe blanking method can minimize the interference from ground reflection of the radio frequency (RF) radiation from the downtilted antennas. The paper concludes with plans to continue with experimental studies to advance this work further.

99 GENERAL AND MISCELLANEOUS↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Detection of structural deterioration and associated airline maintenance problems

Airline operations involving the detection of structural deterioration and associated maintenance problems are discussed. The standard approach to the maintenance and inspection of aircraft components and systems is described. The frequency of inspections and the application of preventive maintenance practices are examined. The types of failure which airline transport aircraft encounter and the steps taken to prevent catastrophic failure are reported.

Henniker, H. D.↗

On evaluating compliance with air pollution levels 'not to be exceeded more than once a year'

Under a sampling program operated in conformity with EPA guidelines, calculational procedures are described for estimating the corresponding ambient pollution level. The statistical independence of the data, the commutativity of expectation and exponential operations, and the statistical variability of the calculated results are quantitatively evaluated. It is shown that the recommended sampling frequencies of every third to every sixth day are inadequate in determining conformity when the standards are expressed as levels not to be exceeded more than once a year.

Neustadter, H. E.↗

Solar Power Satellite (SPS) pilot beam and communication link subsystem investigation study, phase 1

A preliminary engineering model of ionospheric interactions with the pilot beam was established and used to demonstrate that the dual frequency baseline pilot beam system might not be viable in the presence of an unstable transmission path. Alternate approaches to remove this difficulty are described. Although ionospheric fluctuations will not significantly degrade beam pointing or raise the sidelobe levels, they will reduce transmission efficiency by upwards of 25%. Mitigating strategies to substantially reduce this effect are proposed. Based on the Klystron noise spectrum, the pilot beam transmitter power was determined as a function of frequency offset from the power beam carrier frequency. The RFI from the pilot beam, on the ground and at geosynchronous orbit is shown. Noise levels on the earth's surface due to the SPS are presented as a function of frequency and the number of SPS systems. Analysis of the communication subsystem indicates that a standard telemetry line of 1.544 MB/s would satisfy both voice and data link requirements. Additional links would be required for TV and radio transmissions.

Source record↗